Greenheck 10WSSC User Manual

Page 1
Centrifugal Ceiling and Cabinet Exhaust Fans
Models SP and CSP
January
2010
Page 2
Ceiling and Cabinet Exhaust Fans
Great things come in small packages, as do our ceiling fan SP models and cabinet fan CSP models. Be assured when you buy any Greenheck product, you are getting a quality product at a competitive price. In fact, we guarantee our ceiling and cabinet exhaust fans with a three-year warranty. We offer the most comprehensive ceiling and cabinet exhaust fan line in the commercial market. We are your market leader!
Benefits
• Lowest sound in the industry
• Compact size
• Five different fan styles offering you a competitive price
• Broadest performance selections in the industry
SP fans are designed for
ceiling mounted applications.
Greenheck Fan Corporation certifies that
the SP models shown herein are licensed
to bear the AMCA seal. The ratings shown
are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
The SP models are not AMCA certified with 50 hertz motors.
CSP fans are designed for inline
remote mounted applications.
Greenheck Fan Corporation certifies
that the CSP models shown herein are
licensed to bear the AMCA seal. The
ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
The CSP models are not AMCA certified with 50 hertz motors.
Quick Delivery and Quick Build Programs
Order from hundreds of SP and CSP configurations, accessories and thousands of other products that can ship to your job site in less than 24 hours. We have strategically located warehouses across the United States and internationally to fill your request at a moments notice.
For other sizes and configurations where rapid response time is required, our Quick Build (QB) program manufactures and ships your custom products in one, three,
five, or ten days.
Leading Edge Technical Support
When you need extensive product information look no further. Greenheck products are supported by the industry’s best product literature, ranging from catalogs, installation, operation and maintenance manuals (IOM’s), electronic media, computer aided product selection (CAPS) program and more. You’ll also find this information on our web site at www.greenheck.com
Models SP and CSP are listed electric fans
(UL/cUL 507). Ceiling Exhaust Fans are also UL Listed for above bathtub/shower with GFCI branch protected circuit. File no. E33599.
Count on personal service and expertise from our national and international
representative organizations. To locate your nearest Greenheck representative,
call 715-359-6171 or visit our web site at www.greenheck.com
2
Page 3
Model Comparison
Model and
Performance
Pages
Premium Ceiling
Fan: SP-A
page 16
Deluxe Ceiling
Fan: SP-B
page 17
Economy Ceiling Fan: SP-C
page 17
Description
In the top of its class when it comes to meeting sound requirements.
Compact enough for almost any application. If quiet is what you are after, this fan will accommodate your needs.
Designed for light commercial applications.
Profile
(minimum
height)
101⁄2 inches
(267 mm)
615⁄16 inches
(176 mm)
35⁄8 inches
(86 mm)
Sound
(minimum
sones)
0.7
1.4
2.9
Air Volume
(maximum)
1,607 cfm
(2730 m3/hr)
197 cfm
(335 m3/hr)
52 cfm
(88 m3/hr)
UL Listing
UL Listed for above bathtub/shower with GFCI branch
protected circuit
(Sizes A390 and
smaller)
UL Listed for above bathtub/shower with GFCI branch
protected circuit
UL Listed for above bathtub/shower with GFCI branch
protected circuit
Premium Inline
Fan: CSP-A
page 18
Deluxe Inline
Fan: CSP-B
page 19
Outperforms the competition and is preferred by specifying engineers.
Compact and designed to fit in small remote quarters.
101⁄2 inches
(267 mm)
615⁄16 inches
(176 mm)
0.8
2.0
3,778 cfm
(6419 m3/hr)
186 cfm
(316 m3/hr)
UL/cUL Listed
UL/cUL Listed
3
Page 4
Standard Construction Features
Model SP-A
10
7
8
6
3
5
4
9
2
1
12
11
9
1
Model SP-B
11
3
12
8
4
1
2
7
10
Model SP-C
2
11
10
3
Model CSP-A
6
10
8
7
3
13
7
5
4
12
9
2
1
12
11
Model CSP-B
7
4
8
12
13
2
1
11
3
10
4
Page 5
Standard Construction Features
# Standard Construction Features
Backdraft
1
Damper
2 Outlet
3 Power Assembly
4 Electrical Access
Electrical
5
Knockouts
Acoustic
6
Insulation
7 Disconnect Servicing is quick and safe
Electrical
8
Junction Box
Prevents unwanted backdrafts
Spring loaded aluminum to eliminate rattling and backdrafts
Round - For quick and easy
connections
Square - For quick and easy
connections
Removes quickly for maintenance
Includes conversion from horizontal
to vertical discharge
Vertical electrical access to eliminate drilling holes
External electrical access to eliminate
removing motor pack, saving installation time
Eliminates drilling holes
(horizontal or vertical)
Absorbs sound
Large for easy wiring
Specific Features for Each Model
SP-A SP-B SP-C CSP-A CSP-B
Prepunched Prepunched
Prepunched
9 Attractive Grille
Mounting
10
Brackets
11 Housing
12 Motors
13 Access Panel
Exclusive Electrical Wiring Feature
Double Wide
Fans
Concealed attachment screws securely fasten grille to housing for quiet, rattle free operation
Adjustable for multiple installation conditions
Embossed galvanized steel for rigidity
A low profile for height restricted areas
All motors are compatible for use with speed controls and have thermal overload protection
Domestic & International
• 50 cycle, 220v or 240v
• 60 cycle, 115v, 208v, 220v, 230v, &
277v options
(See CAPS for availability)
Gain easy access to internal components once installed
Electrical access cover located on the housing exterior. This feature permits external wiring
without removing the power assembly, saving installation time and cost. Available on models SP-A and CSP-A.
Available for applications requiring 700 cfm or greater.
Double wide fans have two double width forward-curved wheels, which are housed in separate scrolls, and driven by a single motor. Available on models SP-A and CSP-A.
60 cycle,
115v only
Vertical Discharge
Exhaust outlet duct installed in the optional vertical position. The power
assembly must be rotated to match the duct adapter position. Available on models SP-A and CSP-A.
5
Page 6
Options and Accessories
Ceiling Radiation Damper
The National Fire Protection Association (NFPA) Standard 90A requires openings in fire rated ceiling/
floor assemblies to be protected by appropriately rated ceiling radiation dampers. As a result, many local codes require fans installed in fire rated ceilings to be protected by dampers which are insulated against both heat and flame.
UL Classified ceiling radiation dampers are rated at
three to four hours of fire resistance. All model SP-A
fans and fan/light combinations are available with ceiling radiation dampers. This design saves space
by allowing the damper to mount directly beneath the fan.
Model SP-A
SP-A Fan
Hanging Vibration Isolation
Ceiling Radiation Damper
3 in.
AxB
Grille
Fire Rated Ceiling
Contractor 4 Packs
Save installation time and labor by installing the housing first, then installing the internal components after the sheetrocking, plastering and finishing is done. Housings are packaged in one box, power assemblies and grilles are packaged in another box. Components are shipped to coincide with the phase of your project. (Model SP-B only).
Round Duct Connections
• 4 inch - SP models: B50, B70 and B80
• 6 inch - SP models: A50, A70, A90, B90, B110, B150, and B200
Model SP-B
SP-B Fan
Hanging Vibration Isolation
Ceiling Radiation Damper
3 in.
AxB
SP Model CRD Length Width Height
A50 - A190 310
B50 - B200 A200 - A390
A410 - A510 A710 - A780
A700 700
A900 - A1550
All dimensions shown in inches (millimeters). Add an “L” to all CRD models if fan & light combo is used. *CRD is approximately 1/4 inch (6 mm) larger than housing dimension. (See Installation, Operation and Maintenance Manual)
320
350
360 24
13
(343)
14
(365)
18
(468)
24
(614)
(614)
1
2
3
8
7
16
3
16
3
16
Fire Rated Ceiling
Grille
111⁄8
(283)
121⁄4
(311)
1415⁄16
(379)
121⁄4
(311)
1415⁄16
(379)
6
(76)
(76)
(76)
(76)
(76)
Round Duct Adapter
Optional - SP sizes A110 through A510
Wheel Options
Greenheck’s ceiling and cabinet fans (models SP and CSP) deliver high performance from a forward-
curved wheel. The forward-curved
wheel design offers both high-
efficiency and low sound. Fan
wheels are constructed of plastic
3
or steel as standard, and all models offer an aluminum wheel option.
