Gree RIO09HP115V1A, RIO12HP115V1A, RIO12HP230V1A, RIO09HP230V1A, RIO18HP230V1A Technical Product Manual

...
RIO
Ductless Mini-Split Heat Pump 9,000– 24,000 BtuH
Technical Product Guide
Compact & Quiet Solution
1.0 PRODUCT OVERVIEW 3
2.0 FEATURES AND BENEFITS 3
3.0 PRODUCT NOMENCLATURE 6
4.0 AHRI CERTIFICATION 6
5.0 SYSTEM FEATURES 7
6.0 USER CONTROL FUNCTIONS 8
7.0 SYSTEM PERFORMANCE 9
8.0 SOUND DATA 12
9.0 ELECTRICAL DATA 13
10.0 MAJOR COMPONETS & WEIGHTS 14
11.0 DIMENSIONAL SPECIFICATIONS 15
12.0 CLEARANCE SPECIFICATIONS 21
13.0 EXTENDED PERFORMANCE RATINGS 22
14.0 ELECTRICAL WIRING 28
15.0 CONDENSATE REMOVAL 29
16.0 PRODUCT LIMITED WARRANTY 30
2
© 2014 Gree Electric Appliance, Inc.
PRODUCT OVERVIEW
Compact, quiet and provides unmatched comfort in any room.
The Gree Rio High-Efficiency Duct-free Mini-Split Heat Pump system is compact, quiet & provides unmatched comfort in any room. This system includes an indoor cabinet, outdoor compressor, wireless remote and remote cradle. Without needi ng duct work, installation is simple, fast & cost effective. In addition The Gree Rio provides quiet comfort & improved efficiency by eliminating heat loss inefficiencies of conventional central air conditioning systems.
FEATURES AND BENEFITS
HIGH EFFICIENCY G-10 INVERTER - The G10 Inverter uses a broad range of variable frequencies to drive the compressor, marking the highest level of inverter control technology available today. Unlike conventional technology that generally regulates room temperature by running at maximum capacity and then shutting off completely, G10 Inverter technology eliminates these harsh starts/stops. This cutting edge functionality results in quicker arrival at desired temperatures and superior maintenance of consistent comfort levels. Hi gher efficiency and significant energy sav ings? Yes, it yields those too.
HEAT PUMP ADVANTAGE – Gree heat pumps, powered by the G10 Inverter, provide the same heating capacity as electric heat, while using as little as 1/3 the electricity.
WHISPER QUIET - Not only is the Rio systems energy efficient, it’s quiet too. Wall mounted units operate with sound levels starting as low as 32 dB(A).
INTELLIGENT DEFROST - The Intelligent Defrost function increases room comfort and saves energy by eliminating unnecessary defrost cycles. In heating mode, the control system monitors the outdoor coil for frost buildup, and the system switches to defrost mode only when frost buildup is actually detected. This avoids unnecessary and wasteful defrosts.
LOW VOLTAGE START UP – Having stable electrical power is not always an option. The Gree system will operate from 170v to 253v (230v model) and 104v to 127v (115v models) which is suitable for unstable power supply areas.
SUBTLE APPEARANCE -Designed for a comfortable fit in virtually any living space. This slim compact cabinet sits inconspicuously on the wall, and blends into most interior designs
3
© 2014 Gree Electric Appliance, Inc.
FEATURES AND BENEFITS (Cont.)
UNIT DISPLAY – Rio wall mounted units have a lar ge easy-to-read display and indicator lights giving instead feedback on room setpoint, operating mode and much more. The display can also be turned off based on your personal preference.
MULTI-SPEED FAN – The indoor fan can run at up to four different speeds (Low, Medium, High or Turbo) for either COOLING or HEATING mode for maximum comfort an d quiet operation.
TIME GUARD - Among the system’s many safeti es is a Time Guard function to prevent rapid cycling of the compressor. A protective five-minute time delay restricts compressor restarts after shutoff.
POWER FAILURE MODE - Power interruptions are no problem. User selections and system parameters are stored in non-volatile memory. These parameters are retained during a power failure. When power is returned, the system will automatically return to the last operating mode.
INTELLIGENT PRE-HEATING - The system guards against the an noying COLD BLOW in heating mode, and constantly monitors the discharge air temperature. It will delay the indoor fan until the indoor coil has warmed up to prevent blowing uncomfortable cool air into the room.
WIRELESS IR REMOTE CONTROLLER - The Gree multi-functional infrared hand held wireless controller is sleek, ergonomically designed, easy to use and has a large backlit LCD display.
MODE BUTTON - The units can be set to five different operating modes: HEAT, COOL, DRY, FAN ONLY and AUTO.
Note: AUTO MODE has fixed setpoints of 68° F heating and 78° F cooling, which are not changeable. The system will automatically select heating or cooling to maintain room temperature within this temperature band.
TIMER MODE – The unit can be programmed to turned ON or OFF after a specific amount time. The time period is adjustable between one half and 24 hours.
SWING LOUVER – The unit has adjustable swing louvers which can be controlled from the wired tether or wireless controllers. Vertical swing louver allows five different vertical (up & down) air discharge directions including Continuous Sweep. Maximize comfort by adjusting the direction of airflow in the room by moving the louvers up or down.
PRIVACY LOCK MODE – Both wired tether and wireless controllers have a Privacy Lock to avert unauthorized access and stop tampering wit h system settings.
