Greenlee 940-M3, 940-PS, 940-TB, 940-TA, 940-SA Operation, Service And Parts Instruction Manual

...
Page 1
OPERATION, SERVICE AND PARTS
INSTRUCTION MANUAL
HYDRAULIC POWER PUMP
999 6463.5 © 1997 Greenlee Textron IM 791 REV 1 7/97
Read and understand this material before operating or servicing this tool. Failure to understand how to safely operate the tool could result in an accident causing serious injury or death.
Page 2
940 Series Hydraulic P ower Pump
SAFETY ALERT
Immediate hazards which, if not avoided, WILL result in severe personal injury or death.
SYMBOL
The symbol above is used to call your attention to instructions concerning your personal safety. Watch for this symbol. It points out important safety precautions. It means “ATTENTION! Become alert! Your personal safety is involved!” Read the message that follows and be alert to the possibility of personal injury or death.
Safety is a critical factor in the design of Greenlee equipment. The best program starts with a safety-conscious operator. The information highlighted in this bulletin describes operating practices for the benefit of the workers who will use our equipment in their daily jobs. Comments from users are appreciated.
A person who has not read and does not understand all operating instructions is not qualified to operate this tool.
Hazards or unsafe practices which, if not avoided, COULD result in severe personal injury or death.
Hazards or unsafe practices which, if not avoided, COULD result in minor personal injury or property damage.
Failure to read and understand safety instructions may result in injury or death.
Greenlee Textron / Subsidiary of Textron
2
4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070
Page 3
940 Series Hydraulic P o wer Pump
IMPORTANT SAFETY INSTRUCTIONS
• Do not connect the pump to any system or system component other than those supplied by Greenlee and rated at less than 10,000 psi (68,950 kPa).
• Do not alter the internal high-pressure relief valve setting.
• Do not use this pump in a hazardous environment. Hazards include open flame and flammable liquids or gases.
Failure to observe these warnings will result in severe injury or death.
Electric shock hazard:
• Do not expose power tools to rain.
• Do not immerse the pendant switch in water or other liquid.
Skin Injection Hazard: High pressure oil easily punctures
skin causing serious injury, gangrene or death. If injured seek medical help immediately to remove oil.
Do not use fingers or hands to check for leaks.
Depressurize hydraulic system before disconnecting the hose.
• Inspect pump, hoses, couplers and fittings for wear or damage. Replace worn, damaged or missing components with Greenlee replacement parts.
• Do not twist, kink, curl, paint or cut the hydraulic hoses.
• Wear eye protection when operating this equipment.
• Disconnect the pump from the power supply, rotate the release valve lever to AUTO RELEASE and disconnect the hose from the ram and the pump before performing any service.
Failure to observe these warnings could result in severe injury or death.
• The pump is heavy, weighing up to 75 lbs. Follow NIOSH work practices for manual lifting. If in doubt, get help.
• Unplug pump when not in use and when changing accessories.
• Do not use the hose to pull, lift, or carry the equipment.
• Always work in an area providing good footing and support.
• Keep work area well-lit, free of clutter, and dry.
Failure to observe these precautions could result in injury or property damage.
SA VE THESE INSTRUCTIONS
Additional copies of this manual are available upon request at no charge.
Greenlee Textron / Subsidiary of Textron
3
4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070
Page 4
940 Series Hydraulic P ower Pump
Introduction
The 940 is a high-pressure hydraulic power pump which is simple to operate, lightweight, constructed with extreme durability and is portable. The 940 features a supercharger which provides low pressure / high volume delivery for rapid advance of the ram to the work and automatic change-over to low volume / hi-pressure delivery when ram pressure exceeds 200 psi. The pump is a one-piston radial-type capable of developing 10,000 psi. The pump unit contains two valves; one is set at 10,000 psi to control the low volume / hi-pressure delivery, and the other is set at 200 psi to control the high volume / low pressure delivery.
Assembly
The 940 pump is completely assembled and is shipped to you as a complete pumping unit. The only assembly necessary is the connections to the ram at ports pro­vided in the model purchased.
