Great things come in small packages, as do our ceiling fan SP models and cabinet fan CSP models. Be
assured when you buy any Greenheck product, you are getting a quality product at a competitive price.
In fact, we guarantee our ceiling and cabinet exhaust fans with a three-year warranty. We offer the most
comprehensive ceiling and cabinet exhaust fan line in the commercial market. We are your market leader!
Benefits
• Lowest sound in the industry
• Compact size
• Five different fan styles offering you a competitive price
• Broadest performance selections in the industry
SP fans are designed for
ceiling mounted applications.
Greenheck Fan Corporation certifies that
the SP models shown herein are licensed
to bear the AMCA seal. The ratings shown
are based on tests and procedures
performed in accordance with AMCA
Publication 211 and AMCA Publication
311 and comply with the requirements of
the AMCA Certified Ratings Program.
The SP models are not AMCA certified
with 50 hertz motors.
CSP fans are designed for inline
remote mounted applications.
Greenheck Fan Corporation certifies
that the CSP models shown herein are
licensed to bear the AMCA seal. The
ratings shown are based on tests and
procedures performed in accordance
with AMCA Publication 211 and
comply with the requirements of the
AMCA Certified Ratings Program.
The CSP models are not AMCA
certified with 50 hertz motors.
Quick Delivery and Quick Build Programs
Order from hundreds of SP and CSP configurations, accessories and thousands
of other products that can ship to your job site in less than 24 hours. We have
strategically located warehouses across the United States and internationally to fill
your request at a moments notice.
For other sizes and configurations where rapid response time is required, our Quick
Build (QB) program manufactures and ships your custom products in one, three,
five, or ten days.
Leading Edge Technical Support
When you need extensive product information look no further. Greenheck
products are supported by the industry’s best product literature, ranging from
catalogs, installation, operation and maintenance manuals (IOM’s), electronic
media, computer aided product selection (CAPS) program and more. You’ll also
find this information on our web site at www.greenheck.com
Models SP and CSP are listed electric fans
(UL/cUL 507). Ceiling Exhaust Fans are also
UL Listed for above bathtub/shower with GFCI
branch protected circuit. File no. E33599.
Count on personal service and expertise from our national and international
representative organizations. To locate your nearest Greenheck representative,
call 715-359-6171 or visit our web site at www.greenheck.com
2
Page 3
Model Comparison
Model and
Performance
Pages
Premium Ceiling
Fan: SP-A
page 16
Deluxe Ceiling
Fan: SP-B
page 17
Economy Ceiling
Fan: SP-C
page 17
Description
In the top of its
class when it comes
to meeting sound
requirements.
Compact enough for
almost any application.
If quiet is what you
are after, this fan will
accommodate your
needs.
Designed for
light commercial
applications.
Profile
(minimum
height)
101⁄2 inches
(267 mm)
615⁄16 inches
(176 mm)
35⁄8 inches
(86 mm)
Sound
(minimum
sones)
0.7
1.4
2.9
Air Volume
(maximum)
1,607 cfm
(2730 m3/hr)
197 cfm
(335 m3/hr)
52 cfm
(88 m3/hr)
UL Listing
UL Listed for above
bathtub/shower
with GFCI branch
protected circuit
(Sizes A390 and
smaller)
UL Listed for above
bathtub/shower
with GFCI branch
protected circuit
UL Listed for above
bathtub/shower
with GFCI branch
protected circuit
Premium Inline
Fan: CSP-A
page 18
Deluxe Inline
Fan: CSP-B
page 19
Outperforms the
competition and is
preferred by specifying
engineers.
Compact and designed
to fit in small remote
quarters.
101⁄2 inches
(267 mm)
615⁄16 inches
(176 mm)
0.8
2.0
3,778 cfm
(6419 m3/hr)
186 cfm
(316 m3/hr)
UL/cUL Listed
UL/cUL Listed
3
Page 4
Standard Construction Features
Model SP-A
10
7
8
6
3
5
4
9
2
1
12
11
9
1
Model SP-B
11
3
12
8
4
1
2
7
10
Model SP-C
2
11
10
3
Model CSP-A
6
10
8
7
3
13
7
5
4
12
9
2
1
12
11
Model CSP-B
7
4
8
12
13
2
1
11
3
10
4
Page 5
Standard Construction Features
#Standard Construction Features
Backdraft
1
Damper
2Outlet
3Power Assembly
4Electrical Access
Electrical
5
Knockouts
Acoustic
6
Insulation
7DisconnectServicing is quick and safe
Electrical
8
Junction Box
Prevents unwanted backdrafts
Spring loaded aluminum to eliminate
rattling and backdrafts
Round - For quick and easy
connections
Square - For quick and easy
connections
Removes quickly for maintenance
Includes conversion from horizontal
to vertical discharge
Vertical electrical access to eliminate
drilling holes
External electrical access to eliminate
removing motor pack, saving
installation time
Eliminates drilling holes
(horizontal or vertical)
Absorbs sound
Large for easy wiring
Specific Features for Each Model
SP-ASP-BSP-CCSP-ACSP-B
Prepunched Prepunched
Prepunched
9Attractive Grille
Mounting
10
Brackets
11 Housing
12 Motors
13 Access Panel
Exclusive
Electrical Wiring
Feature
Double Wide
Fans
Concealed attachment screws
securely fasten grille to housing for
quiet, rattle free operation
Adjustable for multiple installation
conditions
Embossed galvanized steel for rigidity
A low profile for height restricted
areas
All motors are compatible for use
with speed controls and have thermal
overload protection
Domestic & International
• 50 cycle, 220v or 240v
• 60 cycle, 115v, 208v, 220v, 230v, &
277v options
(See CAPS for availability)
Gain easy access to internal
components once installed
Electrical access cover located on the housing exterior. This feature permits external wiring
without removing the power assembly, saving installation time and cost. Available on models
SP-A and CSP-A.
Available for applications requiring 700 cfm or greater.
Double wide fans have two double width forward-curved
wheels, which are housed in separate scrolls, and driven by
a single motor. Available on models SP-A and CSP-A.
60 cycle,
115v only
Vertical
Discharge
Exhaust outlet duct installed in the optional vertical position. The power
assembly must be rotated to match the duct adapter position. Available
on models SP-A and CSP-A.
5
Page 6
Options and Accessories
Ceiling Radiation Damper
The National Fire Protection Association (NFPA)
Standard 90A requires openings in fire rated ceiling/
floor assemblies to be protected by appropriately
rated ceiling radiation dampers. As a result, many
local codes require fans installed in fire rated
ceilings to be protected by dampers which are
insulated against both heat and flame.