SLEEP MODE –The unit will automatically adjust room temperature during sleep time. This slight change in temperature will not affect your comfort level due to the natural effects that sleeping has on the body, but it will save on energy consumption and will lower electric bills.
© 2014 Gree Electric Appliance, Inc.
4
FEATURES AND BENEFITS (Cont.)
FAHRENHEIT ° F / CELSIUS ° C - The wired tether and wireless controllers can be set to display in either °F or °C.
POLYMERIC AIR FILTERS –Two-piece removable polymeric air filters easi ly slide in and out from the front of the indoor unit and are interchangeable. The front panel does not need to be removed to access or change the filters. The filters are washabl e and permanent.
SELF-DIAGNOSIS –With an on-board computer using real-time diagnostics, the Gree system helps to prolong its own life. The automatic diagnosis feature continuously scans for unacceptable o perating conditions or malfunctions. If such conditions occur, the system takes corrective action or stops. Fault codes are shown on the unit display to facilitate easy troubleshooting and repair.
AGENCY LISTINGS - All systems are listed with AHRI (Air conditioning, Heating, and Refrigeration Institute) and are ETL Certified per UL Standards.
5/7 YEAR LIMITED WARRANTY - Enjoy one of the most comprehensive war ranties in the industry. Seven (7) years on compressor and Five (5) years on all parts.
5
© 2014 Gree Electric Appliance, Inc.
NOMENCLATURE
MODEL NUMBER
BRAND
AHRI CERTIFICATION
RIO09HP115V1A
GREE
7077793
GREE
7084752
GREE
7077585
GREE
7077586
GREE
7077587
GREE
7077588
AHRI CERTIFICATION
RIO12HP115V1A RIO09HP230V1A RIO12HP230V1A RIO18HP230V1A RIO24HP230V1A
6
© 2014 Gree Electric Appliance, Inc.
SYSTEM FEATURES
Nominal Cooling Capacity (Btu/H
208/230
V
Heat
Pump
Heat
Pump
Heat
Pump
Heat
Pump
Heat
Pump
Heat
Pump
SYSTEM FEATURES
Auxiliary Electrical Heater
Basepan With Electric Heater
NO
NO
NO
NO
Compressor With Electric Heater
Corrosion Protection
Blue Fin
Blue Fin
Blue Fin
Blue Fin
Blue Fin
Blue Fin
Inverter Type
G10
G10
G10
G10
G10
G10
Intelligent Defrosting
YES
YES
YES
YES
YES
YES
Intelligent Preheating
YES
YES
YES
YES
YES
YES
LED Display Indoor Unit
Low Ambient Cooling
NO
NO
YES
YES
YES
YES
Low Ambient Heating
YES
YES
YES
YES
YES
NO
Low Voltage Startup
YES
YES
YES
YES
YES
YES
Memory/Power Failure Recovery
Multi Fan Speeds
4 Speeds
4 Speeds
4 Speeds
4 Speeds
4 Speeds
4 Speeds
Self-Diagnosis
YES
YES
YES
YES
YES
YES
PhotoCatalytic Filter
NO
NO
NO
NO
NO
NO
Ventilation (Outdoor Air)
Ambient Cooling Operating Range
64~113 F
64~113 F
5~109 F
5~109 F
5~109 F
5~109 F
Ambient Heating Operating Range
5ºF~75ºF
5ºF~75ºF
5ºF~75ºF
5ºF~75ºF
5ºF~75ºF
19~75 F
RIO09HP115V1A
Model
9,000 12,000 9,000 12,000 18,000 24,000
Operating Voltage 115V 115V 208/230V 208/230V 208/230V
System Type
NO NO NO NO NO NO
NO NO
NO NO YES YES NO NO
RIO12HP115V1A
RIO09HP230V1A
RIO12HP230V1A
RIO18HP230V1A
RIO24HP230V1A
YES YES YES YES YES YES
YES YES YES YES YES YES
NO NO NO NO NO NO
7
© 2014 Gree Electric Appliance, Inc.
USER CONTROL FUNCTIONS
Nominal Cooling Capacity (Btu/H
9,000
12,000
9,000
12,000
18,000
24,000
Operating Voltage
115V
115V
208/230V
208/230V
208/230V
208/230V
REMOTE CONTROLLER FUNCTIONS
Auto Mode
YES
YES
YES
YES
YES
YES
Auto Fan
NO
NO
NO
NO
NO
NO
Auto Swing (Horizontal Auto Swing)
NO
NO
NO
NO
NO
NO
Auto Swing (Vertical Auto Swing)
YES
YES
YES
YES
YES
YES
Clock on Remote Controller
NO
NO
NO
NO
NO
NO
Dry Mode
YES
YES
YES
YES
YES
YES
Dry Anti-Mildew (X-Fan) Mode
YES
YES
YES
YES
YES
YES
Energy Saving Mode
NO
NO
NO
NO
NO
NO
Dirty Filter Alert
NO
NO
NO
NO
NO
NO
I Feel Function
NO
NO
NO
NO
NO
NO
Wired Controller Interface
NO
NO
NO
NO
NO
NO
Lock on Remote Controller
YES
YES
YES
YES
YES
YES
Room Temperature Display
YES
YES
YES
YES
YES
YES
Sleep Mode
YES
YES
YES
YES
YES
YES
Multi Sleep Modes Options
NO
NO
NO
NO
NO
NO
Timer Mode
YES
YES
YES
YES
YES
YES
Turbo Mode
YES
YES
YES
YES
YES
YES
Model
RIO09HP115V1A
RIO12HP115V1A
RIO09HP230V1A
RIO12HP230V1A
RIO18HP230V1A
RIO24HP230V1A
8
© 2014 Gree Electric Appliance, Inc.
