GreenBrook ADV3000W, ADVT4000W, ADVAG4000W, ADVAG3000W, ADV4000W Installation Instructions

...
nstallation Instructions for:-
I
‘Vela Advance’ Range
-LED 30, 60 & 90 Mins
ire Rated Mains Voltage
F
Dimmable Downlights
art numbers:
P Fixed:- ADV3000W & ADV4000W Anti-glare:- ADVAG3000W & ADVAG4000W Tilt:- ADVT3000W & ADVT4000W
IMPORTANT INFORMATION
It is recommended that luminaires are installed and fitted by a qualified electrician ensuring the installation complies to the current IET wiring regulation.
If replacing existing fitting, please ensure you follow these instructions and the appropriate wiring regulations. This product is designed for connection to a 230V AC Mains supply.
Always switch off mains supply before servicing a fitting. Special attention should be paid for any installations with low ceiling voids. This fitting is compatible with most leading and trailing edge dimmers for best results use a dimmer designed for LED drivers. Please note that many dimmers have a minimum load requirement which may mean multiple units have to be connected for the dimmer to function correctly. Please see GreenBrook website for compatible dimmers ­www.greenbrook.co.uk.
INSTALLATION INSTRUCTIONS
We recommend that a sample hole is cut in some scrap material to familiarise yourself with the installation. Once you are completely satisfied, locate the areas suitable to install these luminaires. Cut a suitable round hole in the ceiling (see cut out size in table overleaf) and ensure there is sufficient space in the ceiling void without infringing on joist, water pipes or electrical cables.
Fit this product as illustrated. Connect this product to a mains 230V supply only. Connect the Brown feed wire to “L”, connect the Blue feed wire to “N”. Driver is class 2 and does NOT require an earth connection. However 2 earth connections are provided on the driver to maintain circuit earth continuity. Ensure there is adequate free air ventilation around the fitting. The nearest illuminated surface must be at least
0.5m distance from the front of the fitting. Do not install this product into new plaster or damp areas.
Stage 1 -
Read instructions and check you have all the tools and accessories to complete installation correctly.
Dia.1
Stage 2 -
These luminaires are suitable for a 30, 60 or 90 minute fire rated ceiling only. Cut a suitable hole (sizes shown in the technical information table overleaf).
Dia.2
Stage 3 -
Press springs back and push luminaire body into aperture. Connect the luminaire to the supplied driver. As shown overleaf.
Dia.3
Dia.4
dditional Bezels:-
A
ixed
F
ADVBEZG Gold ADVBEZMB Matt Black
DVBEZSC Satin Chrome
A
DVBEZPC Polished Chrome
A
Anti-Glare
ADVAGBEZG Gold
DVAGBEZMB Matt Black
A
DVAGBEZSC Satin Chrome
A ADVAGABEZPC Polished Chrome
Tilt
DVTBEZG Gold
A ADVTBEZMB Matt Black ADVTBEZSC Satin Chrome ADVTBEZPC Polished Chrome
TECHNICAL INFORMATION
ated Voltage: 230V~50Hz
R
ircuit Wattage: 9W
C
allast Type: LED driver
B
lass: II
C Current: 200mA
RI: >85
C Beam Angle: 55º
Operating Temperature: -20°C - +40°C
IP Rating: IP65 Life Span: 50,000 hours
ADV3000W
Cut Out: 73mm Colour Temp: 3,000K Luminaire Lumens Output: 820, 90 lm/W
ADVAG3000W
Cut Out: 73mm Colour Temp: 3,000K Luminaire Lumens Output: 670, 73 lm/W
ADVT3000W
Cut Out: 83mm Colour Temp: 3,000K Luminaire Lumens Output: 820, 90 lm/W
ADV4000W
Cut Out: 73mm Colour Temp: 4,000K Luminaire Lumens Output: 850, 92 lm/W
ADVAG4000W
Cut Out: 73mm Colour Temp: 4,000K Luminaire Lumens Output: 690, 77 lm/W
ADVT4000W
Cut Out: 83mm Colour Temp: 4,000K Luminaire Lumens Output: 850, 92 lm/W
Your GreenBrook LED Fire Rated Downlight