3
• Level A models utilize steel
3
3
3
or plastic wheel construction
depending on size.
• Level B models are standard with
a plastic wheel.
Plastic
Steel
Aluminum
Page 7
SP Grille and Lighting Options
Grille Options
Designer is the standard grille for
SP models A50-A390 and B50-B200.
Available in white plastic finish, with or without motion detector or time delay (see following pages for motion detector and time delay information).
Decorative grille is optional on
A50-A390 and B50-B200. Available
in white plastic finish, with or without light, motion detector or time delay (see following pages for motion detector and time delay information).
Lighted Grille Options
Greenheck’s fan and light combinations include either a prismatic or a frosted lens and either compact fluorescent or incandescent lamps. Our unique light box is manufactured with a reflective material to increase the light given off by either type of lamp. UL Listed for above bathtub and showers
with GFCI branch protected circuit.
Model SP-A, sizes 50 - 390 Model SP-B, sizes 50 - 200
Prismatic Lens
The prismatic lens design provides
approximately 25% more light than
a traditional frosted lens. The lens
may be easily removed to replace light bulbs.
Frosted Lens
The frosted lens option is a
traditional design which lets
approximately 80% of light through the lens. The lens may be easily
removed to replace light bulbs.
Incandescent Lamps
One bulb provides up to 100 watts
of light (bulbs to be provided by others).
• Dimmable
• Reflective light box
Aluminum grille is optional on
A50-A390 and B50-B200. Standard on A410 and larger. Available in white
enamel finish.
Stainless Steel grille is optional on
A50-A390 and B50-B200. Available in
polished stainless steel finish.
Compact Fluorescent Lamps (CFL)
• Quick start bulbs (1 or 2 bulbs)
• Reective light box
• Produce 90% less heat
• Lower energy costs
• Two 13 watt CFL bulbs equals 100 watts of incandescent light.
Bulbs are included.
A major advantage of using CFL’s is to save money, as shown in the table below. This table assumes the
light is on for six hours per day and the electric rate
is 10 cents per kilowatt-hour. This study was based
over a 4½ year period.
27 Watt Compact
Fluorescent
Cost of Lamps $14.00 $0.50
Lamp Life 1,642.5 days (4.5 years) 167 days
Annual Energy Cost $5.91 $21.90
Lamps Replaced in 4.5 years
Total Cost $40.60 $103.55
Savings Over Lamp Life $62.95 $0.00
Source: U.S. Department of Energy, August 2001 Office of Energy Efficiency and Renewable Energy
0 10
100 Watt
Incandescent
7
Page 8
Control Accessories
Speed Controls
Speed controls may be used on model SP and CSP fans for manual adjustment of the fan’s performance (for final system balancing) or to control the fan’s output in confined spaces, such as conference
or meeting rooms. The fan can be adjusted to 60% of design airflow with a speed control. This reduction
in airflow and fan speed is also accompanied by a reduction in noise level. Solid state speed controls are available for a range of applications up to 15 amps. Speed controls can be used to operate more than one fan if the combined total amperage of the fans do not exceed the control rating.
SWITCHED FULL VOLTAGE
Dotted line indicates
for use with 10W
switch only.
VARIABLE
VOLTAGE
H
FULL VOLTAGE
120 VAC
RED
BLACK
WHITE
SPEED CONTROL
Internal Mounting
AUX
DEVICE
Switches
Switches may be used on model SP and CSP fans to enable manual control of your fan or fan and light
combination. There are several
options to fit your application.
NEMA 1 - Single pole rocker switch
assembly.
• Rated for, 115v, 15 Amp, 1/2 hp
• UL Listed
Model MS-16 - Single pole rocker switch assembly
with cover and pilot light.
• Rated for, 115v, 15 Amp, 1/2 hp
• UL Listed
NEMA 1 - Two pole rocker switch assembly.
• Rated for, 220/230/240/277v, 20 Amp, 2 hp
• UL Listed
• Requires a 2x4 handy box.
EXTERNAL JUMPER
FAN
N
LOAD
For use with shaded pole and permanent split
capacitor (PSC) motors. Available shipped loose or mounted internal or external.
SPEED CONTROL INTERNAL AND/OR EXTERNAL MOUNTING OPTIONS
Model
Voltage Rating
Amp Rating
5WSSC
115 - 127v
5 Amp
10WSSC
115 - 127v
10 Amp
15WSSC
115 - 127v
15 Amp
5W240
220 - 240v
5 Amp
8WSSC
220 - 240v
8 Amp
5W277
227v
5 Amp
NOTES: Speed controllers are not available for 208v applications. SP-C50 Speed Controller is shipped loose only. All speed controller options listed in table are UL Listed. Handy Box sizes are 2x4 for all options above except 10WSSC and 15WSSC, which are 4x4.
50 70 80 90 110 125 150 190 200 250 290 390 410 510 700 710 780 900 1050 1410 1550 1750 2150 3600
I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E No No No No No No
E E E E E E E E E E E E E E E E E E E E E E E No
E E E E E E E E E E E E E E E E E E E E E E E No
No No No *I/E I/E No I/E I/E *I/E No I/E I/E No I/E No No I/E No I/E No I/E No No No
No No No *E E No E E *E No E E No E No No E No E No E No No No
No No No No I/E I/E I/E I/E *I/E No No No No No No No No No No No No No No No
E = External mounted only I/E = Available Internal and External Mounted
KEY:
* Only available on the B-series (A-series is not available) No = Not available
Fan Sizes
8
LOAD
Page 9
Control Accessories
Gnd.
Hot
Black
Green
Red
Load
(12.5 Amps Max.)
Neutral
Black
Red
Black
White
White
Hot
Neutral
Ground
Motion Sensor
Fan Motor and/or
Light
Green
Time Delay Switch
Time delay switches save energy by automatically turning off equipment. They may be used with SP
and CSP fans or fan and light combinations for
extended operating time of fan. Time delay switches
act in the same manner as a standard switch,
however, there is a delay of 1 to 60 minutes after it
has been turned off.
(500 Watt Max)
BLACK BLUE
(NEUTRAL)
(HOT)
RED
WHITE
115 VOLT AC
60 CYCLE
Model GTD - A single switch controls both fan and
light. Available shipped loose.
• Silent Operation
• Rated for 115v
• UL Listed
• Requires 2x4 handy box
LIGHT
(7.5 Amps Max)
FAN MOTOR
Motion Detectors
Motion detectors may be used with SP and CSP fans or fan and light combinations. Motion detectors use a passive infrared motion detector to
automatically turn the fan on when a change in motion is sensed.
They have a viewing area of 180 degrees,
however they must be placed in the line-
of-sight. They also have an adjustable time delay shutoff setting of 1 to 20 minutes.
Wall Mount
Grille Motion Detectors are available on models up
through size SP-A390 and SP-B200.
• Rated for 115v
• UL Listed
Grille Mount
Transformers
Transformers are available for
applications requiring voltage reduction. Selection is based on motor amperage. All transformers are shipped loose.
Models Voltage Ratings Amp Ratings
T-2.0 230/277v to 115 2.0 Amps
T-4.3 230/277v to 115 4.3 Amps
T-6.5 230/277v to 115 6.5 Amps
T-8.6 230/277v to 115 8.6 Amps
277 V SUPPLY
BLK
BLK BLK
H1
2 H3
H
277V TO 115V TRANS.
750 VA
1 X2
X
RED
RED
SWITCH BOX
SWITCH
Model MDW
For use on fan or lights. Available shipped loose.
• Rated for 115v
• UL Listed
• Requires 2x4 handy box
115 V MOTOR
9
Page 10
Filters and Discharge Accessories
RJ-10x10
C
D
E
A
B
Filters
Fans used in most applications will collect airborne
dirt on wheels and motors over time, even where air is not excessively dirty. Accumulations of dirt on the fan wheel will sharply reduce performance and cause imbalance. Dirt buildup on the motor can cause it to overheat. All of these conditions will shorten the
life of the fan. To help reduce this accumulation,
washable aluminum mesh filters are available to trap
dirt before it enters the fan. These filters should be regularly cleaned to maintain performance. The Filter Loss Chart shows the effect the filter will have on performance. To determine the added resistance,
divide the desired cfm by the filter area (ft2). This will
give FPM. Use this with the filter loss chart to get the added resistance. Filters reduce sound levels, in
addition to reducing dirt accumulations on the motor and wheel.
