GreeenTek Whole House HS 3.0 Installation, Maintenance And Operation Manual

INSTALLATION / MAINTENANCE / OPERATION
GUIDE
WHOLE HOUSE HEPA FILTRATION SYSTEMS
MODEL HS 3.0
Table of contents
PAGE
2
1.2 Technical data 3
2.1 Planning the installation 4
2.2 Type of installation: Return to Return 4
2.3 Type of installation: Stand-Alone 5
2.4 Installing the unit 6
3.1 General Operating Information 9
4.1 Changing filters 10
4.2 Cleaning unit 10
INFORMATION FOR INSTALLERS PAGE
2.Installation Guide
INFORMATION FOR THE HOMEOWNER PAGE
3.Owner’s Operation Guide
GENERAL MAINTENANCE INFORMATION PAGE
4. Maintenance Guide
1.1.Unpacking and inspection
Box Content
Includes:
• Whole House HS 3.0
• Power cord, 5 FT
• Plenum seal, 7.5 FT
• Screws, (16) 8 x 32 x 1/2”
• Template
GENERAL INFORMATION PAGE
1.Getting Started
About Us
Imperial Air Technologies Inc. is the only manufactur­er that offers you a complete range of products designed to improve indoor air quality, and that provides a wide selection of accessories to facilitate installation.
Our vision – To offer a complete range of Greentek
TM
products that satisfy environmental concerns.
Whether your needs involve ventilation, purification, humidification or filtration, GreentekTMhas the customized solution for you, with its range of quality products backed by the best warranty in the industry.
Greentek
TM
Peace of Mind
Limited
WARRANTY
All GreentekTMproducts are backed by the best limited warranty in the industry, for your peace of mind.
You benefit from a 10 year warranty (5 years + 5 years prorated) on our motorized impeller and a 5 year warranty on other components including: unit’s casing, motor bracket and collars.
So you can breathe easy.
1.2. Technical Data
PAGE
3
Dimensions and Clearance
installation
Back View
Front View Side View - Clearance
Side View
Front View
Side View - Clearance
Return Air Plenum and Stand Alone Installations
*
With Collar Mount Kit
IMPORTANT INFORMATION
Imperial Air Technologies, Inc.reserves the right to modify a product, without prior notice, whether in design, color or specifications, in order to offer at all times a quality product that is highly competitive. • Please consult local authorities to find out whether the installation of electrical products requires the services of a certified technician or electrician.
22” (559 mm)
13”
(330mm)
17”
(432 mm)
17”
(432mm)
17”
(432 mm)
12”
(305 mm)
11.587”
(294.5 mm)
Return Air Plenum Installation
12”
(305 mm)
11.587”
(294.5 mm)
22” (559 mm)
* Installation requires kit No.100608
Stage 1
Stage 3
Stage 2
Stage 1
Stage 3
Stage 2
Specifications
Model HP500
Filtration Stage 1 Prefilter (100511) Filtration Stage 2 Carbon Filter (100512) Filtration Stage 3 HEPA filter (100510) Weight 28 lbs (12.7 kg) Plenum Mount Port Openings 16” x 3.5” (406mm x89mm) Collar Mount Port Openings 8” (203mm) Round* Installation type Plenum,Wall* or Floor*Mounted Electrical Supply 120 VAC @ 60 Hz Power Consumption 134 W Certification
C
CSA
US
Air flow data 220-300 CF.M.
Return
Air Plenum
Forced Air Heating/Cooling System
Forced Air Heating/Cooling System
To living space
PAGE
4
Special Consideration
For integrated system installation
•Verify clearance on the ductwork to mount the unit using the Forced Air heating/cooling system
• Minimum clearance requirements for maintenance and service
• Electrical power requirements
• Interaction between the HEPA filter unit and other mechanical devices.
Ducting Flair System
installation
The Whole House HEPA Filtration system is designed to install directly onto the return air plenum of the forced air heating/cooling system. Choosing this type of installation eliminates the need to externally duct the HEPA filter unit to the plenum system. If you choose this type of installation, it is recommended that you run the fan on your forced air system continuously to maximize its cleaning ability.
TIPS
to installer
The Whole House HEPA Filtration system does not replace the filter from the forced air heating/cooling system. Regular maintenance of this filter is necessary to permit the good operation of the forced air heating/cooling system.
Optional collar system
installation
Using kit no. 100608 the Whole House HEPA Filtration system can be converted to use 8 inch round collars for application requiring ducting. The kit includes two, 8 inch round collars, two mounting brackets for wall or floor mounting, installation guide and fas­teners.
2.2
Type of Installation: Return to Return Integrated System
2.1 Planning the Installation
The Whole House HEPA unit is a versatile appliance with multiple installations configuration. It is recommended to take your time in planning the installation.
Several Installations are illustrated herein’ for Whole House filtration applications:
•Return to return integrated with the forced air heating/cooling system.
• Central draw points using dedicated duct system
•Consult the manufacturer for other special applications.
Ducting Flair System
(Hepa Mounted on Duct)
INSTALLATION SHOULD BE PERFORMED BY A CERTIFIED PROFESSIONAL.
Consult your HVAC product manufacturer if the usage of this product will affect the performance of your forced air heating / cooling system.
Optional Collar System
(Hepa Mounted on Wall)
Return
Air Plenum
To living space
Installation GUIDE
2. Information for the Installer