SYSTEM PERFORMANCE
Outdoor
Operating Range
Rated
(BtuH)
Range
(BtuH)
RIO09HP115V1A
16
12.0
9,000
(3,500-11,000)
64 °F
113 °F
RIO12HP115V1A
16
9.4
11,800
(3,300-12,500)
64 °F
113 °F
RIO09HP230V1A
16
10.2
9,000
(3,800-11,500)
5 °F
109 °F
RIO12HP230V1A
16
9.8
12,000
(3,300-12,500)
5 °F
109 °F
RIO18HP230V1A
16
11.1
18,000
(4,500-21,000)
5 °F
109 °F
RIO24HP230V1A
16
10.0
22,000
(6,400-24,000)
5 °F
109 °F
Outdoor Temperature
Operating Range
RIO09HP115V1A
8.6
3.5
9,800
(2,500-11,000)
5 °F
75 °F
RIO12HP115V1A
8.6
2.9
13,000
(3,400-13,500)
5 °F
75 °F
RIO09HP230V1A
8.5
3.4
9,000
(3,300-11,500)
5 °F
75 °F
RIO12HP230V1A
8.5
3.4
12,000
(3,400-12,500)
5 °F
75 °F
RIO18HP230V1A
2.8
19,200
(4,000-23,000)
5 °F
75 °F
RIO24HP230V1A
3.0
24,200
(4,100-26,600)
19 °F
75 °F
Model Numbers SEER EER
Model Numbers HSPF COP
Cooling Capacity
Heating Capacity
Rated
(BtuH)
Range (BtuH) Min Max
Dehumid-
ification
./Hr.)
(Pts
1.7
2.9
1.7
2.9
3.8
4.2
Temperature
Min Max
8.0
8.5
NOTES:
1. Ratings are based on: Cooling Standard: 80 F (26.7 C) db, 67 F (19.4 C) wb air entering indoor unit and 95 F (35 C) db air entering outdoor unit. Heating Standard: 70 F (21.1 C) db air entering indoor unit and 47 F (8.3 C) db, 43 F (6.1 C) wb air entering outdoor u ni t.
2. Ratings are based on 25 ft. (7.62 m) of interconnecting refrigerant lines.
3. All system ratings are based on fan coil units operating at high fan speed. Consult Physical Data tables for air flows at selected fan speeds.
Legend
EER - Energy Efficiency Ratio HSPF - Heating Seasonal Performance Ratio SEER - Seasonal Energy Efficiency Ratio COP - Coefficient of Performance
9
© 2014 Gree Electric Appliance, Inc.
AIR FLOW PERFORMANCE
Indoor Unit
Cooling (CFM)
Fan
Fan
Fan
Fan
RIO09HP115V1AH
188
223
276
329
188
223
276
329
RIO12HP115V1AH
200
235
288
341
200
235
288
341
RIO09HP230V1AH
141
194
282
330
141
194
282
330
RIO12HP230V1AH
153
206
294
341
153
206
294
341
RIO18HP230V1AH
271
330
400
471
271
330
400
471
RIO24HP230V1AH
206
306
441
589
206
306
441
589
Outdoor Unit
RIO09HP115V1AO
1057
RIO12HP115V1AO
1057
RIO09HP230V1AO
942
RIO12HP230V1AO
942
RIO18HP230V1AO
1882
RIO24HP230V1AO
1883
Approximate Air Throw (ft.)
Low
Medium
High
Turbo
RIO09HP115V1AH
NA
NA
26
33
RIO12HP115V1AH
NA
NA
26
33
RIO09HP230V1AH
NA
NA
26
33
RIO12HP230V1AH
NA
NA
26
33
RIO18HP230V1AH
NA
NA
21
24
RIO24HP230V1AH
NA
NA
21
31
Model Numbers
Model Numbers Air Flow (CFM)
Low
Medium
High
Turbo
Low
Fan
Heating (CFM)
Medium
Fan
High
Fan
Turbo
Fan
Indoor Air Throw
Model Numbers
10
© 2014 Gree Electric Appliance, Inc.
REFRIGERATION& PIPING SPECIFICATIONS
REFRIGERANT CHARGE
Model Number
Type
Charge (oz.)
Max Total Pipe
Refrigerant (ft.)
Additional
(oz./ft.)
RIO09HP115V1AO
R-410A
37.5
25
0.2
RIO12HP115V1AO
R-410A
41.1
25
0.2
RIO09HP230V1AO
R-410A
26.1
25
0.2
RIO12HP230V1AO
R-410A
35.3
25
0.2
RIO18HP230V1AO
R-410A
45.9
25
0.2
RIO24HP230V1AO
R-410A
54.7
25
0.2
REFRIGERANT PIPING LENGTHS
Model Number
for System (ft.)
System (ft.)
Outdoor & Indoor Units (ft.)
