nstallation/ Operating
I
Instructions for 7 Day
Electronic Socket Box Timer
T105A-C
-
Please read the instructions fully before
attempting installation.
IMPORTANT
This unit should be installed to current
IET wiring regulations if in doubt
consult a qualified electrician.
• Timer must not be mounted on a
flammable surface.
• Ensure that the timer does not come into
contact with any combustible materials
such as towels or bedding.
• Ensure at least a 300mm air space is
allowed around the timer.
INSTALLATION
• Prepare cable ends for connection to
terminals.
• Remove the 2 screws holding the
timeswitch cover to the backplate.
Remove cover leaving the timeswitch
hanging loose by its connection wires
to the backplate. DO NOT INTERFERE
WITH THESE FIXED CONNECTIONS.
WIRING
• Connect all earth wires to earthing point in
wall box.
• Offer up the backplate to the wall box and
connect the wiring as shown in diagram
below.
IMPORTANT:
Ensure all Terminal screws are fully tightened.
• When the wiring is complete screw the
backplate to the fitted wall box using 3.5mm
screws.
• Push the timeswitch back in to its seating
on the backplate, taking care that all the
wires are tucked in. Fit the cover and tighten
the two screws.
CURRENT TIME AND
DAY SETTING
1. Press the R button to reset the timer to its
default settings, activate using a pencil or
simular pointed instrument. (pressing R
will delete all stored programmes).
. Press Y to enter function setup. (Note:
2
if another button is not pressed within 10
seconds the display will revert to the
normal screen).
. Use the + or - button to scroll to the clock
3
icon (flashing) and press Y to enter the
current time setting mode (hours
flashing).
4. If you keep the + or - buttons pressed for
more than 3 seconds, the display will enter
fast scroll mode.
5. Use the + or - button to adjust the hours
nd press Y to confirm, minutes will flash.
a
6. Use the + or - button to adjust the
minutes and press Y to confirm, day will
flash.
7. Use the + or - button to adjust the day and
press N to exit.
PROGRAMMING THE
SWITCHING TIMES
1. There are 24 ON/OFF programmes
available.
2. Press the Y button twice to enter the
programming setting mode.(Note: if
another button is not pressed within 10
seconds the display will revert to the
normal screen).
3. Default is programme 01 ON, this can be
changed if required by pressing + or -
button to scroll through the 24 ON/OFF
programmes as required, pressing the Y
will confirm the programme.
4. Press the Y button to confirm programme
01 ON, hours will flash.
5. Use the + or - button to adjust the hours
and press Y to confirm, minutes will flash.
6. Use the + or - button to adjust the minutes
and press Y to confirm, days will flash.
7. Apart from individual days of the week,
the following day combinations of
multiple day blocks can be selected by
pressing the + or - buttons.
• Monday to Sunday
• Monday to Friday
• Saturday to Sunday
• Monday to Saturday
• Monday + Wednesday + Friday
• Tuesday + Thursday + Saturday
• Monday + Tuesday + Wednesday
• Thursday + Friday + Saturday
8. Select day or day block as required and
press the Y button to confirm.
9. Press the + button, this will select the
programme 01 OFF, press Y to confirm.
10.Follow 4 to 7 above to set the 01 OFF
programme (day or day block must be the
same as programme ON).
11.If no more programmes are required, press
the N button to exit.
12.If more programmes are required follow
3 above.

13.To cancel a programme once set, press
and hold the N button for more than 3
seconds when the desired programme
umber is flashing i.e. to cancel
n
programme 01 ON, press the Y button
twice and hold the N button down for
ore than 3 seconds to delete. Pressing
m
the + button again will select 01 OFF.
14.Repeat 13 to delete 01 OFF. This
procedure can be repeated to delete any
of the 24 programmes.
TIMER COUNTDOWN
FUNCTION
1. Timer has a 100 hour countdown feature
i.e. the timer can be set to any period from
1 minute to 100 hours and will countdown
in the ON state and turn OFF at the end of
the countdown period.
2. Press the Y button then use the + or button to select the “down” icon on the
right hand side of the display, press Y
again to enter the countdown mode.
3. Use the + or - button to adjust the hours
and press Y to confirm. minutes will flash.
4. Use the + or - button to adjust the minutes
and press Y to confirm and complete the
countdown time setting.
5. Press the N button to start the countdown.
6. Output switched to ON during the
countdown period.
7. Press the N button to pause the
countdown (output switched to OFF)
8. To resume countdown simply press the N
button again.
9. Press and hold the N button for more than
3 seconds to exit the countdown function.
MANUAL OVERRIDE
1. When in normal clock mode, pressing
the N button will scroll through the
following switching options.
• ALWAYS ON - timer is permanently ON.
• PROG - timer is in programme ON
mode, will switch off at the next
programme OFF time.
• ALWAYS OFF - timer is permanently OFF.
• PROG - timer is in programme OFF
mode, will switch on at the next
programme ON time.
SUMMER TIME SETTING
1. Press the Y button, then use the + or buttons to scroll through to “summer”
(flashing).
2. Press the Y button again to access the
summer time setting.
3. Press the + or - button to change between
summer on or off.
4. Press Y to confirm summer setting, time
will advance 1 hour.
5. A “SUMMER” icon will appear in the
display.
6. Use the same procedure to remove the
“SUMMER” icon when reverting to GMT
in the winter.
RANDOM SETTING
The random setting allows the timer to switch
ON and OFF with a random delay of between
2 and 32 minutes. This function will only
operate if one or more programmes have
been programmed into the timer.
1. Press the Y button, then use the + or buttons to scroll through to “RANDOM”
(flashing).
2. Press the Y button again to access the
random setting.
3. Pressing the + or - buttons will toggle the
random icon on and off.
4. Press the Y button to confirm random
function.
5. A “RANDOM” function icon will appear in
the display.
6. Timer will now operate in the random
mode.
7. To cancel random feature use the
procedure above to remove the
“RANDOM” icon from the display.
READING YOUR
PROGRAMMED TIMES
1. Press Y button twice to enter programme
mode.
2. Press the + or - buttons to scroll through
the 24 ON/OFF programmes to check
settings.
3. Press the N button to exit and revert to
clock mode.
RESET
Pressing the reset button R with a pencil or
similar will reset all programmed times and
set time of day to zero.
TECHNICAL INFORMATION
Switching Capacity: 16A resistive, 2A
Inductive
Ambient Temperature: -10°C to + 55°C
Running Reserve: 150 hours
Memory Location: 24
Shortest Switching Time: 1 minute
Wattage: 3000W
Conforms To: EN 60730-1:2011,
EN 60730-2-7:2010/C11:2011
GUARANTEE
Your KingShield 7 Day Electronic Socket
Box Timer is guaranteed for 12 months
from the date of purchase.
This does not affect your statutory rights.
CE INFORMATION
ACTION TYPE: IB
POLLUTION SITUATION: NORMAL
CLASS 2 INSULATION:
:MICRO-DISCONNECTION LIVE
POLE ONLY
PLEASE KEEP THESE INSTRUCTIONS
SAFE FOR FUTURE REFERENCE
Issue no: 703909
WEST ROAD . HARLOW
ESSEX . CM20 2BG . UK
sales@g re en brook.c o. uk
w ww. g reen broo k.c o.uk