Thank you for choosing our product.
Please read this Owner’s Manual carefully before operation and
retain it for future reference.
If you have lost the Owner's Manual, please contact your local
distributor or visit www.greecomcomfort.com/resources for the
electronic version.
Page 2
In line with the company’s policy of continual product improvement, the aesthetic and dimensional
characteristics, technical data and accessories of this appliance may be changed without notice.
CONTENTS
Conformity And Range
Warning
The Instructions Before Use
Name of Parts
GENERAL
INFORMATION
Outdoor Unit Working Temperature Range
Electrical Connections
Installing The Outdoor Unit
Bleeding
Maintenance
INSTALLER
Installation Dimension Diagram
Check After Installation
GENERAL INFORMATION
1
2
5
6
6
7
11
11
12
12
13
The products in this manual may be different with the rea one, according to different models,
some models have displayer and some models without displayer, the position and shape of
the displayer please refer to the real one.
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety.
Children should be supervised to ensure that they do not play with the appliance.
If it needs to install, move or maintain the air conditioner, please contact dealer or local service
center to conduct it at first. Air conditioner must be installed, moved or maintained by appointed
unit. Otherwise, it may cause serious damage or personal injury or death.
When refrigerant leaks or requires discharge during installation, maintenance, or disassembly,
it should be handled by certified professionals or otherwise in compliance with local laws and
regulations.
Page 3
DANGER
WARNING
CAUTION
N OTIC E
GENERAL INFORMATIONEXPLANATION OF SYMBOLS
Indicates a hazardous situation that, if not avoided, will
result in death or serious injury.
Indicates a hazardous situation that, if not avoided, could
result in death or serious injury.
Indicates a hazardous situation that, if not avoided, may
result in minor or moderate injury.
Indicates important but not hazard-related information,
used to indicate risk of property damage.
Indicates a hazard that would be assigned a signal word
WARNING or CAUTION.
GENERAL INFORMATIONEXCEPTION CLAUSES
Manufacturer will bear no responsibilities when personal injury or
property loss is caused by the following reasons.
1.Damage the product due to improper use or misuse of the product;
2.Alter, change, maintain or use the product with other equipment without abiding
by the instruction manual of manufacturer;
3.After verification, the defect of product is directly caused by corrosive gas;
After verification, the defects are due to improper operation during transportation
4.
of product;
5.Operate, repair, maintain the unit without abiding by instruction manual or related
regulations;
6.After verification, the problem or dispute is caused by the quality specification or
performance of parts and components that produced by other manufacturers;
7.The damage is caused by natural calamities, bad using environment or force
majeure.
CONFORMITY AND RANGE
GENERAL INFORMATION
Please read this owner's manual carefully before operating the unit and keep it
carefully for consultation.
Only use the air conditioner as instructed in this booklet. These instructions are
not intended to cover every possible condition and situation. As with any electrical
household appliance, common sense and caution are therefore always
recommended for installation, operation and maintenance.
1
Page 4
WARNING
GENERAL INFORMATION
Operation and Maintenance
This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards
involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without
supervision.
Do not connect air conditioner to multi-purpose socket. Otherwise, it may
cause fire hazard.
Do disconnect power supply when cleaning air conditioner. Otherwise, it
may cause electric shock.
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
Do not wash the air conditioner with water to avoid electric shock.
Do not spray water on indoor unit. It may cause electric shock or malfunction.
After removing the filter, do not touch fins to avoid injury.
Do not use fire or hair dryer to dry the filter to avoid deformation or fire hazard.
Maintenance must be performed by qualified professionals. Otherwise, it may
cause personal injury or damage.
Do not repair air conditioner by yourself. It may cause electric shock or damage.
Please contact dealer when you need to repair air conditioner.
Do not extend fingers or objects into air inlet or air outlet. It may cause personal
injury or damage.
Do not block air outlet or air inlet. It may cause malfunction.
Do not spill water on the remote controller, otherwise the remote controller may
be broken.