Power Connection
The 940 is shipped wired for 115 volt AC operation unless specifically ordered for 230 volt AC operation. If 230 volt AC operation is desired and your pump has not been wired at the factory for the 230 volt AC, the motor leads must be rewired in accordance with the wiring diagram shown.
For your protection, ground unit before using. The electric motor is equipped with an approved 3-conductor cord and 3-blade grounding-type attachment plug to be used with the proper grounding-type receptacle, in accordance with the National Electrical Code. The green-colored conductor in the cord is the grounding wire, which is attached to the metal frame of the unit inside the housing and to the longest blade of the attachment plug cap. A special grounding adapter is supplied (except in Canada or for use above 150 volts) to permit using two-wire receptacles until the correct receptacle is installed. The green grounding wire extending from the side of the adapter must be connected to a permanent ground such as a properly grounded outlet box, conduit or water pipe, before plugging in the unit. (If extension cords are used, they should have sufficient rated capacity and a properly connected grounding circuit.)
CONNECTIONS FOR CW ROTATION (VIEW MOTOR FROM LEAD END)
Franklin GE
Brown (10)
Violet (9)
Pink (1)
Orange (5) Black (2) Red (8) Blue (4)
Greenlee Textron / Subsidiary of Textron
Purple P1 Brown P2 Black T5 Orange T3 Yellow T4 Red J10 White T2
LOW VOLTAGE
Low
Voltage
Line
Franklin GE
Brown (10) Violet (9)
Pink (1) Orange (5)
Blue (4)
Red (8)
Black (2)
4
4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070
Purple P1 Brown P2 Black T5 Orange T3 White T2 Red J10 Yellow T4
HIGH VOLTAGE
Insulate This Lead
High
Voltage
Line
Page 5
Operating Instructions
940 Series Hydraulic P o wer Pump
This pump is designed to operate at 10,000 psi inter­mittently. For continuous service, as on production work, the pressure should not exceed 6,000 psi. (This limitation is for motor protection only.)
Before operating pump, check the following to assure proper service:
1. Check for proper power connections and for tight­ness of hose connections before starting pump.
2. Check hydraulic oil with dipstick. Oil should be within 1/2" of reservoir top.
3. Start motor and allow pump to idle a few minutes. This will allow the hydraulic oil to work into moving parts and give prime to pump.
For operation of control valves see page 8.
Servicing
Filling Oil Reservoir
The oil reservoir must be kept filled with a good grade of light hydraulic oil—Greenlee 905 0806.8 hydraulic oil or equal—in order for the pump to operate properly.
Never use synthetic fluids or fluids with poor lubri­cating qualities (i.e., brake fluids, etc.), as permanent injury to the pump will result.
Eight quarts are required, of which 6-1/4 quarts are usable. A minimum of 1-3/4 quarts must be at the bottom of the reservoir at all times during operation. Be sure that your complete operation does not require more than the usable amount of oil.
To refill or add oil to the reservoir, proceed as follows:
1. Remove vent unit from top of reservoir (B).
2. Add oil to within 1/2" of top of reservoir when ram is retracted.
3. Install vent unit securely in place.
Draining Oil Reservoir
Unscrew and remove 3/4 inch pipe plug (56) from side of pump base. Turn pump on its side to drain all oil from reservoir. Be sure to replace plug before refilling reser­voir with oil.
Flushing System
As long as the pump is used as outlined in the operating instructions, long, trouble-free performance can be expected. To maintain this performance, it is absolutely essential that dirt or other foreign matter be kept out of the system, as this is the most common cause of hydraulic system failure. Therefore, when opening up the pump for any reason, such as making pipe connec­tions, adjusting pressure or any repair, be sure to exercise extreme care in cleanliness and to use clean tools and cloths. If, at any time, dirt is suspected to have found its way into the system, the entire oil system should be flushed as follows:
1. Drain oil from reservoir.
2. Fill reservoir with any recommended flushing oil or clean kerosene and operate pump. Work the control handle back and forth several times during flushing to wash all foreign particles from the control valve unit.
Note: Do not operate pump for a very long time as
system is not designed to operate with flushing oil or kerosene.
3. Drain flushing oil or kerosene from reservoir and refill with new oil.
Check to see that vent unit is not clogged before attempting to operate pump.
