Gree GWC09QC-D3DNA3D/I, GWC09QC-D3DNC2D/I, GWC09QC-A3DNA2D/I, GWC09QC-D3DNA2D/I, GWC09QC-A3DNC2D/I Owner's Manual

...
Split Air Conditioner
Thank you for choosing our product.
If you have lost the Owner’s Manual, please contact the local agent or visit www.gree.com or sent email to global@gree.com.cn for electronic version.
For proper operation, please read and keep this manual carefully.
GWC09QC-A3DNA1D/I
GWH09QC-A3DNA1D/I GWH09QC-D3DNA1D/I
GWH09QC-A3DNB2D/I
GWH09QC-A3DNA5D/I
GWC12QC-A3DNA1D/I GWC12QC-D3DNA1D/I
GWC12QC-A3DNB2D/I
GWC12QC-A3DNB4D/I
GWH12QC-A3DNA1D/I GWH12QC-D3DNA1D/I
GWH12QC-A3DNA5D/I GWH12QC-D3DNB8D/I GWH12QC-D3DNA3D/I GWH12QC-A3DNB8D/I
GWH12QC-A3DNB2D/I
GWH12QC-A3DNB4D/I
GWC12QC-A3DNB8D/I
GWH18QD-D3DNB6D/I GWH18QD-D3DNB8D/I
GWC12QC-D3DNC2D/I
GWC09QC-A3DNC2D/I
GWC12QC-A3DNC2D/I
GWC09QC-A3DNB6D/I GWH09QC-A3DNB6D/I
GWC12QC-A3DNB6D/I GWC12QC-D3DNB6D/I
GWC09QC-D3DNC2D/I
GWC12QC-A3DNA2D/I
GWC09QC-A3DNA2D/I GWC09QC-D3DNA2D/I
GWC09QC-A3DNA3D/I GWC09QC-D3DNA3D/I
GWH09QC-A3DNA2D/I GWH09QC-D3DNA2D/I
GWH12QC-A3DNA2D/I
GWC12QC-A3DNA3D/I
GWH12QC-A3DNA3D/I
GWH09QC-A3DNA3D/I
GWC24QE-D3DNB4D/I
GWH24QE-D3DNA1D/I GWH24QE-D3DNA5D/I GWH24QE-D3DNB2D/I GWH24QE-D3DNB4D/I GWH24QE-D3DNB8D/I
GWH24QE-D3DNA3D/I
GWC24QE-D3DNA2D/I
GWH24QE-D3DNA2D/I
GWC24QE-D3DNB8D/I
GWC24QE-D3DNA3D/I
GWC24QE-D3DNB2D/I
GWC24QE-D3DNA5D/I
GWC24QE-D3DNA1D/I
GWH24QE-D3DNB6D/I
Content
Operation Notices
Precautions............................................................................................................1
Parts name ............................................................................................................6
Screen Operation Guide
Buttons on remote controller .................................................................................8
Introduction for icons on display screen ................................................................8
Introduction for buttons on remote controller .........................................................9
Function introduction for combination buttons .....................................................13
Operation guide ...................................................................................................15
Replacement of batteries in remote controller .....................................................15
Emergency operation .......................................................................................... 16
Maintenance
Clean and maintenance.......................................................................................16
Malfunction
Malfunction analysis ............................................................................................19
Installation Notice
Installation dimension diagram ............................................................................23
Tools for installation .............................................................................................24
Selection of installation location ..........................................................................24
Requirements for electric connection ..................................................................25
Installation
Installation of indoor unit......................................................................................26
Check after installation ........................................................................................31
Test and operation
Test operation ......................................................................................................31
Attachment
Pipe expanding method .......................................................................................34
Configuration of connection pipe.........................................................................32
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Explanation of Symbols
Indicates a hazardous situation that, if not avoided, will result in death or serious injury.
Indicates a hazardous situation that, if not avoided, could result in death or serious injury.
Indicates a hazardous situation that, if not avoided, may result in minor or moderate injury.
Indicates important but not hazard-related information, used to indicate risk of property damage.
Indicates a hazard that would be assigned a signal word WARNING or CAUTION.
1
Precautions
WARNING
Do not connect air conditioner to multi-purpose socket.
This appliance can be used by children aged from 8
Operation and Maintenance
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Do not spray water on indoor unit. It may cause electric shock or malfunction.
Otherwise, it may cause fire hazard.
Children shall not play with the appliance. Cleaning and user maintenance shall not be made by
children without supervision.
years and above and persons with reduced physical, sensory ormental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Do not wash the air conditioner with water to avoid electric shock.
After removing the filter, do not touch fins to avoid injury. Do not use fire or hair dryer to dry the filter to avoid
deformation or fire hazard.
Do disconnect power supply when cleaning air conditioner. Otherwise, it may cause electric shock.
.
