Gree GWH09MB-D3DNA8D, GWH09MB-D3DNA3I, GWH09MB-D3DNA8I, GWH12MB-D3DNA3D, GWH12MB-D3DNA8D Owner's Manual

...
Change for Life
Split Air Conditioner
Owner's Manual Residential Air Conditioners
Thank you for choosing Residential Air Conditioners,please read this owner’s
manual carefully before operation and retain it for future reference.
GW
GWH09MB-D3DNA8D/I GWH12MB-D3DNA8D/I GWH12MB-D3DNA2D/I
H18MC-D3DNA2D/I
Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
CONTENTS
Operation and maintenance
Notices for operation ...................................................................... 1
Notices for use ............................................................................... 3
Names and functions of each part ................................................. 4
Operation of wireless remote control ............................................. 5
Clean and care .............................................................................. 11
Troubleshooting ............................................................................. 13
Installation service
Notices for installation ................................................................... 16
Installation dimension diagram ...................................................... 18
Install indoor unit ........................................................................... 19
Check after installation and test operation .................................... 22
Emergency operation .................................................................... 10
Installation and Maintenance of Healthy Filter .............................. 23
Never attempt.
Be sure to follow this instruction
The physical product may differ from the drawing in this manual for different display. If there are some differences between them, please refer to the physical product as the standard.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure they are away from the appliance.
1
The power supply
must adopt the
special circuit that with air switch protection and assure
Keep combustilble
spray away from the
units more than 1m.
Don't block the air intake or outlet vents
of both the outdoor and indoor units.
It can decrease the air conditioning capacity or cause a malfunction.
Don’t leave windows and doors open for
a long time while operating the air conditioner.
It can decrease the air conditioning capacity.
It can cause a fire or explosion
Don’t attempt to repair the air
conditioner by yourself.
The wrong repair will lead to an electric shock or fire, so you should contact the service center to repair.
Be sure to pull out the power plug as
the air conditioner not in use
for a long time.
Otherwise, the accumulated dusts that may cause over heating or fire.
Never splice the power cord or use
an extended cord.
It can cause overheating or fire.
When having a
burning smell or
smoke, please turn off the power supply and contact with the service center.
If the abnormity still exists, the unit may be damaged, and may cause electric shock or fire.
Please read the following carefully before operating
Notices for operation
components would be easily damaged, when the voltage is very low, the compressor vibrates terribly and that the refrigerant system will be damaged, the compressor and electric components cannot work, the voltage should be stable; there shouldn’t be big fluctuation.
When the voltage is very high, the
it has enough capacity. The unit will be turned on or off according to your requirement automatically, please do not turn on or turn off the unit frequently, other­wise disadvantage effect may be caused to the unit.
2
Notices for operation
Don’t apply the cold wind to the body for a long time.
It can cause the health problems.
Splashing water on the air conditioner can cause an electric
shock and malfunction.
Don’t place a space heater near the air conditioner.
Don’t blow the wind to animals and plants directly. It can cause
a bad influence to them.
Don’t insert your hands or stick into the air intake or outlet vents.
Don’t use the air conditioner for other purposes, such as
drying clothes, preserving foods, etc.
To adjust the airflow direction
appropriately. When operating the unit, to adjust the vertical and lateral air flow direction by use of remote controller.
Swing louver
Guide louver
Please don't cut off or damage the
power cords and control cords. If they are damaged, please ask the qualified personnel to change them.
3
Notices for use
Working principle and special functions for cooling
Principle:
Air conditioner absorbs heat in the room and transmit to outdoor and discharged, so that indoor ambient temperature decreased, its cooling capacity will increase or decrease by outdoor ambient temperature.
Anti-freezing function:
If the unit is running in COOL mode and in low temperature, there will be frost formed on the heat exchanger, when indoor heat exchanger temperature decreased below 0
the indoor unit microcomputer will stop compressor running and protect the unit.
Principle:
Working principle and special functions for heating
*
Air conditioner absorbs heat in the room and transmit to outdoor and discharged, will increase, its heating capacity will decrease by outdoor ambient temperature. so that indoor ambient temperature increased, so room heating capacity.
*
If outdoor temperature got lower, please operate with the other heating ventilating equipments.
Defrosting:
*
When outdoor temperature is low but high humidity, after a long while running, frost will form on outdoor unit, that will effect the heating effect, at this time, the auto defrosting function will act, the heat running will stop for 8-10mins.
*
During the auto defrosting, the fan motors of indoor unit and outdoor unit will stop.
*
During the defrosting, the indoor indicator flashes, the outdoor unit may emit vapor. This is due to the defrosting, it isn't malfunction.
*
After defrosting finished, the heating will recover automatically.
Anti-freezing function:
In "HEAT" mode, if in the following status, the indoor heat exchanger haven't achieve
the certain temperature, that the indoor unit will not act, in order to prevent cool air
blowing. (Within 3mins)
1. Heating starts.
The climate type of this unit is according to the nameplate.
2. After Auto defrosting finished.
3. Heating under the low temperature.
4
Names and functions of each part
Indoor unit
Front panel
Filter
Guide louver
Wall pipe
Bind tape
Connection pipe
Drainage pipe
Remote control
Air in
Air out
Press this button to select LIGHT on or off
in the displayer. When the LIGHT on is
LIGHT button
LIGHT
set, the icon will be displayed and the
indicator light in the displayer will be on.