Greenlee Textron / Subsidiary of Textron
5
4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070
Page 6
940 Series Hydraulic P ower Pump
Pump Specifications
Model Motor Pumping Capacity Height Base Dia. Weight
(Cu. In./Min)
940
Type Horse Volts 100 10,000
Power psi psi
AC 1 hp 115/230 150 30
20-9/16" 12" x 71 lbs.
10-1/2" approx.
Motor Maintenance
If the pump motor is in need of repair, it should be done by the manufacturer of the motor or a qualified service center.
Correcting Minor Hydraulic Problems
The hydraulic unit should be observed constantly for out-of-the-ordinary performance and unusual noises. If any of these are present, shut off pump and take corrective steps immediately to avoid possible expen­sive repairs later on. See Troubleshooting charts for some of the most common minor troubles and their solutions.
Greenlee Textron / Subsidiary of Textron
6
4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070
Page 7
940 Series Hydraulic P o wer Pump
Troubleshooting
PROBLEM PROBALE CAUSE POSSIBLE REMEDY
Improper advance or return. Air in circuit, oil supply low. Add oil. Run unit to work out air.
Dirt in system, causing valves to Flush out entire oil system and lock open. fill with new oil (see page 5).
If trouble is not cleared up by above Drain oil (see page 5). Next remedies, trouble may be due to dirty remove pumping unit cover or plugged-up screen. and clean or replace screen (17).
CAUTION: Do not operate pump without screens, as particles of dirt will be sucked into pump and valve mechanisms, seriously damaging valve seats.
Unable to reach pressure. Same as above. Same as above.
Necessary to add oil often. Oil leaks. Check for broken lines, loose fittings
or connections.
Noise in hydraulic system. Air in system. Low in oil. Add oil (page 5). Run pump to work
out air.
If the above corrective measures fail to make the pump function properly, it is recommended that you send the pump back to the factory or to an authorized Greenlee service center. Under no conditions, allow unqualified personnel to attempt to repair the pump (particularly the pump block unit or control valve unit), as serious irreparable damage may result.
Greenlee Textron / Subsidiary of Textron
7
4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070
Page 8
940 Series Hydraulic P ower Pump
The 940 Hydraulic Pump with Control Valves
940-TA Pump
This pump is equipped with a four-way control valve, panel-mounted, for operating double-acting rams. This valve has two 3/8" NPT outlet ports. The lower port is for the forward, or advance, stroke with a maximum pressure of 10,000 psi. The upper port is for the return stroke of the ram at a maximum pressure of 200 psi. The control handle has three positions: Advance (turn handle counterclockwise to extreme position), Return (turn handle clockwise to extreme position), Neutral is in the middle of these two positions.
This is a positive seat type valve and therefore position­ing of the valve in the advance position must be done firmly to make the seating effective. If stopping the ram and holding the ram pressure during the advance operation is required, snap the starting switch on motor to OFF. The pressure should then be held for a sus­tained period. (See page 9 for TA valve 501 2106.5, Key E.)
Note: This valve is designed to return the ram piston
only when there is no load on the ram. If the operation requires the return of the piston while sustaining a load the TB control valve should be used.
940-SA Pump
This pump is equipped with a control valve for operating single-acting rams. It has one 3/8" NPT outlet port. This model is used when the ram has spring, manual, or gravity return. It also has a holding feature, whereby the ram is held stationary under pressure (with motor running) when the control handle is in Neutral position.
The control valve has three positions. Advance (turn control handle counterclockwise to extreme position), Neutral, or Hold, (turn control handle clockwise to middle position), and Return (turn control handle clockwise to extreme position). When the control handle is in Neutral position the pump is unloaded but the ram pressure is held. (See page 7 for SA Valve 501 5644.6, Key D.)
940-TB Pump
This pump is equipped with a 1704 spool valve with sub-plate panel-mounted, and is used for operating double-acting ram.
The spool is spring-returned to Neutral from Advance and Return positions. The sub-plate has two 3/8" NPT ports, marked Cyl. 1 and Cyl. 2. Cylinder 1 port is the high pressure port and should be connected to the advance port in the ram. Cylinder 2 is the return port, 750 psi maximum, and should be connection to the return port in the ram.
