Gree GWH09KF-D3DNXXA, GWC12KF-D3DNXXA, GWH12KF-D3DNXXA, GWH09KF-A3DNXXA, GWH12KF-A3DNXXA Owner's Manual

...
Change for Life
Split Air Conditioner
Owner's Manual Residential Air Conditioners
Thank you for choosing Residential Air Conditioners,please read this owner’s
manual carefully before operation and retain it for future reference.
MODEL:
GWC09KF-D3DNXXA GWC12KF-D3DNXXA GWH09KF-D3DNXXA GWH12KF-D3DNXXA
GWC09KF-D3DNXXC GWH09KF-D3DNXXC
Note:“XX” stand for different front panels “A1~A9” or “B1~B9” or “C1~C9”
GWC12KF-D3DNXXC GWH12KF-D3DNXXC
CONTENTS
Operation and maintenance
Notices for operation
Notices for use
Names and functions of each part
Operation of remote controller
Emergency operation
..............................................................12
Clean and care
.............................................................14
Troubleshooting
.........................................................1
................................................................3
........................................5
.............................................6
......................................................11
Installation service
Notices for installation
Installation dimension diagram
Install indoor unit
.....................................................17
..........................................20
............................................................21
Install outdoor unit
Check after installation and test operation
...........................24
Installation and Maintenance of Healthy Filter
Configuration of connection pipe and additional volume of refrigerant
This symbol stands for the items should be forbidden.
The products in this manual may be different with the real one, according to different models, some models have displayer and some models without displayer, the position and shape of the displayer please refer to the real one.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance
by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
.........................................................23
......................25
....26
This symbol stands for the items should be followed
Operation and maintenance-notices for operation
Earth: The ground
be connected!
For safety, be sure to turn off the cir-
cuit beaker before
maintenance or cleaning pr
oduct is not used for an extended
period of time.
performing any
or when the
Select the most appropriate tem-
perature.
Keep room cool­er than outside about 5 degree.
If not, please ask the qualified person-
nel to install. Furthermore, don't conn-
ect each wire to the gas pipe, water pipe, drainage pipe or any other impr­oper places.
Don't leave windows and
doors open for a long time while operating the air conditioner.
It can decrease the air conditioning
capacity.
Please note whether the installed
stand is firm enough or not.
it may
Otherwise, the accumulated dust may cause fire or electric shock.
Don't block the air intake or outlet
vents of both the outdoor and indoor units.
It can decrease the air conditioning capacity or cause a malfunction.
Don't step on the top of the
outdoor unit or place something on it.
It can preclude the electricity wasted.
Keep combustible spray away from the units more than 1m.
It can cause afire or explosion.
Don't attempt to repair
the air conditioner by yourself.
If it is damaged, it may lead to the fall of the unit and cause the injury.
As falling off the outdoor unit can be dangerous.
1
The wrong repair will lead to an electric shock or fire, so you should contact the service center to repair.
Notices for operation
If the supply cord is damaged, it must be replaced
by the manufacturer or its service agent or a
similarly qualified person in order to avoid a hazard.
The airflow direction can be adjusted appro-
priately. At operating, adjust the vertical airflow direction by adjusting the louvers of upward/do­wnward direction. And then, hold two ends of left and right louver to adjust the horizontal air­flow.
Don't insert your hands or stick into the air
intake or outlet vents.
Otherwise it will cause accident.
Don't apply the cold wind to the body for a
long time.
It can cause the health problems.
Splashing water on the air conditioner can
cause an electric shock and malfunction.
Louver of left/right directionLouver of upward/
Don't blow the wind to animals and plants
directly. It can cause a bad influence to them.
Don't use the air conditioner for other purposes,
such as drying clothes, preserving foods, etc.
Don't place a space heater near the air conditioner.
downward direction.
Or CO toxicosis may occur for imcomplete burning.
2
Notices for use
Working principle and special functions for cooling
Principle:
Air conditioner absorbs heat in the room and transmit to outdoor and discharged, so that indoor ambient temperature decreased, its cooling capacity will increase or decrease by
outdoor ambient temperature.
Anti-freezing function:
If the unit is running in COOL mode and in low temperature, there will be frost formed on the heat exchanger, when indoor heat exchanger temperature decreased below 0 , the indoor unit microcomputer will stop compressor running and protect the unit.
Working principle and special functions for heating
Principle:
Air conditioner absorbs heat from outdoor and transmits to indoor, in this way to increase
*
room temperature. This is the heat pump heating principle, its heating capacity will be reduced due to outdoor temperature decrease. If outdoor temperature becomes very low, please operate with other heating equipments.