UL Classified ceiling radiation dampers are rated at
three to four hours of fire resistance. All model SP-A
fans and fan/light combinations are available with
ceiling radiation dampers. This design saves space
by allowing the damper to mount directly beneath
the fan.
Model SP-A
SP-A Fan
Hanging Vibration
Isolation
Ceiling Radiation
Damper
3 in.
AxB
Grille
Fire
Rated
Ceiling
Contractor 4 Packs
Save installation time and labor by installing
the housing first, then installing the internal
components after the sheetrocking, plastering and
finishing is done. Housings are packaged in one
box, power assemblies and grilles are packaged in
another box. Components are shipped to coincide
with the phase of your project. (Model SP-B only).
Round Duct Connections
• 4 inch - SP models: B50, B70 and B80
• 6 inch - SP models: A50, A70, A90, B90, B110,
B150, and B200
Model SP-B
SP-B Fan
Hanging Vibration
Isolation
Ceiling Radiation
Damper
3 in.
AxB
SP ModelCRDLengthWidthHeight
A50 - A190310
B50 - B200
A200 - A390
A410 - A510
A710 - A780
A700700
A900 - A1550
All dimensions shown in inches (millimeters). Add an “L” to all CRD models if
fan & light combo is used. *CRD is approximately 1/4 inch (6 mm) larger than
housing dimension. (See Installation, Operation and Maintenance Manual)
320
350
36024
13
(343)
14
(365)
18
(468)
24
(614)
(614)
1
⁄2
3
⁄8
7
⁄16
3
⁄16
3
⁄16
Fire Rated
Ceiling
Grille
111⁄8
(283)
121⁄4
(311)
1415⁄16
(379)
121⁄4
(311)
1415⁄16
(379)
6
(76)
(76)
(76)
(76)
(76)
Round Duct Adapter
Optional - SP sizes A110 through A510
Wheel Options
Greenheck’s ceiling and cabinet
fans (models SP and CSP) deliver
high performance from a forward-
curved wheel. The forward-curved
wheel design offers both high-
efficiency and low sound. Fan
wheels are constructed of plastic
3
or steel as standard, and all models
offer an aluminum wheel option.
3
• Level A models utilize steel
3
3
3
or plastic wheel construction
depending on size.
• Level B models are standard with
a plastic wheel.
Plastic
Steel
Aluminum
Page 7
SP Grille and Lighting Options
Grille Options
Designer is the standard grille for
SP models A50-A390 and B50-B200.
Available in white plastic finish, with
or without motion detector or time
delay (see following pages for motion
detector and time delay information).
Decorative grille is optional on
A50-A390 and B50-B200. Available
in white plastic finish, with or without
light, motion detector or time delay
(see following pages for motion
detector and time delay information).
Lighted Grille Options
Greenheck’s fan and light combinations include
either a prismatic or a frosted lens and either
compact fluorescent or incandescent lamps. Our
unique light box is manufactured with a reflective
material to increase the light given off by either type
of lamp. UL Listed for above bathtub and showers
with GFCI branch protected circuit.
Model SP-A, sizes 50 - 390
Model SP-B, sizes 50 - 200
Prismatic Lens
The prismatic lens design provides
approximately 25% more light than
a traditional frosted lens. The lens
may be easily removed to replace
light bulbs.
Frosted Lens
The frosted lens option is a
traditional design which lets
approximately 80% of light through
the lens. The lens may be easily
removed to replace light bulbs.
Incandescent Lamps
One bulb provides up to 100 watts
of light (bulbs to be provided by
others).
• Dimmable
• Reflective light box
Aluminum grille is optional on
A50-A390 and B50-B200. Standard
on A410 and larger. Available in white
enamel finish.
Stainless Steel grille is optional on
A50-A390 and B50-B200. Available in
polished stainless steel finish.
Compact Fluorescent Lamps (CFL)
• Quick start bulbs (1 or 2 bulbs)
• Reective light box
• Produce 90% less heat
• Lower energy costs
• Two 13 watt CFL bulbs equals
100 watts of incandescent light.
Bulbs are included.
A major advantage of using CFL’s is to save money,
as shown in the table below. This table assumes the
light is on for six hours per day and the electric rate
is 10 cents per kilowatt-hour. This study was based
over a 4½ year period.
27 Watt Compact
Fluorescent
Cost of Lamps$14.00$0.50
Lamp Life1,642.5 days (4.5 years)167 days
Annual Energy Cost$5.91$21.90
Lamps Replaced in 4.5
years
Total Cost$40.60$103.55
Savings Over Lamp Life$62.95$0.00
Source: U.S. Department of Energy, August 2001
Office of Energy Efficiency and Renewable Energy
010
100 Watt
Incandescent
7
Page 8
Control Accessories
Speed Controls
Speed controls may be used
on model SP and CSP fans
for manual adjustment of the
fan’s performance (for final
system balancing) or to control
the fan’s output in confined
spaces, such as conference
or meeting rooms. The fan can be
adjusted to 60% of design airflow
with a speed control. This reduction
in airflow and fan speed is also
accompanied by a reduction in
noise level. Solid state speed controls
are available for a range of applications up to 15
amps. Speed controls can be used to operate more
than one fan if the combined total amperage of the
fans do not exceed the control rating.
SWITCHED FULL VOLTAGE
Dotted line indicates
for use with 10W
switch only.
VARIABLE
VOLTAGE
H
FULL VOLTAGE
120 VAC
RED
BLACK
WHITE
SPEED CONTROL
Internal Mounting
AUX
DEVICE
Switches
Switches may be used on model
SP and CSP fans to enable manual
control of your fan or fan and light
combination. There are several
options to fit your application.
NEMA 1 - Single pole rocker switch
assembly.
• Rated for, 115v, 15 Amp, 1/2 hp
• UL Listed
Model MS-16 - Single pole rocker switch assembly
with cover and pilot light.
• Rated for, 115v, 15 Amp, 1/2 hp
• UL Listed
NEMA 1 - Two pole rocker switch assembly.
• Rated for, 220/230/240/277v, 20 Amp, 2 hp
• UL Listed
• Requires a 2x4 handy box.
EXTERNAL JUMPER
FAN
N
LOAD
For use with shaded pole and permanent split
capacitor (PSC) motors. Available shipped loose or
mounted internal or external.
