Configuration of connection pipe and additional volume of refrigerant
...26
This symbol stands for the items
should be forbidden.
The products in this manual may be different with the real one, according to different
models, some models have displayer and some models without displayer, the position
and shape of the displayer please refer to the real one.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of the appliance
by a person responsible for their safety.
Children should be supervised to ensure they are away from the appliance.
Do not dispose this product as unsorted municipal waste.
Collection of such waste separately for special treatment
is necessary.
This symbol stands for the items
should be followed
Operation and maintenance-notices for operation
Earth: The ground
★
be connected!
If not, please ask the qualified personnel to install. Furthermore, don't conn-
ect each wire to the gas pipe, water
pipe, drainage pipe or any other impr-
oper places.
Be sure to pull out the power
★
plug when not using the air
co
nditioner for a long time.
Otherwise, the accumulated dust
may cause fire or electric shock.
★
Select the most appropriate
temperature.
Keep room cooler than outside
about 5 degree.
It can preclude the electricity wasted.
Don't leave windows and
★
doors open for a long time
while operating the air
conditioner.
It can decrease the air conditioning
capacity.
Please note whether the
★
installed stand is firm
enough or not.
If it is damaged, it may lead to
the fall of the unit and cause
the injury.
Don't block the air intake or
★
outlet vents of both the
outdoor and indoor units.
It can decrease the air conditioning
capacity or cause a malfunction.
Don't step on the top of the
★
outdoor unit or place something on it.
As falling off the outdoor unit
can be dangerous.
Keep combustible spray
★
away from the units more
than 1m.
It can cause afire or explosion.
Don't attempt to repair
★
the air conditioner by
yourself.
The wrong repair will lead to
an electric shock or fire, so
you should contact the service
center to repair.
-1-
Notices for operation
If the supply cord is damaged, it must be replaced
★
by the manufacturer or its service agent or a
similarly qualified person in order to avoid a
hazard.
The airflow direction can be adjusted appro-
★
priately. At operating, adjust the vertical airflow
direction by adjusting the louvers of upward/downward direction. And then, hold two ends of
left and right louver to adjust the horizontal airflow.
Don't insert your hands or stick into the air
★
intake or outlet vents.
Otherwise it will cause accident.
Don't apply the cold wind to the body for a
★
long time.
It can cause the health problems.
★
Splashing water on the air conditioner can
cause an electric shock and malfunction.
Louver of left/right direction Louver of upward/
Don't blow the wind to animals and plants
★
directly. It can cause a bad influence to them.
Don't use the air conditioner for other purposes,
★
such as drying clothes, preserving foods, etc.
★
Don't place a space heater near the air
conditioner.
downward direction.
Or CO toxicosis may occur for imcomplete
burning.
-2-
Notices for use
Working principle and special functions for cooling
Principle:
Air conditioner absorbs heat in the room and transmit to outdoor and discharged, so that
indoor ambient temperature decreased, its cooling capacity will increase or decrease by
outdoor ambient temperature.
Anti-freezing function:
If the unit is running in COOL mode and in low temperature, there will be frost formed on
the heat exchanger, when indoor heat exchanger temperature decreased below 0 , the
indoor unit microcomputer will stop compressor running and protect the unit.
Working principle and special functions for heating
Principle:
Air conditioner absorbs heat from outdoor and transmits to indoor, in this way to increase
*
room temperature. This is the heat pump heating principle, its heating capacity will be
reduced due to outdoor temperature decrease.
If outdoor temperature becomes very low, please operate with other heating equipments.
*
Defrosting:
When outdoor temperature is low but high humidity, after a long while running, frost will
*
form on outdoor unit, that will effect the heating effect, at this time, the auto defrosting
function will act, the heat running will stop for 3-12 mins.
During the auto defrosting, the fan motors of indoor unit and outdoor unit will stop.
*
During the defrosting, the indoor indicator flashes, the outdoor unit may emit vapor.
*
This is due to the defrosting, it isn't malfunction.
