Gree GMV-ND25PHS/B-T, GMV-ND28PHS/B-T, GMV-ND32PHS/B-T, GMV-ND36PHS/B-T, GMV-ND40PHS/B-T Owner's Manual

...
Owner's Manual
Original Instructions
Commercial Air Conditioners
Super High Static Pressure Duct Type Indoor Unit
Models:
GMV-ND22PHS/B-T GMV-ND25PHS/B-T GMV-ND28PHS/B-T GMV-ND32PHS/B-T GMV-ND36PHS/B-T GMV-ND40PHS/B-T GMV-ND45PHS/B-T GMV-ND50PHS/B-T GMV-ND56PHS/B-T GMV-ND63PHS/B-T GMV-ND71PHS/B-T GMV-ND80PHS/B-T GMV-ND90PHS/B-T GMV-ND100PHS/B-T GMV-ND112PHS/B-T GMV-ND125PHS/B-T GMV-ND140PHS/B-T GMV-ND160PHS/B-T
To Users
Thank you for selecting Gree’s product. Please read this instruction manual carefully before
installing and using the product, so as to master and correctly use the product. In order to guide you to correctly install and use our product and achieve expected operating effect, we hereby instruct as below:
(1) This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsibility for their safety. Children should be supervised to ensure that they do not play with the appliance.
(2) In order to ensure reliability of product, the product may consume some power under
stand-by status for maintaining normal communication of system and preheating refrigerant and lubricant. If the product is not to be used for long, cut off the power supply; please energize and preheat the unit in advance before reusing it.
(3) Please properly select the model according to actual using environment, otherwise it may
impact the using convenience.
(4) This product has gone through strict inspection and operational test before leaving the
factory. In order to avoid damage due to improper disassembly and inspection, which may impact the normal operation of unit, please do not disassemble the unit by yourself. You can contact with the special maintenance center of our company if necessary.
(5) For personal injury or property loss and damage caused by improper operation such as
improper installation and debugging, unnecessary maintenance, violation of related national laws and rules and industrial standard, and violation of this instruction manual, etc., we will bear no liability.
(6) When the product is faulted and cannot be operated, please contact with our maintenance
center as soon as possible by providing the following information.
1) Contents of nameplate of product (model, cooling/heating capacity, product No., ex­factory date).
2) Malfunction status (specify the situations before and after the error occurs).
(7) All the illustrations and information in the instruction manual are only for reference. In
order to make the product better, we will continuously conduct improvement and innovation. We have the right to make necessary revision to the product from time to time due to the reason of sales or production, and reserve the right to revise the contents without further notice.
(8) The final right to interpret for this instruction manual belongs to Gree Electric Appliances
Inc. of Zhuhai.
Contents
1 Safety Notices (Please be sure to abide ) ........................................................................... 1
2 Product Introduction ................................ ................................................................ ........... 3
2.1 Names of Key Components ................................................................................................ 3
2.2 Rated Working Condition .................................................................................................... 3
3 Preparations for Installation ................................................................................................ 3
3.1 Standard Fittings ................................................................................................................. 3
3.2 Location for Installation ....................................................................................................... 4
3.3 Requirements for Communication Line .............................................................................. 5
3.4 Wiring Requirements .......................................................................................................... 6
4 Installation Instructions ....................................................................................................... 7
4.1 Installation of Indoor Unit .................................................................................................... 7
4.2 Refrigerant Pipe Connection ............................................................................................... 9
4.3 Drainage Pipe Installation and Drainage System Testing .................................................. 9
4.4 Installation of Air Duct ....................................................................................................... 13
4.5 Installation of Wired Controller .......................................................................................... 15
5 Wiring Work .......................................................................................................................16
5.1Connection of Wire and Patch Board Terminal .................................................................. 16
5.2 Power Cord Connection .................................................................................................... 17
5.3 Connection of Communication Wire between Indoor Unit and Outdoor Unit (or indoor unit)
................................................................................................................................................. 17
5.4 Connect Communication Wire of Wired Controller ........................................................... 18
5.5 Illuminate for Connection of Wired Controller and Indoor Units Network ......................... 18
6 Setting of External Static Pressure ....................................................................................20
7 Routine Maintenance.........................................................................................................20
7.1 Cleaning of Filter ............................................................................................................... 20
7.2 Maintenance before the Seasonal Use ............................................................................ 20
7.3 Maintenance after the Seasonal Use................................................................................ 20
8 Table of Error Codes for Indoor Unit ..................................................................................21
9 Troubleshooting .................................................................................................................21
Multi Variable Air Conditioners Ducted Type Indoor Unit
1
1 Safety Notices (Please be sure to abide )
Warning: If not abide strictly, it may cause severe damage to the unit or the people.
Note: If not abide strictly, it may cause slight or medium damage to the unit or the people.
This sign indicates that the operation must be prohibited. Improper operation may cause severe damage or death to people.
This sign indicates that the items must be observed. Improper operation may cause damage to people or property.
Please install the unit according to instructions in this manual. Read this manual carefully before starting up or checking the machine.
Installation should be performed by dealer or qualified technicians. Do not install the product by yourself. Improper installation may result in water leakage, electric shock or fire hazard.
Make sure the local power supply is in accordance with units before installation, and check the power supply carefully.
This air conditioner must be properly grounded through the receptacle to avoid electric shock. The grounding wire shouldn’t be connected with gas pipe, water pipe, lightning arrester or telephone line.
Please use specialized accessories or parts to carry out installation, or water leakage, electric shock, fire hazard may resulted.
R410A refrigerant can produce poisonous gas once it meets fire, so please ventilate the room immediately if refrigerant leaks out during installation.