SPEED CONTROL INTERNAL AND/OR EXTERNAL MOUNTING OPTIONS
Model
Voltage Rating
Amp Rating
5WSSC
115 - 127v
5 Amp
10WSSC
115 - 127v
10 Amp
15WSSC
115 - 127v
15 Amp
5W240
220 - 240v
5 Amp
8WSSC
220 - 240v
8 Amp
5W277
227v
5 Amp
NOTES: Speed controllers are not available for 208v applications. SP-C50 Speed Controller is shipped loose only. All speed controller options listed in table are UL Listed.
Handy Box sizes are 2x4 for all options above except 10WSSC and 15WSSC, which are 4x4.
No No No *I/E I/E No I/E I/E *I/E No I/E I/E No I/E No No I/E NoI/ENoI/ENoNoNo
No No No *EENoEE*E NoEENoE No No ENoENoENoNoNo
No No No No I/E I/E I/E I/E *I/E No No No No No No No No No NoNoNoNoNoNo
E = External mounted onlyI/E = Available Internal and External Mounted
KEY:
* Only available on the B-series (A-series is not available)No = Not available
Fan Sizes
8
LOAD
Page 9
Control Accessories
Gnd.
Hot
Black
Green
Red
Load
(12.5 Amps Max.)
Neutral
Black
Red
Black
White
White
Hot
Neutral
Ground
Motion Sensor
Fan Motor and/or
Light
Green
Time Delay Switch
Time delay switches save energy by automatically
turning off equipment. They may be used with SP
and CSP fans or fan and light combinations for
extended operating time of fan. Time delay switches
act in the same manner as a standard switch,
however, there is a delay of 1 to 60 minutes after it
has been turned off.
(500 Watt Max)
BLACKBLUE
(NEUTRAL)
(HOT)
RED
WHITE
115 VOLT AC
60 CYCLE
Model GTD - A single switch controls both fan and
light. Available shipped loose.
• Silent Operation
• Rated for 115v
• UL Listed
• Requires 2x4 handy box
LIGHT
(7.5 Amps Max)
FAN MOTOR
Motion Detectors
Motion detectors may
be used with SP and
CSP fans or fan and light
combinations. Motion
detectors use a passive
infrared motion detector to
automatically turn the
fan on when a change in motion is sensed.
They have a viewing area of 180 degrees,
however they must be placed in the line-
of-sight. They also have an adjustable time
delay shutoff setting of 1 to 20 minutes.
Wall Mount
Grille Motion Detectors are available on models up
through size SP-A390 and SP-B200.
• Rated for 115v
• UL Listed
Grille Mount
Transformers
Transformers are available for
applications requiring voltage
reduction. Selection is based on
motor amperage. All transformers
are shipped loose.
ModelsVoltage RatingsAmp Ratings
T-2.0230/277v to 1152.0 Amps
T-4.3230/277v to 1154.3 Amps
T-6.5230/277v to 1156.5 Amps
T-8.6230/277v to 1158.6 Amps
277 V SUPPLY
BLK
BLK BLK
H1
2H3
H
277V TO 115V TRANS.
750 VA
1X2
X
RED
RED
SWITCH BOX
SWITCH
Model MDW
For use on fan or lights. Available shipped loose.
• Rated for 115v
• UL Listed
• Requires 2x4 handy box
115 V MOTOR
9
Page 10
Filters and Discharge Accessories
RJ-10x10
C
D
E
A
B
Filters
Fans used in most applications will collect airborne
dirt on wheels and motors over time, even where air
is not excessively dirty. Accumulations of dirt on the
fan wheel will sharply reduce performance and cause
imbalance. Dirt buildup on the motor can cause it
to overheat. All of these conditions will shorten the
life of the fan. To help reduce this accumulation,
washable aluminum mesh filters are available to trap
dirt before it enters the fan. These filters should be
regularly cleaned to maintain performance. The Filter
Loss Chart shows the effect the filter will have on
performance. To determine the added resistance,
divide the desired cfm by the filter area (ft2). This will
give FPM. Use this with the filter loss chart to get
the added resistance. Filters reduce sound levels, in
addition to reducing dirt accumulations on the motor
and wheel.
discharge accessories shown on these two pages.
Specific pressure drop values for these accessories
must be included in total system calculations for
proper fan selection.
41⁄4
(108)5 (127)
63⁄4
(171)5 (127)
63⁄4
(171)5 (127)
Model BVE - Brick Vent
• Designed for installation in masonry walls
• Anodized aluminum construction
• Built-in aluminum mesh insect screen
Model
BVE80850-290
BVE128390-510
BVE157700-1050
All dimensions shown in inches
(millimeters).
For use
with all
sizes:
ABC
1
⁄8
8
(206)
12
(305)
5
⁄8
15
(397)
73⁄4
(197)4 (102)
73⁄4
(197)4 (102)
73⁄4
(197)4 (102)
13
Page 14
Things to know when
sound is critical
Sound Data
The sound data shown in this catalog has been presented to aid the system designer in selecting a fan which
will meet the desired sound criteria. Sone levels have been included on the performance pages to provide a
means of quickly evaluating the relative loudness of a fan selection.
What is a sone?
Sones are an internationally recognized unit of loudness. In practical terms, the loudness of one sone is
equivalent to the sound of a quiet refrigerator measured from five feet away in an acoustically average room.
A sone is a single number rating, which indicates the inlet noise derived from the eight audible octave bands.
Sones are a linear measurement of sound level. For example, a sound level of 10 sones is twice as loud as
5 sones.
What is the difference in an AMCA Sone vs. an HVI Sone?
In general, the AMCA (Air Movement and Control Association) sone value is focused on commercial markets,
whereas the HVI (Home Ventilating Institute) sone value is focused on residential markets. Both calculate their
sone data from the same raw test data (eight octave bands), however an AMCA sone applies a hemispherical
correction factor to the sound power and rounds to the nearest 0.1, whereas HVI applies a spherical correction
factor to the sound power and rounds to the nearest 0.1 under 1.5 sones and to the nearest 0.5 for 1.5 sones
and greater. There are no conversions from one sone to the other, each must be calculated. In every instance,
the same fan will have a lower HVI calculated sone rating than an AMCA calculated sone rating.
Can radiated noise increase the sound levels?
Radiated noise from fan housings can cause unacceptable sound levels, on any brand of fan. The size of
these fans allows them to be placed in areas where this noise will be transmitted to the conditioned space
through walls or ceilings. Where possible, cabinet fans should be located in remote parts of the
ventilation system.
When should a SP or CSP fan be used?
