Greenheck AMD-42 User Manual

AMD-42
Air Measuring Station with
Application and Design
The AMD-42 combines the functionality of an accurate airflow measuring station and an ultra low leakage control damper into one compact assembly that both measures and regulates airflow volumes to a target set-point. The AMD-42 comes standard with a modulating actuator and a properly sized pressure transducer that output a signal proportional to cfm. A field supplied controller can then use the transducer's signal along with the flow formula: CFM = Area * K * (P modulating actuator to the target set-point. K & m are factory supplied variables specific to each damper. The AMD-42 is also available with a factory supplied LON controller that accepts a target flow set-point as an input (either analog or digital) and then positions the damper to achieve that set-point.
Ratings
Velocity: 300 to 2000 fpm (1.5 - 10.2 m/s)
Leakage: 6 cfm/ft 3 cfm/ft2 @ 1 in. wg (55cmh/m2 @ .25 kPa) Temperature: -20°F to 180°F (-29°C to 82ºC) Consult factory for temperature lower than -20°F (-29°C) Monitor Accuracy: 5% of reading
Construction Standard Optional
Frame Material Galvanized Steel -
Frame Material Thickness
Frame Type 5 in. x 1 in. hat channel -
Blade Material Extruded Aluminum -
Blade Type Airfoil -
Blade Action Parallel
Linkage Plated steel out of airstream, concealed in jamb
Axle Bearings Synthetic (acetal)
Axle Material Plated steel 304SS
Blade Seals TPE Silicone
Jamb Seals 304SS -
Sleeve 12 in.
Sleeve Gauge 20 ga. 14 ga. or 16 ga.
Flange None 1 1/2 in. (38mm);
Air Straightener Polycarbonate
Actuator 24VAC 50/60 Hz 24VAC w/ auxiliary
2
@ 4 in. wg (110 cmh/m2 @ 1 kPa)
16 ga. (1.5mm) 12 ga.
14 ga.
Bronze, 304SS
sleeve type
12 in. - 48 in.
(305mm)
Honeycomb
(305mm - 1219mm)
Upstream side,
Downstream side,
Both Sides
-
switches or manual
quadrant
*W & H dimension furnished approximately 1/4 in. (6mm) undersize.
Blade Overlap
Blades overlap to provide added resistance to leakage. When pressure increases, the blade seals are forced together creating a tighter seal.
Features & Control Options
• 24VACmodulatingactuatormountedexternallyor
internally (NEMA 2)
•Factorysupplied0-10VDCpressuretransducer
•OptionalfactorysuppliedLONcontroller(0-10VDC, 2-10VDC,or4-20mA)
VCD-42 Control Damper
transducer
)m to regulate the
W x H
Inches 6 x 6 12 x 8 48 x 74 144 x 74
mm 152 x 152 305 x 203 1219 x 1880 3658 x 1880
* For sizes larger than listed, consult factory.
Minimum Size Maximum Size
External Internal Single Section Multiple Section*
Installation instructions available at www.greenheck.com
AMD-42 Mounting Styles and Specifications