Thank you for choosing a Multi21
Ductless Heat Pump for your customer.
Please read this installation manual carefully before installing and starting up the
Multi21 System. Take a moment to fill out the product and installation form on the
back cover. Retain both the manual and installation record for future reference.
This is the safety alert symbol. It is used to alert you to potential
personal injury hazards. Obey all safety messages that follow this
symbol to avoid possible injury or death.
WARNING
CAUTION
NOTICE
This mark indicates procedures which, if improperly performed,
might lead to the death or serious injury of the user.
This mark indicates procedures which, if improperly performed, might
possibly result in personal harm to the user, or damage to property.
Notice is used to address practices not related to personal injury.
General Safety Precautions
1. Instructions for installation and use of this product are provided by the manufacturer.
For proper operation, the system must be installed in accordance with this
installation manual.
2. Installation must be performed in accordance with local laws, regulations and
National Electrical Codes (NEC).
3. If refrigerant leaks while work is being carried out, ventilate the area. Do not allow
refrigerant to come in contact with a flame as it produces toxic gas.
4. Disconnect all electrical power to the indoor and outdoor units until the system is
ready for start-up and checkout.
5. When installing or repairing the system, use only R410A refrigerant. Do not
mix refrigerant with other gases. If air or other gas enter the refrigeration system,
the pressure inside the system may rise to an abnormally high value and cause
damage or injury.
WARNING
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person responsible for their safety.
2
NOMENCLATURE
Outdoor Unit
3
SYSTEM REQUIREMENTS
nit Size (BtuH)
U
ort A1/4 (6)3/8 (9.5)
18,000
4,000Port B1/4 (6)3/8 (9.5)
2
30,000
36,000
42,000Port C1/4 (6)3/8 (9.5)
P
Port B1/4 (6)3/8 (9.5)
Port A1/4 (6)3/8 (9.5)
Port C1/4 (6)3/8 (9.5)
Port A1/4 (6)3/8 (9.5)
Port B1/4 (6)3/8 (9.5)
Port C1/4 (6)3/8 (9.5)
Port D1/4 (6)3/8 (9.5)
Port A1/4 (6)3/8 (9.5)
Port B1/4 (6)3/8 (9.5)
Port C1/4 (6)3/8 (9.5)
Port D1/4 (6)3/8 (9.5)
Port E1/4 (6)3/8 (9.5)
Port A1/4 (6)3/8 (9.5)
Port B1/4 (6)3/8 (9.5)
Port D1/4 (6)3/8 (9.5)
Port E1/4 (6)3/8 (9.5)
Liquid Line
REFRIGERANT PIPE LENGTHS
Unit Size Max Total Pipe
(BtuH)Length ft(m)Pipe Length ft(m)PipeLength ft(m)IND Units ft(m)IND& OTDUnitsft(m)
**Main power wire from electrical panel to outdoor unit. AWG based on 240VAC Single Phase, 100 ft. distance 1-way, max. 5% allowable voltage drop.
Voltage
Min CircuitMax OvercurrentMain Power
Notes: 1) System must be on a single dedicated circuit.
2) Main power is supplied to the outdoor unit.
3) Use table above to size over current protection.
4) Follow all local building codes and NEC (National Electrical Code) regulations.
Interconnecting Cable: Recommended cable - 14/4 AWG stranded bare copper conductors THHN 600V unshielded wire
Note: Use shield cable if installation is in close proximity of RF and EMI transmitting devices.
4
SUGGESTED TOOLS
• Standard Wrench
• Adjustable/Crescent Wrench
• Torque Wrench
• Hex Keys or Allen Wrenches
• Drill & Drill Bits
• Hole Saw
• Pipe Cutter
• Screw drivers (Phillips & Flat blade)
• Manifold and Gauges
• Level
• R410A Flaring Tool
• Clamp on Amp Meter
• Vacuum Pump
• Safety Glasses
• Work Gloves
• Refrigerant Scale
• Micron Gauge
5
INSTALLATION SITE INSTRUCTIONS
Indoor Unit
Select a site that allows for the following:
1. Ensure the installation complies with the installation minimum dimensions (defined below)
and meets the minimum and maximum connecting piping length and maximum change in
elevation as defined in the System Requirements section.
2.
Air inlet and outlet will be clear of obstructions, ensuring proper airflow throughout the room.
3. Condensate can be easily and safely drained.
4. All connections can be easily made to outdoor unit.
5. Indoor unit is out of reach of children.
6.
A mounting structure (i.e. wall, ceiling, floor,...) strong enough to withstand four times the full
weight and vibration of the unit.
7. Filter can be easily accessed for cleaning.
8. Leave enough free space to allow access for routine maintenance.
9. Install at least 10 ft. (3 m) away from the antenna of TV set or radio. Operation of the air
conditioner may interfere with radio or TV reception in areas where reception is weak.
An amplifier may be required for the affected device.
10. Do not install in a laundry room or by a swimming pool due to the corrosive environment.
Minimum Indoor Clearances - High Wall Units
Ceiling
6 in (0.15m)
6 in
(0.15m)
6 ft (1.8m)
Floor
NOTE:
For minimum clearances of other indoor unit types, refer to
6 in
(0.15m)
the Installation Instructions enclosed with those indoor units.
6
INSTALLATION SITE INSTRUCTIONS
Outdoor Unit
Select a site that allows the following:
1. Install the outdoor unit at a location that is capable of withstanding twice the weight of the unit.
2. Install the outdoor unit where it is convenient to connect refrigerant lines to the indoor units.
3. Install the outdoor unit where the condensate water can be drained unobstructed during the
heating mode to a safe location.
4. Do not locate the unit where the noise may be objectionable to neighbors.
5. Provide the space shown below, so that the air flow is not blocked and future service and