Mesh Filter
Roof Discharge Accessories
Model RJ - Pitched Roof Cap
• Steel construction with black enamel finish
• Integral flashing flange
• Built-in birdscreen and damper
RJ-4 and RJ-6x9
E
D
A
D
E
A
C
B
RJ-10x10
C
B
SP Grille
.24
.22
.20
.18
.16
.14
.12
.10
.08
.06
.04
.02
.00
0 1 2 3 4 5 6 7 8 9 Velocity FPM x 100
Filter Loss Chart
Filter Model Filter
SP Model
SP-A50 - A190 F-200 F-210 0.739 SP-B50 - B200, A200 - A390 F-200 F-220 0.911 SP-A410 - A510
SP-A710 - A780 SP-A900 - A155 NA F-260 2.078
*Aluminium or Stainless Steel Grille.
Designer
Grill
*Metal
Grille
NA F-250 1.518
10
Area
Model For use with sizes: A B C D E Throat
91⁄4
81⁄4
55⁄16
41⁄2
RJ-4 C50, B50-B80
RJ-6x9 B90-B200, A50-A390
RJ-10x10 A410-A1050
All dimensions shown in inches (millimeters).
11
(279)
183⁄4
(476)
18
(470)
1
2
(235)
141⁄4
(362)
271⁄2
(699)
(210)
141⁄2
(368)
153⁄4
(400)
(135)
103⁄8
(264)
235⁄8
(600)
(114)
61⁄2
(165)
91⁄2
(241)
4 (102)
diameter
6 x 9
(152 x 229)
10 x 10
(254 x 254)
Model EL-10x3 - Elbow Discharge with Grille
• Designed for installation under roof eaves
• Painted steel louvered grille
• Built-in damper
• For model SP and CSP sizes 50-290
11.125
10
(254)
3.5 (89)
2.875 (73)
2
)
(ft
6.5 (165)
1.625 (42)
3.375 (86)
5.125
(130)
All dimensions shown in inches (millimeters).
(283)
9.375
(238)
11.5 (292)
Page 11
Flat Roof Caps
RJ-10x10
B
Dia.
D
C
A
RJ-4 and RJ-6x9
B
C
D
Dia.
A
1.75
(44)
B
Dia.
D
C
A
B
C
D
Dia.
A
B
E
C
A
D
E
D
A
G
C
B
E
F
1.5
(38)
C
D
E
A
B
D
C
B
A
E
RCC-7
GRS
GRSF
RFC
RJ-10x10
RJ-4 and RJ-6x9
B
C
D
Dia.
1.75
(44)
B
Dia.
D
C
A
B
C
D
Dia.
C
D
E
A
B
D
C
B
A
E
RCC-7
GRS
GRSF
RFC
RJ-10x10
B
C
D
Dia.
1.75
(44)
B
C
D
Dia.
C
D
E
A
B
GRS
GRSF
RFC
B
C
D
Dia.
A
GRS
GRSF
GRSF
Model RCC-7 - Curb Cap
• Weathertight aluminum construction
• Integral birdscreen
• Built-in curb cap
B
• Requires roof curb
Dia.
A
Model
RCC-7 50-390 15 All dimensions shown in inches (millimeters).
For use
with all
sizes:
A B C D
(381) 12 (305) 10 (254) 6
3
8 (162) 7 (178)
Model GRS - Curb Cap
• All aluminum exterior construction
• Galvanized steel
internal supports
• Integral birdscreen
• Built-in curb cap
• Requires roof curb
Model
GRS-10 410-710 19 GRS-12 780-1050 22 (559) 29 (737) 77⁄8 (200) 31⁄4 (83) 121⁄4 (311) GRS-16 1410-2150 26 (660) 29 (737) 83⁄4 (222) 33⁄4 (95) 165⁄16 (414) GRS-20 3600 30 (762) 351⁄2 (902) 91⁄4 (235) 41⁄4 (108) 205⁄16 (516) All dimensions shown in inches (millimeters).
For use
with all
sizes:
A B C D
(483) 20
Model RFC-7 - Flashing Flange
B
C
D
Dia.
A
1
2 (521) 61⁄4 (159) 3 (76) 101⁄4 (260)
C
D
1.75
1.5
(38)
Throat
Dia.
(44)
Throat
Dia.
Model GRSF - Flashing Flange
• All aluminum exterior construction
• Galvanized steel internal supports
• Integral birdscreen
B
• Built-in flashing flange
D
Dia.
A
Model
GRSF-10 410-710 23 GRSF-12 780-1050 26 (660) 29 (737) 77⁄8 (200) 31⁄4 (83) 121⁄4 (311) GRSF-16 1410-2150 30 (762) 29 (737) 83⁄4 (222) 33⁄4 (95) 165⁄16 (414) GRSF-20 3600 34 (864) 351⁄2 (902) 91⁄4 (235) 41⁄4 (108) 205⁄16 (516) All dimensions shown in inches (millimeters).
For use
with all
sizes:
A B C D
1
(584) 20
2 (521) 61⁄4 (159) 3 (76) 101⁄4 (260)
Hanging Vibration Isolators
Vibration isolator kits are available for suspended installations. Kits include all hardware necessary
to mount one unit, with the exception of 1/4-20 threaded rod to be supplied by others. Fan
mounting brackets include prepunched mounting holes for ease of installation.
1/4-20 hanging support
rod by
others
A
B
C
Throat
Dia.
• Weathertight aluminum construction
• Integral birdscreen
• Built-in flashing flange
For use
with all
sizes:
A B C D
(457) 12 (305) 10 (254) 6
Model
RFC-7 50-390 18 All dimensions shown in inches (millimeters).
D
Throat
C
Dia.
B50-B200 41⁄2 (114) 155⁄8 (397) A50-A190 51⁄2 (140) 145⁄8 (371) A200-A390 63⁄4 (171) 151⁄2 (394) A410, A510, A710, A780 91⁄4 (235) 195⁄8 (498) A700 51⁄2 (140) 251⁄8 (638) A900-A1050, A1410-A1550 91⁄4 (235) 253⁄8 (645) A1750, A2150 91⁄4 (235) 363⁄4 (933) A3600 91⁄4 (235) 485⁄8 (1235) All dimensions shown in inches (millimeters).
B
Dia.
A
3
8 (162) 7 (178)
Unit Size A B
11
Page 12
Wall Discharge Accessories
RJ-10x10
B
C
D
Dia.
A
1.75
(44)
D
C
B
C
D
Dia.
A
D
A
G
C
B
E
F
C
D
E
A
B
GRS
GRSF
RJ-10x10
B
C
D
Dia.
A
1.75
(44)
B
Dia.
D
C
A
B
C
D
Dia.
A
B
E
C
A
D
E
D
A
G
C
B
E
F
C
D
E
A
B
GRS
GRSF
RJ-10x10
B
Dia.
D
C
A
RJ-4 and RJ-6x9
B
C
D
Dia.
A
1.75
(44)
B
Dia.
D
C
A
B
C
D
Dia.
A
A
B
1/4-20
hanging
support
rod by others
B
E
C
A
D
E
D
A
G
C
B
E
F
6 (152)
dia.
4
(102)
dia.
6.25
(159)
1.5
(38)
C
D
E
A
B
D
C
B
A
E
RCC-7
GRS
GRSF
RFC
RDC-8
Model WC (Round Connection) - Hooded Wall Cap
• Aluminum construction - aluminum finish
• For outside wall applications
• Built-in birdscreen (not available on WC-4) and
damper
Model For use with sizes: A B C D E
WC-4 C50, B50-B80
WC-6 B90-B200, A50-A190
WC-8 A200-A510
All dimensions shown in inches (millimeters).
Model WL - Wall Louvered Discharge
• Anodized aluminum grille
• Built-in damper
• Not recommended for exterior applications
exposed to severe weather conditions. An external wall louver is recommended for such applications.
Model
WL-10x3 50-290
WL-18x6 390-1550
All dimensions shown in inches (millimeters).