After defrosting finished,the heating will recover automatically.
*
℃
Anti-cool wind function:
In "Heat" mode, under the following three kinds of state, if indoor heat exchanger doesn't
arrive at certain temp., indoor fan will not act, in order to prevent cool wind blowing(within
2 mins):
1. Heating starts. 2. After Auto Defrost finished. 3. Heating under the low temperature.
-3-
Notices for use
Working temperature range
Indoor sideDB/WB(oC)
Maximum cooling
Maximum heating
The operating temperature range (outdoor temperature) for cooling only unit is 18℃~ 43℃;
for heat pump unit is -7℃~ 43℃.
32/23
27/---
Outdoor sideDB/WB(oC)
43/26
24/18
-4-
Names and functions of each part
Indoor unit
⑶
⑷
SET TEMP/
AMBIENT TEMP
Cool
Heat
ON/OFF
Outdoor unit
⑸
Air in
Air in
Air out
⑵
Wireless
Dry
remote control
Power
Receive window
⑴
⑹
⑺
Power cable
⑴
Remote control
⑵
Front panel
⑶
Filter
⑷
Guide louver
⑸
Wall pipe
⑹
⑺
Bind tape
Drainage pipe
⑻
Air out
⑻
-5-
Operation of Remote Controller
1
ON/OFF
Press it to start or stop
2
MODE
Press it to select operation mode
operation.
(AUTO/COOL/DRY/FAN/HEAT).
1
5
7
9
12
FAN
AIR
HUMIDITY
FILTER
TURBO
ON/OFF
FAN
10
X-FAN
13
TURBO
AUTO
HEALTH
TEMP
SLEEP
OPER
X-FAN
HOUR
ON/OFF
MODE
TIMER
LIGHT
3
: Press it to decrease temperature
-
setting.
4
+
: Press it to increase temperature
setting.
5
FA
N
Press it to set fan speed.
2
6
Press it to set up & down swing angle.
43
7
HEALTH SAVE
( page 9)
Press it to turn on or off health function.
6
8
8
11
14
Press it to set left & right swing angle.
9
X-FAN ( page 9)
10
TEMP( page 9)
11
TIMER
Press it to set timer ON/ timer OFF.
12
TURBO( page 9)
13
SLEEP( page 10)
14
LIGHT
Press it to turn on/off the light.
-6-
19
Operation of Remote Controller
16
17
18
15
MODE icon:
If MODE button is pressed,
current operation mode icon
(AUTO), ( COOL),
(DRY), (FAN) or (HEAT
only for heat pump models) will
show.
16
LOCK icon:
is displayed by pressing "+"
and “-” buttons simultaneously. Press
them again to clear the display.
17
LIGHT icon:
is displayed by pressing the
LIGHT button. Press LIGHT button
again to clear the display.
18
SLEEP icon :
is displayed by pressing
the SLEEP button. Press this
button again to clear the display.
19
TEMP icon:
Pressing TEMP button,
(set temperature),
ambient temperature)
(outdoor ambient temperature)
and blank is displayed circularly.
(indoor
AUTO
FAN
HEALTH
AIR
HUMIDITY
FILTER
TURBO
191520
20
21
22
23
24
24
OPER
X-FAN
23
HOUR
ON/OFF
22
21
Up & down swing icon:
is displayed when pressing
the
up & down swing
button.
Press this button again to clear the
display.
Left & right swing icon:
is displayed when pressing the
left & right swing
button.Press this
button again to clear the display.
SET TIME display:
After pressing TIMER button,
ON or OFF will blink.This area
will show the set time.
DIGITAL display:
This area will show the set temperature. In SAVE mode,"SE" will be
displayed. During defrosting opera tion, “H1” will be displayed.
FAN SPEED display:
Press FAN button to select the
desired fan speed setting(AUTO-
Low-Med-High).Your selection will
be displayed in the LCD windows,
except the AUTO fan speed.
-7-
Loading...
+ 21 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.