Model SP and CSP fans are designed for the lowest possible sound levels. Forward-curved wheels,
insulated housings and vibration isolators between the motor and housing contribute to quiet, efficient
operation. Applied and installed as recommended, SP and CSP sound levels will fall well within the ranges
shown in the Suggested Limits for Room Loudness chart. For applications where sound levels are critical,
a remote mounted CSP with ductboard is recommended. Placement of SP and CSP fans should take into
account the desired sound level at the location of the listener.
Suggested Limits for Room Loudness
SonesDBA
1.3-432-48 Private homes (rural and suburban)
1.7-536-51 Conference rooms
2-638-54 Hotel rooms, libraries, movie theatres, executive offices
2.5-841-58 Schools and classrooms, hospital wards and operating rooms
3-944-60 Court rooms, museums, apartment houses, private homes (urban)
4-248-64 Restaurants, lobbies, general open offices, banks
5-1551-67 Corridors and halls, cocktail lounges, washrooms and toilets
7-2156-72 Hotel kitchens and laundries, supermarkets
Reprinted from AMCA Publication 302 (Application of Sone Ratings for Non-ducted Air Moving
Devices, with room—sone—dBA correlations) with the written permission from the AMCA
International, Inc., 30 West University Drive, Arlington Heights, IL 60004-1893.
NOTE: Values above are for room loudness and are not sound ratings. Room loudness is the resulting
level in a conditioned space after the acoustical qualities of the room have been accounted for.
14
Page 15
Things to know when
sound is critical
Their compact size allows the system designer greater flexibility in locating these fans for lowest sound
levels. In critical sound areas, insulated ductwork, flexible duct connections, or placing the fan in a remote
section of the ductwork (away from the critical area) offers the best means of meeting desired sound levels.
When room sound levels are critical, such
as in executive offices, conference rooms,
hospital operating rooms, and school study
areas, a CSP fan is the best choice. Shown
here is a comparison of SP and CSP fans
of the same size, with equal performance in
typical installations. The CSP shows lower
sone values.
ModelCFMWGFRPM Sones
SP-A4104051/810003.7
CSP-A4104261/810002.1
*Sone value with insulated inlet duct.
Fiberglass
Model SP mounted directly
overhead may be too
loud for sound critical
applications.
Remote mounted
model CSP with
vibration isolators
and insulated
ductwork provides
the quietest
installation.
Model Number Code
SP - A 50 FL
Light Options:
L - Fan/Light (Incandescent) Combination
FL - Fan/Light (Fluorescent) Combination
Nominal cfm at 0.10 inches static pressure
Level of Construction:
A - Premium unit; lowest sound, insulated housing
B - Deluxe unit; low sound, low profile
C - Standard unit; lowest profile, inexpensive
Model:
SP - Silent Partner
CSP - Cabinet Silent Partner
15
Page 16
Model SP-A
A
B
C
D
E
Premium Ceiling Fan
Model SP-A Dimensions
ModelABCDE
1
⁄4
105⁄8
(270)
105⁄8
(270)
117⁄8
(302)
143⁄8
(365)
115⁄8
(295)
143⁄8
(365)
143⁄8
(365)
115⁄8
(295)6 (152)
101⁄2
(267)8 (203)6 (152)
111⁄4
(286)8 (203)8 (203)
141⁄2
(368)8 (203)8 (203)
115⁄8
191⁄2
(295)
(495)8 (203)
141⁄2
10
(368)
(254)8 (203)
141⁄2
183⁄4
(368)
(476)8 (203)
50, 70, 90
110, 125, 190
200, 250, 290,
390
410, 510
700
710, 780
900, 1050,
1410, 1550
All dimensions are in inches (millimeters) and weight in pounds (kilograms).
Outlet connection width is 1 in. (25 mm) - Mounting bracket width is 1½ in. (38 mm).
For complete dimensional information, see CAPS submittal drawings.
13
(337)
13
(337)
14
(356)
18
(457)
23
(600)
18
(457)
23
(603)
1
⁄4
5
⁄8
3
⁄4
Designer
Grille
147⁄8 x 131⁄4
(378 x 337)
193⁄8 x 163⁄8
(492 x 416)
251⁄8 x 131⁄2
(638 x 343)
193⁄8 x 163⁄8
(492 x 416)
25 x 163⁄8
(635 x 416)
Decorative
151⁄4(387) sq.
Grille
—
Unit
Weight
12
(5)
17
(8)
24
(11)
31
(14)
34
(15)
34
(15)
56
(25)
B
A
E
C
D
A
B
E
C
D
ModelRPMAmpsWatts
SP-A50
2, 3, 5
SP-A70
2, 3, 5
SP-A90
2, 3, 5
SP-A110
SP-A125
SP-A190
SP-A200
SP-A250
SP-A290
SP-A390
SP-A410
SP-A510
SP-A700
SP-A710
SP-A780
SP-A900
SP-A1050
SP-A1410
SP-A1550
2, 3, 4, 5, 6
2, 3, 5, 6
3, 4, 5, 6
3, 5
3, 5
3, 4, 5
3, 4, 5
3
3, 4
3
3
3, 4
3
3, 4
3
3, 4
7000.3118.3
8500.2720.2
9000.3429.4
9500.5848.7
11000.6252.5
14001.30113
9000.4348.2
10000.7783.1
10500.7280.7
13501.34135
10001.74121
10703.30224
11003.20350
10804.40285
16003.30348
9504.00285
10956.30420
14507.40786
16108.60818
CFM76514831
Sones0.50.70.81.3
CFM83706742
Sones0.80.80.81.6
CFM9988846125
Sones0.81.00.91.21.4
CFM11911010688
Sones0.80.80.11.1
CFM135123121104
Sones0.91.21.31.3
CFM216197192167133
Sones2.52.52.52.52.5
CFM24722522019617214210567
Sones1.42.02.02.53.03.53.54.0
CFM272251246227210185157119
Sones2.52.52.52.53.54.04.04.0
CFM315293287257231207175124
Sones2.52.52.53.03.03.53.54.5
CFM410395391368345325307279
Sones4.54.54.54.55.05.05.55.5
CFM443413405351306
Sones3.53.03.03.03.5
CFM557512501439392325
Sones5.04.54.54.54.54.0
CFM757723723700679649613560494396
Sones5.05.05.05.55.56.06.06.56.56.5
CFM752714701653588486320
Sones6.06.06.06.06.05.55.5
CFM812782775741704665625581
Sones8.58.58.58.08.08.08.08.0
CFM955907896841773701
Sones4.05.05.05.05.05.0
CFM112510591043964885796662
Sones6.06.06.06.05.55.55.5
CFM14551415140413531307126212181174
Sones10.010.010.010.010.010.010.010.0
CFM16071558155815061449140713691323
Sones10.510.010.010.010.010.511.513.0
00.10.1250.250.3750.50.6250.750.8751
2 Available with light
3 Available with CRD - Ceiling Radiation Damper
4 Also available with 50 Hz motors
Performance certified is for model SP exhaust for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft
damper. Speed (rpm) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in spherical fan sones at 5 ft (1.5m)
in a spherical free field calculated per Annex B of AMCA 311. Values shown are for installation type B: free inlet spherical fan sone levels.
