Gree Electric Appliances of Zhuhai CS532U User Manual

Matching instructions
Specialties note
Matching of remote controller
Please do the following operation within 2m from the unit. Matching is not needed anymore once it is done.
During matching, please keep the remote controller and air conditioner under standby status. When the signal of remote controller can’t be received, please match the remote controller with the unit again.
This model adopts RF remote control. The remote controller shall be matched with the air conditioner before operation, otherwise the remote control will be invalid. Before operation, please read the instructions in this page carefully and then do the corresponding matching operation.
Note
When the unit is under standby status, please get close to the air conditioner within 2m and then hold on pressing button for 3s. The remote controller and air conditioner will enter matching automatically. If matching is done, the unit will give out three sounds; if matching is failed, please get closer to the unit and arrange matching again.
Humidify/Health
Explanation of Symbols
Indicates a hazardous situation that, if not avoided, will result in death or serious injury.
Indicates a hazardous situation that, if not avoided, could result in death or serious injury.
Indicates a hazardous situation that, if not avoided, may result in minor or moderate injury.
Indicates important but not hazard-related information, used to indicate risk of property damage.
Indicates a hazard that would be assigned a signal word WARNING or CAUTION.
1
Precautions
WARNING
Do not connect air conditioner to multi-purpose socket.
This appliance is not intended for use by persons (incl-
Operation and Maintenance
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Do not spray water on indoor unit. It may cause electric shock or malfunction.
Otherwise, it may cause fire hazard.
Children shall not play with the appliance. Cleaning and user maintenance shall not be made by
children without supervision.
uding children) with reduced physical, sensory or men­tal capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person respon­sible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Do not wash the air conditioner with water to avoid electric shock.
After removing the filter, do not touch fins to avoid injury. Do not use fire or hair dryer to dry the filter to avoid
deformation or fire hazard.
Do disconnect power supply when cleaning air conditioner. Otherwise, it may cause electric shock.
Do not block air outlet or air inlet. It may cause malfunction.
remote controller may be broken.
Power cord is overheating or damaged.
There’s abnormal sound during operation.
Circuit break trips off frequently.
Air conditioner gives off burning smell.
Indoor unit is leaking.
contact the dealer or qualified professionals for service.
When turning on or turning off the unit by emergency operation switch, please press this switch with an insulating object other than metal.
outlet. It may cause personal injury or damage.
Precautions
WARNING
conditioner and disconnect power immediately, and then
If the air conditioner operates under abnormal conditions, it may cause malfunction, electric shock or fire hazard.
Do not spill water on the remote controller, otherwise the
electric shock or damage. Please contact dealer when you need to repair air conditioner.
Do not repair air conditioner by yourself. It may cause
objects. It may cause damage or personal injury.
Do not step on top panel of outdoor unit, or put heavy
When below phenomenon occurs, please turn off air
Do not extend fingers or objects into air inlet or air
Maintenance must be performed by qualified professionals. Otherwise, it may cause personal injury
or damage.
2
Do install the circuit break. If not, it may cause malfunction.
of at least 3mm in all poles should be connected in fixed wiring.
magnet buckle
and heating buckle function, it can protect
the circuit-short and
overload.
power supply circuit and circuit break.
Precautions
WARNING
note
the following table.Air switch should be included
Make sure the power supply matches with the requirement of air conditioner.Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
An all-pole disconnection switch having a contact separation
Must follow the electric safety regulations when installing the unit.
grounding wire of power socket.
Properly connect the live wire, neutral wire and
any work related to electricity and safety.
Be sure to cut off the power supply before proceeding
Including an circuit break with suitable capacity, please
Air Conditioner should be properly grounded. Incorrect
Don't use unqualified power cord.
grounding may cause electric shock.
According to the local safety regulations, use qualified
Installation must be performed by qualified professionals. Otherwise, it may cause personal injury or damage.
Attachment
3
Installation must be performed in accordance with the
persons in order to avoid a hazard.
must be properly grounding with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock.
The appliance must be positioned so that the plug is accessible.
If the length of power connection wire is insufficient, please contact the supplier for a new one. Avoid extending the wire by yourself.
