Greenheck AX 41-190 User Manual

AX 41-160 4 Blades
Total
Pressure
Impeller Diameter = 16.25 inches 413 mm
Outlet Velocity Ft/Min = Volume / 1.44
M/S = Volume / 0.13
Tip Speed Ft/Min = RPM X 4.25
M/S = RPM X 1.30
77
72
75
76
74
77
76
75
76
Air density = 1.2 kg/m Air density = 0.075 lbs/ft
Peak Absorbed Power [bHP/kw (60 Hz), kw (50 Hz)]
RPM 5 10 15 20 25 30 35 3500 (bHP/kw) 0.78/0.58 1.21/0.90 1.76/1.31 2.36/1.76 3.02/2.25 3.73/2.78 4.52/3.37 1770 (bHP/kw) 0.10/0.08 0.16/0.12 0.23/0.17 0.31/0.23 0.39/0.29 0.48/0.36 0.58/0.44 2900 (kw) 0.33 0.51 0.74 1.00 1.28 1.58 1.92 1450 (kw) 0.04 0.06 0.09 0.13 0.16 0.20 0.24
Sound power level ratings are shown in decibels, referred to 10-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwA sound power levels for 100%, 50% and 0% of peak pressure in Installation Type B: free inlet, ducted outlet. dBA sound pressure values are weighted with 11.5 dB attenuation for each octave band at 5 feet.
8
3
3
Pitch Angle º
Volume
Sound Power A-Weighted [LwA] Sound Pressure [dBA]
Inlet Sound RPM LwA dBA 3500 +18 +6.5 1770 - -11.5 2900 +12 +0.5 1450 -6 -17.5
Total
Pressure
AX 41-160 6 Blades
Impeller Diameter = 16.25 inches 413 mm
Outlet Velocity Ft/Min = Volume / 1.44
M/S = Volume / 0.13
Tip Speed Ft/Min = RPM X 4.25
M/S = RPM X 1.30
76
73
77
77
75
78
77
77
78
Air density = 1.2 kg/m Air density = 0.075 lbs/ft
Peak Absorbed Power [bHP/kw (60 Hz), kw (50 Hz)]
RPM 5 10 15 20 25 30 35 3500 (bHP/kw) 1.11/0.82 1.76/1.32 2.44/1.82 3.15/2.35 3.90/2.91 4.76/3.55 5.76/4.30 1770 (bHP/kw) 0.14/0.11 0.23/0.17 0.32/0.24 0.41/0.30 0.51/0.38 0.62/0.46 0.75/0.56 2900 (kw) 0.47 0.75 1.04 1.34 1.66 2.02 2.44 1450 (kw) 0.06 0.09 0.13 0.17 0.21 0.25 0.31
3
3
Pitch Angle º
Volume
Sound Power A-Weighted [LwA] Sound Pressure [dBA]
Inlet Sound RPM LwA dBA 3500 +16 +4.5 1770 - -11.5 2900 +12 +0.5 1450 -7 -18.5
Sound power level ratings are shown in decibels, referred to 10-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwA sound power levels for 100%, 50% and 0% of peak pressure in Installation Type B: free inlet, ducted outlet. dBA sound pressure values are weighted with 11.5 dB attenuation for each octave band at 5 feet.
9
AX 41-190 4 Blades
Total
Pressure
Impeller Diameter = 16.25 inches 413 mm
Outlet Velocity Ft/Min = Volume / 1.44
M/S = Volume / 0.13
Tip Speed Ft/Min = RPM X 4.25
M/S = RPM X 1.30
77
77
73
78
76
77
74
78
75
Air density = 1.2 kg/m Air density = 0.075 lbs/ft
Peak Absorbed Power [bHP/kw (60 Hz), kw (50 Hz)]
RPM 5 10 15 20 25 30 35 3500 (bHP/kw) 0.80/0.60 1.24/0.92 1.79/1.34 2.43/1.81 3.11/2.32 3.81/2.84 4.55/3.40 1770 (bHP/kw) 0.10/0.08 0.16/0.12 0.23/0.17 0.31/0.23 0.40/0.30 0.49/0.37 0.59/0.44 2900 (kw) 0.34 0.52 0.76 1.03 1.32 1.62 1.93 1450 (kw) 0.04 0.07 0.10 0.13 0.16 0.20 0.24
Sound power level ratings are shown in decibels, referred to 10-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwA sound power levels for 100%, 50% and 0% of peak pressure in Installation Type B: free inlet, ducted outlet. dBA sound pressure values are weighted with 11.5 dB attenuation for each octave band at 5 feet.
10
3
3
Pitch Angle º
Volume
Sound Power A-Weighted [LwA] Sound Pressure [dBA]
Inlet Sound RPM LwA dBA 3500 +19 +7.5 1770 - -11.5 2900 +13 +1.5 1450 -6 -17.5
Total
Pressure
AX 41-190 6 Blades
Impeller Diameter = 16.25 inches 413 mm
Outlet Velocity Ft/Min = Volume / 1.44
M/S = Volume / 0.13
Tip Speed Ft/Min = RPM X 4.25
M/S = RPM X 1.30
76
72
74
78
74
Air density = 1.2 kg/m Air density = 0.075 lbs/ft
3
76
79
76
78
3
Volume
Peak Absorbed Power [bHP/kw (60 Hz), kw (50 Hz)]
Pitch Angle º
RPM 5 10 15 20 25 30 35 3500 (bHP/kw) 1.09/0.81 1.59/1.18 2.23/1.67 3.00/2.24 3.84/2.87 4.71/3.51 5.58/4.16 1770 (bHP/kw) 0.14/0.11 0.21/0.15 0.29/0.22 0.39/0.29 0.50/0.37 0.61/0.45 0.72/0.54 2900 (kw) 0.46 0.67 0.95 1.27 1.63 2.00 2.37 1450 (kw) 0.06 0.08 0.12 0.16 0.20 0.25 0.30
Sound power level ratings are shown in decibels, referred to 10-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwA sound power levels for 100%, 50% and 0% of peak pressure in Installation Type B: free inlet, ducted outlet. dBA sound pressure values are weighted with 11.5 dB attenuation for each octave band at 5 feet.
Sound Power A-Weighted [LwA] Sound Pressure [dBA]
Inlet Sound RPM LwA dBA 3500 +18 +6.5 1770 - -11.5 2900 +13 +1.5 1450 -6 -17.5
11
Loading...