(See page 20 for performance)
CFM / Static Pressure in Inches wg
5 UL Listed for use above tubs.
6 Available with 277 volt motor.
16
Page 17
Model SP-B and SP-C
A
B
C
D
E
A
B
C
D
E
B
C
F
E
D
A
A
B
C
D
E
Deluxe and Standard Ceiling Fan
Model SP-B Dimensions
3/4
(19) 14
11⁄4
(32)
Designer
Grille
7
⁄8 x 131⁄4
(378 x 337)
ModelABC*DE
7
⁄8
111⁄2
(292)
111⁄2
(292)
615⁄16
(176)4 (102)
715⁄16
(202)6 (152)
50, 70 & 80
90, 110, 150,
200
All dimensions are in inches (millimeters) and weight in pounds (kilograms). *Add 1½ in. (38 mm) to C
dimension for incandescent light. Mounting bracket width is 1½ in. (38 mm). For complete dimensional
information, see CAPS submittal drawings.
13
(352)
13
(352)
7
⁄8
Decorative
Grille
151⁄4(387) sq.
Unit
Weight
9
(4)
10
(5)
B
A
D
E
C
ModelRPMAmpsWatts
SP-B50
2, 3, 5
SP-B70
2, 3, 5
SP-B80
2, 3, 5
SP-B90
2, 3, 4, 5
SP-B110
SP-B150
SP-B200
2 Available with light
3 Available with CRD - Ceiling Radiation Damper
4 Also available with 50 Hz motors (See page 20 for performance)
Performance certified is for model SP exhaust for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft
damper. Speed (rpm) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in spherical fan sones at 5 ft (1.5m)
in a spherical free field calculated per Annex B of AMCA 311. Values shown are for installation type B: free inlet spherical fan sone levels.
2, 3, 4, 5, 6
2, 3, 4, 5, 6
3, 4, 5, 6
6250.5037.8
6750.5345.1
9000.6054.3
7000.6549.7
9501.1480.2
10501.70128
11002.20172
CFM6754514029
Sones1.21.41.42.03.0
CFM777168574939
Sones1.21.41.42.02.53.0
CFM8780786861544430
Sones2.02.02.52.53.03.54.54.5
CFM101898875594530
Sones1.52.02.02.53.03.54.0
CFM13311411097959491857250
Sones1.51.51.52.02.02.03.03.54.04.5
CFM16015615515415214914713812392
Sones2.52.52.53.03.53.54.04.54.55.0
CFM197195194191187184181166151128
Sones3.54.04.04.54.55.05.05.55.55.5
00.10.1250.250.3750.50.6250.750.8751
ModelABCDEF
50
All dimensions are in inches (millimeters) and weight in pounds (kilograms). For
complete dimensional information, see CAPS submittal drawings.
Model SP-C Dimensions
1
⁄2
71⁄2
7
(191)
(191)
35⁄8
(92)3 (76)
15⁄8
(41)
Decorative
1/2
91⁄4 x 9
(13)
(235 x 229)5 (2)
Grille
Unit
Weight
CFM / Static Pressure in Inches wg
5 UL Listed for use above tubs.
6 Available with 277 volt motor.
B
E
C
A
D
F
ModelRPMAmpsWatts
SP-C5016800.8046
Performance certified is for model SP exhaust for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of
an inlet grille and backdraft damper. Speed (rpm) shown is nominal. Performance is based on actual speed of test. The sound ratings shown
are loudness values in spherical fan sones at 5 ft (1.5m) in a spherical free field calculated per Annex B of AMCA 311. Values shown are for
installation type B: free inlet spherical fan sone levels.
CFM52494947443829
Sones3.03.03.03.03.54.04.0
CFM / Static Pressure in Inches wg
00.10.1250.250.3750.50.625
17
Page 18
Model CSP-A
A
B
C
D
E
F
Inlet
G
Premium Inline Fan
Model CSP-A Dimensions
91⁄4
(235)
10
(254)
131⁄4
(337)
101⁄2
(267)
131⁄4
(337)
131⁄4
(337)
13
(330)
145⁄8
(371)
Unit
Weight
16
(7)
23
(10)
36
(16)
34
(15)
36
(16)
59
(27)
68
(31)
122
(55)
ModelABCDEFG
1
⁄4
105⁄8
110, 125, 190
200, 250, 290,
390
410, 510
700
710, 780
900, 1050,
1410, 1550
1750, 2150
3600
All dimensions are in inches (millimeters) and weight in pounds (kilograms). Inlet and outlet
connection widths are 1 in. (25 mm) - Mounting bracket width is 1½ in. (38 mm). For
complete dimensional information, see CAPS submittal drawings.