When below phenomenon occurs, please turn off air conditioner and disconnect
power immediately
and then contact the dealer or qualified professionals for
service.
Power cord is overheating or damaged.
There’s abnormal sound during operation.
Circuit break trips off frequently.
Air conditioner gives off burning smell.
Indoor unit is leaking.
2
Page 5
WARNING
GENERAL INFORMATION
If the air conditioner operates under abnormal conditions, it may cause
malfunction,electric shock or fire hazard.
When turning on or turning off the unit by emergency operation switch, please
press this switch with an insulating object other than metal.
Do not step on top panel of outdoor unit, or put heavy objects. It may cause
damage or personal injury.
Attachment
Installation must be performed by qualified professionals. Otherwise, it may
cause personal injury or damage.
Must follow the electric safety regulations when installing the unit.
According to the local safety regulations, use qualified power supply circuit
and circuit break.
Do install the circuit break. If not, it may cause malfunction.
An all-pole disconnection switch having a contact separation of at least 3mm in
all poles should be connected in fixed wiring.
Including an circuit break with suitable capacity, please note the following table.
Air switch should be included magnet buckle and heating buckle function, it can
protect the circuit-short and overload.
Air Conditioner should be properly grounded. Incorrect grounding may cause
electric shock.
Don't use unqualified power cord.
Make sure the power supply matches with the requirement of air conditioner.
Unstable power supply or incorrect wiring may result in electric shock, fire
hazard or malfunction. Please install proper power supply cables before using
the air conditioner.
Properly connect the live wire, neutral wire and grounding wire of power socket.
Be sure to cut off the power supply before proceeding any work related to
electricity and safety.
Do not put through the power before finishing installation.
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
The temperature of refrigerant circuit will be high, please keep the
interconnection cable away from the copper tube.
The appliance shall be installed in accordance with national wiring regulations.
Installation must be performed in accordance with the requirement of NEC and
CEC by authorized personnel only.
3
Page 6
WARNING
GENERAL INFORMATION
The air conditioner is the first class electric appliance. It must be properly
grounding with specialized grounding device by a professional. Please make
sure it is always grounded effectively, otherwise it may cause electric shock.
The yellow-green wire in air conditioner is grounding wire, which can't be used
for other purposes.
The grounding resistance should comply with national electric safety regulations.
The appliance must be positioned so that the plug is accessible.
All wires of indoor unit and outdoor unit should be connected by a professional.
If the length of power connection wire is insufficient,please contact the
supplier for a new one. Avoid extending the wire by yourself.
For the air conditioner with plug,the plug should be reachable after finishing
installation.
For the air conditioner without plug, an circuit break must be installed in the line.
If you need to relocate the air conditioner to another place, only the qualified
person can perform the work. Otherwise, it may cause personal injury or damage.
Select a location which is out of reach for children and far away from animals or
plants.If it is unavoidable, please add the fence for safety purpose.
The indoor unit should be installed close to the wall.
4
Page 7
THE INSTRUCTIONS BEFORE USEGENERAL INFORMATION
WARNING
When having a burning smell or
★★
smoke,please turn off the power
supply and contact with the service center.
If the abnormity still exists,the unit
may be damaged,and may cause
electric shock or fire.
Power must adopts the special
★
circuit to prevent fire.
Otherwise, it can cause electric
shock or fire.
★★
Otherwise,the accumulated dusts
may cause overheating or fire.
The power supply must adopt the
special circuit that with air switch
protection and assure it has enough capacity.The unit will be turned
on or off according to your requirement automatically,please do not
turn on or turn off the unit frequently,otherwise disadvantage effect
may be caused to the unit.
Disconnect the power supply if
long putting the air conditioner
out of use.
Never cut off or damage power
★
cables and control wires. If the
power cable and signal control
wire were damaged, change
them by professional.
Never damage the electric wire
or use the electric wire which is
not appointed.
Otherwise,it will cause overheating
or fire.
When cleaning,it is necessary
★★
to stop driving and turn off the
power supply.
Cut off power supply
Otherwise,it may cause electric
shock or damage.
