Combination Louver/Damper
Drainable Blade
Application and Design
EAC-401 is a combination louver/damper designed to protect air intake and exhaust openings in building exterior walls that, at times, require tight air shut off. Design incorporates a drainable head member, drainable stationary blades and operable blades. When the operable blades are open, airflow is permitted through the louver, when the blades are closed, a tight seal is created to prevent the passage of air. The EAC-401 is an extremely efficient louver with AMCA LICENSED PERFORMANCE DATA enabling designers to select and apply with confidence.
Standard Construction
Frame . . . . . . . .Heavy gauge extruded 6063-T5 aluminum,
4 in. x 0.125 in. nominal wall thickness
Blades . . . . . . . .Drainable design, heavy gauge extruded
6063-T5 aluminum, 0.081 in. nominal wall thickness, positioned at 45º angles on approximately 4 in. centers
Seals . . . . . . . . .Dual-durometer extruded vinyl blade seals
Compressible stainless steel jamb seals
Temperature
Restrictions . . . .(-20º F) - (+180ºF)
Linkage . . . . . . .Side linkage, out of airstream (concealed in frame)
Bearings . . . . . .Synthetic sleeve type
Axles . . . . . . . . .½ in. dia. zinc plated steel
Construction . . .Mechanically fastened
Birdscreen . . . . .3/4 in. x 0.051 in. fl attened expanded aluminum in
removable frame, inside mount (rear)
Finish . . . . . . . . .Mill
Minimum Size . . 12 in. W x 12 in. H
Maximum Single Section Size . . . 60 in. W x 96 in. H
Options (at additional cost)
• A variety of bird and insect screens
• A variety of electric, pneumatic or manual actuators
• Clip angles
• Extended sill
• Filter rack
• Flanged frame
• Glazing adaptor
• Hinged frame
• Security bars
• A variety of architectural finishes including: Clear anodize Integral color anodize Baked enamel paint Kynar paint
*Width and height dimensions furnished
approximately ¼ inch under size.
EAC-401
WATER
PENETRATION
AIR
PERFORMANCE
AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC.
®
Page 2
Free Area Chart (Sq. ft.)
Louver Height Inches
12 15 18 21 24 27 30 33 36 39 42 48 54 60
12 0.06 0.08 0.10 0.12 0.14 0.15 0.17 0.19 0.21 0.23 0.25 0.29 0.32 0.36
18 0.22 0.29 0.36 0.42 0.49 0.56 0.63 0.70 0.77 0.84 0.91 1.04 1.18 1.32
21 0.38 0.49 0.61 0.73 0.85 0.97 1.09 1.21 1.33 1.44 1.56 1.80 2.04 2.28
27 0.53 0.70 0.87 1.04 1.21 1.38 1.55 1.71 1.88 2.05 2.22 2.56 2.89 3.23
30 0.69 0.91 1.13 1.35 1.57 1.78 2.00 2.22 2.44 2.66 2.88 3.31 3.75 4.19
36 0.85 1.12 1.39 1.66 1.92 2.19 2.46 2.73 3.00 3.27 3.53 4.07 4.61 5.15
39 1.01 1.33 1.64 1.96 2.28 2.60 2.92 3.24 3.56 3.87 4.19 4.83 5.47 6.10
45 1.17 1.53 1.90 2.27 2.64 3.01 3.38 3.74 4.11 4.48 4.85 5.59 6.32 7.06
48 1.32 1.74 2.16 2.58 3.00 3.42 3.83 4.25 4.67 5.09 5.51 6.34 7.18 8.02
54 1.48 1.95 2.42 2.89 3.35 3.82 4.29 4.74 5.23 5.70 6.16 7.10 8.04 8.97
60 1.80 2.37 2.93 3.50 4.07 4.64 5.21 5.77 6.34 6.91 7.48 8.61 9.75 10.89
72 2.11 2.78 3.45 4.12 4.79 5.45 6.12 6.79 7.46 8.12 8.79 10.13 11.46 12.80
78 2.43 3.20 3.97 4.73 5.50 6.27 7.01 7.80 8.57 9.34 10.11 11.64 13.18 14.71
90 2.75 3.61 4.48 5.35 6.22 7.08 7.95 8.82 9.69 10.55 11.40 13.16 14.89 16.63
96 3.06 4.03 5.00 5.96 6.93 7.90 8.87 9.83 10.80 11.77 12.74 14.67 16.61 18.54
Greenheck Fan Corporation certifies that the EAC­401 louvers shown herein are licensed to bear the
PENETRATION
PERFORMANCE
AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC.
and procedures performed in accordance with AMCA
AIR
Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA
®
Certified Ratings Seal applies to air performance and
AMCA Seal. The ratings shown are based on tests
WATER
water penetration ratings.
Airflow Resistance (Standard Air - .075 lb/ft
Pa
in. wg
1
0.9
200
100
90
80
70
60
50
40
30
20
Static Pressure Drop
10
9 8
7
6
5
ft/min:
m/s:
Model EAC-401 resistance to airflow (pressure drop) varies depending on louver application (air intake or air exhaust). Free area velocities (shown) are higher than average velocity through the overall louver size. See louver selection information.
Test Size 48 in. x 48 in.
0.8
Standard Air - .075 lb/ft
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.09
0.08
0.07
0.06
0.05
0.04
0.03
0.02
200 300 400 500 600 7008009001000 2000 3000
3
Exhau
2345678910
Free Air Velocity
Louver Width in Inches
st
Intake
Water Penetration (Standard Air - .075 lb/ft
Test size 48 in. x 48 in. Test duration of 15 min.