12
C
A
E
D
For use with all
sizes:
B
E
E
1
2
6
(165)6 (152)4 (102)
8
(203)8 (203)6 (152)
11
(279)
D
11
(279)8 (203)
C
A
A B C D E
51⁄4
12
(305)
(133)
(254)
3
4
19
(502)8 (203)
(457)9 (229)6 (152)
10
18
23⁄4
(70)5 (127)
41⁄8
(105)5 (127)
51⁄8
31⁄2
(130)
(89)
B
73⁄4
31⁄2
(197)
(89)
Model RDC - Round Duct Connector
• Replaces the standard square discharge duct-
connector and damper
• Uses existing mounting holes
• Galvanized steel construction
• RDC-6 includes a damper
• RDC-8 does not include a damper
RDC-6
RDC-8
All dimensions shown in inches (millimeters).
Model TR 6x4 - Transition Duct Reducer
Model For use with sizes: Diameter
RDC-6 A110-A190 6 (152)
RDC-8 A200-A510 8 (203)
• Reduces duct from 6 to 4 inches.
• Galvanized steel construction
6 (152)
dia.
Model For use with sizes:
TR 6x4
All dimensions shown in inches (millimeters). *Used in conjunction with RDC-6.
6.25
(159)
B50-B200
A50-A90
A110-A190*
4
(102)
dia.
Page 13
Wall Discharge Accessories
C
1.75
(44)
B
C
D
Dia.
A
GRSF
30
20
10
9 8
7
6
5
4
3
2
.01 .02 .03 .04 .05 .06
.07 .08 .09
.10
.2 .3 .4 .5 .6
Pressure Drop in Inches wg
Above accessories tested with 4 feet of inlet duct
WC-10x3, WC-6, RJ-6x9, EL-10x3, WL-10x3, BVE-808, RFC-7, RCC-7
BVE-128, WC-8x8 WC-8
BVE-157, WC-18x8
RJ-10x10
WL-18x6
cfm x 100
Model WC - Hooded Wall Cap
(Square or Rectangular Connections)
• Steel construction with black enamel finish
• For outside wall applications
• Built-in birdscreen and damper
G
D
B
C
A
Model
WC-10x3 50-290
WC-8x8 200-510
WC-18x8 700-1550
All dimensions shown in inches (millimeters).
For use
with all
sizes:
A B C D E F G
1
2
123⁄4
(324)
101⁄4
(260)
201⁄4
(514)
31⁄2
(89)
81⁄4
(210)
81⁄4
(210)
5
(140)
10
(260)
10
(260)
1
4
1
4
101⁄4
(260)
81⁄4
(210)
181⁄4
(464)
F
E
111⁄8
(283)
81⁄4
(210)
181⁄4
(464)
Accessory Pressure Drops
The chart below can be used with all of the
discharge accessories shown on these two pages. Specific pressure drop values for these accessories must be included in total system calculations for proper fan selection.
41⁄4
(108)5 (127)
63⁄4
(171)5 (127)
63⁄4
(171)5 (127)
Model BVE - Brick Vent
• Designed for installation in masonry walls
• Anodized aluminum construction
• Built-in aluminum mesh insect screen
Model
BVE808 50-290
BVE128 390-510
BVE157 700-1050
All dimensions shown in inches (millimeters).
For use
with all
sizes:
A B C
1
8
8
(206)
12
(305)
5
8
15
(397)
73⁄4
(197)4 (102)
73⁄4
(197)4 (102)
73⁄4
(197)4 (102)
13
Page 14
Things to know when sound is critical
Sound Data
The sound data shown in this catalog has been presented to aid the system designer in selecting a fan which
will meet the desired sound criteria. Sone levels have been included on the performance pages to provide a means of quickly evaluating the relative loudness of a fan selection.
What is a sone?
Sones are an internationally recognized unit of loudness. In practical terms, the loudness of one sone is
equivalent to the sound of a quiet refrigerator measured from five feet away in an acoustically average room. A sone is a single number rating, which indicates the inlet noise derived from the eight audible octave bands.
Sones are a linear measurement of sound level. For example, a sound level of 10 sones is twice as loud as
5 sones.
What is the difference in an AMCA Sone vs. an HVI Sone?
In general, the AMCA (Air Movement and Control Association) sone value is focused on commercial markets, whereas the HVI (Home Ventilating Institute) sone value is focused on residential markets. Both calculate their sone data from the same raw test data (eight octave bands), however an AMCA sone applies a hemispherical
correction factor to the sound power and rounds to the nearest 0.1, whereas HVI applies a spherical correction factor to the sound power and rounds to the nearest 0.1 under 1.5 sones and to the nearest 0.5 for 1.5 sones and greater. There are no conversions from one sone to the other, each must be calculated. In every instance,
the same fan will have a lower HVI calculated sone rating than an AMCA calculated sone rating.
Can radiated noise increase the sound levels?
Radiated noise from fan housings can cause unacceptable sound levels, on any brand of fan. The size of
these fans allows them to be placed in areas where this noise will be transmitted to the conditioned space through walls or ceilings. Where possible, cabinet fans should be located in remote parts of the ventilation system.
When should a SP or CSP fan be used?
Model SP and CSP fans are designed for the lowest possible sound levels. Forward-curved wheels,
insulated housings and vibration isolators between the motor and housing contribute to quiet, efficient operation. Applied and installed as recommended, SP and CSP sound levels will fall well within the ranges
shown in the Suggested Limits for Room Loudness chart. For applications where sound levels are critical,
a remote mounted CSP with ductboard is recommended. Placement of SP and CSP fans should take into account the desired sound level at the location of the listener.
Suggested Limits for Room Loudness
Sones DBA
1.3-4 32-48 Private homes (rural and suburban)
1.7-5 36-51 Conference rooms
2-6 38-54 Hotel rooms, libraries, movie theatres, executive offices
2.5-8 41-58 Schools and classrooms, hospital wards and operating rooms
3-9 44-60 Court rooms, museums, apartment houses, private homes (urban)
4-2 48-64 Restaurants, lobbies, general open offices, banks
5-15 51-67 Corridors and halls, cocktail lounges, washrooms and toilets
7-21 56-72 Hotel kitchens and laundries, supermarkets
Reprinted from AMCA Publication 302 (Application of Sone Ratings for Non-ducted Air Moving
Devices, with room—sone—dBA correlations) with the written permission from the AMCA
International, Inc., 30 West University Drive, Arlington Heights, IL 60004-1893.
NOTE: Values above are for room loudness and are not sound ratings. Room loudness is the resulting
level in a conditioned space after the acoustical qualities of the room have been accounted for.
14
Page 15
Things to know when sound is critical
Their compact size allows the system designer greater flexibility in locating these fans for lowest sound
levels. In critical sound areas, insulated ductwork, flexible duct connections, or placing the fan in a remote section of the ductwork (away from the critical area) offers the best means of meeting desired sound levels.
When room sound levels are critical, such as in executive offices, conference rooms, hospital operating rooms, and school study areas, a CSP fan is the best choice. Shown here is a comparison of SP and CSP fans
of the same size, with equal performance in typical installations. The CSP shows lower
sone values.
Model CFM WG FRPM Sones
SP-A410 405 1/8 1000 3.7
CSP-A410 426 1/8 1000 2.1
*Sone value with insulated inlet duct.
Fiberglass
Model SP mounted directly overhead may be too loud for sound critical applications.
Remote mounted model CSP with vibration isolators and insulated ductwork provides the quietest installation.
Model Number Code SP - A 50 FL
Light Options:
L - Fan/Light (Incandescent) Combination FL - Fan/Light (Fluorescent) Combination
Nominal cfm at 0.10 inches static pressure
Level of Construction:
A - Premium unit; lowest sound, insulated housing B - Deluxe unit; low sound, low profile C - Standard unit; lowest profile, inexpensive
Model:
SP - Silent Partner CSP - Cabinet Silent Partner
15
Page 16
Model SP-A
A
B
C
D
E
Premium Ceiling Fan
Model SP-A Dimensions
Model A B C D E
1
4
105⁄8
(270)
105⁄8
(270)
117⁄8
(302)
143⁄8
(365)
115⁄8
(295)
143⁄8
(365)
143⁄8
(365)
115⁄8
(295)6 (152)
101⁄2
(267)8 (203)6 (152)
111⁄4
(286)8 (203)8 (203)
141⁄2
(368)8 (203)8 (203)
115⁄8
191⁄2
(295)
(495)8 (203)
141⁄2
10
(368)
(254)8 (203)
141⁄2
183⁄4
(368)
(476)8 (203)
50, 70, 90
110, 125, 190
200, 250, 290, 390
410, 510
700
710, 780
900, 1050, 1410, 1550
All dimensions are in inches (millimeters) and weight in pounds (kilograms). Outlet connection width is 1 in. (25 mm) - Mounting bracket width is 1½ in. (38 mm). For complete dimensional information, see CAPS submittal drawings.