Please note whether the insta-
★★
lled stand is firm enough or not.
Rated voltage of this air conditioner 220-240V, 50Hz, The compressor will vibrate sharply if the
voltage is too low, resappointed.
amage to refrigerating system.
Electrical component are easy to
damage if the voltage is too high.
Don't step on the top of the
outdoor unit or place something
on it.
Don't attempt to repair the air
★
conditioner by yourself.
The wrong repair will lead to an
electric shock or fire,so you should
contact the service center to repair.
Earthing: The unit must be reli-
★
ably earthed.The earthing cable
shall be connected to the special earthing device in the construction.
If it is damaged, it may lead to the
fall of the unit and cause the injury.
As falling off the outdoor unit can be
dangerous.
5
Page 8
NAME OF PARTSGENERAL INFORMATION
WARNING
Be sure to cut off the power supply before cleaning the air conditioner; otherwise electric shock might happen.
any case.
Volatile liquids such as thinner or gasoline will cause damage to the appearance of air conditioner. (Only use
soft dry cloth moist cloth clean the air conditioner cabinet).
This product must not be disposed together with the domestic waste.
This product has to be disposed at an authorized place for recycling of electrical and electronic appliances.
The temperature of refrigerant circuit will be high,please keep the interconnection cable away from the copper
tube.
1
OUTDOOR UNIT
No.Description
1Air outlet grille
2Valve
ni renoitidnoc ria ruoy hsaw ot ton erus ekaM .kcohs cirtcele fo ksir eht esuac yam renoitidnoc ria fo gnitteW
Note: The above figures are only intended to a simple
diagram of the appliance and may not correspond to the
appearance of the units that have been purchased.
OUTDOOR UNIT WORKING TEMPERATURE RANGEGENERAL INFORMATION
2
Indoor side DB/WB(°C/°F)Outdoor side DB/WB(°C/°F)
Maximum cooling26.7/19.4(80/67)43/24(109/75)
Maximum heating26.7/-(80/-)
23.9/18.3(75/65)
● The operating temperature range (outdoor temperature) for cooling only unit is
-30°C ~ 43°C(-22°F ~ 109°F); for heat pump unit is -30°C ~ 43°C(-22°F ~ 109°F).
6
Page 9
ELECTRICAL CONNECTIONS
MULTI18HP230V1EO
1.
Remove the handle at the right side plate of the
outdoor unit (one screw).
2.
Remove the cable clamp, connect the power
connection cable with the terminal at the row of
connection and fix the connection. The fitting line
distributing must be consistent with the indoor
unit. terminal of line bank. Wiring should meet
that of indoor unit.
3. Fix power connection wire by wire clamp.
4.
Ensure wire has been fixed well.
5.
Install the handle.
Including an air switch with suitable capacity,
please note the following table. Air switch
should be included magnet buckle and heating
buckle function, it can protect the circuit-short
and overload. (Caution: please do not use the
fuse only for protect the circuit)
Air-conditionerAir switch capacity
MULTI18HP230V1EO20A
INSTALLER
An all-pole disconnection switch having a contact
separation of at least 3mm in all pole should be
connected in fixed wiring.
Wrong wire connection may cause malfunction of
some electric components.After fixing cable, ensure
that leads between connection to fixed point have
some space.
The connection pipes and the connection wirings
of the unit A, unit B must be corresponding to each
other respective.
The appliance shall be installed in accordance with
national wiring regulations.
Note: The above figures are only intended to be a simple
diagram of the appliance and may not correspond to the
appearance of the units that have been purchased.
L1
L1(1)L2(3)
2
green
(yellow
-green)
black red
(blue)
INDOOR UNIT A
HANDLING
After having removed the packaging, check that the
contents are intact and complete.
The outdoor unit must always be kept upright.