Diameter of power cord must be large enough. Damaged power cord and connecting wire must be replaced by specialized electric cable.
After the power cord is Connected, please install the cover of electric box to avoid danger.
Nitrogen must be charged according to technical requirements.
Short circuit is forbidden. Do not cancel the pressure switch in case the unit may be damaged.
For units with wired controller, do not connect power supply until the wired controller is well installed. Otherwise, the wired controller cannot be used.
When the installation is finished, please check and make sure the drain pipe, pipeline and electric wire are all well connected in order to avoid water leakage, refrigerant leakage, electric shock or fire hazard.
Do not extend fingers or objects into air outlet or air return grille.
If you use gas heater or petroleum heater in the same room, please open the door or window to maintain good air circulation in case the room may lack of oxygen.
Multi Variable Air Conditioners Ducted Type Indoor Unit
2
Never start or stop the air conditioner by inserting or removing the power cord.
Do not turn off the air conditioner until it runs for at least 5 minutes. Otherwise, oil-return of the compressor will be affected.
Children are not allowed to operate the air conditioner.
Do not operate the air conditioner with wet hands.
Please turn the unit off and unplug your air conditioner before cleaning. Otherwise, it may cause electric shock or personal injury.
Do not spray water on the air conditioner or it will cause malfunction or electric shock.
Do not expose the air conditioner directly to water or place it in a damp or corrosive environment.
Connect power supply 8 hours before operation. Do not disconnect power if you want to stop the unit in a short period of time, e.g. in one night. (This is for protecting the compressor.)
Volatile liquid like thinner or gasoline will damage the appearance of air conditioner. (Please use soft dry cloth and wet cloth with mild detergent to clean the outer case of air conditioner.)
During Cooling mode, indoor temperature should not be set too low. Keep the difference between indoor temp and outdoor temp within 5°C.
If abnormal condition occurs (e.g. unpleasant smell), please turn off the unit at once and disconnect power supply. Then contact GREE service center. If the air conditioner continues to operate despite of abnormal condition, the unit may be damaged and it may cause electric shock or fire hazard.)
Do not repair the air conditioner by yourself. Improper repair will cause electric shock or fire hazard. Please contact GREE service center and have it repaired by professional technicians.
Any personal injury or property loss caused by improper installation, improper debug, unnecessary repair or not following the instructions of this manual should not be the responsibility of Gree Electric Appliances, Inc. of Zhuhai.
Correct Disposal of this product
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.
R410A (R32/125:50/50):2087.5
Multi Variable Air Conditioners Ducted Type Indoor Unit
3
2 Product Introduction
2.1 Names of Key Components
Fig 2.1
No.
① ② ③ ④ ⑤ ⑥ ⑦
Name
Drain Pipe
Control
box
Pothook
Gas pipe
Liquid pipe
Air-return
Opening
Air Outlet
2.2 Rated Working Condition
Indoor Side Condition
Outdoor Side Condition
Dry Bulb Temp()
Wet Bulb Temp()
Dry Bulb Temp()
Wet Bulb Temp()
Rated Cooling
27(80.6)
19(66.2)
35(95)
24(75.2)
Rated Heating
20(68.0)
15(59.0)
7(44.6)
6(42.8)
3 Preparations for Installation
Note:
Product graphics are only for reference. Please refer to actual products. Unspecified
measure unit is mm.
3.1 Standard Fittings
Please use the supplied standard fittings listed below as instructed.
No.
Name
Appearance
Q'ty
Usage
1
Wired Controller
1
To control the indoor unit
2
Drain Hose Assembly
1
To connect with the hard PVC drain pipe
3
Special Nut
1
To be used for connecting the refrigerant
pipe
Multi Variable Air Conditioners Ducted Type Indoor Unit
4
No.
Name
Appearance
Q'ty
Usage
4
M10X8 Nut with Washer
4
To be used together with the hanger bolt
for installing the unit.
5
M10 Nut (M10X8.4 Nut)
4
To be used together with the hanger bolt
for installing the unit.
6
M10 Washer (Spring Washer
M10X2.6)
4
To be used together with the hanger bolt
for installing the unit.
7
Insulation
1
To insulate the gas pipe
8
Insulation
1
To insulate the liquid pipe
9
Sponge
2
To insulate the drain pipe
10
Fastener
8
To fasten the sponge
Note: User can purchase remote controller and receiver otherwise by himself.
3.2 Location for Installation
(1) The appliance shall not be installed in the laundry. (2) The top holder must be strong enough to support unit’s weight. (3) Drain pipe can drain water out easily. (4) There is no obstacle at inlet or outlet. Please ensure good air circulation. (5) In order to make sure the space for maintenance, please install the indoor unit according
to the dimension described below. (6) Keep the unit away from heating source, inflammable gas or smoke. (7) This is a concealed ceiling type unit. (8) Indoor unit, outdoor unit, power cord and electric wire should stay at least 1m from the TV
set and radio. Otherwise, these electrical appliances may have image interference and noise. (Even if the distance is 1m, when there is strong electric wave, noise may still occur.)
Multi Variable Air Conditioners Ducted Type Indoor Unit
5
Fig 3.2
Notes:
Installation of the unit must be in accordance with National Electric Codes and local
regulations.
Improper installation will affect unit’s performance, so do not install the unit by yourself.
Please contact local dealer to arrange professional technicians for the installation.
Do not connect power until all installation work is finished.
3.3 Requirements for Communication Line
Caution:
If air conditioner used under strong electronic-magnetic interference circumstance, STP
(shielded twisted pair) communication cable must be adopted.
3.3.1 Select Communication Line for Indoor Unit and Wired Controller
Fig 3.3.1