Exhaust Weatherhood Assembly Instructions
Unpack, inspect, and verify receipt of the correct weatherhood pieces for your unit. Some energy recovery units will require two exhaust weatherhoods. The exhaust weatherhood provided with your energy recovery unit is based on the exhaust blower model size.
To determine the weatherhood you have received, measure the exhaust blower scroll (see drawing below) and locate the corresponding “Blower Model” from the table.
Then refer to the Weatherhood Parts List table on the back of this document. Locate the Blower Model and compare the parts listed with the weatherhood you have received.
Once the parts are verified, continue with the weatherhood assembly procedures on Page 2.
Blower Scroll Measurements
A9-9A 9.9 9.5
A10-4A 11.1 4.5
A10-6A 11.1 6
A10-10A 11.1 10.6
A12-8A 13.2 8
A12-12A 13.2 12.6
A15-15A 15.5 15
A18-18A 18.5 18
A20-18A 20.5 18
All dimensions shown in inches
Part Number 462844 • Exhaust Weatherhood
1
Weatherhood Parts List Blower Model
1
6
Exhaust Discharge
Opening
2
4
3
5
7
Part Description Qty
A10-4A A10-6A A9-9A A12-8A A10-10A A12-12A A15-15A A18-18A A20-18A
Part #* Part #* Part #* Part #* Part #* Part #* Part #* Part #* Part #*
Item 1 Weatherhood Right Side 1 712526 712519 711210 711178 712519 711178 711165 711076 711221
Item 2 Damper Assembly 1 - - - - - - - - -
Item 3 Weatherhood Top 1 712525 712518 711209 712544 727644 711177 711164 711074 711217
Item 4 Weatherhood Left Side 1 712527 712520 711213 711179 712520 711179 711166 711075 711220
Item 5 Weatherhood Bottom 1 712528 712521 712542 712541 727646 712540 711231 711230 711232
Item 6 Cutoff 1 712524 712517 711208 712543 727645 711176 711163 711073 711216
Item 7 Birdscreen Assembly 1 852277 852275 852235 852279 852872 852233 852232 852231 852236
NOTE: Some energy recovery units require two exhaust weatherhoods. *Part numbers are for non-painted units. Consult factory for replacement parts on painted units.
Hardware Kit
Part Number 852259
Part Description Qty Part #
Screws, SMS (A) 12 x 5/8 (IHH) 34 415180
Assembly Instructions 1 462844
• Cordless drill (electric or pneumatic)
• 5/16 inch nut setter
Tools Required
Assembly Instructions
The following steps explain how to assemble and attach the exhaust weatherhood to the energy recovery unit. Prepunched holes and sheet metal screws are provided for your convenience.
1. Attach weatherhood sides (Items 1 and 4) to energy recovery unit.
2. Attach bottom (Item 5) and cutoff (Item 6).
3. Attach damper assembly (Item 2). Damper should be sealed against cutoff.
4. Attach top (Item 3) and birdscreen (Item 7).
5. Caulk the unit/weatherhood seams on the top, bottom and sides.
After completing these steps, check to make sure the damper blade (Item 2) seals against the magnetic strips on the weatherhood sides (Items 1 and 4) and along the 45° cutoff plate (Item 5). Adjust as necessary.
Contact your local representative if replacement parts are required.
Part Number 462844 • Exhaust Weatherhood Assembly Instructions, Rev. 6, March 2009 Copyright © 2009