13
(337)
14
(356)
18
(457)
5
23
(600)
18
(457)
3
23
(603)
35
(889)
1
45
(1156)
⁄8
⁄4
⁄2
101⁄2
(270)
(267)8 (203)6 (152)
117⁄8
111⁄4
(302)
(286)8 (203)8 (203)
143⁄8
141⁄2
(365)
(368)8 (203)8 (203)
115⁄8
115⁄8
(295)
(295)
143⁄8
141⁄2
(365)
(368)
143⁄8
141⁄2
(365)
(368)
143⁄4
143⁄4
(375)
(375)
161⁄2
161⁄2
(419)
(419)
191⁄2
(495)8 (203)
10
(254)8 (203)
183⁄4
(476)8 (203)
28
(711)6 (152)
40
(1016)
(279)
11
12
(305)
127⁄8
(327)
167⁄8
(429)
225⁄8
(575)
167⁄8
(429)
225⁄8
(575)
323⁄4
(832)
431⁄4
(1099)
F
G
E
B
C
D
A
B
A
E
G
D
C
F
Inlet
ModelRPMAmpsWatts
CSP-A1109500.6248.7
CSP-A125
CSP-A190
11000.6352.5
6
14001.10100.0
4, 6
CSP-A2009000.4348.2
CSP-A25010000.7982.7
CSP-A290
10500.7180.7
4
CSP-A39013501.33140.0
CSP-A41010001.87135.0
CSP-A51010703.11217.0
CSP-A70011003.20350.0
CSP-A71010804.40325.0
CSP-A780
16003.77405.0
4
CSP-A9009504.87328.0
CSP-A1050
10956.65455.0
4
CSP-A141014507.80822.0
CSP-A1550
16108.32830.0
4
CSP-A175011306.60550.0
CSP-A215011007.80735.0
CSP-A360011007.101330.0
CFM12411211010277
Sones0.80.70.891.00.9
CFM13812612411491
Sones1.11.11.11.01.2
CFM215202198180159121
Sones2.01.52.02.02.52.5
CFM25423122620317814510970
Sones0.60.40.50.91.01.31.51.5
CFM266246241221205187165132
Sones0.91.01.02.02.53.02.52.5
CFM318299292265248229201144
Sones1.11.21.32.02.53.53.03.0
CFM412400397382363339324309
Sones2.02.02.02.53.04.04.54.5
CFM447441403364317217
Sones1.51.51.52.02.02.0
CFM545514506464405324
Sones2.52.02.02.02.02.5
CFM766755752739726702678635549418
Sones2.02.02.02.02.02.02.02.52.54.0
CFM737698688635567475334
Sones2.52.52.52.52.02.02.0
CFM813784777742707672638603567527
Sones3.03.03.03.03.02.03.03.0
CFM908852841782715631
Sones1.41.41.42.02.03.0
CFM1182111010931013922832743
Sones2.52.52.52.52.52.52.5
CFM1584154315331483143913951345129312381181
Sones3.53.53.53.53.53.53.53.54.04.0
CFM1672161816041543148414271367130712401172
Sones5.04.54.54.54.54.04.04.54.54.5
CFM1842176817491619146412841032772484
Sones5.05.05.04.54.04.03.53.03.0
CFM22492175215620441900170114241114
Sones5.04.54.54.04.04.03.03.0
CFM3778365336223460328030912844255122321750
Sones5.05.05.06.54.54.04.04.03.53.5
4 Units also available with 50 Hz motors (See page 21 for performance) 6 Available with 277 volt motor.
Performance certified is for model CSP inline for installation type D: Ducted inlet, Ducted outlet. Performance ratings include the effects of a backdraft damper. Speed
(rpm) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in spherical fan sones at 5 ft (1.5m) in a spherical
free field calculated per Annex B of AMCA 311. Values shown are for installation type D: ducted inlet spherical fan sone levels. Ratings do not include the effect of duct
end correction. Ratings are based on 10 ft of insulated duct. The AMCA Certified Ratings Seal applies to air performance ratings only.
00.10.1250.250.3750.50.6250.750.8751
CFM / Static Pressure in Inches wg
18
Page 19
Model CSP-B
A
E
D
C
B
F
G
A
B
C
D
E
F
Inlet
G
Deluxe Inline Fan
Model CSP-B Dimensions
ModelABCDEFG
7
⁄8
111⁄2
(292)
715⁄16
(202)6 (152)
110, 150, 200
All dimensions are in inches (millimeters) and weight in pounds (kilograms).
Outlet connection width is 1 in. (25 mm) - Mounting bracket width is 1½ in. (38 mm).
For complete dimensional information, see CAPS submittal drawings.
ModelRPMAmpsWatts
CSP-B110
CSP-B150
CSP-B200
4 Units also available with 50 Hz motors
(See page 21 for performance)
Performance certified is for model CSP inline for installation type D: Ducted inlet, Ducted outlet. Performance ratings include the effects of a backdraft
damper. Speed (rpm) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in spherical fan
sones at 5 ft (1.5m) in a spherical free field calculated per Annex B of AMCA 311. Values shown are for installation type D: ducted inlet spherical fan sone
levels. Ratings do not include the effect of duct end correction. Ratings are based on 10 ft of insulated duct. The AMCA Certified Ratings Seal applies to
air performance ratings only.
13
(352)
9501.1480
4, 6
10501.70129
4, 6
11002.20173
4, 6
11⁄4
101⁄4
(32)
31⁄4(83)
(260)
CFM1031001009897969486
Sones1.51.52.02.02.02.02.52.5
CFM151150149148144146142135
Sones2.02.02.02.02.52.53.03.0
CFM186184189182181179175170
Sones3.03.03.03.03.53.53.53.5
6 Available with 277 volt motor.
Unit
Weight
101⁄4
(5)
Inlet
FxG
E
B
CFM / Static Pressure in Inches wg
00.10.1250.250.3750.50.6250.75
A
D - diameter
C
19
Page 20
Model SP
A
B
C
D
E
A
B
C
D
E
A
B
C
D
E
B
C
F
E
D
A
50 Cycle Performance
For uses in countries with 50 cycle (50 Hz) power,
Greenheck offers the same reliability and performance
for ceiling mounted exhaust fans model SP.
• Same dimensions and outlet options
• Performance shown in 50 cycle RPMs
• Full line of grille and discharge accessories available
Model SP Dimensions
SP-AABCDE
1
⁄4
105⁄8
(270)
105⁄8
(270)
117⁄8
(302)
143⁄8
(365)
143⁄8
(365)
143⁄8
(365)
111⁄2
(292)
111⁄2
(292)
115⁄8
(295)6 (152)
101⁄2
(267)8 (203)6 (152)
111⁄4
(286)8 (203)8 (203)
141⁄2
(368)8 (203)8 (203)
141⁄2
10
(368)
(254)8 (203)
141⁄2
183⁄4
(368)
(476)8 (203)
615⁄16
(176)4 (102)
715⁄16
(202)6 (152)
50, 70, 90
110, 125, 190
200, 250, 290,
390
410, 510
710, 780
900, 1050,
1410, 1550
Outlet connection width is 1 in. (25 mm) - Mounting bracket width is 1½ in. (38 mm).
SP-BABCDE
50, 70 & 80
90, 110, 150,
200
All dimensions are in inches (millimeters) and weight in pounds (kilograms). *Add 1½ in. (38 mm) to C
dimension for incandescent light. Mounting bracket width is 1½ in. (38 mm). For complete dimensional
information, see CAPS submittal drawings.
