GreenBrook VCT4KW, VC3KW, VC4KW, VCT3KW, VCT3KSC Installation Instructions

...
Installation Instructions for:-
Vela Compact’ Range
LED 30, 60 & 90 Mins
Fire Rated Mains Voltage
immable Downlights
D
art numbers:
P Fixed:- VC3KW & VC4KW Tilt:- VCT3KW, VCT4KW
VCT3KSC, VCT4KSC
CT3KPC, VCT4KPC
V
IMPORTANT INFORMATION
It is recommended that luminaires are installed and fitted by a qualified electrician ensuring the installation complies to the current IET wiring regulation.
If simply replacing existing fitting, please ensure you follow these instructions and the appropriate wiring regulations. This product is designed for connection to a 230V AC Mains supply.
Always switch off mains supply before servicing a fitting. Special attention should be paid to any installations with low ceiling voids. This fitting is compatible with most trailing edge dimmers for best results use a dimmer designed for LED drivers. Please note that many dimmers have a minimum load requirement which may mean multiple units have to be connected for the dimmer to function correctly. Please see our website at www.greenbrook.co.uk for details of compatible dimmers.
INSTALLATION INSTRUCTIONS
We recommend that a sample hole is cut in some scrap material to familiarise yourself with the installation. Once you are completely satisfied, locate the areas suitable to install these luminaires. Cut a suitable round hole in the ceiling (see cut out size in table overleaf) and ensure there is sufficient space in the ceiling void without infringing on joist, water pipes or electrical cables.
Fit this product as illustrated in Dia 2. Connect this product to a mains 230V supply only. Connect the Brown feed wire to “L”, connect the Blue feed wire to “N”. Driver is class 2 and does NOT require an earth connection. The nearest illuminated sur face must be at least 0.5m distance away from the front of the fitting. Do not install this product into new plaster or damp areas.
Stage 1 -
Read instructions and check you have all the tools and accessories to complete installation correctly.
Dia.1
These luminaires are suitable for a 30, 60 or 90 minute fire rated ceiling only. Cut a suitable hole (sizes shown in the technical information table overleaf).
Dia.2
Press springs back and push luminaire body into aperture. Connect the luminaire to the supplied driver.
Dia.3
Dia.4
Additional Bezels:­Fixed
EDDLCBEZSC Satin Chrome
L
EDDLBCEZPC Polished Chrome
L
Tilt
ezels on tilt fittings are not inter changeable
B
TECHNICAL INFORMATION
ated Voltage: 230V~50Hz
R Circuit Wattage: 7W Ballast Type: LED driver
lass: II
C
urrent: 350mA
C CRI: >80
acAdam Steps: <3
M Energy Efficiency Class: F Standby Power: 0.2W
IP Rating: IP65 Life Span: 30,000 hours
VC3KW
Cut Out: 60mm
olour Temp: 3,000K
C Luminaire Lumens Output: 620 lm Beam Angle: 60º
VC4KW
Cut Out: 60mm Colour Temp: 4,000K Luminaire Lumens Output: 640 lm Beam Angle: 60º
VCT3KW/VCT3KSC/VCT3KPC
Cut Out: 76mm Colour Temp: 3,000K Luminaire Lumens Output: 620 lm Beam Angle: 40º
VCT4KW/VCT4KSC/VCT4KPC
Cut Out: 76mm Colour Temp: 4,000K Luminaire Lumens Output: 640 lm Beam Angle: 40º
FIXED)
(
IP44
TILT)
(
Your GreenBrook LED Fire Rated Downlight
is guaranteed for 3 years from the
This is in addition to your statutory rights.
GUARANTEE
date of purchase.
PLEASE KEEP THESE INSTRUCTIONS
SAFE FOR FUTURE REFERENCE
Replaceable (LED Only)
light source by an
end-user
WEST ROAD . HARLOW ESSEX . CM20 2BG . UK
info@greenbrook.co.uk
www.greenbrook.co.uk
Replaceable control gear by an end-user
Issue no: 706421