Gree GWC09AB-D3DNA2D, GWH09AB-D3DNA2D, GWC12AB-D3DNA2D, GWH12AB-D3DNA2D, GWC18AC-D3DNA2D Installation Manual

...
Change for Life
Split Air Conditioner
Installation Manual
Residential Air Conditioners
Thank you for choosing Residential Air Conditioners,please read this owner’s
manual carefully before operation and retain it for future reference.
GWC12AB-D3DNA2D
GWH12AB-D3DNA2D
GWC18AC-D3DNA2D
GWH18AC-D3DNA2D
GWC24AC-D3DNA2D
GWH24AC-D3DNA2D
.............................................3
...............................................................4
........................................................1
..............................9
Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment
is necessary.
CONTENTS
Notices for installation
Installation dimension diagram
Install indoor unit
Test operation and check after installation
.......................10
Installation and Maintenance of Healthy Filter
Never attempt.
Be sure to follow this instruction
The physical product may differ from the drawing in this manual for different display. If there are some differences between them, please refer to the physical product as
the standard
.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure they are away from the appliance.
.............................................................7
Install outdoor unit
1
Notices for installation
4
.
Warning: Before obtaining access to terminals, all supply circuits must be disconnected.
5.
For appliances with type Y attachment, the instructions shall contain the substance of
the following. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
6.The appliance must be positioned so that the plug is accessible.
7.The temperature of refrigerant line will be high; please keep the interconnection cable away from the copper tube.
8. The instructions shall state the substance of the following: This appliance is not intended for use by persons(including children)with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Caution
Installation Site Instructions
The unit should be installed only by authorized service center according to local or
government regulations and in compliance with this manual.
Before installing, please contact with local authorized maintenance center. If the unit is
not installed by the authorized service center, the malfunction may not be solved due to incovenient contact between the user and the service personnel.
When removing the unit to the other place, please firstly contact with the local authorized
service center.
Proper installation site is vital for correct and efficient operation of the unit. Avoid the following sites where:
strong heat sources, vapours, flammable gas or volatile liquids are emitted.
high-frequency electro-magnetic waves are generated by radio equipment, welders and medical equipment. salt-laden air prevails (such as close to coastal areas).
the air is contaminated with industrial vapours and oils.
the air contains sulphures gas such as in hot spring zones.
corrosion or poor air quality exists.
1
.
2.
3.
Installation Site of Indoor Unit
Select a site where the condensate can be easily drained out, and where it is easily connected to outdoor unit.
Select a place where the wall is strong enough to withstand the full weight and vibration of the unit.
Select a place where it is out of reach of children.
The air inlet and outlet should be away from the obstructions. Ensure the air can be
blown through the whole room.
Be sure to leave enough space to allow access for routine maintenance. The installation site should be 98 3/7 inch or more above the floor
5.
4.
1
.
2.
3.
2
Notices for installation
Note:
Safety Precautions for Electric Appliances
Installation Site of Outdoor Unit
1
.
Select a site where noise and outflow air emitted by the unit will not annoy neighbors. Select a site where there is sufficient ventilation.
Select a site where there is no obstruction blocking the inlet and outlet. The site should be able to withstand the full weight and vibration. Select a dry place, but do not expose the unit to direct sunlight or strong wind. Make sure that the outdoor unit is installed in accordance with the installation instructions,
and is convenient for maintenance and repair.
The height difference between indoor and outdoor units is within16.4ft, and the length of
the connecting tubing does not exceed 32.8ft.
Select a place where it is out of reach of children.
Select a place where the unit does not have negative impact on pedestrians or on the city.
5. The minimum distance between the unit and combustive surface is
4.9ft.
1. A dedicated power supply circuit should be used in accordance with local electrical
safety regulations.
2. Don't drag the power cord with excessive force.
3.
The appliance shall be installed in accordance with national wiring regulations.
An all-pole disconnection switch with a contact separation of at least
9.8ft in all poles
should be connected in fixed wiring.
The unit should be reliably earthed and connected to an exclusive earth device by the
professionals.
4. The air switch must have the functions of magnetic tripping and heat tripping to prevent short circuit and overload.
Make sure the live wire, neutral wire and earth wire in the family power socket are properly connected. There should be reliable circuit in the diagram.
Inadequate or incorrect electrical connections may cause electric shock or fire.
6.
7.
2.
3.
4.
5.
6.
7.
8.
9.
Make sure that the indoor unit is installed in accordance with installation dimension
Select a place about 3.3ft or more away from TV set or any other electric appliance.
Select a place where the filter can be easily taken out.
instructions.
6.
7.
8.
9. Do not use the unit in the laundry or by swimming pool etc.
Earthing Requirements
① ②
1. Air conditioner is type I electric appliance. Please ensure that the unit is reliably earthed.
2. The yellow-green wire in air conditioner is the earthing wire which can not be used for other purposes. Improper earthing may cause electric shock.
3. The earth resistance should accord to the national criterion.
4. The power must have reliable earthing terminal. Please do not connect the earthing wire with the following:
W epip saGepip reta
Contamination pipe
Other place that professional personnel consider is unreliable
5. The model and rated values of fuses should accord with the silk print on fuse cover or
related
PCB.