To unit A
Power cord
A
(brown)
To unit B
3
2
L2
connecting
connecting
cable
cable
To the power supply
B
N(1)
2 3
white blackwhite
L1 L2
POWER
green
(yellow
-green)
white
(blue)(blue)
red
black
(brown)(brown)
INDOOR UNIT B
green
(yellow
-green)
USER
Handling must be done by suitably equipped qualified
technical personnel using equipment that is for suitable
the weight of the appliance.
7
Page 10
ELECTRICAL CONNECTIONS
1.
Remove the handle at the right side plate of the
outdoor unit (one screw).
2.
Remove the cable clamp, connect the power
connection cable with the terminal at the row of
connection and fix the connection. The fitting line
distributing must be consistent with the indoor
unit. terminal of line bank. Wiring should meet
that of indoor unit.
3. Fix power connection wire by wire clamp.
4.
Ensure wire has been fixed well.
5.
Install the handle.
Including an air switch with suitable capacity,
please note the following table. Air switch
should be included magnet buckle and heating
buckle function, it can protect the circuit-short
and overload. (Caution: please do not use the
fuse only for protect the circuit)
Air-conditionerAir switch capacity
MULTI24HP230V1EO25A
INSTALLER
An all-pole disconnection switch having a contact
separation of at least 3mm in all pole should be
connected in fixed wiring.
Wrong wire connection may cause malfunction of
some electric components.After fixing cable, ensure
that leads between connection to fixed point have
some space.
The connection pipes and the connection wirings
of the unit A, unit B and unit C must be corresponding
to each other respective.
The appliance shall be installed in accordance with
national wiring regulations.
Note: The above figures are only intended to be a simple
diagram of the appliance and may not correspond to the
appearance of the units that have been purchased.
black
(brown)
L1 L2
POWER
L1 L2
L2L1
white
(blue)
Power cord
green
(yellow-green)
N(1)
whitered
black
(blue)
INDOOR UNIT A
To unit BTo unit A
connecting
cable
A
33232
2
green
(brown)
(yellow-green)
B
N(1)
whitered
black
(blue)
INDOOR UNIT B
connecting
cable
(brown)
green
(yellow-green)
To unit C
connecting
cable
To the power supply
C
N(1)
whitered
(brown)
black
(blue)
INDOOR UNIT C
green
(yellow-green)
8
Page 11
ELECTRICAL CONNECTIONS
1.
Remove the handle at the right side plate of the
outdoor unit (one screw).
2.
Remove the cable clamp, connect the power
connection cable with the terminal at the row of
connection and fix the connection. The fitting line
distributing must be consistent with the indoor
unit. terminal of line bank. Wiring should meet
that of indoor unit.
3. Fix power connection wire by wire clamp.
4.
Ensure wire has been fixed well.
5.
Install the handle.
Including an air switch with suitable capacity,
please note the following table. Air switch
should be included magnet buckle and heating
buckle function, it can protect the circuit-short
and overload. (Caution: please do not use the
fuse only for protect the circuit)
Air-conditionerAir switch capacity
MULTI30HP230V1EO35A
MULTI36HP230V1EO45A
INSTALLER
An all-pole disconnection switch having a contact
separation of at least 3mm in all pole should be
connected in fixed wiring.
Wrong wire connection may cause malfunction of
some electric components.After fixing cable, ensure
that leads between connection to fixed point have
some space.
The connection pipes and the connection wirings
of the unit A, unit B, unit C and unit D must be corr-
esponding to each other respective.
The appliance shall be installed in accordance with
national wiring regulations.
Note: The above figures are only intended to be a simple
diagram of the appliance and may not correspond to the
appearance of the units that have been purchased.
black
(brown)
L1 L2
POWER
L1 L2
L2L1
white
(blue)
Power cord
green
(yellow-green)
A
2
N(1)
whitered
black
(blue)
INDOOR UNIT A
To unit BTo unit A
connecting
cable
connecting
cable
B
33232
green
(brown)
(yellow-green)
N(1)
whitered
black
(blue)
INDOOR UNIT B
(brown)
green
(yellow-green)
To unit C
connecting
cable
C
N(1)
whitered
black
(blue)
INDOOR UNIT C
To the power supply
green
(brown)
(yellow-green)
To unit D
connecting
cable
N(1)
whitered
black
(blue)
INDOOR UNIT D
D
(brown)
32
green
(yellow-green)
9
Page 12
ELECTRICAL CONNECTIONS
1.
