GreenBrook H92MPAAN-C Installation Instructions

Active - 30mA
Safety RCD Fused Spur Operating Instructions
The PowerBreaker Single Gang RCD Fused Spur Unit has been designed for storage and use between -5°C and +40°C, and at an altitude of no greater than 2000m above sea level. Care must be taken not to subject the unit to misuse, such as abnormal pollution by smoke, chemical or flammable fumes, salt laden spray, prolonged periods of high humidity or other abnormal conditions.
ains
M
upply
Green/Yellow
Green/Yellow
IMPORTANT:
OF SUPPLY AND LOAD
S
Brown
r Red
o
r Black
o
Blue or Black
Brown or Red
Load
NOTE POSITION
INSTALLATION.
Note: Metal back box should be earthed.
Install RCD spur and connect wires as shown in diagram. To fit the load/equipment cable remove blanking plug in lower plate. The load cable can now be passed through hole and wired according to diagram. Any bare earth conductors must be sleeved with green/yellow sleeving.
Note: Clamp is reversable to cover wide range of cable diameters.
PLEASE CARRY OUT THIS SIMPLE TEST PROCEDURE AFTER INSTALLATION.
1. Press Blue ON button.
2. Window indicator will
illuminate Red.
3. Press Grey TEST button.
4. Red window indicator and
illumination will disappear. This means that the RCD has tripped successfully.*
5. To reset – press Blue ON button and use as normal spur.
Fit BS1362 fuse in accordance with equipment manufacturers’ specification. Remove this RCD
from circuit before performing any high voltage insulation tests.
*If indicator fails to work, test
fuse, if unit still fails to work do not use and return to place of purchase.
IMPORTANT – FOR YOUR PROTECTION.
Electricity can be dangerous and the use of an RCD should not be regarded as a substitute for basic electrical safety precautions. Always switch off from supply when working on equipment.
This device will protect against live and neutral leakage faults
to earth, it will not protect against electric shock due to contact with both conductors, short circuits between live and neutral, or a fault in the wiring supplying this device. Should your PowerBreaker Safety RCD Fused Spur Unit repeatedly trip with an appliance
connected or fail to trip when tested, in accordance with the instructions, return to place of purchase.
Note: This is an active device and will need resetting in the event of power loss. To reset - Press the Blue ON button.
Please keep these instructions safe for future reference