RIO09HP115V1AO
10
66
33
RIO12HP115V1AO
10
66
33
RIO09HP230V1AO
10
50
33
RIO12HP230V1AO
10
50
33
RIO18HP230V1AO
10
82
33
RIO24HP230V1AO
10
82
33
Refrigerant
Factory System
Length Without Adding
Charge Level
Min. Pipe Length
Max Pipe Length for
Max Elevation between
11
© 2014 Gree Electric Appliance, Inc.
SOUND DATA
Indoor High Wall Units
Low Fan
Medium Fan
High Fan
Turbo Fan
Sound
(dBA)
Sound
(dBA)
Sound
(dBA)
Sound
(dBA)
Sound
(dBA)
Sound
(dBA)
Sound
(dBA)
Sound
(dBA)
RIO09HP115V1AH
42
32
45
35
47
37
50
40
RIO12HP115V1AH
42
32
45
35
47
37
50
40
RIO09HP230V1AH
36
26
42
32
48
38
53
43
RIO12HP230V1AH
38
28
43
33
49
39
54
44
RIO18HP230V1AH
44
34
48
38
53
43
58
48
RIO24HP230V1AH
44
34
49
39
53
43
59
49
Outdoor Unit
Sound Power
(dBA)
Sound Pressure
(dBA)
RIO09HP115V1AO
63
53
RIO12HP115V1AO
65
55
RIO09HP230V1AO
59
49
RIO12HP230V1AO
62
52
RIO18HP230V1AO
66
56
RIO24HP230V1AO
63
53
Model Numbers
Model Numbers
Note:
1. Sound pressure ratings are estimated sound pressure measurements, 3 feet from unit.
2. Sound power ratings are per AHRI 270 and AHRI 350
Power
Pressure
Power
Pressure
Power
Pressure
Power
Pressure
12
© 2014 Gree Electric Appliance, Inc.
ELECTRICAL DATA
Rated Power Supply
Cooling
Heating
RIO09HP115V1AO
115v-1ph-60hz
104-127
750
830
RIO12HP115V1AO
115v-1ph-60hz
104-127
1260
1320
RIO09HP230V1AO
208/230v-1ph-60hz
187-253
880
770
RIO12HP230V1AO
208/230v-1ph-60hz
187-253
1620
1050
RIO18HP230V1AO
208/230v-1ph-60hz
187-253
1620
2400
RIO24HP230V1AO
208/230v-1ph-60hz
187-253
2200
2800
Cooling
Heating
RIO09HP115V1AO
9.0
9.5
13
20
RIO12HP115V1AO
15.0
15.5
15
25
RIO09HP230V1AO
3.9
3.4
10
15
RIO12HP230V1AO
5.4
4.7
10
15
RIO18HP230V1AO
7.9
11.8
15
25
RIO24HP230V1AO
11.5
13.0
25
Compressor
Outdoor Fan
Indoor Fan
Input Power
RLA
Input Power
RIO09HP115V1AO
9.8
25.0
0.2
30
0.4
10
RIO12HP115V1AO
11.2
25.0
0.3
30
0.4
10
RIO09HP230V1AO
7.3
16.5
0.3
21
0.2
15
RIO12HP230V1AO
7.3
16.5
0.3
21
0.2
15
RIO18HP230V1AO
10.9
27.0
0.6
60
0.3
20
RIO24HP230V1AO
12.4
41.0
0.6
60
0.4
35
Outdoor Unit
Model Numbers
Outdoor Unit
Model Numbers
(volt-phase-hz)
Rated Input Current (amps)
Voltage Range
(volts)
Rated Input Power (watts)
Min. Circuit
Amp. (MCA)
Max Fuse
Size (Amps)
17
odel Numbers
M
RLA
(amps)
LRA
(amps)
RLA
(amps)
(Watts)
(amps)
Legend:
RLA – Rated Load AmpsFLA – Full Load AmpsLRA – Locked Rotor AmpsMCA – Min. Circuit Amps
(Watts)
13
© 2014 Gree Electric Appliance, Inc.
INDOOR UNIT MAJOR COMPONETS
RIO09HP115V1AH
Polymeric Mesh
AC Sync
Cross flow
RIO12HP115V1AH
Polymeric Mesh
AC Sync
Cross flow
RIO09HP230V1AH
Polymeric Mesh
AC Sync
Cross flow
RIO12HP230V1AH
Polymeric Mesh
AC Sync
Cross flow
RIO18HP230V1AH
Polymeric Mesh
AC Sync
Cross flow
RIO24HP230V1AH
Polymeric Mesh
AC Sync
Cross flow
RIO09HP115VA1O
Rotary
EXV
G10
RIO12HP115VA1O
Rotary
EXV
G10
RIO09HP230VA1O
Rotary
EXV
G10
RIO12HP230VA1O
Rotary
EXV
G10
RIO18HP230VA1O
Rotary
EXV
G10
RIO24HP230VA1O
Rotary
EXV
G10
Outdoor Unit
Indoor Unit
(lbs.)
(lbs.)
(lbs.)
(lbs.)
RIO09HP115V1A
75
84
19
26
RIO12HP115V1A
75
84
19
26
RIO09HP230V1A
64
73
19
25
RIO12HP230V1A
68
77
20
27
RIO18HP230V1A
106
117
27
35
RIO24HP230V1A
115
126
33
44
Model Numbers Air Filter Fan Motor Fan Type
OUTDOOR UNIT MAJOR COMPONETS
Model Numbers Compressor
PRODUCT WEIGHT
Model Numbers
Net Operating
Metering
Device
Gross Shipping
Inverter
Net Operating
Gross Shipping
14
© 2014 Gree Electric Appliance, Inc.
