Gree GWC18KG-K3DNA5B, GWH18KG-K3DNA5B, GWH18KG-K3DNA6A, GWC18KG-K3DNA8A, GWH18KG-K3DNA8A Owner's Manual

...
Change for Life
Split Air Conditioner
Owner's Manual Residential Air Conditioners
Thank you for choosing Residential Air Conditioners,please read this owner
’s
GWC18KG-K3DNA5A GWC18KG-K3DNA8A GWH18KG-K3DNA8A
GWC18KG-K3DNA5B GWH18KG-K3DNA6A
GWH18KG-K3DNA5B GWH18KG-K3DNA7B GWC18KG-K3DNA5D GWH18KG-K3DNA7B GWH18KG-K3DNA6B GWH18KG-K3DNA9B GWH18KG-K3DNB2B
GWC18KG-K3DNA6A GWH18KG-K3DNB1B GWH18KG-K3DNA9A GWC18KG-K3DNA9A GWC18KG-D3DNA7A GWC18KG-K3DNA7A GWH18KG-K3DNB3A GWH24KG-K3DNB3B GWC18KG-D3DNA5A GWC18KG-K3DNB2A GWH18KG-K3DNA6E GWC18KG-D3DNA5D GWH18KG-K3DNA9E
GWC18KG-K3DNB2E GWC18KG-K3DNA9E
GWH18KG-K3DNA5A GWC24KG-K3DNA5A GWH24KG-K3DNA5A
GWC24KG-K3DNA8A GWH24KG-K3DNA8A
GWH24KG-K3DNA5B GWH24KG-K3DNA6A GWC24KG-K3DNA7A GWH24KG-K3DNA7A GWH24KG-K3DNA6B GWH24KG-K3DNA9B GWC24KG-K3DNA6A
GWC24KG-K3DNA5D GWH24KG-K3DNB1B GWC24KG-D3DNA7A GWC24KG-K3DNA9A GWH24KG-K3DNA9A GWH24KG-K3DNB2B GWH18KG-K3DNA5E GWC18KG-K3DNA5E GWH18KG-D3DNA5A GWC18KG-K3DNA5F GWC24KG-K3DNB2A GWH18KG-D3DNA5D GWC18KG-K3DNA5G GWC18KG-D3DNA6E
CONTENTS
This symbol stands for the items should be forbidden.
This symbol stands for the items should be followed
..................................1
................................11
....................................14
..........................19
■ ...................................20
■ ..................................23
..................24
...............25
................................17
....................................12
Operation and maintenance
Notices for operation
Notices for use
......................................3
Names and functions of each part
......................... 5
Operation of remote controller
.............................6
Clean and care
Troubleshooting
Installation service
Notices for installation
Installation dimension diagram
Install indoor unit
Install outdoor unit
Check after installation and test operation
Emergency operation
Installation and Maintenance of Healthy Filter
Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
The products in this manual may be different with the real one, according to different models, some models have displayer and some models without displayer, the position and shape of the displayer please refer to the real one.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure they are away from the appliance.
Configuration of connection pipe and additional volume of refrigerant
...26
Operation and maintenance-notices for operation
-1-
Be sure to pull out the power
Earth: The ground be connected!
If not, please ask the qualified person­nel to install. Furthermore, don't conn-
ect each wire to the gas pipe, water pipe, drainage pipe or any other impr-
oper places.
plug when not using the air co
nditioner for a long time.
Otherwise, the accumulated dust may cause fire or electric shock.
Select the most appropriate temperature.
Keep room cool­er than outside about 5 degree.
It can preclude the electricity wasted.
Don't leave windows and doors open for a long time while operating the air conditioner.
It can decrease the air conditioning capacity.
Don't block the air intake or outlet vents of both the outdoor and indoor units.
It can decrease the air conditioning capacity or cause a malfunction.
Keep combustible spray away from the units more than 1m.
It can cause afire or explosion.
If it is damaged, it may lead to the fall of the unit and cause the injury.
Please note whether the installed stand is firm enough or not.
Don't step on the top of the outdoor unit or place some-
thing on it.
As falling off the outdoor unit can be dangerous.
Don't attempt to repair the air conditioner by
yourself.
The wrong repair will lead to an electric shock or fire, so you should contact the service center to repair.
-2-
Notices for operation
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a
similarly qualified person in order to avoid a hazard.
The airflow direction can be adjusted appro­priately. At operating, adjust the vertical airflow direction by adjusting the louvers of upward/do­wnward direction. And then, hold two ends of left and right louver to adjust the horizontal air­flow.
Louver of left/right direction Louver of upward/
downward direction.
Don't insert your hands or stick into the air intake or outlet vents.
Otherwise it will cause accident.
Don't blow the wind to animals and plants directly. It can cause a bad influence to them.
Don't apply the cold wind to the body for a long time.
It can cause the health problems.
Don't use the air conditioner for other purposes, such as drying clothes, preserving foods, etc.
Splashing water on the air conditioner can
cause an electric shock and malfunction.
