Greenheck EACA-601 User Manual

Combination Louver/Damper
Airfoil Blade
Application and Design
EACA-601 is a combination louver/damper designed to protect air intake and exhaust openings in building exterior walls that, at times, require tight air shut off. Design incorporates a drainable head member, drainable stationary blades and operable airfoil blades. When the operable blades are open, airflow is permitted through the louver, when the blades are closed, a tight seal is created to prevent the passage of air. The EACA-601 is an extremely efficient louver with AMCA LICENSED PERFORMANCE DATA enabling designers to select and apply with confidence.
Standard Construction
Frame . . . . . . . .Heavy gauge extruded 6063-T5 aluminum,
6 in. x 0.125 in. nominal wall thickness
Blades . . . . . . . .Stationary blade: drainable design, heavy gauge extruded
6063-T5 aluminum, 0.081 in. nominal wall thickness, positioned at 45º angles on approximately 5 in. centers Operable blade: airfoil design, heavy gauge extruded 6063-T5 aluminum, 0.063 nominal wall thickness
Seals . . . . . . . . .TPE blade seals
Compressible stainless steel jamb seals
Temperature
Restrictions . . . .(-20º F) - (+180ºF)
Linkage . . . . . . .Side linkage, out of airstream (concealed in frame)
Bearings . . . . . .Synthetic sleeve type
Axles . . . . . . . . .½ in. dia. zinc plated steel
Construction . . .Mechanically fastened
Birdscreen . . . . .3/4 in. x 0.051 in. fl attened expanded aluminum in
removable frame, inside mount (rear)
Finish . . . . . . . . .Mill
Minimum Size . . 12 in. W x 16 in. H
Maximum Single Section Size . . . 60 in. W x 96 in. H
EACA-601
Options (at additional cost)
• A variety of bird and insect screens
• A variety of electric, pneumatic or manual actuators
• Clip angles
• Extended sill
• Filter rack
• Flanged frame
• Glazing adaptor
• Hinged frame
• Security bars
• A variety of architectural finishes including: Clear anodize Integral color anodize Baked enamel paint Kynar paint
*Width and height dimensions furnished
approximately ¼ inch under size.
Free Area Chart (Sq. ft.)
Louver Height Inches
12 15 18 21 24 27 30 33 36 39 42 48 54 60
16 0.20 0.27 0.33 0.40 0.46 0.53 0.59 0.66 0.72 0.79 0.85 0.98 1.11 1.24
21 0.40 0.52 0.65 0.78 0.91 1.04 1.17 1.30 1.42 1.55 1.68 1.94 2.20 2.45
24 0.59 0.78 0.98 1.17 1.36 1.55 1.74 1.94 2.13 2.32 2.51 2.90 3.28 3.66
30 0.79 1.04 1.30 1.55 1.81 2.06 2.32 2.58 2.83 3.09 3.34 3.85 4.36 4.87
33 0.97 1.28 1.60 1.91 2.22 2.54 2.85 3.17 3.48 3.79 4.11 4.74 5.37 5.99
39 1.18 1.56 1.94 2.33 2.71 3.09 3.47 3.85 4.24 4.62 5.00 5.77 6.53 7.30
42 1.34 1.77 2.21 2.64 3.07 3.51 3.94 4.38 4.81 5.24 5.68 6.55 7.41 8.28
48 1.57 2.08 2.59 3.10 3.61 4.12 4.62 5.13 5.64 6.15 6.66 7.68 8.70 9.72
51 1.57 2.08 2.59 3.10 3.61 4.12 4.62 5.13 5.64 6.15 6.66 7.68 8.70 9.72
60 1.96 2.60 3.23 3.87 4.51 5.14 5.78 6.41 7.05 7.69 8.32 9.59 10.87 12.14
66 2.33 3.08 3.84 4.59 5.35 6.10 6.85 7.61 8.36 9.12 9.87 11.38 12.89 14.40
78 2.74 3.63 4.52 5.41 6.30 7.19 8.08 8.97 9.86 10.75 11.64 13.42 15.20 16.98
84 2.94 3.89 4.85 5.80 6.75 7.71 8.66 9.61 10.56 11.52 12.47 14.38 16.28 18.19
96 3.53 4.67 5.81 6.96 8.10 9.24 10.39 11.53 12.67 13.82 14.96 17.25 19.54 21.82
Greenheck Fan Corporation certifies that the EACA­601 louvers shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance and water penetration ratings.
Louver Width in Inches
Water Penetration (Standard Air - .075 lb/ft
Test size 48 in. x 48 in. Test duration of 15 min.
EACA-601PERFORMANCE DATA
Combination Louver/Damper
Extruded Aluminum
Air Leakage (with damper section closed)
Test size 48 in. x 48 in.
kPa
in. wg
2
0.475
0.45
0.425 1
0.9
0.4
0.8
0.7
0.375
0.6
0.35
0.5
0.4
0.325
Pressure
0.3
0.3
0.2
0.275
0.25
0.1
0.225
0.09
2
112345678910
cfm/ft
2
cmh/m
20 30 40 50 60 70 80 90 100 200
Leakage
3
)
Airflow Resistance (Standard Air - .075 lb/ft
Pa
in. wg
1
0.9
200
100
90 80
70
60
50
40
30
20
Static Pressure Drop
10
9 8
7
6
5
ft/min:
m/s:
Test Size 48 in. x 48 in.
