Greenwood EL100, 150HT DC, EL150HT Installation Instructions Manual

Installation Instructions
EL100 & 150HT DC Axial Fans for Kitchens, Bathroom and Toilets
Greenwood Air Management Ltd
Brookside Industrial Estate
Rustington, West Sussex BN16 3LH
Tel: 01903 771021. Fax: 01903 782398
Internet: http//www.marley.co.uk/green.html
Environmental
Slotvent
32
NOTES:
Where an open-flued oil or gas- fuelled appliance is installed in the kitchen, extract ventilation can cause the spillage of flue gases. Care must be taken to ensure ventilation is reduced as appropriate, as set out in the building regulations. The guide to the regulations suggests that the reduced provision should be an extract rate of 20 l/s (72 m
3
/h). Kitchens with solid-fuel appliances
should not have extract fans fitted.
The fans should not be sited where it would be subject to a direct source of heat in excess of 40ºC.
A clearance of 75 mm to be allowed on both sides of fan for the removal of the internal grille.
Operation
The Airvac Elite range of fans are multi speed 24V DC units offering varying extract levels up to and exceeding Building Regulation requirements for kitchens, bathrooms and toilets.
Available as HT operating version only.
TYPE ‘HT’
Control Inputs
Pull Cord – when operated units runs at high speed. A second operation switches fan to automatic control.
Switched Live – when operated units runs at high speed. When removed unit returns to automatic control.
Humidity Level – unit detects humidity level and fan runs when humidity level is above preset level.
On board Controls
Unit is fitted with an overrun timer facility, this is factory preset to time for optimum energy efficiency. The time can be increased to allow unit to run for a period after humidity level has dropped below preset level.
Overrun Timer
Only operates on automatic/humidity control.
To clean or service fan
Remove grille: Lever off at side using coin or screwdriver.
Undo screws (exposed by removal of grille), and pull the fan away from its back plate.
The fan may now be cleaned using a brush or damp cloth. DO NOT IMMERSE IN WATER.
WARNING: On no account should the interior of the fan be cleaned until the unit has been removed from its back plate or isolated from the mains.
See Sensor / Timer Adjustments section for further details.
The Airvac Elite range of fans are fitted with electrical operated anti-backdraught
shutters which have a time delay to open or close.
Read all instructions before commencing installations
54
7
1
3
5
8
4
6
Window Mounting
EL100 Ø = 118 mm ± 1 mm EL150 Ø = 167 mm ± 1 mm
Make sure rubber cable grommet is fitted onto cable before threading cable through fan back plate.
Ø
EL100/150
EW100/150
For window mounting do not install fans in opening windows. Use the correct thickness of glass for the size of window (at least 4 mm thick) if in doubt, contact a glazier.
The components supplied are suitable for the installation of fans in windows from 4 mm single glaze to 28 mm thick double­glazing.
To aid assembly, smear the spigot of the fan or lip of seal with silicone lubricant or silicone polish.
2
SEE PAGE 10 FOR WIRING INSTRUCTIONS
25 mm long screws – Single glazing 38 mm long screws – 20 mm & 24 mm double glazing 50 mm long screws – 28 mm double glazing