When the LIGHT off is set, the icon will
be displayed and the indicator light in the
displayer will be off.
Names and functions of wireless remote control
ON/OFF button
ON/OFF
Remote control
Signal transmitter
AUTO
COOL
DRY
FAN
HEAT
(
only for cooling and heating unit. As for cooling only unit, it won’t have any action when it receives the signal of heating operation.)
Don't drop or throw the remote control; Don't let any liquid in the remote control and
Note: Be sure that there are no obstructions between receiver and remote controller;
Middle fan
put the remote control directly under the sunlight or any place where is very hot.
Press this button, Auto, Cool, Dry, Fan,
Heat mode can be selected circularly.
MODE button
MODE
Auto mode is default while power on.
Under Auto mode, the temperature will not
be displayed; Under Heat mode, the initial value is 28 (82 modes, the initial value is 25(77
.
Press this button, Sleep On and Sleep Off can be selected. After powered on, Sleep
SLEEP button
SLEEP
Off is defaulted. After the unit is turned off, the Sleep function is canceled. After Sleep function set up, the signal of Sleep will display. In this mode, the time of timer can be adjusted. Under Fan and Auto modes, this function is not available.
Press this button, Auto, Low, Middle, High
speed can be circularly selected. After
FAN button
FAN
powered on, Auto fan speed is default.
Low fan
High fan
Press this button, the clock can be set up,
signal blink and display. Within 5
CLOCK button
CLOCK
seconds, the value can be adjusted by pressing + or - button, if continuously press this button for 2 seconds above, in every 0.5 seconds, the value on ten place of Minute will be increased 1. During blinking, repress the Clock button, signal will be constantly displayed and it denotes the setting succeeded. After powered on, 12:00 is defaulted to display and signal will be displayed. If there is signal be
value is Clock value, otherwise is Timer value.
displayed that denotes the current time
Operation of wireless remote control
o
F); Under other
o
F)
Press this button, the unit will be turned on, press it once more, the unit will be turned
off. When turning on or turning off the unit,
the Timer, Sleep function will be canceled, but the presetting time is still remained.
adjustable, low fan speed is imperative,
Note: Under the Dry mode, the fan speed isn't
wireless adjustable, low fan speed is imperative,
but when operating this button, the
5
AUTO
Remote control
X-FAN button
X-FAN
+ button
+
Presetting temperature can be decreased. Press this button, the temperature can be
- button
-
set up, continuously press this button and hold for two seconds, the relative contents can quickly change, until unhold
this button and send the order that the (
o
F) signal will be displayed all the time. The temperature adjustment is unav­ailable under the Auto mode, but the order can be sent by if pressing this button.
Names and functions of wireless remote control
Operation of wireless remote control
Press this button, can turn on or turn off the drying. In Cool and Dehumidifying mode,
this button, " " will be concealed, at this time the X-FAN function is turned off. After powered on, X-FAN OFF is defaulted. When operating the ON/OFF button, or switching mode to Cool or Dehumidifying mode, the X-FAN function will keep the original status. If unit is turned off, X-FAN OFF only can be set up and send the signal. In Auto, Fan as well as Heat mode, X-FAN function can not be set up and there is no " " displaying.
Note: X-FAN is the alternative expression
of BLOW for the purpose of understanding.
press this button and will display " ", at this time the X-FAN is turned on. If repress
In Cool or Heat mode, press this button can turn on or turn off the Turbo function. After turned on the Turbo function, its signal will be displayed. When switching the mode or changing fan speed, this function will be canceled automatically.
For presetting temperature increasing. Press this button, can set up the temperature, when unit is on. Continuously
press and hold this button for more than 2 seconds, the corresponding contents will be changed
rapidly, until unpress the button
℃(℉)
laying all along. In Auto mode, the temp­erature can not be set up, but operate this button can send the signal. Centigrade setting range: 16-30; Fahrenheit scale setting range 61-86.
then send the information, is disp-
with multifunction; For some function, which the model dosen't have, if press the corresponding button on the remote controller that the unit will keep the original running
status.
Notice: This is a general use remote controller, it could be used for the air conditioners
6
Press this button, could select displaying the indoor setting temperature or indoor ambient temperature. When the indoor unit firstly power on it will display the setting temperature, if the temperature's displaying status is changed from other status to " ", displays the ambient temperature, 5s later or within 5s, it receives other remote control signal that will return to display the setting temperature. if the users haven't set up the temperature displaying status, that will display the setting temperature.
After powered on, the setting temperature displaying is defaulted, (according to customers requirements to display, if there is no requirement that will default to display the presetting temperature and there is no icon displayed on wireless remote control). Press this button, (When displaying ) , will display presetting temperature; (when displaying ) will display indoor ambient temperature,
TEMP button
TEMP
current displaying status will not be changed. If current displays indoor ambient temperature, if received the other remote control signal, it will display presetting temperature, 5s later, will back to display the ambient temperature. (This function is applicable to partial of models)
(This function is applicable to partial of models)
TURBO button
TURBO
Loading...