GreenBrook T40S-C Installation & Operating Instructions Manual

The position of the override switch H does not affect the operation.With cover plate up, the red neon K is still visible, enabling you to check at a glance whether the light switch is in AUTO (programme mode), in which case the Neon K will come ON if programme is on and OFF if programme is off, or in MANUAL mode when it will flash.To access the controls mode when it will be off. To access the controls again, grip the cover plate with forefinger and thumb either side and ease cover forward.
CHANGING A LIGHT BULB
In the event of a light bulb “blowing” the light switch will fail to operate. Always disconnect power before replacing the bulb by pulling the fuse carrier ’A’ until the fuse is fully visible. It may be necessary to replace the fuse if the switch does not operate when the carrier is pushed back into position following bulb replacement. There is a slot in the base of the carrier which allows the old fuse to be pushed upwards and removed.
PROGRAMME PLANNER
In order to ensure that the set programmes do not overlap, it is advisable to plan beforehand, using the table below.
ON
OFF
e.g PROG 1
PROG No 2
PROG No 3
PROG No 4
PROG No 5
PROG No 6
TIME
20.10
TIME
23.06
MOTUWE
X
X
TH FR SA SU
X
X X X X
e.g. First programme will be set to come on at 8.10pm until 11.06pm everyday.
TROUBLESHOOTING
PROBLEMS & SOLUTIONS
1.If the digital display remains blank, press the RESET button. Also, check that the light bulb has not blown.
2.If the light switch will not switch on or off in a one way circuit, check that the screws which fix the security light switch to the wall box have not been over tightened.
3.If the light will not switch on or off from either switch in a two way circuit ­(If the above does not solve this problem) the wiring may be incorrect, and requires re-checking. Check that the wire connected to the L2 terminal of the two way switch has been removed and reconnected to the C
(common) terminal. Incorrect wiring will often result in a blown fuse. Should the switch remain in-operative after correcting the error, replace the fuse with the spare provided.
4.If the light operates correctly from one switch in a two way circuit then the wiring is incorrect. Re-check to find error. Check that the wire connected to the L2 terminal of the two way switch has been removed and reconnected to the C (common) terminal.
5.If the digital display goes blank when the other switch in a two way circuit is operated, please refer to no. 4 above.
IF A PROBLEM ARISES SOME TIME AFTER INSTALLATION
If loss of time and programmes set occurs after the replacement of either a blown fuse, blown bulb or power failure ­Press the RESET button and reset the correct time and day and re-programme the required on and off times.
Every effort has been made to ensure that the guidance information on this sheet will enable the installation of the security light switch to be carried out safely and correctly.
TECHNICAL DATA
Rated Voltage: 230V, AC 50Hz Load: Max 400W–Min 40W + most
Low Energy (CFL) 11W & above
Integral 2 amp fuse
AALLWWAAYYSS RREEPPLLAACCEE WWIITTHH AA SSPPEECCIIAALL
22AAMMPP BBSS664466 FFUUSSEE.. ((TTHHIISS IISS NNOOTT AANN
OORRDDIINNAARRYY 22AAMMPP FFUUSSEE))
PPLLEEAASSEE KKEEEEPP TTHHEESSEE
IINNSSTTRRUUCCTTIIOONNSS SSAAFFEE FFOORR FFUUTTUURREE
RREEFFEERREENNCCEE
WEST ROAD . HARLOW ESSEX . CM20 2BG . UK
s a l e s @ g r e e n b r o o k . c o . u k
WWW.GREENBROOK.CO.UK
ELECTRONIC WALL
SWITCH TIMER
INSTALLATION/OPERATING
INSTRUCTIONS
MMOODDEELL NNUUMMBBEERR:: TT4400SS--CC
A
H
L
B
C
D
E
K
A.FUSE CARRIER Pull out to replace
fuse (a special 2A BS646 20mm x
5mm, this is not an ordinary fuse) B.LCD DISPLAY C. to G BUTTONS TO SET DAY, TIME
AND PROGRAMME AND RANDOM H.PUSH ON/OFF SWITCH ALLOWS
UNIT TO OPERATE AS ORDINARY
WHEN LID IS SHUT. L.OVERRIDE SWITCH
MAN = MANUAL MODE
AUTO = AUTOMATIC PROGRAMME
MODE J. RESET BUTTON K.RED NEON FUNCTION
IIFF IINN DDOOUUBBTT,, IINNSSTTAALLLLAATTIIOONN
SSHHOOUULLDD BBEE MMAADDEE BBYY AA QQUUAALLIIFFIIEEDD
EELLEECCTTRRIICCIIAANN IINN AACCCCOORRDDAANNCCEE WWIITTHH
CCUURRRREENNTT WWIIRRIINNGG RREEGGUULLAATTIIOONNSS
WIRING INSTRUCTIONS
Before attempting any installation work
n off the electrical supply at the mains
tur switch, fuse box or consumer unit and for additional safety remove the fuse. GreenBrook security wall light switches cannot be used with other electronic products.
