GreenBrook T104A-C Installation Instructions

Installation/ Operating Instructions
for 7 Day Mechanical Immersion
eater Timer
H
- T104A-C
Please read the instructions fully before
ttempting installation.
a
MPORTANT
I
his unit should be installed to current
T
IET wiring regulations if in doubt
• Timer must not be mounted on a flammable surface.
• Ensure that the timer does not come into contact with any combustible materials such as towels or bedding.
• Ensure at least a 300mm air space is allowed around the timer.
Prepare cables for connection to the
imer, (see Diagram A).
t
he maximum size cable that can be
T used with this timer is 2.5mm. If flat
win and earth cable is used the bare
t earth cable must be fitted with
reen/yellow sleeving before fitting
g the earth terminal.
Fit the bare wire ends into the correct
erminals (see diagram B). You must
t ensure that there are no loose strands
eft out of the terminals.
l
Firmly tighten all the screws.
Using the cable clamps and screws provided and ensuring the cable clamp is fitted the correct way round, tightly secure the cable into position.
Ensure the correct cable cut-outs have been removed in terminal cover “D” and refit terminal cover “D ” and tighten screw “C”.
N.B. Check all terminal screws are tight.
THIS TIMER SHOULD NOT BE
FITTED ONTO A CONDUCTIVE
SURFACE (I.E METAL)
FIXING THE TIMER
TO THE WALL
Drill two 6mm holes 97mm vertically apart in the wall. Insert plastic anchor
(supplied) into holes and fit one No.6 screw to top hole leaving a gap under
the screw head of approximately 4.75mm. Place the keyhole slot over the screw and slide the timer down; if the timer is loose remove it, tighten the screw and refit the timer. Continue to do this until the timer fits securely against the wall. Remove terminal cover “D” by undoing screw
“C”. lnsert the second No.6 screw into slot “B ” and tighten. Your timer is now ready for wiring.
Diagram A
Black or Blue
Green or yellow
Red or Brown
C
D
B
WIRING THE TIMER
Your GreenBrook timer should be wired from a fused spur. We recommend a
PowerBreaker H92 RCD model.
Switch off the mains and isolate
the supply by removing the appropriate
fuse before starting the installation.
Diagram B
From mains
L = Red or Brown N = Black or Blue
= Green or Yellow
To appliance
SETTING THE CLOCK
Turn the dial “A”(by turning with finger and thumb) in the direction of the arrow (clockwise) until the correct time of day is exactly opposite the time set marker in centre of the dial.
SETTING THE PROGRAMMES
To set the ON periods push all the sliding segments away from the centre
f dial, between your chosen on and
o off time. The timer will operate during the coloured section now exposed. Each slide
represents 2 hours. The timer will be in the OFF mode when the sliding segments are pushed towards the centre.
When switch is pushed towards:
= timer will be permanently ON
I
= in the centre of the slot. The timer will work to the set programme.
O
= timer will be permanently OFF.
TECHNICAL INFORMATION
Switching Capacity: 230V AC,16A
Ambient Temperature: -10°C to + 55°C Shortest Switching Time: 2 hours Wattage: 3000W Conforms To: EN 60730-1:2011,
resistive,2A Inductive
EN 60730-2-7:2010/ C11:2011
GUARANTEE
Your KingShield 7 Day Mechanical
Immersion Heater Timer is guaranteed for 12 months from the date of purchase. This does not affect your statutory rights.
CE INFORMATION
ACTION TYPE: IB POLLUTION SITUATION: NORMAL
:MICRO-DISCONNECTION LIVE
POLE ONLY
PLEASE KEEP THESE INSTRUCTIONS
SAFE FOR FUTURE REFERENCE
WEST ROAD . HARLOW ESSEX . CM20 2BG . UK
sal es@ gre enb ro ok.c o.u k
w w w. gr e e n b r o o k. co.u k
Issue no: 703917
Loading...