13
(337)
1
13
(337)
14
(356)
18
(457)
18
(457)
233⁄4
(603)
7
13
(352)
137⁄8
(352)
⁄4
⁄8
Standard
147⁄8 x 131⁄4
(378 x 337)
193⁄8 x 163⁄8
(492 x 416)
193⁄8 x 163⁄8
(492 x 416)
25 x 163⁄8
(635 x 416)
Designer
3/4
147⁄8 x 131⁄4
(19)
(378 x 337)15
11⁄4
147⁄8 x 131⁄4
(32)
(378 x 337)
Grille
Grille
Decorative
Grille
151⁄4(387)
square
—
Decorative
Grille
1
⁄4(387)
square
Unit
Weight
12
(5)
17
(8)
24
(11)
31
(14)
34
(15)
56
(25)
Unit
Weight
9
(4)
10
(5)
SP-A
B
C
A
E
D
SP-A (double wide)
A
B
E
C
D
SP-B
B
C
A
D
E
ModelRPMAmpsWatts
SP-A110
(50 Hertz Motor)
SP-A190
(50 Hertz Motor)
SP-A290
(50 Hertz Motor)
SP-A390
(50 Hertz Motor)
SP-A510
(50 Hertz Motor)
SP-A780
(50 Hertz Motor)
SP-A1050
(50 Hertz Motor)
SP-A1550
(50 Hertz Motor)
SP-B90
(50 Hertz Motor)
SP-B110
(50 Hertz Motor)
SP-B150
(50 Hertz Motor)
SP-B200
(50 Hertz Motor)
Model SP with 50 hertz motor is not AMCA certified.
9500.2949
14000.65113
10500.3681
13500.67135
9001.65224
13341.65348
9503.15420
13404.3818
7000.32550
9500.5780
10500.85129
11001.1173
CFM11911511010610388
Sones1.31.31.21.21.31.6
CFM216206197192187167133
Sones3.23.02.82.92.93.13.4
CFM329315302296290262222164
Sones3.23.33.33.33.43.74.04.9
CFM410402395392387368345325
Sones5.45.45.45.45.55.76.06.3
CFM447425400388376315159
Sones3.73.53.33.33.33.12.6
CFM677659642633625591544493
Sones8.88.98.88.78.68.28.18.1
CFM990945905886867769531
Sones7.27.06.86.86.86.66.5
CFM13371314129012791266121111611112
Sones11.110.710.610.610.610.511.613.5
CFM10297928886755945
Sones1.92.22.62.72.73.03.64.1
CFM133124114110107979594
Sones2.02.02.12.22.22.42.72.8
CFM160158156155155154152149
Sones3.03.13.33.33.43.74.34.5
CFM197196195194194191187184
Sones4.44.74.64.74.95.15.65.8
0.0000.0500.1000.1250.1500.2500.3750.500
CFM / Static Pressure in Inches of wg.
20
Page 21
Model CSP
A
B
C
D
E
F
Inlet
G
A
E
D
C
B
F
G
A
B
C
D
E
F
Inlet
G
50 Cycle Performance
For uses in countries with 50 cycle (50 Hz) power,
Greenheck offers the same reliability and performance
for inline cabinet fans model CSP.
• Same dimensions and outlet options
• Performance shown in 50 cycle RPMs
• Full line of discharge accessories available
Model CSP Dimensions
91⁄4
(235)
10
(254)
131⁄4
(337)
101⁄2
(267)
131⁄4
(337)
131⁄4
(337)
13
(330)
145⁄8
(371)
31⁄4
(83)
Unit
Weight
16
(7)
23
(10)
36
(16)
34
(15)
36
(16)
59
(27)
68
(31)
122
(55)
Unit
Weight
101⁄4
(5)
CSP-AABCDEFG
1
⁄4
105⁄8
110, 125, 190
200, 250, 290,
390
410, 510
700
710, 780
900, 1050,
1410, 1550
1750, 2150
3600
CSP-BABCDEFG
110, 150, 200
All dimensions are in inches (millimeters) and weight in pounds (kilograms). Inlet and outlet
connection widths are 1 in. (25 mm) - Mounting bracket width is 1½ in. (38 mm). For
complete dimensional information, see CAPS submittal drawings.
13
(337)
14
(356)
18
(457)
5
23
(600)
18
(457)
233⁄4
(603)
35
(889)
1
45
(1156)
7
13
(352)
⁄8
⁄2
⁄8
101⁄2
(270)
(267)8 (203)6 (152)
117⁄8
111⁄4
(302)
(286)8 (203)8 (203)
143⁄8
141⁄2
(365)
(368)8 (203)8 (203)
115⁄8
115⁄8
(295)
(295)
143⁄8
141⁄2
(365)
(368)
143⁄8
141⁄2
(365)
(368)
143⁄4
143⁄4
(375)
(375)
161⁄2
161⁄2
(419)
(419)
111⁄2
715⁄16
(292)
(202)6 (152)
191⁄2
(495)8 (203)
10
(254)8 (203)
183⁄4
(476)8 (203)
28
(711)6 (152)
40
(1016)
(279)
11
11⁄4
(32)
12
(305)
127⁄8
(327)
167⁄8
(429)
225⁄8
(575)
167⁄8
(429)
225⁄8
(575)
323⁄4
(832)
431⁄4
(1099)
101⁄4
(260)
CSP-A
F
G
E
B
C
D
A
CSP-A (double wide)
B
G
F
Inlet
A
E
D
C
CSP-B
D - diameter
Inlet
FxG
E
B
A
C
ModelRPMAmpsWatts
CSP-A110
(50 Hertz Motor)
CSP-A190
(50 Hertz Motor)
CSP-A390
(50 Hertz Motor)
CSP-A780
(50 Hertz Motor)
CSP-A1050
(50 Hertz Motor)
CSP-A1550
(50 Hertz Motor)
CSP-B110
(50 Hertz Motor)
CSP-B150
(50 Hertz Motor)
CSP-B200
(50 Hertz Motor)
Model CSP with 50 hertz motor is not AMCA certified.
9500.3151
14000.55100
13500.665144
13341.885405
9503.325455
13404.16830
9500.5780
10500.85129
11001.1173
CFM12411611211010910277
Sones1.11.11.11.11.11.31.3
CFM215202198180159121
Sones2.32.02.22.72.93.0
CFM412400397382363339324309
Sones2.82.72.83.23.74.75.56.5
CFM685656648609562520481
Sones5.04.94.84.74.64.74.9
CFM10791031982957934841655
Sones6.36.36.05.95.96.05.5
CFM1391132613111240117110981019929
Sones7.57.47.47.37.47.37.37.2
CFM103102100999998979693
Sones2.01.92.02.12.12.32.62.73.1
CFM151150149149149148148145142
Sones2.52.72.72.72.72.93.13.43.6
CFM186185184183183182180178175
Sones3.43.73.63.73.74.04.14.14.3
0.0000.0500.1000.1250.1500.2500.3750.5000.625
CFM / Static Pressure in Inches of wg
21
Page 22
Model SP Specifications
Models SP-A50 thru A1550
Ceiling mounted exhaust fans shall be of the centrifugal direct drive type. The fan housing shall be constructed
of heavy-gauge galvanized steel. The housing interior shall be lined with 1/2 inch (13 mm) acoustical insulation.
