Gree GWC09KF-K3DNA7A user guide manual

Change for Life
Split Air Conditioner
Owner's Manual Residential Air Conditioners
Thank you for choosing Residential
manual carefully before operation and retain it for future reference.
Air Conditioners, please read this owner’s
GWH09KF-K3DNA6B
GWC09KF-K3DNA5A GWH09KF-K3DNA5A GWC09KF-K3DNA5D GWH09KF-K3DNA9A GWC09KF-K3DNA6A GWH09KF-K3DNA6A GWH09KF-K3DNA5B
GWH09KF-K3DNB1A
GWH09KF-K3DNA7A
GWC09KF-K3DNA7A GWC09KF-D3DNA7A GWC09KF-K3DNA9A GWH09KF-K3DNB3A GWH09KF-K3DNB2A GWC09KF-K3DNB2A GWH12KF-K3DNB2A
GWH12KF-K3DNA7A GWH12KF-K3DNA5A GWH12KF-K3DNA9A GWC12KF-K3DNA5A GWC12KF-K3DNA5D GWC12KF-K3DNA6A GWH12KF-K3DNA5B GWH12KF-K3DNA6A
GWH12KF-K3DNB1A GWH12KF-K3DNA6B GWC12KF-D3DNA7A GWC12KF-K3DNA7A GWC12KF-K3DNA9A GWH12KF-K3DNB3A GWC12KF-K3DNB2A GWH12KF-K3DNB1B
CONTENTS
Operation and maintenance
Notices for operation ............................................................. 1
Notices for use .................................................................... 3
Names and functions of each part ........................................... 5
Operation of wireless remote control ........................................ 6
Emergency operation .......................................................... 11
Clean and care .................................................................. 12
Troubleshooting ................................................................. 14
Installation service
Notices for installation ......................................................... 17
Installation dimension diagram
Install indoor unit
Install outdoor unit
Check after installation and test operation ............................... 23
Installation and Maintenance of Healthy Filter .......................... 24
Install snow guard (Optional) ................................................ 25
This symbol stands for the items should be forbidden.
The products in this manual may be different with the real one, according to different models, some models have displayer and some models without displayer, the position and shape of the displayer please refer to the real one.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance
by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
................................................................ 20
.............................................................. 22
.............................................. 19
This symbol stands for the items should be followed
Operation and maintenance-notices for operation
Earth: The ground be connected!
If not, please ask the qualified person­nel to install. Furthermore, don't conn­ect each wire to the gas pipe, water pipe, drainage pipe or any other impr­oper places.
Be sure to pull out the power
plug when not using the air co­nditioner for a long time.
Otherwise, the accumulated dust may cause fire or electric shock.
perature.
Keep room cool- er than outside about 5 degree.
It can preclude the electricity wasted.
Select the most appropriate tem-
Don't leave windows and
doors open for a long time while operating the air conditioner.
It can decrease the air conditioning capacity.
Please note whether the installed
stand is firm enough or not.
If it is damaged, it may lead to the fall of the unit and cause the injury.
Don't block the air intake or outlet
vents of both the outdoor and indoor units.
It can decrease the air conditioning capacity or cause a malfunction.
Don't step on the top of the
outdoor unit or place something on it.
As falling off the outdoor unit can be dangerous.
Keep combustible spray away from the units more than 1m.
It can cause afire or explosion.
Don't attempt to repair
the air conditioner by yourself.
The wrong repair will lead to an electric shock or fire, so you should contact the service center to repair.
Notices for operation
If the supply cord is damaged, it must be replaced
by the manufacturer or its service agent or a
similarly qualified person in order to avoid a hazard.
The airflow direction can be adjusted appro-
priately. At operating, adjust the vertical airflow direction by adjusting the louvers of upward/do­wnward direction. And then, hold two ends of left and right louver to adjust the horizontal air­flow.
Don't insert your hands or stick into the air
intake or outlet vents.
Otherwise it will cause accident.
Don't apply the cold wind to the body for a
long time.
It can cause the health problems.
Splashing water on the air conditioner can
cause an electric shock and malfunction.
Louver of left/right directionLouver of upward/
Don't blow the wind to animals and plants
directly. It can cause a bad influence to them.
Don't use the air conditioner for other purposes,
such as drying clothes, preserving foods, etc.
Don't place a space heater near the air conditioner.
downward direction.
Or CO toxicosis may occur for imcomplete burning.
Notices for use
Working principle and special functions for cooling
Principle:
Air conditioner absorbs heat in the room and transmit to outdoor and discharged, so that
indoor
ambient temperature decreased, its cooling capacity will increase or decrease by
outdoor ambient temperature.