1.After installation, the internal back up
battery will need to be fully charged to
enable correct operation.
2.After the main supply is switched back
on, wait 5 minutes and operate the
reset button and allow the internal
battery to charge for 45-60 minutes.
Issue no: 701559
After this period follow the operating
instructions as normal.
3.DO NOT use in two-way systems with
dimmers or any other switch
containing electronic circuitry.
4.Suitable for tungsten filament bulbs 40W to 400W maximum and most low
energy (CFL) 11W and above. Not
suitable for low voltage lighting.
5.Not suitable in 3-way circuits.
NNOOTTEE
If usin
g a metal backbox this should be
earthed.
WIRING INSTALLATION IN ONE
WAY SWITCHED CIRCUIT
Diagram 1- Before
J
G
F
Diagram 2 - After
YELLOW & GREEN EARTHS MUST REMAIN
CONNECTED TO METAL BACK BOX
WIRING INSTALLATION IN TWO
WAY SWITCHED CIRCUIT
Before installing your Security Wall Light Switch in a two way circuit, it is first necessary to determine which method of wiring has been used in your home. The primary reason for doing this is to make sure that the switch is wired in such a way that has a permanent live feed at all times in order to power the electronic timer.
1.TURN OFF THE MAIN SUPPLY
2.Loosen the two switch plates from
the wall.
3.Do NOT disconnect any wires at this stage.
4.Study the existing wiring arrangement; compare to the ‘before’ illustrations.
-If you find 3 wires at each switch (excluding the earth wire) see Diagram
3.-If you find 5 wires at one switch and 5 wires at the other (excluding the
earth wire) see Diagram 5. After establishing the appropriate wiring method, install the security light switch as per the corresponding ‘after’ illustration.
Diagram 3 - Before
3 Wires in both switches
Diagram 4 - After
Timer installed at live
wire end only
YELLOW & GREEN EARTHS MUST REMAIN
CONNECTED TO METAL BOX
WIRING INSTALLATION FOR
5 & 3 WIRE ARRANGEMENT
Diagram 5 - Before
5 & 3 wire arrangement
Yellow & Green earths must
remain connected to
metal box
Diagram 6 - After
Light switch timer at 3 wire end
Yellow & Green earths must
remain connected to
metal box
Diagram 7 - After
Light switch timer at 5 wire end
Yellow & Green earths must
remain connected to
metal box
C
PROGRAMMING LIGHT SWITCH
1. Ensure light fitting(s) being controlled have bulb(s) fitted, otherwise light switch will not function.
2. After installation is complete, reconnect power at the mains (remembering to replace fuse if removed for safety reasons). The red neon K and the L.C.D. display B will now be flashing. (Allow internal battery to charge for 45 minutes).
SETTING PRESENT
DAY & TIME
To access controls, with thumb and forefinger on either side, ease cover forward. With tip of ballpoint pen, press reset button J to clear memory. Press and hold down TIME button C continuously. Press DAY button D until present-day is displayed.Press HR and MIN buttons E and F until correct time is set using a 24-hour clock.Release TIME button C. e.g. L.C.D.display B showing current time is 3.15pm on Wednesday.
WE
15.15
NNOOTTEE
inued pressure on any of the
Cont
Y,HR,MIN buttons whilst TIME button
DA is depressed will advance the display rapidly.