Don't place a space heater near the air conditioner.
Or CO toxicosis may occur for imcomplete burning.
Anti-cool wind function:
In "Heat" mode, under the following three kinds of state, if indoor heat exchanger doesn't arrive at certain temp., indoor fan will not act, in order to prevent cool wind blowing(within 2 mins):
1. Heating starts. 2. After Auto Defrost finished. 3. Heating under the low temperature.
*
*
*
*
*
*
Notices for use
Working principle and special functions for cooling
Principle:
Anti-freezing function:
Working principle and special functions for heating
Principle:
Defrosting:
Air conditioner absorbs heat in the room and transmit to outdoor and discharged, so that indoor ambient temperature decreased, its cooling capacity will increase or decrease by outdoor ambient temperature.
If the unit is running in COOL mode and in low temperature, there will be frost formed on the heat exchanger, when indoor heat exchanger temperature decreased below 0 , the indoor unit microcomputer will stop compressor running and protect the unit.
Air conditioner absorbs heat from outdoor and transmits to indoor, in this way to increase room temperature. This is the heat pump heating principle, its heating capacity will be
reduced due to outdoor temperature decrease. If outdoor temperature becomes very low, please operate with other heating equipments.
When outdoor temperature is low but high humidity, after a long while running, frost will form on outdoor unit, that will effect the heating effect, at this time, the auto defrosting
function will act, the heat running will stop for 3-12 mins.
During the auto defrosting, the fan motors of indoor unit and outdoor unit will stop.
During the defrosting, the indoor indicator flashes, the outdoor unit may emit vapor. This is due to the defrosting, it isn't malfunction.
After defrosting finished,the heating will recover automatically.
-3-
-4-
Notices for use
Working temperature range
Maximum cooling
Maximum heating
Indoor sideDB/WB(oC)
Outdoor sideDB/WB(oC)
32/23
27/---
43/26
24/18
The operating temperature range (outdoor temperature) for cooling only unit is 18~ 43; for heat pump unit is -7~ 43.
Air in
Air out
Names and functions of each part
Indoor unit
Air out
Outdoor unit
Wireless
remote control
Air in
Power cable
Remote control
Front panel
Filter
Guide louver
Wall pipe
Bind tape
Drainage pipe
Receive window
Heat
Cool
Power
Dry
ON/OFF
-5-
SET TEMP/
AMBIENT TEMP
-6-
FAN
AUTO
OPER
HEALTH
AIR
FILTER
TURBO
ON/OFF
X-FAN
HOUR
HUMIDITY
ON/OFF
MODE
FAN
X-FAN
TURBO
TEMP
TIMER
SLEEP
LIGHT
2
11
7
10
13
9
43
12
8
6
14
5
1
Press it to start or stop
ON/OFF
operation.
MODE
+
-
Press it to select operation mode
(AUTO/COOL/DRY/FAN/HEAT).
: Press it to increase temperature
setting.
: Press it to decrease temperature
setting.
FA
HEALTH SAVE
N
Press it to set up & down swing angle.
Press it to turn on/off the light.
TIMER
X-FAN ( page 9)
( page 9)
TEMP( page 9)
TURBO( page 9)
SLEEP( page 10)
LIGHT
Press it to set fan speed.
Press it to set timer ON/ timer OFF.
1
2
Press it to turn on or off health function.
7
4
3
5
6
Press it to set left & right swing angle.
8
11
9
10
12
13
14
Operation of Remote Controller
Operation of Remote Controller
LOCK icon:
MODE icon:
LIGHT icon:
If MODE button is pressed, current operation mode icon
Pressing TEMP button,
(set temperature),
ambient temperature) (outdoor ambient temperature) and blank is displayed circularly.
(indoor
is displayed by pressing "+" and “-” buttons simultaneously. Press them again to clear the display.
is displayed when pressing the
left & right swing
button.Press this
button again to clear the display.
is displayed when pressing
the
up & down swing
button.
Press this button again to clear the
display.
is displayed by pressing the LIGHT button. Press LIGHT button again to clear the display.
(AUTO), ( COOL),
(DRY), (FAN) or (HEAT
only for heat pump models) will show.
15
Left & right swing icon:
20
Up & down swing icon:
After pressing TIMER button,
ON or OFF will blink.This area will show the set time.
SET TIME display:
21
This area will show the set tempe­rature. In SAVE mode,"SE" will be
displayed. During defrosting opera­ tion, “H1” will be displayed.
DIGITAL display:
23
Press FAN button to select the desired fan speed setting(AUTO-
Low-Med-High).Your selection will be displayed in the LCD windows, except the AUTO fan speed.
FAN SPEED display:
24
16
17
SLEEP icon :
is displayed by pressing
the SLEEP button. Press this button again to clear the display.
18
TEMP icon:
19
FAN
AUTO
OPER
HEALTH
AIR
FILTER
TURBO
ON/OFF
X-FAN
HOUR
HUMIDITY
191520
18
16
17
21
22
23
24
-7-
22
19
Loading...
+ 21 hidden pages