Gree FXA2A-D, FXA3A-D, RFX12A, RFX13A Owner's Manual

Super Free Match Series
R410A Systems—BU module
Owner's Manual
Gree Air Conditioners
FXA2A-D
FXA3A-D
Thank you for choosing Gree air conditioners, please read this owner’s manual carefully before
operation and keep it for future reference.
Preface
Super Free Match Series Systems adopt the advanced manufacturing technology and takes the
environmental-friendly R410A as refrigerant, which is a green product in the 21st century. Please
carefully read the manual before installation and operation.
The total capacity of the indoor units which runs at the same time cannot exceed the capacity of
the outdoor units; otherwise, the cooling (heating) effect of each indoor unit would be lower
than the nominal capacity.
Make sure that the manual is kept by the operators or serviceman. The refrigerant pipes and accessories must be designed exclusively for R410A. It is a normal phenomenon that the fan of indoor unit will still run for 20~70 seconds after the
indoor unit receives the “stop” signal so as to make full use of the waste heat.
When the work mode of the indoors is conflict with the modes of outdoor units, it will be
indicated on the display of the wired controller in five seconds and then the indoor unit will
stop. In this case, please harmonize their work modes: the cooling mode is compatible with the
dry mode.
If the supply power fails when the unit is running, then the indoor unit will send the “start”
signal to the outdoor unit three minutes later after the power recovery.
The power cable and transmission line must not be twisted together, but instead of separated
with an interval of at least 2cm; otherwise it may be result in communication problem.
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety. Children should be supervised to ensure that they do not play with the appliance.
Cautions for the debugging and maintenance personnel:
During debugging and maintenance, before the startup of the compressor, it makes sure that the
heater belt of the compressor has been energized for at least eight hours! Once the compressor is
started, it must be guaranteed that it works continuously for at least 30 minutes, otherwise it would
be damaged!
This product must not be disposed together with the domestic waste. This product has
to be disposed at an authorized place for recycling of electrical and electronic appliances.
Thank you for purchasing GREE air conditioners. Before using, please read this
manual carefully and keep it properly for further reference.
Contents
1 Safety Precautions.........................................................................................................................1
2 Product Introduction .....................................................................................................................3
2.1 Names of Main Parts.........................................................................................................3
2.2 Combinations for Outdoor and Indoor Units ....................................................................3
2.3 Parts and Components of Unit ..........................................................................................4
2.4 Working Temperature Range ............................................................................................4
3 Selection of Installation Location and Precautions.......................................................................5
3.1 Selection of Installation Location .....................................................................................5
3.2 Outline Dimension and Servicing Space of FXA2A-D ....................................................6
3.3 Outline Dimension and Servicing Space of FXA3A-D ....................................................7
3.4 Outline Dimension and Servicing Space of RFX12A .......................................................8
3.5 Outline Dimension and Servicing Space of RFX13A .......................................................9
4 Installation Instruction ................................................................................................................10
5 Installation of Refrigerant Pipes .................................................................................................11
5.1 Manifold Mode of Connecting Pipe................................................................................11
5.2 Allowable Length and Drop Height of Connecting Pipe ................................................12
5.3 Installation of Piping Adapter (FXA2A-D and FXA3A-D)............................................12
5.4 Installation of Piping Adapter (RFX12A and RFX13A) ................................................13
5.5 Precaution for Connection ..............................................................................................15
6 Electrical Wiring Work ...............................................................................................................17
6.1 Wiring Connection..........................................................................................................17
6.2 Requirements of Power Circuit and Cable......................................................................17
6.3 Ground Requirements .....................................................................................................18
6.4 Precautions on the Electrical Wiring Work .....................................................................18
6.5 Precaution of Laying Wires.............................................................................................18
6.6 Procedures for Electrical Wiring Work ...........................................................................19
6.7 Instructions for DIP Switch.............................................................................................21
7 Design of Drainage Pipeline .......................................................................................................22
7.1 Installation of Drain Hose...............................................................................................22
7.2 Design of Drainage Pipeline ...........................................................................................22
8 Test Operation .............................................................................................................................22
9 Troubleshooting ..........................................................................................................................23
10 After-Sales Service .....................................................................................................................23
BU Module
1
1 Safety Precautions
Warn in g! :It indicates improper operation might lead to human casualty or sever injury
Caution! : It indicates that improper operation might lead to personal injury or property
damage.