SETTING A PROGRAMME
There are a maximum of 6 ON and 6 OFF times available. Each ON/OFF time can be used individually on any day(s) throughout the week, OR can be set to repeat on one of the following combination of days: to run a programme, override switch L must be in the auto position.
MO TU WE TH FR SA SU (days of the week); MO TU WE TH FR (weekdays); SA SU (weekends) MO TU WE TH FR SA (workdays only);
EXAMPLE 1
If you wish to switch light automatically every day of the week at 20:10 (8:10pm) and OFF at 23:06 (11:06pm).
STEP 1
Press the PROG button G and release.
MO TU WE TH FR SA SU TIMER _ _ : _ _ ON
The first time can be entered:
STEP 2
Press DAY button D until required day or combination of days is displayed. In the above case, press until ALL THE DAYS appear on the top.
STEP 3
Press HR button E until 20 shows:
MO TU WE TH FR SA SU
TIMER 20 : _ _ ON
STEP 4
Press MIN button F until 10 minutes are set:
MO TU WE TH FR SA SU
TIMER 20 : 10 ON
The colon in the centre will flash
STEP 5
Press PROG button G so that the first OFF time can be
MO TU WE TH FR SA SU TIMER - - : - ­OFF
STEP 6
Press HR button E until 23 shows:
MO TU WE TH FR SA SU TIMER 23 : - ­OFF
STEP 7
Press MIN button F until 06 minutes are set:
MO TU WE TH FR SA SU TIMER 23 : 06 OFF
STEP 8
Up to 6 ON and 6 OFF programmes are available and it is not necessary to use them all. Press TIME button C to revert back to clock.
entered:
EXAMPLE 2
If you wish to have a second programme which switches your light on at 18:00 hours (6.00pm) and off at 22.30 hours (10.30pm) every saturday and sunday only.
STEP 1
Press PROG button G and previous ON setting will appear. Keep pressing PROG G until you have stepped through all the previous ON/OFF settings and until you come to the first display, which has 4 dashes:
TIMER _ _ : _ _ ON
STEP 2
Press DAY button D until only SA and SU appear:
TIMER _ _ : _ _ ON
STEP 3 & 4
Press HR and MIN buttons E and F to set required ON time (zeros must be entered):
TIMER 18 : 00
ON
STEP 5
Press PROG button G to set OFF time:
STEP 6
Press DAY button D until both SA and SU appear as above:
SA SU
SA SU
STEP 7
Press HR and MIN buttons E and F to set required off time:
TIMER 22:30 OFF
SA SU
STEP 8
Press TIME C to revert back to CLOCK.
IIMMPPOORRTTAANNTT NNOOTTEE::
Ensure the day(s) selected in the programme
ON mode matches day(s)
selected into the programme OFF mode.
RANDOM FUNCTION
Once programming is completed, the lamp can be switched on and off at varying times on a daily basis if RANDOM FUNCTION is selected. Simply press DAY D and HR E buttons simultaneously. The word TIMER will flash to show RANDOM mode is activated. To cancel RANDOM, press DAY D and HR E simultaneously again and the word TIMER will disappear.
NOTE: The random feature works by randomly shifting the ON/OFF times of your set programmes between 2 and 30 minutes at each operation.
REVIEWING SET
PROGRAMMES
Press PROG G and on each occasion all previously set ON and OFF times will be displayed. Any alterations can be made by pressing button D, E and F as appropriate. Blank ON/OFF times will have 4 dashes instead of numbers. New programmes can be entered by following steps 1 to 8 in example 1.
AUTOMATIC OR MANUAL
CONTROL - OVERRIDE SWITCH
During those occasions when you are at home early and you do not want your security light switch to operate as programmed, slide switch L so that MAN shows for manual only operation. The pre-set programmes are still stored. The switch can operate only via push switch H. The red neon K will flash.To recall AUTOmatic programme (i.e. to activate switch to pre-set programmes) slide OVERRIDE switch L so that AUTO shows. Neon light K will come ON if programme is on and OFF if programme is off.
MANUAL ON/OFF OPERATION
When all settings have been completed, close the front cover plate until it clicks into position, concealing the operating controls. The room light(s) can be turned ON and OFF by simply pressing the top front cover once, or by operating the switch at the other end of a 2-way circuit.
Loading...