All wires of indoor unit and outdoor unit should be connected by a professional.
national wiring regulations.
requirement of NEC and CEC by authorized personnel only.
Precautions
WARNING
wire, which can't be used for other purposes.
The grounding resistance should comply with national electric safety regulations.
The air conditioner is the first class electric appliance. It
keep the interconnection cable away from the copper tube.
The temperature of refrigerant circuit will be high, please
the manufacturer, its service agent or similarly qualified
If the supply cord is damaged, it must be replaced by
The yellow-green wire in air conditioner is grounding
The appliance shall be installed in accordance with
Do not put through the power before finishing installation.
4
The indoor unit should be installed close to the wall.
reachable after finishing installation.
far away from animals or plants.If it is unavoidable, please add the fence for safety purpose.
Precautions
WARNING
FCC WARNING
place, only the qualified person can perform the work. Otherwise, it may cause personal injury or damage.
If you need to relocate the air conditioner to another
must be installed in the line.
For the air conditioner without plug, an circuit break
Select a location which is out of reach for children and
For the air conditioner with plug, the plug should be
5
Instructions for installation and use of this product are provided by the manufacturer.
expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
WARNING: Changes or modifications to this unit not
FCC STATEMENT
Operation is subject to the following two conditions :
This device complies with Part 15 of the FCC Rules.
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
equipment generates, uses and can radiate radio
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and
receiver.
Connect the equipment into an outlet on a circuit
Consult the dealer or an experienced radio/TV
different from that to which the receiver is connected.
technician for help.
interference to radio communications.
comply with the limits for a Class B digital device,
Precautions
FCC STATEMENT
accordance with the instructions,may cause harmful
harmful interference in a residential installation. This
undesired operation.
frequency energy and, if not installed and used in
However, there is no guarantee that interference will
does cause harmful interference to radio or television
correct the interference by one or more of the following measures:
equipment off and on, the user is encouraged to try to
not occur in a particular installation. If this equipment
reception, which can be determined by turning the
NOTE: This equipment has been tested and found to
(1) this device may not cause harmful interference, and (2) this device must accept any interference received,including interference that may cause
6
Precautions
Le présent appareil est conforme aux CNR d'Industrie
licence. L'exploitation est autorisée aux deux conditions
tout brouillage radioélectrique subi, même si le
undesired operation of the device.
IC STATEMENT
brouillage, et (2) l'utilisateur de l'appareil doit accepter
Canada applicables aux appareils radio exempts de
interference, and (2) this device must accept any
suivantes : (1) l'appareil ne doit pas produire de
brouillage est susceptible d'en compromettre le fonctionnement.
interference, including interference that may cause
This device complies with Industry Canada licence-
This equipment complies with FCC’s and IC’s RF radiation exposure limits set forth for an uncontrolled environment. The antenna(s) used for this transmitter must be installed and operated to provide a separation distance of at least 20 cm from all persons and must
exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause
not be collocated or operating in conjunction with any other antenna or transmitter. Installers must ensure that 20cm separation distance will be maintained between the device (excluding its handset) and users.
Cet appareil est conforme aux limites d’exposition au rayonnement RF stipulées par la FCC et l’IC pour une utilisation dans un environnement non contrôlé. Les
7
Precautions
Working temperature range
Indoor side DB/WB(ć) Outdoor side DB/WB(ć)
Maximum cooling 26.7/19.4 46.1/23.9
Maximum heating 26.7/- 23.9/18.3
The operating temperature range (outdoor temperature) for cooling only unit is
-18
ć
~54ć; for heat pump unit is -30
ć
~ 54ć.
NOTICE:
IC STATEMENT
près d’autres antennes ou émetteurs ou fonctionner
antennes utilisées pour cet émetteur doivent être installées et doivent fonctionner à au moins 20
cm de
distance des utilisateurs et ne doivent pas être placées
distance de 20 cm sépare l’appareil (à l’exception du combiné) des utilisateurs.
avec ceux-ci. Les installateurs doivent s’assurer qu’une
8
Loading...
+ 23 hidden pages