SPECIFACTIONS
MCC-1
Product .................................................Micro Climate Controller ( MCC-1 )
Maximum Amperage Capacity .......................................................... 12 Amps
Normal Output ................................................................................... 115 VAC
Warm Up Period ................................................................ less than 5 minutes
Operating Temperature Range ...................................................... 0 to + 50° C
Operating Humidity Range ...................................................... 5% to 95% RH
Thermostat Range ........................................................................ 10° to 110° F
Humidity Range...................................................................... 10% to 90% RH
Power Requirement ........................................................................... 110 VAC
Dimensions (HxWxD) ...................................................................... 9"x12"x3"
Weight .................................................................................................7 Pounds
Repair Service.............................................................. Return to Manufacture
Operating Life Expectancy..................................................... 7 year minimum
Operating Power Requirements ............................ 120 VAC ± 20% 50/60 Hz
Relay................................................................................... Electro Mechanical
Mechanical Operations ..................................................................... 1,000,000
Electrical Operations ........................................................................... 100,000
Switching Capacity ...................................................................... 12 Amp Max
CALL YOUR LOCAL DEALER
G
REEN
PROFESSIONAL GREENHOUSE EQUIPMENT
A
IR
P
RODUCT
MICROCLIMATE CONTROLLER
MCC-1
GREEN AIR PRODUCTS
P.O. BOX 1318
GRESHAM, OR 97030
503-663-2000
INSTRUCTION MANUAL
MICROCLIMATE CONTROLLER
MCC-1
The MicroClimate Controller MCC-1
is designed to perform all the major
atmospheric and timed functions required in an automated growth environment including temperature, humidity, carbon dioxide enrichment, lighting and irrigation control. The controller incorporates an external coil cooling thermostat , a dehumidifying humidistat, a 24-hour clock timer, a photosensor and a repeat cycle timer. Heating
and humidifying control is provided by
triggers for remote high-amperage relays which enable synchronized equipment management. Automatic override
and defeat systems coordinate controls
MCC-1 is enclosed in a black anodized, brush finish aluminum housing. An attractive
screen-printed front panel with function indicator lights makes system monitoring and
adjustment quick and easy. All connections are standard 3-prong grounded plugs and
receptacles. No hard wiring is required for basic operations. Low and high voltage relays
are available to operate auxiliary equipment. Every aspect of the growing environment may
be addressed by the Micro Climate Controller (MCC-1). Operates on 115VAC with 12 Amp
switching capacity. Approved for indoor only.
Intake and/or
Exhaust Fan
Lighting
to consider all possible variables. The
FUNCTION RELAYS
Dry Contact Switches
HAR-1
The HAR-1 is a power relay that uses high
amperage capacity contacts to transfer power
to large fans or lighting systems requiring
high voltage or amperage service. Use to
operate 115 or 240 Volt high draw equipment. 30 Amp switching capacity with 115
Volt trigger.
HR-1
The HR-1 is a high amperage relay with a
built in external coil heating thermostat.
Use to supply 115 or 240 Volt power to
heating equipment when tempeature falls
below set point. 30 Amp switching capacity
for heavy load requirements. A jack
receptical and internal low voltage dry contacts are used to function gas type heaters.
See MCC-1 installation description.
Heating
Temperature
Exhaust
G
REEN
A
IR
P
ATMOSPHERIC SYSTEMS & CONTROLS
Outlet
2
MCC-1
Photo Sensor
CO
2
Timer
OFF
110 V
Outlet
RODUCTS
Cycle
Timer
FREQUENCY
Outlet
Exhaust On
CDDS-1
Trigger
Temperature High
Humidity High
Timed Outlet
CO
Cycle Outlet
HR-1
Heater Relay
Relay
Humidifing Relay
HF-1
Relay
Thermostat Humidistat
Climate Controller
MANUFACTURED BY GREEN AIR PRODUCTS , USA 110VAC 15A MAX
Of "ON" Time
8
7
6
5
Sequence Timer
24 Hour Timer
7m
2
3
On Timed
Outlet
Off Timed
Outlet
CO
2
DURATION
Outlet
Of "ON" Time
30
15m
5s23
Cycle
15
21
1
Timer
515
17
3.5m
Outlet
10
CO
Equipment
2
or
Irrigation
HF-1
Thie HF-1 is a high amperage relay with a
built in humidifying humidistat. Use to
supply 115 or 240 Volt power to humidify-
Pumps
or
Solenoid Valves
ing equipment when humidity falls below set
point. 30 Amp switching capacity for heavy
load requirements.