13
(337)
13
(337)
14
(356)
18
(457)
23
(600)
18
(457)
23
(603)
1
4
5
8
3
4
Designer
Grille
147⁄8 x 131⁄4
(378 x 337)
193⁄8 x 163⁄8
(492 x 416)
251⁄8 x 131⁄2
(638 x 343)
193⁄8 x 163⁄8
(492 x 416)
25 x 163⁄8
(635 x 416)
Decorative
151⁄4 (387) sq.
Grille
Unit
Weight
12
(5)
17
(8)
24
(11)
31
(14)
34
(15)
34
(15)
56
(25)
B
A
E
C
D
A
B
E
C
D
Model RPM Amps Watts
SP-A50
2, 3, 5
SP-A70
2, 3, 5
SP-A90
2, 3, 5
SP-A110
SP-A125
SP-A190
SP-A200
SP-A250
SP-A290
SP-A390
SP-A410
SP-A510
SP-A700
SP-A710
SP-A780
SP-A900
SP-A1050
SP-A1410
SP-A1550
2, 3, 4, 5, 6
2, 3, 5, 6
3, 4, 5, 6
3, 5
3, 5
3, 4, 5
3, 4, 5
3
3, 4
3
3
3, 4
3
3, 4
3
3, 4
700 0.31 18.3
850 0.27 20.2
900 0.34 29.4
950 0.58 48.7
1100 0.62 52.5
1400 1.30 113
900 0.43 48.2
1000 0.77 83.1
1050 0.72 80.7
1350 1.34 135
1000 1.74 121
1070 3.30 224
1100 3.20 350
1080 4.40 285
1600 3.30 348
950 4.00 285
1095 6.30 420
1450 7.40 786
1610 8.60 818
CFM 76 51 48 31
Sones 0.5 0.7 0.8 1.3
CFM 83 70 67 42
Sones 0.8 0.8 0.8 1.6
CFM 99 88 84 61 25
Sones 0.8 1.0 0.9 1.2 1.4
CFM 119 110 106 88
Sones 0.8 0.8 0.1 1.1
CFM 135 123 121 104
Sones 0.9 1.2 1.3 1.3
CFM 216 197 192 167 133
Sones 2.5 2.5 2.5 2.5 2.5
CFM 247 225 220 196 172 142 105 67
Sones 1.4 2.0 2.0 2.5 3.0 3.5 3.5 4.0
CFM 272 251 246 227 210 185 157 119
Sones 2.5 2.5 2.5 2.5 3.5 4.0 4.0 4.0
CFM 315 293 287 257 231 207 175 124
Sones 2.5 2.5 2.5 3.0 3.0 3.5 3.5 4.5
CFM 410 395 391 368 345 325 307 279
Sones 4.5 4.5 4.5 4.5 5.0 5.0 5.5 5.5
CFM 443 413 405 351 306
Sones 3.5 3.0 3.0 3.0 3.5
CFM 557 512 501 439 392 325
Sones 5.0 4.5 4.5 4.5 4.5 4.0
CFM 757 723 723 700 679 649 613 560 494 396
Sones 5.0 5.0 5.0 5.5 5.5 6.0 6.0 6.5 6.5 6.5
CFM 752 714 701 653 588 486 320
Sones 6.0 6.0 6.0 6.0 6.0 5.5 5.5
CFM 812 782 775 741 704 665 625 581
Sones 8.5 8.5 8.5 8.0 8.0 8.0 8.0 8.0
CFM 955 907 896 841 773 701
Sones 4.0 5.0 5.0 5.0 5.0 5.0
CFM 1125 1059 1043 964 885 796 662
Sones 6.0 6.0 6.0 6.0 5.5 5.5 5.5
CFM 1455 1415 1404 1353 1307 1262 1218 1174
Sones 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0
CFM 1607 1558 1558 1506 1449 1407 1369 1323
Sones 10.5 10.0 10.0 10.0 10.0 10.5 11.5 13.0
0 0.1 0.125 0.25 0.375 0.5 0.625 0.75 0.875 1
2 Available with light 3 Available with CRD - Ceiling Radiation Damper 4 Also available with 50 Hz motors
Performance certified is for model SP exhaust for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft damper. Speed (rpm) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in spherical fan sones at 5 ft (1.5m) in a spherical free field calculated per Annex B of AMCA 311. Values shown are for installation type B: free inlet spherical fan sone levels.
(See page 20 for performance)
CFM / Static Pressure in Inches wg
5 UL Listed for use above tubs. 6 Available with 277 volt motor.
16
Page 17
Model SP-B and SP-C
A
B
C
D
E
A
B
C
D
E
B
C
F
E
D
A
A
B
C
D
E
Deluxe and Standard Ceiling Fan
Model SP-B Dimensions
3/4
(19) 14
11⁄4
(32)
Designer
Grille
7
8 x 131⁄4
(378 x 337)
Model A B C* D E
7
8
111⁄2
(292)
111⁄2
(292)
615⁄16
(176)4 (102)
715⁄16
(202)6 (152)
50, 70 & 80
90, 110, 150, 200
All dimensions are in inches (millimeters) and weight in pounds (kilograms). *Add 1½ in. (38 mm) to C dimension for incandescent light. Mounting bracket width is 1½ in. (38 mm). For complete dimensional information, see CAPS submittal drawings.
13
(352)
13
(352)
7
8
Decorative
Grille
151⁄4 (387) sq.
Unit
Weight
9
(4)
10
(5)
B
A
D
E
C
Model RPM Amps Watts
SP-B50
2, 3, 5
SP-B70
2, 3, 5
SP-B80
2, 3, 5
SP-B90
2, 3, 4, 5
SP-B110
SP-B150
SP-B200
2 Available with light 3 Available with CRD - Ceiling Radiation Damper 4 Also available with 50 Hz motors (See page 20 for performance)
Performance certified is for model SP exhaust for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft damper. Speed (rpm) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in spherical fan sones at 5 ft (1.5m) in a spherical free field calculated per Annex B of AMCA 311. Values shown are for installation type B: free inlet spherical fan sone levels.
2, 3, 4, 5, 6
2, 3, 4, 5, 6
3, 4, 5, 6
625 0.50 37.8
675 0.53 45.1
900 0.60 54.3
700 0.65 49.7
950 1.14 80.2
1050 1.70 128
1100 2.20 172
CFM 67 54 51 40 29
Sones 1.2 1.4 1.4 2.0 3.0
CFM 77 71 68 57 49 39
Sones 1.2 1.4 1.4 2.0 2.5 3.0
CFM 87 80 78 68 61 54 44 30
Sones 2.0 2.0 2.5 2.5 3.0 3.5 4.5 4.5
CFM 101 89 88 75 59 45 30
Sones 1.5 2.0 2.0 2.5 3.0 3.5 4.0
CFM 133 114 110 97 95 94 91 85 72 50
Sones 1.5 1.5 1.5 2.0 2.0 2.0 3.0 3.5 4.0 4.5
CFM 160 156 155 154 152 149 147 138 123 92
Sones 2.5 2.5 2.5 3.0 3.5 3.5 4.0 4.5 4.5 5.0
CFM 197 195 194 191 187 184 181 166 151 128
Sones 3.5 4.0 4.0 4.5 4.5 5.0 5.0 5.5 5.5 5.5
0 0.1 0.125 0.25 0.375 0.5 0.625 0.75 0.875 1
Model A B C D E F
50
All dimensions are in inches (millimeters) and weight in pounds (kilograms). For complete dimensional information, see CAPS submittal drawings.