Anti-freezing function:
If the unit is running in COOL mode and in low temperature, there will be frost formed on the heat exchanger, when indoor heat exchanger temperature decreased below 0 , the indoor unit microcomputer will stop compressor running and protect the unit.
Working principle and special functions for heating
Principle:
Air conditioner absorbs heat from outdoor and transmits to indoor, in this way to increase
*
room temperature. This is the heat pump heating principle, its heating capacity will be reduced due to outdoor temperature decrease. If outdoor temperature becomes very low, please operate with other heating equipments.
*
Defrosting:
When outdoor temperature is low but high humidity, after a long while running, frost will
*
form on outdoor unit, that will effect the heating effect, at this time, the auto defrosting function will act, the heat running will stop for 8-10mins.
During the auto defrosting, the fan motors of indoor unit and outdoor unit will stop.
*
During the defrosting, the indoor indicator flashes, the outdoor unit may emit vapor.
*
This is due to the defrosting, it isn't malfunction.
After defrosting finished,the heating will recover automatically.
*
Anti-cool wind function:
In "Heat" mode, under the following three kinds of state, if indoor heat exchanger doesn't arrive at certain temp., indoor fan will not act, in order to prevent cool wind blowing(within 2 mins):
1. Heating starts. 2. After Auto Defrost finished. 3. Heating under the low temperature.
Gentle Breeze
In the following situation, the indoor unit may blow gentle breeze, and the guide louver rotate to a certain position:
1. In “Heat” mode, the unit turned on, the compressor doesn’t arrive the starting condition
2. In “Heat” mode, the temperature arrive at the setting value and the compressor stop
running about 1min.
3
.
Notices for use
The operating temperature range (outdoor temperature) for cooling unit is 21
~
43℃;
for cooling and heating unit is -5
~
43℃.
Working temperature range
Maximum cooling
Minimum cooling
Maximum heating Minimum heating
Indoor sideDB/WB(oC)
Outdoor sideDB/WB(oC) 32/23 21/15
27/--­20/---
24/18
/---
48 10/--
-15/--
4
Names and functions of each part
Indoor unit
SET TEMP
Cool Heat
ON/OFF
Outdoor unit
Air in
Air in
Air out
Wireless
Dry
remote control
Run Receive window
Air in
Power cable
Remote control
Front panel
Filter
Guide louver
Wall pipe
⑹ ⑺
Bind tape Drainage pipe
Air out
Air out
5
Operation of wireless remote control
Names and functions of remote control buttons
Note: Be sure that there are no obstructions between receiver and remote control; Don't drop
or throw the remote control; Don't let any liquid in the remote control and put the remote control
directly under the sunlight or any place where is very hot
Signal transmitter
AUTO
FAN
OPER
HEALTH
X-FAN
AIR
HUMIDITY
FILTER
TURBO
HOUR
ON/OFF
MODE
Remote control
ON/OFF
Press this button, the unit will be started or stopped,
ON/OFF
FAN
X-FAN
TEMP
SLEEP
TURBO
ON/OFF button
TIMER
LIGHT
which can clear the timer or sleeping function of last time.
MODE
Press this button, the running mode
Mode button
will change as
below.
AUTO COOL
DRY
FAN
(Only for cooling and heating unit.)
HEAT
(As for cooling only unit, it won’t have any action when it receives the signal of heating operation. )
(/)
Note:Under the Dry mode, the fan speed isn't
.
TEMP(+/-) button
When press +button , the setting temp. will b
increased by 1 ,When press -button,the setting temp. will be decreased by 1
The temp. will be changed quickly
by pressing
the button continuously and setting temp. range is
1630℃。
FAN
FAN speed button
Press this button once, fan speed will change as below:
Auto
Low speed Middle speed
High speed
adjustable, low fan speed is imperative, but when operating this button, the wireless remote control will send this signal.
Swing up and down button
Simpleness swing mode is defaulted for wireless remote control, in this mode, press this button,
could turn on or turn off the Up and down swing function.
When unit is turned off, synchronously press "+" and Up and down swing buttons, it could
be switched between the simpleness swing mode and stationary swing mode, at this time,
blinks 2 seconds.
In Stationary swing mode, press this button,the angle for Up and down swing as show in below:
When up and down swing louver is working, when turn off the unit, the siwng louver will immediately stop at current position.
shows up and down swing louver swings back
and forth as show in the above figure.
e
6
Loading...
+ 20 hidden pages