Green Air Products CST-1 P User Manual

TIMED EXHAUST WITH CO2 DEFEAT
G
REEN
A
IR
P
RODUCTS
ATMOSPHERIC SYSTEMS & CONTROLS
CST-1P
7m
8
HOURS MINUTES
30
15m
7
6
2
5
3
OUTLET OUTLET
5s
23
15
1
21
515
ON
17
3.5m
10
DURATIONFREQUENCY
Here we have a timed intake / exhaust cycle with synchronized CO2 func­tions. CO2 equipment operates according to schedule set on CST-1P . Room air changes are registered according to CST-1 set points. CO2 is replen­ished immediately after exhaust functions and defeated during darkness periods. Reverse CST timers to defeat both CO2 and exhaust functions when light is not present.
G
REEN
A
IR
P
RODUCTS
ATMOSPHERIC SYSTEMS & CONTROLS
CST-1
7m
8
HOURS MINUTES
30
15m
7
23
1
6
OUTLET OUTLET
21
515
ON
17
3.5m
2
5
10
3
DURATIONFREQUENCY
5s
15
CHRONOMETRIC SEQUENCE TIMER
TWO YEAR LIMITED WARRANTY
Green Air Products guarantees that this equipment will perform as implied for the purpose it is intended. Green Air Products warrants the original purchaser of this equipment against defects in mechanical parts and workmanship for 2 years and electrical parts for 90 days. At our option we will repair or replace defective equipment. Warranty service is only performed at the factory or authorized service center. Any usage contrary to proper application or alterations of original con­struction will void warranty obligations. For further warranty information con­tact your dealer or Green Air Products service department.
1-503-663-2000
GREEN AIR PRODUCTS INC.
P.O. BOX 1318 GRESHAM, OREGON
97030 U.S.A. 503-663-2000
CST-1 &
CST-1 P
INSTRUCTION MANUAL
CHRONOMETRIC SEQUENCE TIMER
CST-1(P)
The CST-1 has solved the age old problem of accurate short cycle tim­ing. The only unit of it’s kind designed specifically for the control of grow systems. Easy to set and operate. Solid state time counter with adjustable frequency and duration. The CST-1 function timer has many uses you will notice as you look thru this manual. Only a few of them include: fogging or misting, spray stakes or drip system timing, air pumps, CO2 equipment and intake \ exhaust fan control. A vailable with or with­out photo sensor feature.
G
REEN
A
IR
P
Long Cycle
Outlets
ATMOSPHERIC SYSTEMS & CONTROLS
CHRONOMETRIC SEQUENCE TIMER
CST-1
8
7
6
MANUFACTURED BY GREEN AIR PRODUCTS , USA 110VAC 10A MAX
7m
HOURS MINUTES
15m
1
3
Of "ON" Time
2
5
FREQUENCY
30
23
ON
RODUCTS
21
515
17
10
DURATION
Of "ON" Time
3.5m
5s
15
Short Cycle
Outlets
INSTALLA TION E XAMPLE
G
REEN
A
IR
P
RODUCTS
ATMOSPHERIC SYSTEMS & CONTROLS
CHRONOMETRIC SEQUENCE TIMER
CST-1
7m
8
HOURS MINUTES
30
15m
7
6
OUTLET OUTLET
MANUFACTURED BY GREEN AIR PRODUCTS , USA 110VAC 10A MAX
The diagram above shows how to install the CST-1 to supply nutrient to a grow system. The CST-1 may be plugged directly into a standard 110 VAC wall outlet or into another Green Air Products Timer or Atmospheric Controller. When plugged into the wall, as in the example above, the CST-1 will perform the same timed operations indefinitely. The main nutrient pump is plugged into the short cycle ( right ) side of the CST-1. Nutrient is scheduled to the grow system and drains into catchment tank or directly back into the main tank. The CST-1 is ideal for spray stakes,
drip emitters, ebb and flow or sprinklers.
5s1023
15
1
21
515
ON
17
3.5m
2
5
3
DURATION
FREQUENCY
Of "ON" Time
Of "ON" Time
HOW TO OPERATE
The CST-1S may be set for frequency and duration of timed events. Frequency is the time between the “On” and "Off" cycles. The fre­quency knob may be set from 7 minutes to 8 hours. Set this for desired time between functions. Duration is the length of time that a specific function or condition must be maintained. Duration may be set from 5 seconds to 30 minutes. Reset feature allows function synchronizing with other system controls. Right side of timer operates short cycle “On” times and left side outlets are “On” when right side is “Off”. This feature provides an interesting variety of timing combinations. Oper­ates on 110 VAC with 15 Amp switching capacity.
G
REEN
A
IR
P
RODUCTS
ATMOSPHERIC SYSTEMS & CONTROLS
CST-1P
7m
8
HOURS MINUTES
30
15m
7
1
21
6
OUTLET OUTLET
515
ON
17
2
5
3
DURATIONFREQUENCY
5s1023
15
3.5m
G
REEN
A
IR
ATMOSPHERIC SYSTEMS & CONTROLS
AtmosphericController
70 70
80
60
CT-DH-3
90
50
100
40
110
30
20
10
P
RODUCTS
80
OFF
ON
20
60
50
40
30
This example shows the CST-1P being used to time CO2 production. CO2 equipment is defeated during exhaust functions and immediately replenished upon completion. Photo sensor permits CO2 enrichment dur­ing day light periods only.
Loading...