SUPERIOR DESIGNS PROVIDE EASY SOLUTIONS TO COMPLEX PROBLEMS
GREE Ductless Multi Zone systems provide quiet comfort and energy ecient heating and cooling in up to
five dierent rooms – without ductwork. For most residential and light commercial applications, this is the ideal
solution to balance comfort, eciency and ease of installation. This Inverter-driven system oers Seasonal
Energy Eciency Ratings (SEER) up to 16. With individual room control and variable speed compressor
operation, comfort is boosted throughout your home or oce, while utility bills are held in check.
Gree’s exclusive G-10 Inverter technology powers the twin rotary compressor inside the Multi Zone
outdoor compressor section. The G-10 Inverter constantly adjusts the compressor speed to maintain
a comfortable room temperature. This saves energy, reduces outdoor noise and maintains a steady
room temperature by eliminating the harsh starts and stops of conventional systems.
When laying out a new project, you’ll appreciate the flexibility of Gree’s Multi Zone Systems. A single outdoor unit
can simultaneously power up to five indoor units while eliminating expensive ductwork. Without those ducts, your
installation is simpler, faster and more cost-eective. And the flexibility doesn’t stop there, as you can also mix
and match your choice of Wall Mount, Ceiling Cassette, Concealed Duct, Universal Floor/Ceiling and Mini Floor
Console indoor units to create a unique heating and cooling system to perfectly fit any project.
No pipe sweating
No sweating is needed for the pipe connection
between the indoor and outdoor units. All
piping connections are flared to simplify and
ease the piping installation.
Simple Wiring
No special or hard-to-find communication
wire is needed between the indoor and
outdoor units. The system uses common
14-4 AWG stranded copper THHN 600V
wire. The system’s communication is ready
as soon as the electrical wiring between the
indoor and outdoor units is complete.
High Lift Design
Gree’s High Lift design allows for extended
piping length, up to 262 feet total, as well as
50 feet of vertical lift from the condensing
units. This allows for greater flexibility in the
layout of the system.
Outdoor Unit
Power
Supply
1st Branching
Section
Indoor Unit
Transmission System
From Outdoor Unit to
the Indoor Unit:
82ft
82ft
Between Indoor Units:
Height Dierence
50ft
and Outdoor Unit:
50ft
Between Indoor Unit
Height Dierence
Allows up to 262 feet of pipe length
Energy Saving
Multi Zone systems allow each room to be individually controlled. Only those rooms requiring air
conditioning (or heating) are cooled (or heated), and all of it is accomplished without ductwork.
In addition, Gree’s G-10 inverter technology reduces energy waste, maximizes eciency and
achieves up to 16 SEER.
2
PRODUCT OVERVIEW
Self-Diagnostics System
Each indoor and outdoor unit continuously runs
a series of multi-point diagnostic tests on the
system, to automatically scan for unacceptable
operating conditions or malfunctions. If such
conditions occur, the system takes corrective
action or stops. The fault code will be shown
on the indoor, outdoor and wired controller displays.
Problems and system status are displayed with
comprehensive diagnostic codes to simplify system
troubleshooting and shorten repair times.
Flexible Design
Gree’s Multi Zone systems have many advantages
for both the property owner and the installer.
Up to five indoor units, powered by a single
outdoor unit, results in flexible zoning solutions
for almost any application. Various styles of
indoor units may be mixed and matched in any
combination to create a unique, multiple zone
heating and cooling system. Choose from Wall
Mount, Ceiling Cassette, Slim Duct, Universal
Floor/Ceiling and Mini Floor Console indoor units.
All are lightweight and compact enough to be
installed on the wall or in any ceiling space.
Diagnostic
Code
E1
E2
E3
E4
E5
E6
E7
E9
F4
Malfunction
Compressor High Pressure Protection
Indoor Coil Anti-Freeze Protection
Low Pressure Protection
High Discharge Temperature Protection
Compressor High Temperature Protection
Indoor/Outdoor Communication Failure
Heating & Cooling Modes Conflict
Condensate Water Too High
Outdoor Coil Sensor Failure
One outdoor unit
can power up to
5 indoor units.
Intelligent Control
Gree’s Multi Zone components use state-of-the
art intelligent controls to generate the ultimate
in room comfort. G-10 Inverter technology
delivers the exact level of required capacity (from
10% to 100%) to maintain room temperature and
humidity in the comfort range. The optimized PID
controls maintain the room temperature within
less than ±1.0°F of the room setpoint temperature.
