GreenBrook T105A-C Installation Instructions

nstallation/ Operating
16AMP(2)
I
Instructions for 7 Day
Electronic Socket Box Timer
T105A-C
-
Please read the instructions fully before attempting installation.
IMPORTANT
This unit should be installed to current
IET wiring regulations if in doubt
consult a qualified electrician.
• Timer must not be mounted on a flammable surface.
• Ensure at least a 300mm air space is allowed around the timer.
INSTALLATION
• Prepare cable ends for connection to terminals.
• Remove the 2 screws holding the timeswitch cover to the backplate. Remove cover leaving the timeswitch hanging loose by its connection wires to the backplate. DO NOT INTERFERE
WITH THESE FIXED CONNECTIONS.
WIRING
• Connect all earth wires to earthing point in wall box.
• Offer up the backplate to the wall box and connect the wiring as shown in diagram below.
IMPORTANT: Ensure all Terminal screws are fully tightened.
• When the wiring is complete screw the backplate to the fitted wall box using 3.5mm
screws.
• Push the timeswitch back in to its seating on the backplate, taking care that all the wires are tucked in. Fit the cover and tighten the two screws.
CURRENT TIME AND
DAY SETTING
1. Press the R button to reset the timer to its default settings, activate using a pencil or simular pointed instrument. (pressing R will delete all stored programmes).
. Press Y to enter function setup. (Note:
2
if another button is not pressed within 10 seconds the display will revert to the normal screen).
. Use the + or - button to scroll to the clock
3
icon (flashing) and press Y to enter the current time setting mode (hours flashing).
4. If you keep the + or - buttons pressed for more than 3 seconds, the display will enter
fast scroll mode.
5. Use the + or - button to adjust the hours
nd press Y to confirm, minutes will flash.
a
6. Use the + or - button to adjust the minutes and press Y to confirm, day will flash.
7. Use the + or - button to adjust the day and press N to exit.
PROGRAMMING THE
SWITCHING TIMES
1. There are 24 ON/OFF programmes available.
2. Press the Y button twice to enter the programming setting mode.(Note: if
another button is not pressed within 10 seconds the display will revert to the normal screen).
3. Default is programme 01 ON, this can be changed if required by pressing + or -
button to scroll through the 24 ON/OFF programmes as required, pressing the Y will confirm the programme.
4. Press the Y button to confirm programme 01 ON, hours will flash.
5. Use the + or - button to adjust the hours
and press Y to confirm, minutes will flash.
6. Use the + or - button to adjust the minutes and press Y to confirm, days will flash.
7. Apart from individual days of the week, the following day combinations of multiple day blocks can be selected by pressing the + or - buttons.
• Monday to Sunday
• Monday to Friday
• Saturday to Sunday
• Monday to Saturday
• Monday + Wednesday + Friday
• Tuesday + Thursday + Saturday
• Monday + Tuesday + Wednesday
• Thursday + Friday + Saturday
8. Select day or day block as required and press the Y button to confirm.
9. Press the + button, this will select the programme 01 OFF, press Y to confirm.
10.Follow 4 to 7 above to set the 01 OFF programme (day or day block must be the same as programme ON).
11.If no more programmes are required, press the N button to exit.
12.If more programmes are required follow 3 above.
13.To cancel a programme once set, press
and hold the N button for more than 3 seconds when the desired programme
umber is flashing i.e. to cancel
n programme 01 ON, press the Y button
twice and hold the N button down for
ore than 3 seconds to delete. Pressing
m the + button again will select 01 OFF.
14.Repeat 13 to delete 01 OFF. This procedure can be repeated to delete any
of the 24 programmes.
TIMER COUNTDOWN
FUNCTION
1. Timer has a 100 hour countdown feature i.e. the timer can be set to any period from
1 minute to 100 hours and will countdown in the ON state and turn OFF at the end of the countdown period.
2. Press the Y button then use the + or ­button to select the “down” icon on the right hand side of the display, press Y again to enter the countdown mode.
3. Use the + or - button to adjust the hours and press Y to confirm. minutes will flash.
4. Use the + or - button to adjust the minutes and press Y to confirm and complete the countdown time setting.
5. Press the N button to start the countdown.
6. Output switched to ON during the countdown period.
7. Press the N button to pause the countdown (output switched to OFF)
8. To resume countdown simply press the N button again.
9. Press and hold the N button for more than 3 seconds to exit the countdown function.
MANUAL OVERRIDE
1. When in normal clock mode, pressing the N button will scroll through the following switching options.
• ALWAYS ON - timer is permanently ON.
PROG - timer is in programme ON mode, will switch off at the next programme OFF time.
• ALWAYS OFF - timer is permanently OFF.
• PROG - timer is in programme OFF mode, will switch on at the next programme ON time.
SUMMER TIME SETTING
1. Press the Y button, then use the + or ­buttons to scroll through to “summer” (flashing).
2. Press the Y button again to access the summer time setting.
3. Press the + or - button to change between summer on or off.
4. Press Y to confirm summer setting, time will advance 1 hour.
5. A “SUMMER” icon will appear in the display.
6. Use the same procedure to remove the “SUMMER” icon when reverting to GMT in the winter.
RANDOM SETTING
The random setting allows the timer to switch ON and OFF with a random delay of between
2 and 32 minutes. This function will only operate if one or more programmes have
been programmed into the timer.
1. Press the Y button, then use the + or ­buttons to scroll through to “RANDOM” (flashing).
2. Press the Y button again to access the random setting.
3. Pressing the + or - buttons will toggle the random icon on and off.
4. Press the Y button to confirm random function.
5. A “RANDOM” function icon will appear in the display.
6. Timer will now operate in the random mode.
7. To cancel random feature use the procedure above to remove the “RANDOM” icon from the display.
READING YOUR
PROGRAMMED TIMES
1. Press Y button twice to enter programme mode.
2. Press the + or - buttons to scroll through the 24 ON/OFF programmes to check
settings.
3. Press the N button to exit and revert to clock mode.
RESET
Pressing the reset button R with a pencil or similar will reset all programmed times and set time of day to zero.
TECHNICAL INFORMATION
Switching Capacity: 16A resistive, 2A
Inductive
Ambient Temperature: -10°C to + 55°C
Running Reserve: 150 hours
Memory Location: 24
Shortest Switching Time: 1 minute
Wattage: 3000W
Conforms To: EN 60730-1:2011,
EN 60730-2-7:2010/C11:2011
GUARANTEE
Your KingShield 7 Day Electronic Socket
Box Timer is guaranteed for 12 months
from the date of purchase.
This does not affect your statutory rights.
CE INFORMATION
ACTION TYPE: IB POLLUTION SITUATION: NORMAL
CLASS 2 INSULATION:
:MICRO-DISCONNECTION LIVE
POLE ONLY
PLEASE KEEP THESE INSTRUCTIONS
SAFE FOR FUTURE REFERENCE
Issue no: 703909
WEST ROAD . HARLOW ESSEX . CM20 2BG . UK
sales@g re en brook.c o. uk
w ww. g reen broo k.c o.uk
Loading...