Remove the handle at the right side plate of the
outdoor unit (one screw).
2.
Remove the cable clamp, connect the power
connection cable with the terminal at the row of
connection and fix the connection. The fitting line
distributing must be consistent with the indoor
unit. terminal of line bank. Wiring should meet
that of indoor unit.
3. Fix power connection wire by wire clamp.
4.
Ensure wire has been fixed well.
5.
Install the handle.
Including an air switch with suitable capacity,
please note the following table. Air switch
should be included magnet buckle and heating
buckle function, it can protect the circuit-short
and overload. (Caution: please do not use the
fuse only for protect the circuit)
Air-conditionerAir switch capacity
MULTI42HP230V1EO45A
INSTALLER
An all-pole disconnection switch having a contact
separation of at least 3mm in all pole should be
connected in fixed wiring.
Wrong wire connection may cause malfunction of
some electric components.After fixing cable, ensure
that leads between connection to fixed point have
some space.
The connection pipes and the connection wirings
of the unit A, unit B, unit C, unit D and unit E must be
corresponding to each other respective.
The appliance shall be installed in accordance with
national wiring regulations.
Note: The above figures are only intended to be a simple
diagram of the appliance and may not correspond to the
appearance of the units that have been purchased.
black
(brown)
L1 L2
POWER
L1 L2
L2L1
white
(blue)
Power cord
green
(yellow-green)
A
2
N(1)
whitered
black
(blue)
INDOOR UNIT A
To unit BTo unit A
connecting
cable
connecting
cable
B
33232
green
(brown)
(yellow-green)
N(1)
whitered
black
(blue)
INDOOR UNIT B
(brown)
green
(yellow-green)
To unit C
connecting
cable
C
N(1)
whitered
black
(blue)
INDOOR UNIT C
(brown)
green
(yellow-green)
To unit D
connecting
cable
N(1)
whitered
black
(blue)
INDOOR UNIT D
D
(brown)
To unit E
To the power supply
32
green
(yellow-green)
connecting
cable
N(1)
whitered
(blue)
E
32
(brown)
black
INDOOR UNIT D
green
(yellow-green)
10
Page 13
INSTALLING THE OUTDOOR UNITINSTALLER
Location
Use bolts to secure the unit to a flat, solid floor.
When mounting the unit on a wall or the roof, make
sure the support is firmly secured so that it cannot
move in the event of intense vibrations or a strong
wind.
Do not install the outdoor unit in pits or air vents
Installing the pipes
Use suitable connecting pipes and equipment for
the refrigerant R410A.
Tighten the connections using two wrenches working in opposite directions.
24K
60
20
30K
80
25
36K
80
25
42K
100
25
Caution: Installation Must be Performed in
Accordance with the NEC/CEC by Authorized
Personnel Only.
Install the drain fitting and the drain hose
(for model with heat pump only)
Condensation is produced and flows from the outdoor unit when the appliance is operating in the
heating mode. In order not to disturb neighbours
and to respect the environment,install a drain fitting
and a drain hose to channel the condensate water.
Install the drain fitting and rubber washer on the
outdoor unit chassis and connect a drain hose to it
as shown in the figure.
BLEEDINGINSTALLER
Humid air left inside the refrigerant circuit can cause compressor malfunction. After having connected the indoor
and outdoor units, bleed the air and humidity from the
refrigerant circuit using a vacuum pump.
(1) Unscrew and remove the caps from the 2-way and 3 way valves.
(2) Unscrew and remove the cap from the service valve.
(3) Connect the vacuum pump hose to the service valve.
(4) Operate the vacuum pump for 10-15 minutes until an
absolute vacuum of 10 mm Hg has been reached.
(5) With the vacuum pump still in operation, close the
low-pressure knob on the vacuum pump coupling.
