IMPORTANT – FOR YOUR
PROTECTION.
Electricity is dangerous and
an RCD must not be used as
a substitute for normal
precautionary measures.
Always unplug from mains
supply before any inspection
or repair to equipment. Do
not allow children to tamper
with electrical devices.
This device will protect
against live and neutral
leakage faults to earth, it will
not protect against electric
shock due to contact with
both conductors, short
circuits between live and
neutral, or a fault in the
wiring supplying this device.
TO FIT THIS
POWERBREAKER SAFETY
RCD SOCKET –
Switch off the power supply
at the mains. Fit metal back
box then simply connect
using the easy to follow
wiring diagram.
Note: Metal back box should
be earthed.
Safety RCD Socket Operating Instructions
around White button will
turn Red and illuminate*.
3. Press Grey Test button (T).
4. Red window indicator and
illumination will
disappear*. This means
the RCD has tripped
successfully.
5. To reset – press White ON
button and use as a
normal socket.
* If indicator fails to work,
do not use and return to
place of purchase.
NOTE 1:
If the red window indicator
disappears once the socket
has been reset and appliance
is firmly plugged in the
socket, this may mean that
the appliance or the cable
lead is faulty, and should be
checked by a qualified
electrician.
NOTE 2:
Remove this RCD from
circuit before performing any
high voltage insulation tests.
Blue or
Black (N)
M
ains
Supply
B
rown 0r
Red (L)
Green/Yellow (E)
If earth conductors are bare,
they must be sleeved with
appropriate green/yellow
sleeving.
If you are in any doubt about
connecting this product
consult a qualified electrician
Wiring insulation tests
should be completed before
setting the PowerBreaker
RCD Socket to avoid
misleading instrument
readings and possible
internal damage to the unit.
PLEASE CARRY OUT THIS
SIMPLE TEST PROCEDURE
PRIOR TO EACH USE.
1. Press White ON button.
2. Clear window indicator
Please keep these instructions safe for future reference