0.8
Standard Air - .075 lb/ft
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.09
0.08
0.07
0.06
0.05
0.04
0.03
0.02
200 300 400 500 600 700 800 9001000 2000 3000
3
Intake
Exhaust
2345678910
3
)
Free Air Velocity
Model EACA-601 resistance to airflow (pressure drop) varies depending on louver application (air intake or air exhaust). Free area velocities (shown) are higher than average velocity through the overall louver size. See louver selection information.
ml/m2
oz/ft2
0.30
Test Size 48 in. x 48 in.
80
60
40
20
Water Penetration per Unit Free Area
0
ft/min:
m/s:
Test Period 15 minutes
0.25
Standard Air - .075 lb/ft
0.20
0.15
0.10
0.05
0.00
1100 1150 1200 1250 1300
5.5 6.0 6.5
3
Free Area Velocity
The AMCA Water Penetration Test provides a method for comparing various louver models and designs as to their efficiency in resisting the penetration of rainfall under specific laboratory test conditions. The beginning point of water penetration is defined as that velocity where the water penetration curve projects through .01 oz. of water (penetration) per sq. ft. of louver free area.
penetration for Model EACA-601 is 1221 fpm free area velocity.
The beginning point of water
*
These perfor mance ratings do not guarantee a louver to be weather proof or stormproof and should be used in combination with other factors including good engineering judgement in selecting louvers.
EACA-601INSTALLATION DETAILS
Maximum Size and Installation Information
The maximum single section size for the EACA-601 is 60 in. W x 96 in. H. Larger openings require field assembly of multiple louver panels to make up the overall opening size. Individual louver panels are designed to withstand a 25 PSF wind-load (please consult Greenheck if the louvers must withstand higher wind-loads). Structural reinforcing members may be required to adequately support and install multiple louver panels within a large opening. Structural reinforcing members along with any associated installation hardware is not provided by Greenheck unless indicated otherwise by Greenheck. Additional information on louver installation may be found in AMCA Publication #501, Louver Application Manual.
Combination Louver/Damper
Extruded Aluminum
Minimum Single Section Size
12 in. W x 16 in. H
Maximum Single Section Size
60 in. W x 96 in. H
EACA-601PRODUCT DETAILS
Combination Louver/Damper
Extruded Aluminum
EACA-601OPTION DRAWINGS
Combination Louver/Damper
Extruded Aluminum
FINISHES
Finish Type Description/Application Color Selection
2-coat 70% KYNAR 500®/HYLAR 5000® AAMA 2605 –
Dry fi lm thickness 1.2 mil. (AKA: Duranar®, Fluoropon®, Trinar®, Flouropolymer, Polyvinylidene Fluoride, PVDF2)
2-coat 50% KYNAR 500®/HYLAR 5000® AAMA 2604 – Dry fi lm thickness 1.2 mil. (AKA: Acrofl ur®, Acrynar®)
Baked Enamel AAMA 2603 – Dry fi lm thickness 0.8 mil. (AKA: Acrabond Plus®, Duracron®)
Integral Color Anodize AA-M10C22A42 (>0.7 mil)
Clear Anodize 215 R-1 AA-M10C22A41 (>0.7 mil)
Clear Anodize 204 R-1 AA-M10C22A31 (0.4-0.7 mil)
Industrial coatings
Mill
“Best.” The premier fi nish for extruded aluminum. Tough, long-lasting coating has superior color retention and abrasive properties. Resists chalking, fading, chemical abrasion and weathering.
“Better.” Tough, long-lasting coating has excellent color retention and abrasive properties. Resists chalking, fading, chemical abrasion and weathering.
“Good.” Provides good adhesion and resistance to weathering, corrosion and chemical stain.
“Two-step” anodizing is produced by following the normal anodizing step with a second, colorfast process.
Clear, colorless and hard oxide aluminum coating that resists weathering and chemical attack.
Clear, colorless and hard oxide aluminum coating that resists weathering and chemical attack.
Greenheck offers a number of industrial coatings such as Hi-Pro Polyester, Epoxy, and Permatector®. Consult a Greenheck Product Specialist for complete color and application information.
Materials may be supplied in natural aluminum or galvanized steel fi nish when normal weathering is acceptable and there is no concern for color or color change.
Finishes meet or exceed AAMA 2605, AAMA 2604, and AAMA 2603 requirements. Please consult www.greenheck.com for complete information on standard and extended paint warranties. Paint fi nish warranties are not applicable to steel products.
Standard Colors: Any of the 24 standard colors shown can be furnished in 70% or 50% KYNAR 500®/HYLAR 5000® or Baked Enamel.
2-Coat Mica:
Greenheck offers 9 standard 2­coat Mica colors. Other colors are available. Consult Greenheck for possible extra cost when selecting non-standard colors or special fi nishes.
Light, Medium or Dark Bronze; Champagne; Black
Clear 5 years
Clear 1 Year
Copyright © 2007 Greenheck Fan Corporation
Standard Warranty
(Aluminum)
10 Years (Consult Greenheck for availability of extended
warranty)
5 Years
1 Year
5 years
Consult Greenheck
n/a
EACA-601
September 2007 Rev. 3
Greenheck Fan Corporation reserves the right
to make product changes without notice.