To advance the ram, push the control lever forward (toward the valve body) to its extreme position. To return the ram, pull the control lever away from the valve body. Because of the balanced design of this valve it will be noted that it operates as easily under full load as at no load. At no time is great effort required to move the lever.
The above 1704 spool valve and 501 2256.8 sub-plate with relief valve are standard equipment on the 940-TB pump. On special order the pump can be supplied with a 501 2441.2 sub-plate without relief valve which will deliver 10,000 psi through both cylinder ports. Also available on special order is the 1717 4-way control valve in which the spool is detent held in position. (See page 7 for Valve 1704 [F] and Sub-Plate 501 2256.8[G].)
Greenlee Textron / Subsidiary of Textron
8
4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070
Page 9
940 Series Pumps
940 Series Hydraulic P o wer Pump
F
G
940-TB
E
940-TA
940-SA
940
D
C
940-BASIC
Greenlee Textron / Subsidiary of Textron
9
4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070
Page 10
940 Series Pumps (cont’d)
50
940 Series Hydraulic P ower Pump
46 39
53
42 48 45 52 41
54
49
51
43
Greenlee Textron / Subsidiary of Textron
10
47
A
38
2729
4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070
Page 11
940 Series Pumps
940 Series Hydraulic P o wer Pump
10.75
56 40 44 55
5.37
9.50
36
B
37
Greenlee Textron / Subsidiary of Textron
SECTION CC
11
4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070
Page 12
940 Series Pumps (cont’d)
33 22
16 23 12
940 Series Hydraulic P ower Pump
15
35
32
21
31 13 34 26 18 23 28
1
11
19 14 5
10 30
9
20
3 4
25
24 6 17 7 8
Greenlee Textron / Subsidiary of Textron
SECTION BB
12
4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070
28
2
Page 13
940 Series Hydraulic P o wer Pump
940 Series Hydraulic Power Pump — Parts List
Key Part No. Description Qty
A 501 5693.4 Block Unit, Pump (#1-35) .............................................................................. 1
1 501 1732.7. Valve Unit, Lo-Pressure Relief......................................................................1
2 500 6067.8 Valve Unit, Relief...........................................................................................1
3 501 4854.0 Pump Block ................................................................................................... 1
4 501 4857.5 Plate, Pump Mounting................................................................................... 1
5 501 4876.1 Shaft, Eccentric .............................................................................................1
6 501 4859.1 Block, Intake.................................................................................................. 1
7 501 4860.5 Plate, Cover...................................................................................................1
8 501 4861.3 Plate, Pump................................................................................................... 1
9 501 1852.8 Spacer, Bearing ............................................................................................. 1
10 501 1855.2 Race, Outer ................................................................................................... 1
11 501 1862.5 Plug, Hi-Pressure Plunger ............................................................................ 1
12 501 1863.3 Plunger, Hi-Pressure.....................................................................................1
13 501 1864.1 Bushing, Hi-Pressure Plunger.......................................................................1
14 501 4862.1 Key, Lo-Pressure Pump ................................................................................1
15 501 2621.0 Adapter, Drive Shaft......................................................................................1
16 500 6111.9 Spring, Compression (discharge) .................................................................1
17 501 3179.6 Screen, Intake ............................................................................................... 1
18 501 4865.6 Spring, Compression (intake) .......................................................................1
19 501 4867.2 Gerotor Pump Elements............................................................................ Set
20 501 0989.7 Bearing, .7874 ID x 2.0472 OD x .5906 Thick..............................................1
21 905 0991.9 Bearing, .9843 ID x 2.0472 OD x .5906 Thick..............................................1
22 905 0410.0 O-Ring, 3/8 x 1/2 x 1/16 ................................................................................ 1
23 905 0436.4 Ball, 9/32 Dia. ................................................................................................2
24 905 0992.7 Nipple, 3/8 NPT x 1-1/2 Black Pipe ..............................................................1
25 905 0577.8 Screw, #10-32 NF x 3/4 Socket Head Cap................................................... 4
26 905 0681.2 Ball, 3/8 Dia. ..................................................................................................1