Do not block air outlet or air inlet. It may cause malfunction.
remote controller may be broken.
Power cord is overheating or damaged.
There’s abnormal sound during operation.
Circuit break trips off frequently.
Air conditioner gives off burning smell.
Indoor unit is leaking.
contact the dealer or qualified professionals for service.
When turning on or turning off the unit by emergency operation switch, please press this switch with an insulating object other than metal.
outlet. It may cause personal injury or damage.
2
Precautions
conditioner and disconnect power immediately, and then
If the air conditioner operates under abnormal conditions, it may cause malfunction, electric shock or fire hazard.
Do not spill water on the remote controller, otherwise the
electric shock or damage. Please contact dealer when you need to repair air conditioner.
Do not repair air conditioner by yourself. It may cause
objects. It may cause damage or personal injury.
Do not step on top panel of outdoor unit, or put heavy
When below phenomenon occurs, please turn off air
Do not extend fingers or objects into air inlet or air
Maintenance must be performed by qualified professionals. Otherwise, it may cause personal injury
or damage.
WARNING
Do install the circuit break. If not, it may cause malfunction.
of at least 3mm in all poles should be connected in fixed wiring.
magnet buckle
and heating buckle function, it can protect
the circuit-short and
overload.
power supply circuit and circuit break.
3
Precautions
note
the following table. Air switch should be included
Make sure the power supply matches with the requirement of air conditioner. Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
An all-pole disconnection switch having a contact separation
Must follow the electric safety regulations when installing the unit.
grounding wire of power socket.
Properly connect the live wire, neutral wire and
any work related to electricity and safety.
Be sure to cut off the power supply before proceeding
Including an circuit break with suitable capacity, please
Air Conditioner should be properly grounded. Incorrect
Don't use unqualified power cord.
grounding may cause electric shock.
According to the local safety regulations, use qualified
Installation must be performed by qualified professionals. Otherwise, it may cause personal injury or damage.
Attachment
WARNING
Installation must be performed in accordance with the
persons in order to avoid a hazard.
must be properly grounding with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock.
The appliance must be positioned so that the plug is accessible.
If the length of power connection wire is insufficient, please contact the supplier for a new one. Avoid extending the wire by yourself.
All wires of indoor unit and outdoor unit should be connected by a professional.
national wiring regulations.
requirement of NEC and CEC by authorized personnel only.
4
Precautions
wire, which can't be used for other purposes.
The grounding resistance should comply with national electric safety regulations.
The air conditioner is the first class electric appliance. It
keep the interconnection cable away from the copper tube.
The temperature of refrigerant circuit will be high, please
the manufacturer, its service agent or similarly qualified
If the supply cord is damaged, it must be replaced by
The yellow-green wire in air conditioner is grounding
The appliance shall be installed in accordance with
Do not put through the power before finishing installation.
WARNING
The indoor unit should be installed close to the wall.
reachable after finishing installation.
far away from animals or plants. If it is unavoidable, please add the fence for safety purpose.
Precautions
place, only the qualified person can perform the work. Otherwise, it may cause personal injury or damage.
If you need to relocate the air conditioner to another
must be installed in the line.
For the air conditioner without plug, an circuit break
Select a location which is out of reach for children and
For the air conditioner with plug, the plug should be
Working temperature range
Indoor side DB/WB(°C/°F) Outdoor side DB/WB(°C/°F) Maximum cooling 26.7/19.4(80/66.9) 46.1/23.9(115/75) Maximum heating 26.7/-(80/-) 23.9/18.3(75/64.9)
● The operating temperature range (outdoor temperature) for cooling only unit is
-18(-0.4°F)~46.1(115°F); for heat pump unit is-20(-4°F)~46.1(115°F).
NOTICE:
5
WARNING
6
(Display content or position may be different from above graphics, please refer to actual products)
Parts Name
Indoor Unit
air inlet panel
aux.button
horizontal louver
air outlet
remote control
Actual product may be different from above graphics, please refer to actual products.
NOTICE:
Parts Name
Display content or position may be different from above graphics, please refer to actual products.
Display
W R G
temp. indicator
display
receiver window
W R O
temp. indicator
display
receiver window
heating indicator
temp. indicator
cooling indicator
power indicator
receiver window
drying indicator
display
For some model:
For some model:
For some model:
For some model:
heating indicator
temp. indicator
cooling indicator
power indicator
receiver window
drying indicator
display
G
W
R
Power LED color indicator: Green-status-ON. Red -status-OFF.
Mode LED color indicator: White-W-Cool Mode-
Red-R-Heat Mode-
Green-G-Dry Mode-
O
W
R
Power LED color indicator: Green-status-ON. Red -status-OFF.
Mode LED color indicator: White-W-Cool Mode-
Red-R-Heat Mode­Orange-O-Dry Mode-
(only for heating model)
(only for heating model)
7
Loading...
+ 28 hidden pages