Model SP-C Dimensions
1
2
71⁄2
7
(191)
(191)
35⁄8
(92)3 (76)
15⁄8
(41)
Decorative
1/2
91⁄4 x 9
(13)
(235 x 229)5 (2)
Grille
Unit
Weight
CFM / Static Pressure in Inches wg
5 UL Listed for use above tubs. 6 Available with 277 volt motor.
B
E
C
A
D
F
Model RPM Amps Watts
SP-C50 1680 0.80 46
Performance certified is for model SP exhaust for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft damper. Speed (rpm) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in spherical fan sones at 5 ft (1.5m) in a spherical free field calculated per Annex B of AMCA 311. Values shown are for installation type B: free inlet spherical fan sone levels.
CFM 52 49 49 47 44 38 29
Sones 3.0 3.0 3.0 3.0 3.5 4.0 4.0
CFM / Static Pressure in Inches wg
0 0.1 0.125 0.25 0.375 0.5 0.625
17
Page 18
Model CSP-A
A
B
C
D
E
F
Inlet
G
Premium Inline Fan
Model CSP-A Dimensions
91⁄4
(235)
10
(254)
131⁄4
(337)
101⁄2
(267)
131⁄4
(337)
131⁄4
(337)
13
(330)
145⁄8
(371)
Unit
Weight
16
(7)
23
(10)
36
(16)
34
(15)
36
(16)
59
(27)
68
(31)
122
(55)
Model A B C D E F G
1
4
105⁄8
110, 125, 190
200, 250, 290, 390
410, 510
700
710, 780
900, 1050, 1410, 1550
1750, 2150
3600
All dimensions are in inches (millimeters) and weight in pounds (kilograms). Inlet and outlet connection widths are 1 in. (25 mm) - Mounting bracket width is 1½ in. (38 mm). For complete dimensional information, see CAPS submittal drawings.
13
(337)
14
(356)
18
(457)
5
23
(600)
18
(457)
3
23
(603)
35
(889)
1
45
(1156)
8
4
2
101⁄2
(270)
(267)8 (203)6 (152)
117⁄8
111⁄4
(302)
(286)8 (203)8 (203)
143⁄8
141⁄2
(365)
(368)8 (203)8 (203)
115⁄8
115⁄8
(295)
(295)
143⁄8
141⁄2
(365)
(368)
143⁄8
141⁄2
(365)
(368)
143⁄4
143⁄4
(375)
(375)
161⁄2
161⁄2
(419)
(419)
191⁄2
(495)8 (203)
10
(254)8 (203)
183⁄4
(476)8 (203)
28
(711)6 (152)
40
(1016)
(279)
11
12
(305)
127⁄8
(327)
167⁄8
(429)
225⁄8
(575)
167⁄8
(429)
225⁄8
(575)
323⁄4
(832)
431⁄4
(1099)
F
G
E
B
C
D
A
B
A
E
G
D
C
F
Inlet
Model RPM Amps Watts
CSP-A110 950 0.62 48.7
CSP-A125
CSP-A190
1100 0.63 52.5
6
1400 1.10 100.0
4, 6
CSP-A200 900 0.43 48.2
CSP-A250 1000 0.79 82.7
CSP-A290
1050 0.71 80.7
4
CSP-A390 1350 1.33 140.0
CSP-A410 1000 1.87 135.0
CSP-A510 1070 3.11 217.0
CSP-A700 1100 3.20 350.0
CSP-A710 1080 4.40 325.0
CSP-A780
1600 3.77 405.0
4
CSP-A900 950 4.87 328.0
CSP-A1050
1095 6.65 455.0
4
CSP-A1410 1450 7.80 822.0
CSP-A1550
1610 8.32 830.0
4
CSP-A1750 1130 6.60 550.0
CSP-A2150 1100 7.80 735.0
CSP-A3600 1100 7.10 1330.0
CFM 124 112 110 102 77
Sones 0.8 0.7 0.8 91.0 0.9
CFM 138 126 124 114 91
Sones 1.1 1.1 1.1 1.0 1.2
CFM 215 202 198 180 159 121
Sones 2.0 1.5 2.0 2.0 2.5 2.5
CFM 254 231 226 203 178 145 109 70
Sones 0.6 0.4 0.5 0.9 1.0 1.3 1.5 1.5
CFM 266 246 241 221 205 187 165 132
Sones 0.9 1.0 1.0 2.0 2.5 3.0 2.5 2.5
CFM 318 299 292 265 248 229 201 144
Sones 1.1 1.2 1.3 2.0 2.5 3.5 3.0 3.0
CFM 412 400 397 382 363 339 324 309
Sones 2.0 2.0 2.0 2.5 3.0 4.0 4.5 4.5
CFM 447 441 403 364 317 217
Sones 1.5 1.5 1.5 2.0 2.0 2.0
CFM 545 514 506 464 405 324
Sones 2.5 2.0 2.0 2.0 2.0 2.5
CFM 766 755 752 739 726 702 678 635 549 418
Sones 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.5 2.5 4.0
CFM 737 698 688 635 567 475 334
Sones 2.5 2.5 2.5 2.5 2.0 2.0 2.0
CFM 813 784 777 742 707 672 638 603 567 527
Sones 3.0 3.0 3.0 3.0 3.0 2.0 3.0 3.0
CFM 908 852 841 782 715 631
Sones 1.4 1.4 1.4 2.0 2.0 3.0
CFM 1182 1110 1093 1013 922 832 743
Sones 2.5 2.5 2.5 2.5 2.5 2.5 2.5
CFM 1584 1543 1533 1483 1439 1395 1345 1293 1238 1181
Sones 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 4.0 4.0
CFM 1672 1618 1604 1543 1484 1427 1367 1307 1240 1172
Sones 5.0 4.5 4.5 4.5 4.5 4.0 4.0 4.5 4.5 4.5
CFM 1842 1768 1749 1619 1464 1284 1032 772 484
Sones 5.0 5.0 5.0 4.5 4.0 4.0 3.5 3.0 3.0
CFM 2249 2175 2156 2044 1900 1701 1424 1114
Sones 5.0 4.5 4.5 4.0 4.0 4.0 3.0 3.0
CFM 3778 3653 3622 3460 3280 3091 2844 2551 2232 1750
Sones 5.0 5.0 5.0 6.5 4.5 4.0 4.0 4.0 3.5 3.5
4 Units also available with 50 Hz motors (See page 21 for performance) 6 Available with 277 volt motor.
Performance certified is for model CSP inline for installation type D: Ducted inlet, Ducted outlet. Performance ratings include the effects of a backdraft damper. Speed (rpm) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in spherical fan sones at 5 ft (1.5m) in a spherical free field calculated per Annex B of AMCA 311. Values shown are for installation type D: ducted inlet spherical fan sone levels. Ratings do not include the effect of duct end correction. Ratings are based on 10 ft of insulated duct. The AMCA Certified Ratings Seal applies to air performance ratings only.
0 0.1 0.125 0.25 0.375 0.5 0.625 0.75 0.875 1
CFM / Static Pressure in Inches wg
18
Page 19
Model CSP-B
A
E
D
C
B
F
G
A
B
C
D
E
F
Inlet
G
Deluxe Inline Fan
Model CSP-B Dimensions
Model A B C D E F G
7
8
111⁄2
(292)
715⁄16
(202)6 (152)
110, 150, 200
All dimensions are in inches (millimeters) and weight in pounds (kilograms). Outlet connection width is 1 in. (25 mm) - Mounting bracket width is 1½ in. (38 mm). For complete dimensional information, see CAPS submittal drawings.
Model RPM Amps Watts
CSP-B110
CSP-B150
CSP-B200
4 Units also available with 50 Hz motors (See page 21 for performance)
Performance certified is for model CSP inline for installation type D: Ducted inlet, Ducted outlet. Performance ratings include the effects of a backdraft damper. Speed (rpm) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in spherical fan sones at 5 ft (1.5m) in a spherical free field calculated per Annex B of AMCA 311. Values shown are for installation type D: ducted inlet spherical fan sone levels. Ratings do not include the effect of duct end correction. Ratings are based on 10 ft of insulated duct. The AMCA Certified Ratings Seal applies to air performance ratings only.
