11.0 USAGE AND LIMITATIONS
GreenGuard® DC14 is intended to perform as a drainage mat in both commercial and residential construction applications when installed in accordance with this Guide. The following conditions apply to the use of the GreenGuard® DC14 Drainage Mat:
• GreenGuard® DC14 is a drainage mat that is used to manage water and wind-driven rain that
enters the wall assembly through the cladding or siding. The GreenGuard® DC14 is made from synthetic materials that are generally recognized as not providing a food source for insects, fungus, mold or mildew.
• GreenGuard® DC14 should be covered with the exterior cladding or siding within 60 days
of installation.
• When stored outdoors, GreenGuard® DC14 should be protected from exposure to direct sunlight
using the original packaging or an opaque, light-colored tarp. Material that has been unwrapped should be covered or rewrapped.
WARNING: Plastic drainage mat and building wraps will ignite if exposed to re of sufcient heat and intensity. Protect these products from exposure to open ame or other ignition source during shipment, storage and installation.
12.0 WARRANTY AND CONTACT INFORMATION
GreenGuard® Building Wrap Limited Warranty
Pactiv offers a 10-year Limited Warranty for all GreenGuard® Building Wraps.
For more information on specic building product recommendations and limitations,
contact your Pactiv representative.
For the most current product information, go to www.TrustGreenGuard.com
1-800-241-4402
www.TrustGreenGuard.com
GreenGuard® is a registered trademark of Pactiv LLC ©2014 Pactiv LLC 2/14 INSTL-DC14
GREENGUARD
DC14 Drainage Mat Installation Guide
®
MOISTURE MANAGEMENTGREENGUARD
1-800-241-4402
www.TrustGreenGuard.com
GREENGUARD® DC14 INSTALLATION GUIDE FOR COMMERCIAL AND RESIDENTIAL CONSTRUCTION
TABLE OF CONTENTS
1.0 GENERAL INFORMATION 2
2.0 INDUSTRY STANDARDS/CODE COMPLIANCE REQUIREMENTS 2
3.0 PRODUCT DESCRIPTIONS 2
4.0 FASTENERS AND FASTENING OPTIONS 2
5.0 FLASHINGS AND JOINT/SEAM SEALING PRODUCTS 3
6.0 INSTALLATION OF WATER-RESISTIVE BARRIER/GREENGUARD BUILDING WRAPS 3-4
7.0 INSTALLATION OF GREENGUARD® DC14 DRAINAGE MAT 5-6
8.0 INSTALLATION OF GREENGUARD® DC14 IN RESIDING APPLICATIONS 6
9.0 INSTALLATION OF GREENGUARD® DC14 AS THE WATER-RESISTIVE BARRIER IN RESIDING APPLICATIONS 6-7
10.0 REPAIRING DAMAGED BUILDING WRAP AND DRAINAGE MAT 7
11.0 USAGE AND LIMITATIONS 8
12.0 WARRANTY AND CONTACT INFORMATION 8
1.0 GENERAL INFORMATION
This Guide describes the GreenGuard® DC14 Drainage Mat and its intended use in commercial and residential construction applications where it is installed in wall systems in combination with various types of exterior wall sheathings, water-resistive barriers and exterior coverings such as brick, stone, exterior insulation nish systems (EIFS), conventional stucco, vinyl, ber cement, wood, etc.
This Guide is intended to provide installation guidelines for the
use of GreenGuard® DC14 Drainage Mat. These guidelines
are not intended to address all possible combinations of construction materials that may be used in a wall system. For this reason, the installation information provided is intended only as a guide and is for the convenience of contractors, speciers and other interested parties.
3.0 PRODUCT DESCRIPTIONS
GreenGuard® DC14 Drainage Mat – This product is an extruded
polystyrene insulation board product designed with contoured channels that allow for enhanced drainage performance. The product meets the requirements of “ICC-ES Acceptance Criteria for Foam Plastic Insulation” (AC12) and “ICC-ES Acceptance Criteria for Foam Plastic Panels Used as Water-resistive Barriers” (AC71).
4.0 FASTENERS AND FASTENING OPTIONS
GreenGuard® DC14 Drainage Mat is mechanically attached
either through structural sheathing board or insulation board to underlying framing members or attached directly to framing members. The following chart shows the fastening information for various framing and wall types:
2.0
INDUSTRY STANDARDS/CODE COMPLIANCE REQUIREMENTS
GreenGuard® DC14 Drainage Mat meets the requirements of
the 2006, 2009 and 2012 International Building, Residential and Energy Codes (IBC, IRC and IECC). These codes require that foam plastic insulation materials meet specic ame spread and smoke developed ratings. Applications involving the use of cementitious exterior coverings, such as exterior insulation nish systems (EIFS), conventional stucco and adhered thin masonry veneers (brick/stone), require the use of two layers of Grade D building paper or equivalent. This requirement can be met by using one layer of a water-resistive barrier (building wrap) and one layer of GreenGuard® DC14
Drainage Mat.
• International Code Council, Evaluation Services, Inc. (ICC­ES) - GreenGuard® DC14 Drainage Mat (see ESR-2136). The product is a recognized water-resistive barrier.
• National Building Code of Canada, GreenGuard® Fanfold Underlayments (Evaluation Report 12764-R)
1-800-241-4402 www.TrustGreenGuard.com
GreenGuard® DC14 Drainage Mat
Minimum Required Metal Wood Masonry
Roong Nail or Screw Type: Corrosion-resistant (Example: galvanized, hot dipped)
GreenGuard Caps or
Metal/Plastic Washers,
(Min. diameter)
Max. Fastener Spacing (inches)
Note: When attaching wall ties for anchoring masonry exterior claddings, rst install a patch of GreenGuard® Flashing at the penetration site before installing the wall tie. The patch should be of a size to seal only the penetration points.
15/
in. 15/
8
13/
in 13/
4
24 24 24
in.
8
in 13/
4
13/
in.
4
Tap Con
in
4
2