Stop the vacuum pump.
(6) Open the 2-way valve by 1/4 turn and then close it
after 10 seconds. Check all the joints for leaks using
liquid soap or an electronic leak device.
(7) Turn the body of the 2-way and 3-way valves. Discon nect the vacuum pump hose.
(8) Replace and tighten all the caps on the valves.
Diameter
1/4''
3/8''
5/8''
1/2''
3/4''70-75
Twisting moment (N.m)
15-20
35-40
60-65
45-50
When the adaptor is required for the connection of indoor
unit and the 24K、30K、36K、42K outdoor unit, the method
of pipe connection as follows:
conversion joint
Service
inlet
(2)Turn
(8) Secure
Refrigerant fluid di
3-w
Vacuum pump
INDOOR
UNIT
rection of fiow
ay valve
(7)Turn to open fully
Valve cap
Vacuum pump
(8) Secure
2-w
(2)Turn
ay valve
(6) Open by 1/4 turn
(7)Turn to open fully
V
alve cap
Vacuum pump
(2)Turn
(8) Secure
Connect to the
indoor unit
11
Page 14
MAINTENANCEINSTALLER
Use suitable instruments for the refrigerant R410A.
Do not use any other refrigerant than R410A.
Do not use mineral oils to clean the unit.
INSTALLATION DIMENSION DIAGRAM
The installation must be done by trained and qualified service personnel with reliability according to this
manual.
Contact service center before installation to avoid the malfunction due to unprofessional installation.
When picking up and moving the units, you must be guided by trained and qualified person.
Ensure that the recommended space is left around the appliance.
50cm
or more
Space to the cover
30c m
or above
Space to the cover
200cm
(Air outlet side)
or above
30cm
(Air inlet side)
INSTALLER
or above
50cm
or above
Space to the wall
Fix the support of outdoor unit (select it according to the actual installation situation)
1.
Select installation location according to the house structure.
2. Fix the support of outdoor unit on the selected location with expansion
screws.
NOTICE:
Take sufficient protective measures when installing the outdoor unit.
Make sure the support can withstand at least four times of the unit
weight.
The outdoor unit should be installed at least 3cm above the floor in
order to install drain joint. (for the model with heating tube, the
installation height should be no less than 20cm.)
For the unit with cooling capacity of 2300W ~ 5000W, 6 expansion
screws are needed; for the unit with cooling capacity of 6000W~
8000W, 8 expansion screws are needed; for the unit with cooling
capacity of 10000W~16000W, 10 expansion screws are needed.
As for the shape of drainage joint, please refer to the current product.
Do not install the drainage joint in the severe cold area. Otherwise,
it will be frosted and then cause malfunction.
12
at least 3cm above the floor
Page 15
CHECK AFTER INSTALLATIONINSTALLER
Check Items
Is the installation reliable?
Has the gas leakage been checked?
Is the thermal insulation of the unit
sufficient?
Is the drainage smooth?
Does the power supply voltage accord
with the rated voltage specified on the
nameplate?
Are the lines and pipelines correctly
installed?
Has the unit been safely grounded?
Problems Owing to Improper Installation
The unit may drop, vibrate or make noises
May cause unsatisfactory cooling (heating)
effect
May cause condensation and water dropping
May cause condensation and water dropping
The unit may bread down or the components
may be burned out
The unit may bread down or the components
may be burned out
Risk of electrical leakage
Are the models of lines in conformity
with requirements?
Are there any obstacles near the air
inlet and outlet of the indoor and outdoor units?
Have the length of refrigerating pipe
and refrigerant charge amount been
recorded?
The unit may bread down or the components
may be burned out
The unit may bread down or the components
may be burned out
It is not easy to decide the charge amount
of refrigerant.
13
Page 16
U.S. CONTACT INFORMATION
TRADEWINDS, LLC
www.greecomfort.com/resources
E-mail: info@twclimate.com
Contractor Support 888-850-7928 | Mon–Fri 8AM-5PM EDT