GreenGuard Flashing User Manual

GreenGuard® Flashing Installation Guide
General Information
Installation of GreenGuard® Flashing shall be in accordance with applicable building codes and this Installation Guide. The Installation Guide shall be available at the jobsite during installation.
GreenGuard® Flashing is intended to provide protection against air and moisture intrusion by sealing around window/door openings, pipe penetrations, electrical and mounting box penetrations, fastener/wall tie penetrations. GreenGuard® Flashing can be used with most common building materials to seal the interface between the GreenGuard® Flashing and wall sheathing (plywood, OSB, extruded polystyrene insulation board), water-resistive barriers (building wraps/housewraps),
concrete, CMU, lumber, PVC (vinyl), berglass and metal.
Damaged substrates or materials shall be replaced prior to installation of the GreenGuard® Flashing.
Safety Precautions
• Review this Installation Guide prior to beginning installation. Refer to the Material Safety Data Sheet for additional information. Go to www.TrustGreenGuard.com for the most current product information.
• GreenGuard® Flashing is not compatible with coal tar,
polysulde sealants or plasticized PVC membranes.
Preparation
All surfaces to be bonded shall be dry, free from dust, dirt, loose debris and obstructions.
GreenGuard® Flashings are not intended to be used in areas intended for permanent exposure after construction is completed or on areas that will experience exposure to temperatures in excess of 150°F.
At the time of installation, the ambient air temperature shall be above 25°F. For applications at temperatures below 40°F, store GreenGuard® Flashing in heated area until use over surfaces prepared with one of the contact adhesives shown in the chart below. Contact adhesives improve adhesion to porous substrates such as CMU, exterior gypsum sheathing, and OSB at lower temperatures.
Apply contact adhesives in accordance with the manufacturer’s instructions, using a continuous coating with no puddles. Surfaces are typically ready for bonding when tacky and adhesive does not transfer when touched.
• CAUTION: Like most commercially available ashing
membranes, GreenGuard® Flashings are combustible
and may ignite if exposed to re of sufcient heat
and intensity. Protect GreenGuard® Flashing from
exposure to open ame or other ignition sources (such
as sparks or welding) during shipping, storage and installation.
Contact Adhesive Name Available Container Sizes Common Application
Carlisle Travel-Tack™ 15 oz. Aerosol Can Spray onto surfaces, allow to dry
Carlisle CAV Grip 40 lb. Aerosol Canister Spray onto surfaces, allow to dry
Carlisle CCW-02 (Solvent-Based) 1 gal. or 5 gal. Pails Sprayer, brush or roller, allow to dry
Carlisle CCW-AWP (Water-Based) 1 gal. or 5 gal. Pails Sprayer, brush or roller, allow to dry
Do not apply contact adhesives to surfaces that are wet, damp, frosty, or contaminated.
Apply contact adhesives to surfaces to be bonded with GreenGuard® Flashing in the same day. If the contact adhesive loses tack or becomes soiled, then re-apply
about 5 min. or until tacky
about 5 min. or until tacky
about 30 min.
about 30 min.
1-800-241-4402 www.TrustGreenGuard.com
GreenGuard® Flashing Installation Guide
Installation – General
A. Unroll the GreenGuard® Flashing and cut pieces using
a common utility knife. Be sure to cut pieces to allow for a minimum of 4 inches of overlap of intersecting
ashing pieces.
B. Begin by peeling back the release paper and pressing
the ashing rmly to the substrate, ensuring that there
are no wrinkles or bubbles. Continue to press and
smooth out the ashing, working along the sealed
area to ensure adequate bonding.
C. If additional pieces are necessary to span a wide
area, several courses can be installed by overlapping each course a minimum of 2 inches.
D. On wall applications, the edge of the ashing must
be kept at least ½ inch from the nished exterior and
must not come into contact with any visible sealants.
E. GreenGuard® Flashing shall be covered with the
nished exterior covering as soon as scheduling
permits.
Common Installation Details
IMPORTANT NOTE: For more specic installation details, go to www.TrustGreenGuard.com and download the
“GreenGuard® Moisture Management Residential or Commercial Installation Guides”.
Storage and Handling
• Protect GreenGuard® Flashing from exposure to excessive heat and cold. Store in clean, dry area in the original
cartons.
• If stored outdoors, protect the GreenGuard® Flashing from exposure to rain, direct sunlight, or other harmful
environmental conditions.
Standard Product Warranty
Pactiv warrants this product to be free from defects in workmanship and materials only at the time of shipment from its factory. If materials are determined to be defective, Pactiv will, at its option, replace the defective material or refund the
purchase price.
This limited warranty is the only warranty extended by Pactiv with respect to this material. NO OTHER WARRANTY, EXPRESS OR IMPLIED, IS GIVEN AS TO THE MERCHANTIBILITY, FITNESS FOR PARTICULAR PURPOSE, OR OTHERWISE
WITH RESPECT TO THE PRODUCTS REFERRED TO.
For more information on specic products, contact your Pactiv Building Products representative.
For the most current product information go to www.TrustGreenGuard.com.
GreenGuard® is a registered trademark of Pactiv LLC ©2013 Pactiv LLC
10/13 INSTL-FLASH
1-800-241-4402 www.TrustGreenGuard.com
Loading...