The result is a virtually constant room temperature
without the typical fluctuations that occur with a
conventional fixed speed ON/OFF system.
Ductless Saves Money
Realize energy savings by eliminating heat loss
from inecient and leaky ductwork. The average
ducted air distribution system could reduce
overall system eciency by up to 30 percent.
Eliminating ductwork allows you to downsize
equipment while upsizing performance.
Cooling
Gree Inverter Control System
Conventional Fixed Speed System
Room temp.
3
Wired Tether Controller
REFERENCE TABLE
INDOOR UNIT
NEO WALL MOUNT XK-41 MC207059
CEILING CASSETTE XK-19 MC20700140
SLIM CONCEALED DUCT XK-19 MC20700140
UNIVERSAL FLOOR CEILING XK-19 MC20700140
MINI-FLOOR CONSOLE XK-19 MC20700140
TYPEPART NUMBER
TETHER CONTROLLER
FEATURES AND BENEFITS
Attractive Appearance
The XK series features a sleek, unobtrusive design that fits seamlessly into any décor.
Easy To Install
The XK series Wired Tether Controllers have been designed for fast and easy installation to save you
time and money. Each XK wired controller comes with keyed connectors and 26 feet of cable. Its
flexible design allows it to be mounted either flush to the wall or using an electrical box.
Command Center
Enjoy the convenience of a fully functional command center with a large LCD display to set up and
operate your duct free system. The XK series allows you fast and easy access to a large number of
system features and functions:
Note: Some indoor units may not support specific system features or functions. Always refer to the
indoor unit Owner’s Manual.
On/O
The XK series allows you to start and stop your system. The system will always start up in the last operating mode with the last room setpoint.
Operating Mode
The system allows users to eortlessly select an operating mode (Cooling, Heating, Dry,
Fan Only or Auto mode) with a single key stroke.
4
FEATURES AND BENEFITS
Command Center (cont.)
Fan Speed
The system fan speed (High, Medium, Low or Auto) can be adjusted for peak room comfort
and quietness.
Room Setpoint
The XK series makes dialing in the correct room setpoint temperature a breeze. Most indoor
units allow a room setpoint from 61° F to 86° F (16° to 30° C).
Timer ModeWhen needed, the XK series allows you the ability to program a time period (one-half to
24 hours) to which your system will automatically turn ON or OFF.
Sleep Mode
The XK series will automatically adjust room temperature during your sleep time. This slight
change in temperature will not aect your comfort level due to the natural eects that
sleeping has on the body, but it will save on energy consumption and will lower electric bills.
Turbo ModeWhether you need to heat up or cool down a room quickly, Turbo Mode will force your system
to run at higher speeds to reach the desired room temperature faster.
X-Fan Mode
The X-Fan function can be activated from the XK series to remove moisture buildup when the
system is turned OFF. This helps prevent mold and mildew growth on your indoor coil and fan.
Privacy LockThe XK series has a Privacy Lock that can be set to prevent unauthorized access to the unit controls and prevents tampering with system settings.
Power Failure RecoveryPower interruptions are no problem for the XK series wired controller. All user selections and system parameters are stored in non-volatile memory. When power is returned, the system
will automatically return to the last operating mode.
Swing Louver ControlThe XK series provides control over the motorized discharge air louver to optimize air distribution
throughout the room.
Fahrenheit or Celsius DisplayWhether you are more comfortable reading temperatures in Fahrenheit or Celsius, the
XK series can quickly be set up to display either one.
Diagnostic CenterThe system has an on-board computer that continuously scans for unacceptable operating
conditions or malfunctions. If such conditions occur, the system takes corrective action or
stops. The fault or status codes will be shown on XK series wired tether controller display
to facilitate easy troubleshooting and repair.
5
Wired Tether Controller
DIMENSIONAL SPECIFICATIONS
AC
BB
TYPEPART NUMBER
XK-41 MC207059 3.625 (92) 3.625 (92) 1.375 (35)
XK-19 MC20700140 3.625 (92) 3.625 (92) 1.375 (35)
A
in (mm)
B
in (mm)
C
in (mm)
SYSTEM WIRING DIAGRAM
6
INSTALLATION
The following is a brief XK-19 and XK-41 Wired Tether
Controller installation overview. See Wired Controller
Installation Manual for more detailed instructions on
installation, start-up, and setup.