13
(352)
950 1.14 80
4, 6
1050 1.70 129
4, 6
1100 2.20 173
4, 6
11⁄4
101⁄4
(32)
31⁄4 (83)
(260)
CFM 103 100 100 98 97 96 94 86
Sones 1.5 1.5 2.0 2.0 2.0 2.0 2.5 2.5
CFM 151 150 149 148 144 146 142 135
Sones 2.0 2.0 2.0 2.0 2.5 2.5 3.0 3.0
CFM 186 184 189 182 181 179 175 170
Sones 3.0 3.0 3.0 3.0 3.5 3.5 3.5 3.5
6 Available with 277 volt motor.
Unit
Weight
101⁄4
(5)
Inlet FxG
E
B
CFM / Static Pressure in Inches wg
0 0.1 0.125 0.25 0.375 0.5 0.625 0.75
A
D - diameter
C
19
Page 20
Model SP
A
B
C
D
E
A
B
C
D
E
A
B
C
D
E
B
C
F
E
D
A
50 Cycle Performance
For uses in countries with 50 cycle (50 Hz) power,
Greenheck offers the same reliability and performance for ceiling mounted exhaust fans model SP.
• Same dimensions and outlet options
• Performance shown in 50 cycle RPMs
• Full line of grille and discharge accessories available
Model SP Dimensions
SP-A A B C D E
1
4
105⁄8
(270)
105⁄8
(270)
117⁄8
(302)
143⁄8
(365)
143⁄8
(365)
143⁄8
(365)
111⁄2
(292)
111⁄2
(292)
115⁄8
(295)6 (152)
101⁄2
(267)8 (203)6 (152)
111⁄4
(286)8 (203)8 (203)
141⁄2
(368)8 (203)8 (203)
141⁄2
10
(368)
(254)8 (203)
141⁄2
183⁄4
(368)
(476)8 (203)
615⁄16
(176)4 (102)
715⁄16
(202)6 (152)
50, 70, 90
110, 125, 190
200, 250, 290, 390
410, 510
710, 780
900, 1050, 1410, 1550
Outlet connection width is 1 in. (25 mm) - Mounting bracket width is 1½ in. (38 mm).
SP-B A B C D E
50, 70 & 80
90, 110, 150, 200
All dimensions are in inches (millimeters) and weight in pounds (kilograms). *Add 1½ in. (38 mm) to C dimension for incandescent light. Mounting bracket width is 1½ in. (38 mm). For complete dimensional information, see CAPS submittal drawings.
13
(337)
1
13
(337)
14
(356)
18
(457)
18
(457)
233⁄4
(603)
7
13
(352)
137⁄8
(352)
4
8
Standard
147⁄8 x 131⁄4
(378 x 337)
193⁄8 x 163⁄8
(492 x 416)
193⁄8 x 163⁄8
(492 x 416)
25 x 163⁄8
(635 x 416)
Designer
3/4
147⁄8 x 131⁄4
(19)
(378 x 337) 15
11⁄4
147⁄8 x 131⁄4
(32)
(378 x 337)
Grille
Grille
Decorative
Grille
151⁄4 (387)
square
Decorative
Grille
1
4 (387)
square
Unit
Weight
12
(5)
17
(8)
24
(11)
31
(14)
34
(15)
56
(25)
Unit
Weight
9
(4)
10
(5)
SP-A
B
C
A
E
D
SP-A (double wide)
A
B
E
C
D
SP-B
B
C
A
D
E
Model RPM Amps Watts
SP-A110
(50 Hertz Motor)
SP-A190
(50 Hertz Motor)
SP-A290
(50 Hertz Motor)
SP-A390
(50 Hertz Motor)
SP-A510
(50 Hertz Motor)
SP-A780
(50 Hertz Motor)
SP-A1050
(50 Hertz Motor)
SP-A1550
(50 Hertz Motor)
SP-B90
(50 Hertz Motor)
SP-B110
(50 Hertz Motor)
SP-B150
(50 Hertz Motor)
SP-B200
(50 Hertz Motor)
Model SP with 50 hertz motor is not AMCA certified.
950 0.29 49
1400 0.65 113
1050 0.36 81
1350 0.67 135
900 1.65 224
1334 1.65 348
950 3.15 420
1340 4.3 818
700 0.325 50
950 0.57 80
1050 0.85 129
1100 1.1 173
CFM 119 115 110 106 103 88
Sones 1.3 1.3 1.2 1.2 1.3 1.6
CFM 216 206 197 192 187 167 133
Sones 3.2 3.0 2.8 2.9 2.9 3.1 3.4
CFM 329 315 302 296 290 262 222 164
Sones 3.2 3.3 3.3 3.3 3.4 3.7 4.0 4.9
CFM 410 402 395 392 387 368 345 325
Sones 5.4 5.4 5.4 5.4 5.5 5.7 6.0 6.3
CFM 447 425 400 388 376 315 159
Sones 3.7 3.5 3.3 3.3 3.3 3.1 2.6
CFM 677 659 642 633 625 591 544 493
Sones 8.8 8.9 8.8 8.7 8.6 8.2 8.1 8.1
CFM 990 945 905 886 867 769 531
Sones 7.2 7.0 6.8 6.8 6.8 6.6 6.5
CFM 1337 1314 1290 1279 1266 1211 1161 1112
Sones 11.1 10.7 10.6 10.6 10.6 10.5 11.6 13.5
CFM 102 97 92 88 86 75 59 45
Sones 1.9 2.2 2.6 2.7 2.7 3.0 3.6 4.1
CFM 133 124 114 110 107 97 95 94
Sones 2.0 2.0 2.1 2.2 2.2 2.4 2.7 2.8
CFM 160 158 156 155 155 154 152 149
Sones 3.0 3.1 3.3 3.3 3.4 3.7 4.3 4.5
CFM 197 196 195 194 194 191 187 184
Sones 4.4 4.7 4.6 4.7 4.9 5.1 5.6 5.8
0.000 0.050 0.100 0.125 0.150 0.250 0.375 0.500
CFM / Static Pressure in Inches of wg.
20
Page 21
Model CSP
A
B
C
D
E
F
Inlet
G
A
E
D
C
B
F
G
A
B
C
D
E
F
Inlet
G
50 Cycle Performance
For uses in countries with 50 cycle (50 Hz) power,
Greenheck offers the same reliability and performance for inline cabinet fans model CSP.
• Same dimensions and outlet options
• Performance shown in 50 cycle RPMs
• Full line of discharge accessories available
Model CSP Dimensions
91⁄4
(235)
10
(254)
131⁄4
(337)
101⁄2
(267)
131⁄4
(337)
131⁄4
(337)
13
(330)
145⁄8
(371)
31⁄4
(83)
Unit
Weight
16
(7)
23
(10)
36
(16)
34
(15)
36
(16)
59
(27)
68
(31)
122
(55)
Unit
Weight
101⁄4
(5)
CSP-A A B C D E F G
1
4
105⁄8
110, 125, 190
200, 250, 290, 390
410, 510
700
710, 780
900, 1050, 1410, 1550
1750, 2150
3600
CSP-B A B C D E F G
110, 150, 200
All dimensions are in inches (millimeters) and weight in pounds (kilograms). Inlet and outlet connection widths are 1 in. (25 mm) - Mounting bracket width is 1½ in. (38 mm). For complete dimensional information, see CAPS submittal drawings.
13
(337)
14
(356)
18
(457)
5
23
(600)
18
(457)
233⁄4
(603)
35
(889)
1
45
(1156)
7
13
(352)
8
2
8
101⁄2
(270)
(267)8 (203)6 (152)
117⁄8
111⁄4
(302)
(286)8 (203)8 (203)
143⁄8
141⁄2
(365)
(368)8 (203)8 (203)
115⁄8
115⁄8
(295)
(295)
143⁄8
141⁄2
(365)
(368)
143⁄8
141⁄2
(365)
(368)
143⁄4
143⁄4
(375)
(375)
161⁄2
161⁄2
(419)
(419)
111⁄2
715⁄16
(292)
(202)6 (152)
191⁄2
(495)8 (203)
10
(254)8 (203)
183⁄4
(476)8 (203)
28
(711)6 (152)
40
(1016)
(279)
11
11⁄4
(32)
12
(305)
127⁄8
(327)
167⁄8
(429)
225⁄8
(575)
167⁄8
(429)
225⁄8
(575)
323⁄4
(832)
431⁄4
(1099)
101⁄4
(260)
CSP-A
F
G
E
B
C
D
A
CSP-A (double wide)
B
G
F
Inlet
A
E
D
C
CSP-B
D - diameter
Inlet FxG
E
B
A
C
Model RPM Amps Watts
CSP-A110
(50 Hertz Motor)
CSP-A190
(50 Hertz Motor)
CSP-A390
(50 Hertz Motor)
CSP-A780
(50 Hertz Motor)
CSP-A1050
(50 Hertz Motor)
CSP-A1550
(50 Hertz Motor)
CSP-B110
(50 Hertz Motor)
CSP-B150
(50 Hertz Motor)
CSP-B200
(50 Hertz Motor)
Model CSP with 50 hertz motor is not AMCA certified.