DIMENSIONAL SPECIFICATIONS
Liquid Line Valve
1/4-in OD Flared
Gas Line Valve
3/8-in OD Flared
Drain Connector
5/8-in OD
Liquid Line Valve
1/4-in OD Flared
Gas Line Valve
3/8-in OD Flared
Model No: RIO09HP115V1A 9,000 BtuH 115V
15
© 2014 Gree Electric Appliance, Inc.
DIMENSIONAL SPECIFICATIONS
Liquid Line Valve
1/4-in OD Flared
Gas Line Valve
3/8-in OD Flared
Drain Connector
5/8-in OD
Liquid Line Valve
1/4-in OD Flared
Gas Line Valve
3/8-in OD Flared
Model No: RIO12HP115V1A 12,000 BtuH 115V
16
© 2014 Gree Electric Appliance, Inc.
DIMENSIONAL SPECIFICATIONS
Liquid Line Valve
1/4-in OD Flared
Gas Line Valve
3/8-in OD Flared
Drain Connector
5/8-in OD
Liquid Line Valve
1/4-in OD Flared
Gas Line Valve
3/8-in OD Flared
Model No: RIO09HP230V1A 9,000 BtuH 230V
17
© 2014 Gree Electric Appliance, Inc.
DIMENSIONAL SPECIFICATIONS
Liquid Line Valve
1/4-in OD Flared
Gas Line Valve
3/8-in OD Flared
Drain Connector
5/8-in OD
Liquid Line Valve
1/4-in OD Flared
Gas Line Valve
3/8-in OD Flared
Model No: RIO12HP230V1A 12,000 BtuH 230V
18
© 2014 Gree Electric Appliance, Inc.
DIMENSIONAL SPECIFICATIONS
Liquid Line Valve
1/4-in OD Flared
Gas Line Valve
1/2-in OD Flared
Drain Connector
5/8-in OD
Liquid Line Valve
1/4-in OD Flared
Gas Line Valve
1/2-in OD Flared
Model No: RIO18HP230V1A 18,000 BtuH 230V
19
© 2014 Gree Electric Appliance, Inc.
DIMENSIONAL SPECIFICATIONS
Liquid Line Valve
1/4-in OD Flared
Gas Line Valve
1/2-in OD Flared
Drain Connector
5/8-in OD
Liquid Line Valve
1/4-in OD Flared
Gas Line Valve
1/2-in OD Flared
Model No: RIO24HP230V1A 24,000 BtuH 230V
20
© 2014 Gree Electric Appliance, Inc.
CLEARANCE SPECIFICATIONS
Unit
A
20 in
508 mm
B
20in
508 mm
C
78 in
1,981 mm
D
12 in
305 mm
E
12in
305 mm
Indoor Minimum Clearance*
Inch (mm)
Outdoor Unit Minimum Clearance*
Outdoor
Minimum Distance
*All Models
21
© 2014 Gree Electric Appliance, Inc.
EXTENDED PERFORMANCE RATINGS
62 F
67 F
72 F
TC
SHC
TC
SHC
TC
SHC
45 F
NA
NA
NA
NA
NA
NA
65F
9,569
7,434
10,520
7,985
11,165
8,152
95F
8,370
6,688
9,000
7,191
9,846
7,394
115F
7,458
6,166
7,911
6,423
8,450
6,629
Indoor Entering Air Temperatures (DB)
TC
SHC
TC
SHC
TC
SHC
15F
8,926
8,926
8,239
8,239
8,231
8,231
25F
9,439
9,439
9,631
9,631
9,559
9,559
45F
12,357
12,357
12,243
12,943
12,386
12,386
Model No: RIO09HP115V1A 9,000 BtuH 115V
COOLING PERFORMANCE
Indoor Entering Air Temperatures (DB) 50% RH
Outdoor Ambient
Temperature (DB)
25 F NA NA NA NA NA NA 35 F NA NA NA NA NA NA
55 F NA NA NA NA NA NA
75F 9,179 7,176 9,910 7,614 10,642 7,859 85F 8,810 7,013 9,445 7,289 10,266 7,666
105F 7,912 6,436 8,532 6,809 9,274 7,115
HEATING PERFORMANCE
Outdoor Ambient
Temperature (DB)
(80% RH)
5F 8,239 8,239 7,881 7,881 7,629 7,629
35F 10,911 10,911 11,392 11,392 10,889 10,889
55F 13,368 13,368 13,116 13,116 12,596 12,596 65F 13,350 13,350 13,203 13,203 12,856 12,856
TC- Total Capacity (BtuH) SHC- Sensible Capacity (BtuH)
Capacity data is based on the following conditions:
Cooling Nominal Test Conditions Heating Normal Test Conditions
Indoor: 80°F DB/67°F WB Indoor: 70°F DB/60°F WB
Outdoor: 95°F DB/75°F WB Outdoor: 47°F DB/43°F W
65 F 70 F 75 F
22
© 2014 Gree Electric Appliance, Inc.