Connecting Indoor Unit
Select a proper location on the wall for mounting
the Tether Controller. Install switch box, if required
by code. Locate the 26-ft communication cable that
came with the Tether Controller. Run communication
cable (as desired) between indoor unit and selected
wall mounting location. Locate the Tether Controller
connector in the control box area of the indoor unit.
Carefully connect communication cable to indoor unit.
Wired Tether Controller Installation
Pull communication cable through switch box (if
one is used) and Wired Tether Controller backplate.
Securely fasten backplate to the switch box or wall.
Carefully connect communication cable to rear of
Wired Tether Controller panel. Push extra cable into
wall and secure controller panel to backplate mounted
on the wall.
NOTE: Do not cut and splice communication cable.
Follow the start-up setup instructions supplied with
the Wired Tether Controller.
7
Limited Warranty Statement
DUCTLESS HEAT PUMP MULTI-SPLIT SYSTEMS
Eective on new GREE Ductless purchases on or after March 1, 2013
GREE distributor (hereinafter “Company”) warrants this product against failure due to defect in
materials or workmanship under normal use and maintenance as follows. All warranty periods
begin on the date of original installation. If the date cannot be verified, the warranty period begins
one hundred twenty (120) days from date of manufacture. If a part fails due to defect during the
applicable warranty period Company will provide a new or remanufactured part, at Company’s
option, to replace the failed defective part at no charge for the part. This limited warranty is
subject to all provisions, conditions, limitations and exclusions listed below.
• A warranty period of Seven (7) years on compressor to the original registered end user.
• A warranty period of Five (5) years on all parts to the original registered end user.
• A warranty period of One (1) year on the remote control provided with the original unit.
• Limited warranty applies only to systems that are properly installed by a state certied
or licensed HVAC contractor, under applicable local and state law in accordance with all
applicable building codes and permits; GREE installation and operation instructions and
good trade practices.
• Warranty applies only to products remaining in their original installation location.
• Defective parts must be returned to the distributor through a registered servicing dealer
for credit.
8
LIMITATIONS OF WARRANTIES
All implied warranties and/or conditions (including implied warranties or conditions of
merchantability and fitness for a particular use or purpose) are limited to the duration of this
limited warranty, some states or provinces do not allow limitations on how long an implied
warranty or condition lasts, so the above may not apply to you. The express warranties made
in this warranty are exclusive and may not be altered, enlarged, or changed by any distributor,
dealer, or other person, whatsoever.
THIS WARRANTY DOES NOT COVER:
1. Labor or other costs incurred for diagnosing, repairing, removing, installing, shipping, servicing
or handling of either defective parts, or replacement parts, or new units.
2. Product cleaning required prior to warranty service and repair.
3. Normal maintenance as outlined in the installation and servicing instructions or Owner’s
Manual, including filter cleaning and/or replacement and lubrication.
4. Failure, damage or repairs due to faulty installation, misapplication, abuse, improper servicing,
unauthorized alteration or improper operation.
5. Failure to start due to voltage conditions, blown fuses, open circuit breakers, or damages due
to the inadequacy or interruption of electrical service.
6. Failure or damage due to floods, winds, fires, lightning, accidents, corrosive environments
(rust, etc.) or other conditions beyond the control of the Company.
7. Failure or damage of coils or piping due to corrosion on installations within one (1) mile of
sea coast or corrosive body.
8. Parts not supplied or designated by Company, or damages resulting from their use.
9. Products installed outside continental USA and Canada.
10. Electricity or fuel costs, or increases in electricity or fuel costs for any reason whatsoever,
including additional or unusual use of supplemental electric heat.
11. Any cost to replace, refill or dispose of refrigerant, including the cost of refrigerant.
12. Shipping damage or damage as a result of transporting the unit.
13. Accessories such as condensate pumps, line sets and so forth are not covered.
14.
Any special, indirect or consequential property or commercial damage of any nature whatsoever.
Some states or provinces do not allow the exclusion of incidental or consequential damages,
so the above limitation may not apply to you.
FOR WARRANTY SERVICE OR REPAIR:
Contact your installing contractor. You may find the installer’s name on the equipment or in
your Owner’s packet.
This warranty gives you specific legal rights, and you may also have other
rights which vary from state to state or province to province.
WSO021513-DLSWARR-MULTI – Rev. 10-15-14
9
Specifications in this booklet are subject to change without notice.
Manufacturer reserves the right to discontinue or modify specifications or
designs without notice or without incurring obligations. All rights reserved.