The outlet duct collar shall include an aluminum backdraft damper on all SP-A sizes and shall be spring loaded
on size SP-A110 and larger. Outlet shall be adaptable for horizontal or vertical discharge. The designer grille for
sizes SP-A50 through SP-A390 shall be constructed of high-impact polystyrene and for sizes SP-A410 through
SP-A1550, the grille shall be constructed of aluminum. Grilles shall be non-yellowing.
The access for wiring shall be external. The motor disconnect shall be internal and of the plug-in type. The
motor shall be mounted on vibration isolators. The fan wheel shall be of the forward-curved centrifugal
type and dynamically balanced. All fans shall bear the AMCA Certified Ratings program AMCA Sound
and Air Performance seal and shall be UL/cUL Listed. Ceiling or wall mount fans shall be model SP as
manufactured by Greenheck Fan Corporation, Schofield, Wisconsin.
*Model SP-A fans with 50 hertz motors are not AMCA certified.
Models SP-B50, B70, B80, B90, B110, B150, and B200
Ceiling mounted exhaust fans shall be of the centrifugal direct drive type. The fan housing shall be
constructed of galvanized steel. The steel duct collar shall be 4 inch (102 mm) in diameter on the B50, B70,
and B80 and 6 inch (152 mm) in diameter on the B90, B150, and B200 to accept 4 inch (102 mm) and 6 inch
(152 mm) round ductwork and shall include a backdraft damper. The designer grille shall be constructed of
non-yellowing high impact polystyrene and attached to the housing with hidden attachment screws. The
access for wiring shall be external. The motor disconnect shall be internal and of the plug–in type.
The motor shall be mounted on vibration isolators. The fan wheel shall be of the forward curved centrifugal
type, constructed of calcium carbonate filled polypropylene and dynamically balanced. All fans shall bear
the AMCA Certified Ratings program AMCA Sound and Air Performance seal and shall be UL/cUL Listed.
Ceiling or wall mount fans shall be model SP-B50, B70, B80, B90, B110, B150 or B200 as manufactured by
Greenheck Fan Corporation, Schofield, Wisconsin.
*Model SP-B fans with 50 hertz motors are not AMCA certified.
Model SP-C50
Ceiling mounted exhaust fans shall be of the centrifugal direct drive type. The fan housing shall be
constructed of galvanized steel. The plastic duct collar shall be a sleeve for ease of connection to
3 inch (76 mm) and 4 inch (102 mm) round ductwork and shall include a backdraft damper. The grille shall be
constructed of non-yellowing high impact polystyrene and attached to the housing with torsion springs.
The wheels shall be constructed of high-strength polymer. The access for wiring shall be easily accessible
internally. The motor disconnect shall be internal and of the plug-in type. All fans shall bear the AMCA
Certified Ratings program AMCA Air Performance seal. Model SP-C50 shall be UL Listed. Fans shall be
model SP-C50 as supplied by Greenheck Fan Corporation, Schofield, Wisconsin.
*Model SP-C fans with 50 hertz motors are not AMCA certified.
22
Page 23
Model CSP Specifications
Models CSP-A110 thru A3600
Duct mounted exhaust, supply or return air fans shall be of the centrifugal direct drive type. The fan housing
shall be constructed of heavy-gauge galvanized steel. The housing interior shall be lined with 1/2 inch (13
mm) acoustical insulation. The outlet duct collar shall include an aluminum backdraft damper and shall be
adaptable for horizontal or vertical discharge. The access for wiring shall be external. The motor disconnect
shall be internal and of the plug-in type.
The motor shall be mounted on vibration isolators. The fan wheel shall be of the forward-curved
centrifugal type and dynamically balanced. All fans shall bear the AMCA Certified Ratings program AMCA
Air Performance seal and shall be UL/cUL Listed. Ceiling or wall mount fans shall be model CSP as
manufactured by Greenheck Fan Corporation, Schofield, Wisconsin.
*Model CSP-A fans with 50 hertz motors are not AMCA certified.
Models CSP-B110, B150 and B200
Duct mounted exhaust, supply or return air fans shall be of the centrifugal direct drive type. The fan housing
shall be constructed of galvanized steel. The steel duct collar shall be 6 inch (152 mm) in diameter to accept
6 inch (152 mm) round ductwork and shall include a backdraft damper. The access for wiring shall be
external. The motor disconnect shall be internal and of the plug-in type.
The motor shall mounted on vibration isolators. The fan wheel shall be of the forward-curved centrifugal
type, constructed of calcium carbonate filled polypropylene and dynamically balanced. All fans shall bear
the AMCA Certified Ratings program AMCA Air Performance seal and shall be UL/cUL Listed. Ceiling or
wall mount fans shall be model CSP-B110, B150 or B200 as manufactured by Greenheck Fan Corporation,
Schofield, Wisconsin.
*Model CSP-B fans with 50 hertz motors are not AMCA certified.
23
Page 24
Ceiling Fan Solutions
Ceiling Fans
SP-A110
SP-A50
Ceiling Fans
w/ Light
SP-A110
SP-A70
Ceiling Fans
w/ CRD
SP-A390
SP-A90
Ceiling Fans
w/ Light & CRD
SP-A125
SP-A90
SP-B50
SP-B90
SP-B200
SP-B80
Our Warranty
Greenheck Fan Corporation warrants its SP/CSP products to be free of any defect
in material or workmanship for a period of three years from the date of shipment.
In the event of such a defect during the warranty period, Greenheck Fan Corporation
agrees, at its option, to either repair or replace the defective product free of charge.
This warranty runs to the original purchaser of such SP/CSP products for a period
of three years from the date of shipment. Any product repaired or replaced under
this warranty will, itself, be warranted only for the remainder of the warranty period
of the original product being repaired or replaced. All light bulbs are excluded under
this limited warranty. Greenheck Fan Corporation is not responsible for any removal,
installation, or transportation cost.
As a result of our commitment to continuous improvement, Greenheck reserves the right
to change specifications without notice.