EXTENDED PERFORMANCE RATINGS
62 F
67 F
72 F
TC
SHC
TC
SHC
TC
SHC
45F
NA
NA
NA
NA
NA
NA
65F
12,754
9,920
14,043
10,641
14,890
10,887
95F
11,162
8,916
12,005
9,581
13,125
9,855
115F
9,957
8,204
10,556
8,563
11,289
8,822
Indoor Entering Air Temperatures (DB)
TC
SHC
TC
SHC
TC
SHC
15F
11,598
11,598
10,968
10,968
10,619
10,619
25F
11,845
11,845
11,683
11,683
11,476
11,476
45F
14,195
14,195
13,989
13,989
13,546
13,546
Model No: RIO12HP115V1A 12,000 BtuH 115V
COOLING PERFORMANCE
Indoor Entering Air Temperatures (DB) 50% RH
Outdoor Ambient
Temperature (DB)
25F NA NA NA NA NA NA 35F NA NA NA NA NA NA
55F NA NA NA NA NA NA
75F 12,262 9,571 13,210 10,141 14,187 10,487 85F 11,764 9,347 12,602 9,737 13,650 10,259
105F 10,556 8,571 11,370 9,079 12,361 9,496
HEATING PERFORMANCE
Outdoor Ambient
Temperature (DB)
(80% RH)
5F 9,221 9,221 8,663 8,663 8,436 8,436
35F 12,876 12,876 12,642 12,642 12,535 12,535
55F 14,513 14,513 14,245 14,245 14,128 14,128 65F 14,459 14,459 14,375 14,375 14,274 14,274
TC- Total Capacity (BtuH) SHC- Sensible Capacity (BtuH)
Capacity data is based on the following conditions:
Cooling Nominal Test Conditions Heating Normal Test Conditions
Indoor: 80°F DB/67°F WB Indoor: 70°F DB/60°F WB
Outdoor: 95°F DB/75°F WB Outdoor: 47°F DB/43°F W
65 F 70 F 75 F
23
© 2014 Gree Electric Appliance, Inc.
EXTENDED PERFORMANCE RATINGS
62 F
67 F
72 F
TC
SHC
TC
SHC
TC
SHC
45F
10,286
7,900
11,000
8,162
11,786
8,544
65F
9,565
7,432
10,525
7,988
11,160
8,158
95F
8,370
6,688
9,000
7,191
9,846
7,394
115F
7,469
6,155
7,919
6,415
8,459
6,624
Indoor Entering Air Temperatures (DB)
TC
SHC
TC
SHC
TC
SHC
15F
7,947
7,947
7,250
7,250
7,206
7,206
25F
8,432
8,432
8,003
8,003
7,548
7,548
45F
9,368
9,368
9,050
9,050
8,502
8,502
Model No: RIO09HP230V1A 9,000 BtuH 230V
COOLING PERFORMANCE
Indoor Entering Air Temperatures (DB) 50% RH
Outdoor Ambient
Temperature (DB)
25F 11,073 8,222 11,968 8,665 12,794 9,211 35F 10,821 8,212 11,524 8,412 12,083 8,736
55F 9,903 7,665 10,560 7,920 11,320 8,264
75F 9,189 7,186 9,900 7,613 10,648 7,858 85F 8,820 7,003 9,450 7,295 10,260 7,664
105F 7,920 6,431 8,530 6,807 9,270 7,119
HEATING PERFORMANCE
Outdoor Ambient
Temperature (DB)
(80% RH)
5F 7,435 7,435 7,017 7,017 6,845 6,845
35F 8,903 8,903 8,240 8,240 7,894 7,894
55F 9,380 9,380 9,109 9,109 8,710 8,710 65F 9,336 9,336 9,199 9,199 8,916 8,916
TC- Total Capacity (BtuH) SHC- Sensible Capacity (BtuH)
Capacity data is based on the following conditions:
Cooling Nominal Test Conditions Heating Normal Test Conditions
Indoor: 80°F DB/67°F WB Indoor: 70°F DB/60°F WB
Outdoor: 95°F DB/75°F WB Outdoor: 47°F DB/43°F W
65 F 70 F 75 F
24
© 2014 Gree Electric Appliance, Inc.
EXTENDED PERFORMANCE RATINGS
62 F
67 F
72 F
TC
SHC
TC
SHC
TC
SHC
45F
13,715
10,533
14,666
10,883
15,714
11,393
65F
12,754
9,910
14,033
10,651
14,880
10,877
95F
11,160
8,917
12,000
9,588
13,128
9,859
115F
9,959
8,206
10,559
8,553
11,279
8,832
Indoor Entering Air Temperatures (DB)
TC
SHC
TC
SHC
TC
SHC
15F
10,590
10,590
9,661
9,661
9,603
9,603
25F
11,236
11,236
10,665
10,665
10,058
10,058
45F
12,483
12,483
12,060
12,060
11,329
11,329
Model No: RIO12HP230V1A 12,000 BtuH 230V
COOLING PERFORMANCE
Indoor Entering Air Temperatures (DB) 50% RH
Outdoor Ambient
Temperature (DB)
25F 14,764 10,962 15,958 11,553 17,058 12,282 35F 14,428 10,949 15,365 11,216 16,111 11,648
55F 13,204 10,219 14,080 10,560 15,094 11,018
75F 12,252 9,581 13,200 10,151 14,197 10,477 85F 11,760 9,337 12,600 9,727 13,680 10,219
105F 10,560 8,575 11,374 9,076 12,360 9,492
HEATING PERFORMANCE
Outdoor Ambient
Temperature (DB)
(80% RH)
5F 9,907 9,907 9,350 9,350 9,121 9,121
35F 11,864 11,864 10,981 10,981 10,520 10,520
55F 12,500 12,500 12,139 12,139 11,608 11,608 65F 12,441 12,441 12,259 12,259 11,881 11,881
TC- Total Capacity (BtuH) SHC- Sensible Capacity (BtuH)
Capacity data is based on the following conditions:
Cooling Nominal Test Conditions Heating Normal Test Conditions
Indoor: 80°F DB/67°F WB Indoor: 70°F DB/60°F WB
Outdoor: 95°F DB/75°F WB Outdoor: 47°F DB/43°F W
65 F 70 F 75 F
25
© 2014 Gree Electric Appliance, Inc.