950 0.31 51
1400 0.55 100
1350 0.665 144
1334 1.885 405
950 3.325 455
1340 4.16 830
950 0.57 80
1050 0.85 129
1100 1.1 173
CFM 124 116 112 110 109 102 77
Sones 1.1 1.1 1.1 1.1 1.1 1.3 1.3
CFM 215 202 198 180 159 121
Sones 2.3 2.0 2.2 2.7 2.9 3.0
CFM 412 400 397 382 363 339 324 309
Sones 2.8 2.7 2.8 3.2 3.7 4.7 5.5 6.5
CFM 685 656 648 609 562 520 481
Sones 5.0 4.9 4.8 4.7 4.6 4.7 4.9
CFM 1079 1031 982 957 934 841 655
Sones 6.3 6.3 6.0 5.9 5.9 6.0 5.5
CFM 1391 1326 1311 1240 1171 1098 1019 929
Sones 7.5 7.4 7.4 7.3 7.4 7.3 7.3 7.2
CFM 103 102 100 99 99 98 97 96 93
Sones 2.0 1.9 2.0 2.1 2.1 2.3 2.6 2.7 3.1
CFM 151 150 149 149 149 148 148 145 142
Sones 2.5 2.7 2.7 2.7 2.7 2.9 3.1 3.4 3.6
CFM 186 185 184 183 183 182 180 178 175
Sones 3.4 3.7 3.6 3.7 3.7 4.0 4.1 4.1 4.3
0.000 0.050 0.100 0.125 0.150 0.250 0.375 0.500 0.625
CFM / Static Pressure in Inches of wg
21
Page 22
Model SP Specifications
Models SP-A50 thru A1550
Ceiling mounted exhaust fans shall be of the centrifugal direct drive type. The fan housing shall be constructed of heavy-gauge galvanized steel. The housing interior shall be lined with 1/2 inch (13 mm) acoustical insulation. The outlet duct collar shall include an aluminum backdraft damper on all SP-A sizes and shall be spring loaded on size SP-A110 and larger. Outlet shall be adaptable for horizontal or vertical discharge. The designer grille for sizes SP-A50 through SP-A390 shall be constructed of high-impact polystyrene and for sizes SP-A410 through SP-A1550, the grille shall be constructed of aluminum. Grilles shall be non-yellowing.
The access for wiring shall be external. The motor disconnect shall be internal and of the plug-in type. The motor shall be mounted on vibration isolators. The fan wheel shall be of the forward-curved centrifugal
type and dynamically balanced. All fans shall bear the AMCA Certified Ratings program AMCA Sound
and Air Performance seal and shall be UL/cUL Listed. Ceiling or wall mount fans shall be model SP as manufactured by Greenheck Fan Corporation, Schofield, Wisconsin.
*Model SP-A fans with 50 hertz motors are not AMCA certified.
Models SP-B50, B70, B80, B90, B110, B150, and B200
Ceiling mounted exhaust fans shall be of the centrifugal direct drive type. The fan housing shall be constructed of galvanized steel. The steel duct collar shall be 4 inch (102 mm) in diameter on the B50, B70, and B80 and 6 inch (152 mm) in diameter on the B90, B150, and B200 to accept 4 inch (102 mm) and 6 inch (152 mm) round ductwork and shall include a backdraft damper. The designer grille shall be constructed of non-yellowing high impact polystyrene and attached to the housing with hidden attachment screws. The access for wiring shall be external. The motor disconnect shall be internal and of the plug–in type.
The motor shall be mounted on vibration isolators. The fan wheel shall be of the forward curved centrifugal
type, constructed of calcium carbonate filled polypropylene and dynamically balanced. All fans shall bear
the AMCA Certified Ratings program AMCA Sound and Air Performance seal and shall be UL/cUL Listed. Ceiling or wall mount fans shall be model SP-B50, B70, B80, B90, B110, B150 or B200 as manufactured by Greenheck Fan Corporation, Schofield, Wisconsin.
*Model SP-B fans with 50 hertz motors are not AMCA certified.
Model SP-C50
Ceiling mounted exhaust fans shall be of the centrifugal direct drive type. The fan housing shall be constructed of galvanized steel. The plastic duct collar shall be a sleeve for ease of connection to 3 inch (76 mm) and 4 inch (102 mm) round ductwork and shall include a backdraft damper. The grille shall be
constructed of non-yellowing high impact polystyrene and attached to the housing with torsion springs.
The wheels shall be constructed of high-strength polymer. The access for wiring shall be easily accessible internally. The motor disconnect shall be internal and of the plug-in type. All fans shall bear the AMCA Certified Ratings program AMCA Air Performance seal. Model SP-C50 shall be UL Listed. Fans shall be model SP-C50 as supplied by Greenheck Fan Corporation, Schofield, Wisconsin.
*Model SP-C fans with 50 hertz motors are not AMCA certified.
22
Page 23
Model CSP Specifications
Models CSP-A110 thru A3600
Duct mounted exhaust, supply or return air fans shall be of the centrifugal direct drive type. The fan housing shall be constructed of heavy-gauge galvanized steel. The housing interior shall be lined with 1/2 inch (13 mm) acoustical insulation. The outlet duct collar shall include an aluminum backdraft damper and shall be adaptable for horizontal or vertical discharge. The access for wiring shall be external. The motor disconnect
shall be internal and of the plug-in type.
The motor shall be mounted on vibration isolators. The fan wheel shall be of the forward-curved
centrifugal type and dynamically balanced. All fans shall bear the AMCA Certified Ratings program AMCA
Air Performance seal and shall be UL/cUL Listed. Ceiling or wall mount fans shall be model CSP as manufactured by Greenheck Fan Corporation, Schofield, Wisconsin.
*Model CSP-A fans with 50 hertz motors are not AMCA certified.
Models CSP-B110, B150 and B200
Duct mounted exhaust, supply or return air fans shall be of the centrifugal direct drive type. The fan housing shall be constructed of galvanized steel. The steel duct collar shall be 6 inch (152 mm) in diameter to accept 6 inch (152 mm) round ductwork and shall include a backdraft damper. The access for wiring shall be external. The motor disconnect shall be internal and of the plug-in type.
The motor shall mounted on vibration isolators. The fan wheel shall be of the forward-curved centrifugal
type, constructed of calcium carbonate filled polypropylene and dynamically balanced. All fans shall bear
the AMCA Certified Ratings program AMCA Air Performance seal and shall be UL/cUL Listed. Ceiling or wall mount fans shall be model CSP-B110, B150 or B200 as manufactured by Greenheck Fan Corporation,
Schofield, Wisconsin.
*Model CSP-B fans with 50 hertz motors are not AMCA certified.
23
Page 24
Ceiling Fan Solutions
Ceiling Fans
SP-A110
SP-A50
Ceiling Fans
w/ Light
SP-A110
SP-A70
Ceiling Fans
w/ CRD
SP-A390
SP-A90
Ceiling Fans
w/ Light & CRD
SP-A125
SP-A90
SP-B50
SP-B90
SP-B200
SP-B80
Our Warranty
Greenheck Fan Corporation warrants its SP/CSP products to be free of any defect in material or workmanship for a period of three years from the date of shipment.
In the event of such a defect during the warranty period, Greenheck Fan Corporation
agrees, at its option, to either repair or replace the defective product free of charge.
This warranty runs to the original purchaser of such SP/CSP products for a period
of three years from the date of shipment. Any product repaired or replaced under this warranty will, itself, be warranted only for the remainder of the warranty period of the original product being repaired or replaced. All light bulbs are excluded under
this limited warranty. Greenheck Fan Corporation is not responsible for any removal,
installation, or transportation cost.
As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice.
P.O. Box 410 • Schofield, WI 54476-0410 • Phone (715) 359-6171 • greenheck.com
Copyright © 2010 Greenheck Fan Corp.
Prepared to Support
Green Building Efforts
SP CSP Rev. 7 January 2010
Loading...