3
)
Water Penetration per Unit Free Area
The AMCA Water Penetration Test provides a method for comparing various louver models and designs as to their efficiency in resisting the penetration of rainfall under specific laboratory test conditions. The beginning point of water penetration is defined as that velocity where the water penetration curve projects through .01 oz. of water (penetration) per sq. ft. of louver free area.
penetration for Model EAC-401 is 1192 fpm free area velocity.
These perfor mance ratings do not guarantee a louver to be weather proof or stormproof and should be used in combination with other factors including good engineering judgement in selecting louvers.
Combination Louver/Damper
Air Leakage (with damper section closed)
Test size 48 in. x 48 in.
kPa
in. wg
2
0.475
0.45
0.425 1
0.9
0.4
0.8
0.7
0.375
0.6
0.35
0.5
0.4
0.325
Pressure
0.3
0.3
0.2
0.275
0.25
0.1
0.225
0.09
2
112345678910
cfm/ft
2
cmh/m
20 30 40 50 60 70 80 90100 200
ml/m2
oz/ft2
0.30
Test Size 48 in. x 48 in.
80
60
40
20
0
ft/min:
Test Period 15 minutes
0.25
Standard Air - .075 lb/ft
0.20
0.15
0.10
0.05
0.00
1100 1150 1200 1250 1300
m/s:
5.5 6.5
3
Free Area Velocity
The beginning point of water
*
EAC-401PERFORMANCE DATA
Extruded Aluminum
Leakage
3
)
Page 3
EAC-401INSTALLATION DETAILS
Maximum Size and Installation Information
The maximum single section size for the EAC-401 is 60 in. W x 96 in. H. Larger openings require field assembly of multiple louver panels to make up the overall opening size. Individual louver panels are designed to withstand a 25 PSF wind-load (please consult Greenheck if the louvers must withstand higher wind-loads). Structural reinforcing members may be required to adequately support and install multiple louver panels within a large opening. Structural reinforcing members along with any associated installation hardware is not provided by Greenheck unless indicated otherwise by Greenheck. Additional information on louver installation may be found in AMCA Publication #501, Louver Application Manual.
Combination Louver/Damper
Extruded Aluminum
Minimum Single Section Size
12 in. W x 12 in. H
Maximum Single Section Size
60 in. W x 96 in. H
Page 4
EAC-401PRODUCT DETAILS
Combination Louver/Damper
Extruded Aluminum
Page 5
EAC-401OPTION DRAWINGS
Combination Louver/Damper
Extruded Aluminum
FINISHES
Finish Type Description/Application Color Selection
2-coat 70% KYNAR 500®/HYLAR 5000® AAMA 2605 –
Dry fi lm thickness 1.2 mil. (AKA: Duranar®, Fluoropon®, Trinar®, Flouropolymer, Polyvinylidene Fluoride, PVDF2)
2-coat 50% KYNAR 500®/HYLAR 5000® AAMA 2604 – Dry fi lm thickness 1.2 mil. (AKA: Acrofl ur®, Acrynar®)
Baked Enamel AAMA 2603 – Dry fi lm thickness 0.8 mil. (AKA: Acrabond Plus®, Duracron®)
Integral Color Anodize AA-M10C22A42 (>0.7 mil)
Clear Anodize 215 R-1 AA-M10C22A41 (>0.7 mil)
Clear Anodize 204 R-1 AA-M10C22A31 (0.4-0.7 mil)
Industrial coatings
Mill
“Best.” The premier fi nish for extruded aluminum. Tough, long-lasting coating has superior color retention and abrasive properties. Resists chalking, fading, chemical abrasion and weathering.
“Better.” Tough, long-lasting coating has excellent color retention and abrasive properties. Resists chalking, fading, chemical abrasion and weathering.
“Good.” Provides good adhesion and resistance to weathering, corrosion and chemical stain.
“Two-step” anodizing is produced by following the normal anodizing step with a second, colorfast process.
Clear, colorless and hard oxide aluminum coating that resists weathering and chemical attack.
Clear, colorless and hard oxide aluminum coating that resists weathering and chemical attack.
Greenheck offers a number of industrial coatings such as Hi-Pro Polyester, Epoxy, and Permatector®. Consult a Greenheck Product Specialist for complete color and application information.
Materials may be supplied in natural aluminum or galvanized steel fi nish when normal weathering is acceptable and there is no concern for color or color change.
Finishes meet or exceed AAMA 2605, AAMA 2604, and AAMA 2603 requirements. Please consult www.greenheck.com for complete information on standard and extended paint warranties. Paint fi nish warranties are not applicable to steel products.
Standard Colors: Any of the 24 standard colors shown can be furnished in 70% or 50% KYNAR 500®/HYLAR 5000® or Baked Enamel.
2-Coat Mica:
Greenheck offers 9 standard 2­coat Mica colors. Other colors are available. Consult Greenheck for possible extra cost when selecting non-standard colors or special fi nishes.
Light, Medium or Dark Bronze; Champagne; Black
Clear 5 years
Clear 1 Year
Copyright © 2007 Greenheck Fan Corporation
Standard Warranty
(Aluminum)
10 Years (Consult Greenheck for availability of extended
warranty)
5 Years
1 Year
5 years
Consult Greenheck
n/a
EAC-401
September 2007 Rev. 1
Greenheck Fan Corporation reserves the right
to make product changes without notice.
Loading...