Gree VIR18HP230V1B User Manual

Innovative Ductless solutions
Submittal Data: VIR18HP230V1B 18,000 BTU/H (208/230V) Wall Mounted Heat Pump System
Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No.
GENERAL FEATURES
-High Efficiency DC Inverter Technology
-Wireless Remote with LCD Display
-Wi-Fi Ready ( Sold Separately Kit PN: WSBEC02)
-XK-41 Wired Tether Controller ( Sold Separately)
-Low Ambient Cool to 0 deg F
-Blue Fin Condenser Coil
-5 year Limited Parts Warranty
Cooling
Fan Motor
Type Cross-Flow
Rated Capacity 18,000 BTU/H Output Power 60 W
Capacity Range 6,800-20,000 BTU/H FLA 0.24 A
Power Input (Max) 2,600 W
Airflow
SEER 20.0
Cooling Wet (Lo/Hi)
335/559 CFM
EER 12.5
Heating Dry (Lo/Hi)
335/559 CFM
Heating at 47° F
Rated Capacity 19,800 BTU/H Sound Pressure Level
Capacity Range 7,340-23,500 BTU/H
Cooling (Min/Max)
39/47 db(A)
Power Input (Max) 2,600 W
Heating (Min/Max)
39/47 db(A)
HSPF 10.5
COP 4.7 Dehumidification 3.80 pt/hr
Heating at 17° F
Rated Capacity 12,400 BTU/H
Compressor Type DC Inverter Driven Rotary
Operating Range
RLA 12.1 A
Cooling (Max)
115℉ (46 C)
(Min)
0 (-18 C) Refrigerant Type R410A
Heating (Max)
75℉ (24 C) Fan Motor Output Power 60 W
(Min)
-4℉ (-20 C) FLA 0.49 A
Gas Pipe Size (OD) 5/8-in Sound Pressure
Liquid Pipe Size (OD) 1/4-in Cooling/Heating 55/55 db(A)
Connection Method Flared
Factory Charge 56.4 oz Power Supply
Additional Charge 0.54 oz/ft
Normal Operational Voltage
208/230 V, 1 Phase, 60 Hz
Pre-Charge Length 25-ft
Voltage Range
187 - 253 V
MAX Refrigerant Pipe Length 82-ft
MCA
16.0 A
MIN Refrigerant Pipe Length 10-ft
MOCP/Breaker Size
25 A
MAX Refrigerant Pipe Elevation 33-ft
Main Power Wire Size
10-2 AWG
Outdoor Unit Data
Indoor Unit Data
System Ratings
Refrigerant Piping Data
Electrical Data
AHRI Certified Ref No: 9956332
Reference
Approval
Construction
Features & Function Summary VIR18HP230V1B
SYSTEM FEATURES
Inverter Type G10 Ultra Low Frequency Torque Control Yes Power Factor Correction Yes Compressor Type High Eff. Rotary Refrigerant Type R410A Basepan With Electric Heater
YES
Compressor With Electric Heater
YES
Outdoor Fin Coating Bule Fin Intelligent Defrosting YES Intelligent Preheating YES Low Voltage Startup YES Memory/Power Failure Recovery YES Self Diagnosis YES Wired Controller Interface (XK-41) YES Wi-Fi Interface Capable
Optional ( see PN: WSBEC01) Indoor Fan Type Crossflow Multi Fan Speeds 4 Speeds Indoor Unit Display YES Advance Filter Optional (see Filter Kits) Auxiliary Electrical Heater NO Ventilation (Outdoor Air) NO
REMOTE CONTROLLER FUNCTIONS
Auto Mode YES Auto Fan YES Auto Swing (Horizontal Auto Swing) NO Auto Swing (Vertical Auto Swing) YES Clock on Remote Controller YES Dry Mode YES Dry Anti-Mildew (X-Fan) Mode NO Energy Saving Mode YES Dirty Filter Alert NO I Feel Function YES Lock on Remote Controller YES Quiet Mode NO Room Temperature Display YES Sleep Mode YES 4 Sleep Modes Options NO Timer Mode YES Turbo Mode YES Display On/Off Control YES Freeze Guard Mode YES Display On/Off Control YES Freeze Guard Mode YES
© Gree Corporation 2017