27 905 0685.5 Washer, #8 Lock ...........................................................................................4
28 905 0824.6 Plug, 1/16 NPT Pipe...................................................................................... 2
29 905 0994.3 Screw, #8-32 NC x 1-1/4 Socket Head Cap ................................................. 4
30 502 2611.8 Roller, .125 x .750 .......................................................................................30
31 905 0912.9 O-Ring, 1/2 x 5/8 x 1/16 ................................................................................ 1
32 905 0320.1 Seal, 1-3/8 ID x 2-3/8 OD x 7/16 Thick Oil ...................................................1
33 905 1097.6 O-Ring, 3 x 3-1/4 x 1/8 ..................................................................................1
34 905 1111.5 Screw, 7/16-20 NF x 1/2 Cup Point Socket Set ........................................... 1
35 905 0390.2 Ring, 2-3/8 Dia. Internal Retaining................................................................1
B 501 3076.5 Plug Unit, Vent (#36 & 37) ............................................................................1
36 905 0319.8 DRAIN COCK................................................................................................1
37 905 0428.3 Bushing, 3/4 x 1/4 Hex Steel Pipe ................................................................ 1
38 501 5695.0 Reservoir ....................................................................................................... 1
39 501 5697.7 Plate, Motor Mounting ...................................................................................1
40 501 3918.5 Handle ...........................................................................................................1
41 501 5646.2 Dipstick ..........................................................................................................1
42 501 4852.4 Key ................................................................................................................1
43 501 5701.9 Gasket, Reservoir ......................................................................................... 1
44 905 0327.9 Screw, #10-32 NF x 5/8 Socket Head Cap................................................... 2
45 905 0506.9 Washer, 3/8 Lock ..........................................................................................7
46 905 0530.1 Screw, 3/8-16 NC x 1" Hex Head Cap.......................................................... 4
47 905 0713.4 O-Ring, 1/2 x 11/16 x 3/32 ............................................................................1
48 905 0051.2 Screw, 3/8-24 NF x 2" Socket Head Cap .....................................................3
49 918 5264.1 Cord, 10 ft...................................................................................................... 1
50 918 5183.1 Motor ............................................................................................................. 1
51 918 5223.4 Adapter ..........................................................................................................1
52 905 0522.0 Screw, 5/16-18 NC x 1" Hex Head Cap........................................................ 3
53 918 5284.6 Switch, Toggle...............................................................................................1
54 918 5117.3 Connector, Two Screw..................................................................................1
55 905 0300.7 Washer, #10 x .112 x .068 Lock ...................................................................2
56 905 0503.4 Plug, 3/8 NPTF Pipe ..................................................................................... 1
65 905 0806.8 Oil ......................................................................................................1 qt. can
66 905 1059.3 Oil .................................................................................................... 1 gal. can
When ordering parts,
give serial no. of pump
Greenlee Textron / Subsidiary of Textron
13
4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070
Page 14
Parts - Hydraulic P ower Pumps (cont’d)
940 501 5679.9 Hydraulic Pump (includes #A through 56 plus C)
Key Control No. Description
C 501 6152.0 Hose Connection Unit
940-SA 501 5680.2 Hydraulic Pump (includes #A through 56 plus D)
Key Control No. Description
D 501 5644.6 SA Control Valve Unit
(see IM 790 for parts)
940-TA 501 5681.0 Hydraulic Pump (includes #A through 56 plus E)
Key Control No. Description
E 501 2106.5 TA Control Valve Unit
(see A-684-IM for parts
940-TB 501 5682.9 Hydraulic Pump (includes #A through 56 plus F & G)
Key Control No. Description
F 500 2781.6 4-way Spring-Centered Spool Valve
(1704) (see IM 686-B for parts)
G 501 2256.8 Sub-Plate Unit
(see IM 686-B for parts)
GREENLEE
Greenlee Textron / Subsidiary of Textron Inc.
4455 Boeing Drive, Rockford, IL 61109-2988 USA
General Offices: 815/397-7070
Customer Center and Field Service: 800/435-0786
International Customer Service: 815/397-7070
Fax (24 Hour) Customer Center: 800/451-2632 • 815/397-1865
Canada Fax (24 Hour) Customer Center: 800/524-2853
International Fax (24 Hour) Customer Service: 815/397-1391
Printed in U.S.A.
Loading...