Thank you for purchasing the product. AVR-protected socket will automatically maintain a
constant voltage level to protect sensitive electronics from brownouts and overvoltages. With
its fashionable cabinet, it can be installed on a desk or wall without causing an unsightly or
unprofessional image, and will perfectly utilize a limited working environment.
Features:
Provides AVR-protected sockets Provides stable output voltage through boost and buck stabilizer Accepts wide input voltage range Provides over-voltage protection (option) Provides Over-temperature protection (option)
2. Product Overview
Power switch Power LED: green lighting AC input AVR LED: yellow lighting AVR-protected output receptacles  Modem/phone surge protection 5V USB port (option)
3. Installation and Initial Startup
Inspection
Remove the unit from the shipping package and inspect it for damage that may
occurred during transportation. Notify the carrier and place of purchase if any
damage is found.
Placement & Storage Conditions
Install the unit in a protected area that is free of excessive dust and has adequate air flow.
Please place the unit away from other units at least 2.5cm to avoid interference. Do NOT block
the top or side air vents on the unit. Do not operation the unit in an environment where the
ambient temperature or humidity is outside the limits listed in the specifications. Operate the
unit in an environment free of excessive dust, mechanical vibration, inflammable gases and
explosive or corrosive atmospheres.
Connect to the Wall Outlet
Plug the input power cord of the unit to the wall outlet.
Connect the Loads
The AVR-protected receptacles will provide stable power to connected devices by boosting
and bucking the input power. Therefore, simply connect sensitive loads to AVR-protected
receptacles.
Connect Modem/Phone for Surge Protection
Connect a single modem/phone line into surge-protected “IN” outlet on the unit. Connect
from “OUT” outlet to the computer with phone line cable.
Turn On/Off the Unit
Turn on the unit by pressing the power switch to “RESET position. Then, all connected devices will be powered on.
DEFENDO Automatic Voltage Regulator
Quick Guide v.1.0
4. Mounting Unit
The unit can be mounted to a wall surface. There are two ways to position the unit: vertically
and horizontally.
1. Use a ruler to draw a straight line in 114 mm vertically or horizontally on the wall.
2. Use a sharp nail to puncture the center of the two ends to mark the wall.
(see below chart 1 as placing the unit horizontally)
3. Mount the unit by positioning the key-hole slots over the mounting nails. (see chart 2 and
chart 3)
Chart 1 Chart 2 Chart 3
114 mm distance between 2 holes Mounting horizontally Mounting vertically
5. Applications
CAUTION: The total power consumption of all equipment plugged into the voltage
regulator must not exceed its capacity*. A total load in excess of its capacity* will cause the
fuse to fault (blow).
*For the capacity of unit, please check the specifications.
The voltage regulator is designed for use with voltage sensitive equipment such as: a home
computer, monitor, inkjet printer, scanner or fax. It is also designed for use with home
electronics equipment such as television, stereos, CD players, VCRs, and DVD players, data
processing equipment, modems, typewriters, calculators, and telephone equipment.
Appliances not suitable for use with the product are items such as freezers, power tools, air
conditioners, dehumidifiers, blenders, or any device that employs an AC motor for operation.
Not for use with small fuel generators. Also excluded are life sustaining equipment.
When use the voltage regulator with an Uninterruptible Power Supply (UPS), connect the
UPS to the output of this product, then connect the product to the wall outlet.
6. Important Safety Warning (SAVE THESE INSTRUCTIONS)
To safely operate this voltage regulator, please read and follow all instructions
carefully. Read this manual thoroughly before attempting to unpack, install, or
operate. You may keep this quick guide for further reference.
CAUTION: The unit is designed only for use under the 50 Hz input frequency and pure sine
wave environment. Any other input frequency or wave form will effect the voltage range
and load capability.
CAUTION: Please DO NOT connect the unit to the environment with direct voltage or
simulated sine wave.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and
humidity controlled indoor area free of conductive contaminants. (See the specifications for
the acceptable temperature and humidity range.)
7 Specifications
Model
600
1000
1500
CAPACITY
600VA/300W
1000VA/500W
1500VA/750W
INPUT
Voltage
230 VAC
Voltage Range
184-284 VAC
Frequency
50 Hz
OUTPUT
Voltage Regulation
± 10%
Output Receptacles
Schuko x 3 / Universal x 3 / India x 3
INDICATOR
Power LED
Green lighting
AVR LED
Yellow lighting
Over-voltage LED (option)
Red lighting
PHYSICAL
Dimension (DxWxH)
180 x 95 x 114 mm
Net Weight (kgs)
1.36
1.6
1.96
Environment
Humidity
0-90 % RH @ 0-40° C (non-condensing)
Noise Level
Less than 40 dB