BU Module
2
GREE is not responsible of personal injury or equipment damage caused by improper installation
and commission, unnecessary service and incapable of following the rules and instructions listed in
the manual.
BU Module
3
2 Product Introduction
The BU module of Gree Super Free Match Series is the latest branch device, which adopts the
intelligent control technology. Respond to the changes in load of the indoor units, it can coordinate
the flow rate of the refrigerant well. Otherwise, it is very compact and has a flexible choice about the
installation location, such as the ceiling of parlor, corridor, balcony,storeroomand etc.
2.1 Names of Main Parts

a) FXA2A-D b) FXA3A-D
c) RFX12A d) RFX13A
NO.
ķ ĸ Ĺ ĺ
Name
Gas piping of indoor unit
side
Liquid piping of indoor
unit side
Electrical
equipment plate
Hanger
metal
NO.
Ļ ļ Ľ ľ
Name
Liquid piping of outdoor
unit side
Gas piping of outdoor unit
side
Drain hole
Printed
circuit board
Fig. 1
2.2 Combinations for Outdoor and Indoor Units
Table 1
Sorts FXA2A-D and RFX12A FXA3A-D and RFX13A
Min 1 1
No. of connectable indoor units
Max 2 3
BU Module
4
2.3 Parts and Components of Unit
For the Super Free Match Series, one outdoor unit is able to drive up to three BU modules and
nine indoor units which include cassette type, duct type, wall-mounted type, floor ceiling type and
console type. The outdoor unit will run as long as any one indoor unit receives the running command,
and all indoor units stop once the outdoor unit is turned off.
Fig. 2
2.4 Working Temperature Range
Table 2
Sorts
Outside temperature DB/WB(ć)
Maximum 50/-
Minimum -15/-
BU Module
5
3 Selection of Installation Location and Precautions
-------------------------------------------------------------------------------------------------------------------------
Caution!
The installation of the air conditioner must be in accordance with the national and local laws
and regulations.
The quality of the installation will affect the capability of air conditioner directly. The
installation should be left to the appointed service center. Please contact your dealer after
purchasing this machine. Professional installation workers will provide installation and test
services according to the installation manual.
The air conditioner should not install in this place where the small animals exist, because they
may cause malfunctions, smoke or fire.
Please keep the area around the unit clean.
-------------------------------------------------------------------------------------------------------------------------
3.1 Selection of Installation Location
The BU module is for indoor use. If installing in the outdoors, the location must be away from
wind and rain. Otherwise, it maybe causes water leakage, electric shocks or fire etc.
The BU module must be installed on a firm and solid support which can withstand the weight
of the module and the mounting surface must be horizontal plane. The BU module can be
chosen to install in the ceiling, such as the ceiling of parlor, corridor, balcony, storeroom and etc
There is enough space for the installation and maintenance. Avoid direct sunlight or other heat sources exist. Do not install in location that is hot or humid for long periods of time. Avoid the BU module installed in the bedroom and study, where these places need to be quiet. BU module cannot be installed in the place of inflammable and explosive materials and severe
dust, smoke and the other air pollution, such as the kitchen.
There is enough space to install drainage pipe, so that the condensed water can be discharged.
-------------------------------------------------------------------------------------------------------------------------
Caution!
Installation at the following places might lead to the air conditioner malfunction. If it is
unavoidable, please contact the appointed service center.
A place which is full of machine oil; A region with saline-sodic soil near the sea; A place where the sulphide fog exists, such as the sulphur spring; A place where the high frequency facilities exist, such as radio equipment, electric welder and
medical equipment;
An environment with special conditions.
-------------------------------------------------------------------------------------------------------------------------