*
Defrosting:
When outdoor temperature is low but high humidity, after a long while running, frost will
*
form on outdoor unit, that will effect the heating effect, at this time, the auto defrosting function will act, the heat running will stop for 8-10mins.
During the auto defrosting, the fan motors of indoor unit and outdoor unit will stop.
*
During the defrosting, the indoor indicator flashes, the outdoor unit may emit
*
This is due to the defrosting, it isn't malfunction.
After defrosting finished,the heating will recover automatically.
*
vapor.
Anti-cool wind function:
In "Heat" mode, under the following three kinds of state, if indoor heat exchanger doesn't arrive at certain temp., indoor fan will not act, in order to prevent cool wind blowing(within 2 mins):
1. Heating starts. 2.After Auto Defrost finished. 3.Heating under the low temperature.
Gentle Breeze
In the following situation, the indoor unit may blow gentle breeze, and the guide louver rotate to a certain position:
1. In “Heat” mode, the unit turned on, the compressor doesn’t arrive the starting condition
2. In “Heat” mode, the temperature arrive at the setting value and the compressor stop running about 1min.
3
.
Notices for use
Working temperature range
Indoor sideDB/WB(oC)
Maximum cooling
Maximum heating
The operating temperature range (outdoor temperature) for cooling only unit is 18~ 43; for heat pump unit is -7~ 43.
32/23
27/---
For Models:
GWC09KF-D3DNXXC,GWC12KF-D3DNXXC,GWH09KF-D3DNXXC,GWH12KF-D3DNXXC
The operating temperature range (outdoor temperature) for cooling only unit is 18~ 43℃;
for heat pump unit is -15~ 43
.
Outdoor sideDB/WB(oC)
43/26
24/18
4
Names and functions of each part
Indoor unit
Air in
SET TEMP
Cool Heat
ON/OFF
Air out
Dry Run
Receive window
Wireless
remote control
Remote control
Front panel
⑵ ⑶
Filter
Guide louver
Wall pipe
⑸ ⑹
Bind tape
Drainage pipe
Outdoor unit
Air in
Air out
Air in
Air out
Air in
Air out
5
Operation of remote controller
1
2
ON/OFF
Press it to start or stop
operation.
MODE
Press it to select operation mode
(AUTO/COOL/DRY/FAN/HEAT).
1
5
7
9
12
FAN
AIR
HUMIDITY
FILTER
TURBO
ON/OFF
FAN
10
X-FAN
13
TURBO
AUTO
HEALTH
TEMP
SLEEP
OPER
X-FAN
HOUR
ON/OFF
MODE
TIMER
LIGHT
3
: Press it to decrease temperature
-
setting.
4
+
: Press it to increase temperature
setting.
5
FA
N
Press it to set fan speed.
2
6
Press it to set up & down swing angle.
43
7
HEALTH SAVE
( page 9)
Press it to turn on or off health function.
6
8
8
11
14
Press it to set left & right swing angle.
9
X-FAN ( page 9)
10
TEMP( page 9)
11
TIMER
Press it to set timer ON/ timer OFF.
12
TURBO( page 9)
13
SLEEP( page 10)
14
LIGHT
Press it to turn on/off the light.
6
19
Operation of remote controller
16 17
18
15
MODE icon:
If MODE button is pressed,
current operation mode icon
(AUTO), ( COOL),
(DRY), (FAN) or (HEAT
16
17
18
19
only for heat pump models) will show.
LOCK icon:
is displayed by pressing "+" and “-” buttons simultaneously. Press them again to clear the display.
LIGHT icon:
is displayed by pressing the LIGHT button. Press LIGHT button again to clear the display.
SLEEP icon :
is displayed by pressing
the SLEEP button. Press this button again to clear the display.
TEMP icon:
Pressing TEMP button,
(set temperature),
ambient temperature) (outdoor ambient temperature) and blank is displayed circularly.
(indoor
FAN
HEALTH
AIR
HUMIDITY
FILTER
TURBO
191520
24
AUTO
OPER
X-FAN
23
HOUR
ON/OFF
22
21
20
Up & down swing icon:
is displayed when pressing
the
up & down swing
Press this button again to clear the
display.
21
Left & right swing icon:
is displayed when pressing the
left & right swing
button again to clear the display.
22
SET TIME display:
After pressing TIMER button,
ON or OFF will blink.This area will show the set time.
23
DIGITAL display:
This area will show the set tempe­rature. In SAVE mode,"SE" will be
displayed. During defrosting opera­ tion, “H1” will be displayed.
24
FAN SPEED display:
Press FAN button to select the desired fan speed setting(AUTO-
Low-Med-High).Your selection will be displayed in the LCD windows, except the AUTO fan speed.
button.
button.Press this
7
Loading...
+ 21 hidden pages