EXTENDED PERFORMANCE RATINGS
62 F
67 F
72 F
TC
SHC
TC
SHC
TC
SHC
45F
20,572
15,799
22,000
16,324
23,571
17,089
65F
19,130
14,864
21,049
15,977
22,320
16,316
95F
16,740
13,375
18,000
14,382
19,692
14,789
115F
14,939
12,309
15,839
12,829
16,919
13,248
Indoor Entering Air Temperatures (DB)
TC
SHC
TC
SHC
TC
SHC
15F
17,079
17,079
15,581
15,581
15,488
15,488
25F
18,121
18,121
17,200
17,200
16,221
16,221
45F
20,133
20,133
19,450
19,450
18,272
18,272
Model No: RIO18HP230V1A 18,000 BtuH 230V
COOLING PERFORMANCE
Indoor Entering Air Temperatures (DB) 50% RH
Outdoor Ambient
Temperature (DB)
25F 22,145 16,443 23,936 17,330 25,587 18,422 35F 21,641 16,423 23,047 16,825 24,167 17,473
55F 19,805 15,329 21,119 15,839 22,640 16,528
75F 18,378 14,371 19,800 15,226 21,296 15,716 85F 17,640 14,006 18,900 14,591 20,520 15,329
105F 15,840 12,862 17,060 13,614 18,540 14,239
HEATING PERFORMANCE
Outdoor Ambient
Temperature (DB)
(80% RH)
5F 15,978 15,978 15,080 15,080 14,710 14,710
35F 19,133 19,133 17,709 17,709 16,966 16,966
55F 20,160 20,160 19,577 19,577 18,720 18,720 65F 20,064 20,064 19,771 19,771 19,162 19,162
TC- Total Capacity (BtuH) SHC- Sensible Capacity (BtuH)
Capacity data is based on the following conditions:
Cooling Nominal Test Conditions Heating Normal Test Conditions
Indoor: 80°F DB/67°F WB Indoor: 70°F DB/60°F WB
Outdoor: 95°F DB/75°F WB Outdoor: 47°F DB/43°F W
65 F 70 F 75 F
26
© 2014 Gree Electric Appliance, Inc.
EXTENDED PERFORMANCE RATINGS
62 F
67 F
72 F
TC
SHC
TC
SHC
TC
SHC
45F
25,144
19,310
26,889
19,951
28,809
20,886
65F
23,381
18,167
25,727
19,527
27,280
19,942
95F
20,460
16,347
22,000
17,578
24,068
18,075
115F
18,259
15,045
19,359
15,680
20,678
16,191
Indoor Entering Air Temperatures (DB)
TC
SHC
TC
SHC
TC
SHC
15F
21,383
21,383
19,508
19,508
19,390
19,390
25F
22,688
22,688
21,534
21,534
20,309
20,309
45F
25,206
25,206
24,351
24,351
22,876
22,876
Model No: RIO24HP230V1A 24,000 BtuH 230V
COOLING PERFORMANCE
Indoor Entering Air Temperatures (DB) 50% RH
Outdoor Ambient
Temperature (DB)
25F 27,066 20,097 29,255 21,181 31,273 22,516 35F 26,450 20,073 28,169 20,564 29,537 21,356
55F 24,206 18,736 25,812 19,359 27,671 20,201
75F 22,462 17,565 24,200 18,610 26,028 19,209 85F 21,560 17,119 23,100 17,833 25,080 18,735
105F 19,360 15,720 20,851 16,640 22,660 17,403
HEATING PERFORMANCE
Outdoor Ambient
Temperature (DB)
(80% RH)
5F 20,004 20,004 18,880 18,880 18,417 18,417
35F 23,954 23,954 22,172 22,172 21,242 21,242
55F 25,240 25,240 24,510 24,510 23,437 23,437 65F 25,120 25,120 24,753 24,753 23,990 23,990
TC- Total Capacity (BtuH) SHC- Sensible Capacity (BtuH)
C
apacity data is based on the following conditions:
Cooling Nominal Test Conditions Heating Normal Test Conditions
Indoor: 80°F DB/67°F WB Indoor: 70°F DB/60°F WB Outdoor: 95°F DB/75°F WB Outdoor: 47°F DB/43°F W
65 F 70 F 75 F
27
© 2014 Gree Electric Appliance, Inc.
ELECTRICAL WIRING
The main power is supplied to the outdoor unit. System must be on a single dedicated circuit. Use appropriate wire size and circuit breaker (or fuse) size for proper system overcurrent protection. Follow all local building codes and NEC (National Electrical Code) regulations.
Interconnecting Cable Wiring Diagram
The indoor unit is powered by the outdoor unit. The interconnecting cable between the outdoor and indoor unit must be a 14/4 AWG stranded copper conductors THHN 600V unshielded wire. The interconnecting cable should not be buried underground and must be recognized by UL or ETL and CSA certified.
