Gree GK-H03NH3AS, GK-H10NH3AF, GK-H5.5NH3AS, GK-H5.5NH3AF, GK-H15NH3AF Owner's Manual

Owner's Manual
Original Instructions
Air Conditioners
Rooftop Packaged
Models: GK-H03NH3AS GK-H5.5NH3AS GK-H5.5NH3AF GK-H10NH3AF GK-H15NH3AF
To Users
Thank you for selecting Gree’s product. Please read this instruction manual
carefully before installing and using the product, so as to master and correctly use the product. In order to guide you to correctly install and use our product and achieve expected operating effect, we hereby instruct as below:
(1) This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsibility for their safety. Children should be supervised to ensure that they do not play with the appliance.
(2) In order to ensure reliability of product, the product may consume some
power under stand-by status for maintaining normal communication of system and preheating refrigerant and lubricant. If the product is not to be used for long, cut off the power supply; please energize and preheat the unit in advance before reusing it.
(3) Please properly select the model according to actual using environment,
otherwise it may impact the using convenience.
(4) This product has gone through strict inspection and operational test
before leaving the factory. In order to avoid damage due to improper disassembly and inspection, which may impact the normal operation of unit, please do not disassemble the unit by yourself. You can contact with the special maintenance center of our company if necessary.
(5) When the product is faulted and cannot be operated, please contact with
our maintenance center as soon as possible by providing the following information.
1) Contents of nameplate of product (model, cooling/heating capacity, product No., ex-factory date).
2) Malfunction status (specify the situations before and after the error occurs).
(6) All the illustrations and information in the instruction manual are only for
reference. In order to make the product better, we will continuously
conduct improvement and innovation. We have the right to make necessary revision to the product from time to time due to the reason of sales or production, and reserve the right to revise the contents without further notice.
(7) The final right to interpret for this instruction manual belongs to Gree
Electric Appliances Inc. of Zhuhai.
Exception Clauses
Manufacturer will bear no responsibilities when personal injury or property loss
is caused by the following reasons:
(1) Damage the product due to improper use or misuse of the product; (2) Alter, change, maintain or use the product with other equipment without
abiding by the instruction manual of manufacturer; (3) After verification, the defect of product is directly caused by corrosive gas; (4) After verification, defects are due to improper operation during
transportation of product; (5) Operate, repair, maintain the unit without abiding by instruction manual or
related regulations; (6) After verification, the problem or dispute is caused by the quality
specification or performance of parts and components that produced by
other manufacturers; (7) The damage is caused by natural calamities, bad using environment or
force majeure.
Contents
1 Safety Notices (Please be sure to abide) ................................. 1
2 Product Introduction ................................................................. 4
2.1 Nominal Operating Condition ........................................................ 4
2.2 Operating Range ........................................................................... 4
3 Pre-installation Instruction........................................................ 5
3.1 Checking Product Received .......................................................... 5
3.2 Standard Accessory Parts ............................................................. 5
3.3 Before Beginning Installation ........................................................ 5
3.4 Codes & Regulations .................................................................... 5
3.5 Replacement Parts ........................................................................ 5
4 Installation Instructions ............................................................ 6
4.1 Physical Dimension ....................................................................... 6
4.2 General Information ................................ ................................ ...... 8
4.3 Location ........................................................................................ 8
4.4 Crane Way .................................................................................... 9
4.5 Installation Positions and Clearances ........................................... 9
4.6 Installation of Condensate Pipe................................................... 11
5 Electrical Installation .............................................................. 12
5.1 Electrical Date and Wire Sizing ................................................... 14
5.2 Connect Wiring to the Terminals ................................................. 14
5.3 Electrical Connections-Supply Voltage ........................................ 16
5.4 Wiring Diagram ........................................................................... 17
6 Maintenance .......................................................................... 17
7 Trial Run ................................................................................ 18
8 Troubleshooting ..................................................................... 19
9 Unit Function .......................................................................... 20
9.1 Setting of Double Indoor Room Sensors ..................................... 20
9.2 Checking of Outdoor Ambient Temperature ................................ 20
10 Error Code Meaning ............................................................ 20
Rooftop Packaged
1
1 Safety Notices (Please be sure to abide)
SPECIAL WARNING:
(1) Be sure to comply with national gas regulations. (2) Do not pierce or burn. (3) Do not use means to accelerate the defrosting process or to clean, other
than those recommended by the manufacturer.
(4) Be aware that refrigerants may not contain an odor.
PROHIBITED: This sign indicates that the operation must be prohibited. Improper operation may cause severe damage or death to people.
WARNING: If not abide strictly, it may cause severe damage to the unit or the people.
NOTICE: If not abide strictly, it may cause slight or medium damage to the unit or the people.
OBSERVED: This sign indicates that the items must be observed. Improper operation may cause damage to people or property.
Please read this operating manual carefully before operating the unit.
Before using the air conditioner, please read the instruction manual.
Before installing the air conditioner, please read the instruction manual.
Before repairing the air conditioner, please read the instruction manual. The figures in this manual may be different with the material objects, please refer to the material objects for reference.
PROHIBITED
(1) The air conditioner should be grounded to avoid electric shock. Do not connect
the ground wire to gas pipe, water pipe, lightning arrester or telephone wire.
(2) According to federal/state/local laws and regulations, all packages and
transportation materials, including nails, metal or wooden parts, and plastic packing material, must be treated in a safe way.
Rooftop Packaged
2
WARNING
(1) This product can’t be installed at corrosive, inflammable or explosive
environment or the place with special requirements, such as kitchen. Otherwise, it will affect the normal operation or shorten the service life of the unit, or even cause fire hazard or serious injury. As for above special places, please adopt special air conditioner with anti-corrosive or anti-explosion function.
(2) Do not use or store flammable, explosive, poisonous or other dangerous
substances beside the air conditioner.
(3) Any person who is involved with working on or breaking into a refrigerant circuit
should hold a current valid certificate from an industry-accredited assessment authority, which authorises their competence to handle refrigerants safely in accordance with an industry recognised assessment specification.
(4) Servicing shall only be performed as recommended by the equipment
manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
(5) The appliance shall be installed in accordance with national wiring regulations.
(6) An all-pole disconnection switch having a contact separation of at least 3mm in
all poles should be connected in fixed wiring.
(7) Air conditioner should be stored with protective measures against mechanical
damage caused by accident.
(8) During installation, use the specialized accessories and components, otherwise
water leakage, electric shock or fire hazard may occur.
(9) Please install the air conditioner in a secure place that can withstand the weight
of air conditioner. Insecure installation may cause the air conditioner falling down and lead to injury.
(10) Be sure to adopt independent power circuit. If the power cord is damaged, it
must be repaired by the manufacturer, service agent or other professional agents.
(11) In case of trouble (e.g. burnt smell), please immediately cut off the main power
of air conditioner unit.
(12) The air conditioner can be cleaned only after it is turned off and
power-disconnected, otherwise electric shock may occur.
(13) The air conditioner is not intended to be cleaned or maintained by children
without supervision.
(14) Do not alter the setting of pressure sensor or other protective devices. If the
protective devices are short-circuited or changed against rules, fire hazard or even explosion may occur.
(15) Do not operate the air conditioner with wet hands. Do not wash or sprinkle
water on the air conditioner, otherwise malfunction or electric shock will occur.
(16) Do not dry the filter with naked flame or an air blower; otherwise the filter will be
out of shape.
Rooftop Packaged
3
WARNING
(17) When installing or re-installing the air conditioner, please keep the refrigerant
circuit away from substances other than the specified refrigerant, such as air. Any presence of foreign substances will cause abnormal pressure change or even explosion, resulting in injury.
NOTICE
(1) Do not put a finger or other objects into the air inlet or air return grill.
(2) Please do not foot on or place any goods on air conditioner unit.
(3) Before installation, please check the power supply for compliance with the
ratings on nameplate. Check the power safety as well.
(4) Please adopt safety protection measures before touching the refrigerant pipe,
otherwise your hands may be hurt.
(5) Please arrange the drain pipe according to the instruction manual.
(6) Never stop the air conditioner by directly cutting off the power.
(7) Never install the air conditioner in the following places:
a) Places with oil smoke or volatile liquid: plastic parts may deteriorate and fall
off or even cause water leakage.
b) Places with corrosive gas: copper pipe or the welding parts may be
corroded and cause refrigerant leakage. Places with oil smoke or volatile liquid: plastic parts may deteriorate and fall off or even cause water leakage.
(8) Adopt proper measures to protect the unit from small animals because they
may damage the electric components and cause malfunction of the air conditioner.
(9) The temperature of refrigerant circuit will be high, please keep the
interconnection cable away from the copper tube.
OBSERVED
(1) If wired control is to be used, it should be connected first before powering up
the unit, otherwise the wired control may not be able to use.
(2) Before operating the unit under low temperature, connect it to power for 8
hours. If it is stopped for a short time, for example, one night, do not cut off the power (This is to protect the compressor).
(3) Once started, the air conditioner shall not be stopped at least after 5 minutes or
longer; otherwise the oil return to compressor may be affected.
(4) Please disconnect the main power if to put the air conditioner unit out of use for
a long period.
Rooftop Packaged
4
2 Product Introduction
GREE rooftop packaged units provide a wide capacity range from 3 to 15 Ton. These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant-410a for storage and shipping.
The compact design, attractive appearance, outstanding anti-rust cabinet and quiet operation make these units suitable for almost any manufactured or modular homes,offices,restaurants,residences or similar places.
2.1 Nominal Operating Condition
Item
Outdoor Conditon
Indoor Condition
DB
Temperatrue(°C)
WB
Temperatrue(°C)
DB
Temperatrue(°C)
WB
Temperatrue(°C)
Cooling
35
24
27
19
Heating 7 6
20
15
2.2 Operating Range
GK-H03NH3AS, GK-H5.5NH3AS, GK-H5.5NH3AF,GK-H10NH3AF,GK-H15NH3AF
Item
Outdoor Condition (DB °C)
Cooling
18~48
Heating
-10~24
Rooftop Packaged
5
3 Pre-installation Instruction
3.1 Checking Product Received
Upon receiving the product, check any damage from transportation. Shipping damage is the responsibility of the carrier. Verify the model number, specifications and accessories are correct prior to installation. The distributor or manufacturer will not accept claims from dealers for transportation damage or installation of incorrectly shipped units.
3.2 Standard Accessory Parts
The standard accessory parts listed below are furnished and should be used as required.
No.
Name
Appearance
Q'ty
Usage
1
Wired
Controller
1
To control the unit
3.3 Before Beginning Installation
Carefully read all instructions for the installation prior to installing product. Make sure each step or procedure is understood and any special considerations are taken into account before starting installation. Assemble all tools, hardware and supplies needed to complete the installation. Some items may need to be purchased locally. Make sure everything needed to install the product is on hand before starting.
3.4 Codes & Regulations
This product is designed and manufactured to comply with national codes. It is
installer’s responsibilities to install the product in accordance with such codes
and/or any prevailing local codes/regulations. The manufacturer assumes no responsibilities for equipment installed in violation of any codes or regulations.
3.5 Replacement Parts
When reporting shortages or damages, or ordering repair parts, give the complete product model and serial numbers as stamped on the product.
Loading...