Note: Use shield cable if installation is in close proximity of RF and EMI transmitting devices.
© 2014 Gree Electric Appliance, Inc.
28
Local codes may require a disconnect switch within sight of the indoor unit. For these installations, use a DFS Disconnect Switch Accessory Kit (Part No: DFS-SWITCH-A) to break wires going to the N(1), 2, 3 terminals on the indoor unit, as shown in the wiring diagram below:
CONDENSATE REMOVAL
Install condensate drain to safely and effectiv el y route condensate water to a safe location. Use a flexible condensate drain hose to fit over the factory 5/8-inch (16mm) drainage port. The high wall indoor units have an internal condensate trap. Adding an ext ernal trap is not required.
All condensate drains must meet local codes and reg ulations. If adequate gravity drainage cannot be provided, a field-installed condensate pump m ust be used. Refer to manufacturer’s installation instructions, specifications and operating details supplied with condensate pump.
Typical Condensate Pump Wiring Diagram
29
© 2014 Gree Electric Appliance, Inc.
LIMITED WARRANTY STATEMENT
Effective on new GREE Ductless purchases on or after March 1, 2013
Ductless Heat Pump Mini-Split Systems
RIO09HP115V1A RIO12HP115V1A RIO09HP230V1A RIO12HP230V1A RIO18HP230V1A RIO24HP230V1A
GREE distributor (hereinafter “Company”) warrants this product against failure due to defect in materials or workmanship under normal use and maintenance as follows. All warranty periods begin on the date of original installation. If the date cannot be verified, the warranty period begins one hundred twenty (120) days from date of manufacture. If a part fails due to defect during the applicable warranty period Company will provide a new or remanufactu r ed part, at Company’s option, to replace the failed defective part at no charge for the part. This limited warranty is subject to all provisions, conditions, limitations and exclusions listed below.
A warranty period of Seven (7) years on compressor to the original registered end-user.
A warranty period of Five (5) years on all parts to the original registered end u ser .
A warranty period of One (1) year on the remote control provided with the original unit.
Limited warranty applies only to systems that are properly installed by a state certified or licensed
HVAC contractor, under applicable local and state law in accordance with all applicable building codes and permits; GREE installation and operation instructions and good trade practices.
Warranty applies only to products remaining in their original installation location.
Defective parts must be returned to the distributor through a registered servicing dealer for credit.
30
© 2014 Gree Electric Appliance, Inc.
LIMITATIONS OF WARRANTIES: ALL IMPLIED WARRANTIES AND/OR CONDITIONS
(INCLUDING IMPLIED WARRANTIES OR CONDITIONS OF MERCHANT AB ILITY AND FITNESS FOR A PARTICULAR USE OR PURPOSE) ARE L IM IT ED TO THE DURATION OF THIS LIMITED WARRANTY, SOME STATES OR PROVINCES DO NOT AL LOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY OR CONDITION LASTS, SO THE ABOVE MAY NOT APPLY TO YOU. THE EXPRESS WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED, ENLARGED, OR CHANGED BY ANY DIS TR IB UTOR, DEALER, OR OTHER PERSON , WH ATSOEVER.
THIS WARRANTY DOES NOT COVER
:
1. Labor or other costs incurred for diagnosing, repairing, removing, installing, shipping, servicing or handling of either defective parts, or replacement parts, or new units.
2. Product cleaning required prior to warranty service and repair.
3. Normal maintenance as outlined in the installation and servicing instructions or Owner’s Manual, including filter cleaning and/or replacement and lubrication.
4. Failure, damage or repairs due to faulty installation, misapplication, abuse, improper servicing, unauthorized alteration or improper operation.
5. Failure to start due to voltage conditions, blown fuses, open circuit breakers, or damages due to the inadequacy or interruption of electrical ser vice.
6. Failure or damage due to floods, winds, fires, lightning, accidents, corrosive environments (rust, etc.) or other conditions beyond the control of the Company.
7. Failure or damage of coils or piping due to corrosion on installations within one (1) miles of sea coast or corrosive body.
8. Parts not supplied or designated by Company, or damages resulting from their use.
9. Products installed outside continental USA and Canada.
10. Electricity or fuel costs, or increases in electricity or fuel co sts from any reason whatsoever, including additional or unusual use of supplemental electric heat.
11. Any cost to replace, r ef ill or dispose of refrigerant, including the cost of refrigerant.
12. Shipping damage or damage as a result of transporting the unit.
13. Accessories such as condensate pumps, line sets and so fort h are not covered.
14. Any special, indirect or consequential property or commercial damage of any nature whatsoever. Some states or provinces do not allow the exclusion of incidental or consequential damages, so the above limitation may not apply to you.
FOR WARRANTY SERVICE OR REPAIR:
Contact your installing contractor. You may find the installer’s name on the equipment or in your Owner’s packet.
Complete product registration below and send back by e-mail at service@twclimate.com
This warranty gives you specific legal rights, and you may also have other rights which vary from state t o state or province to province.
WSO021513-DLSWARR-HP – Rev. 3-8-13
31
© 2014 Gree Electric Appliance, Inc.
Specifications in this booklet are subject to change without notice. Manufacturer reserves the right to discontinue or modify specifications or designs without notice or without incurring obligations. All rights reserved.
Cat No. RIO-2TPG