Gree GDN16AH-K4EBB1C, GDN12AH-K4EBB1C, GDN10AH-K4EBB1C, GDN12AH-K4EBB2C, GDN16AH-K4EBB2C Service Manual

...
Service Manual
GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI
Change for Life
Service Manual
Models: GDN10AH-K4EBB1C
GDN10AH-K4EBB2C GDN10AH-K4EBB3C GDN12AH-K4EBB1C GDN12AH-K4EBB2C GDN12AH-K4EBB3C GDN16AH-K4EBB1C GDN16AH-K4EBB2C GDN16AH-K4EBB3C
GDN20AH-K4EBB1C GDN20AH-K4EBB2C GDN20AH-K4EBB3C GDN24AH-K4EBB1C GDN24AH-K4EBB2C GDN24AH-K4EBB3C (Refrigerant R134a)
Service Manual
Table of Contents
Table of Contents
Part
: Technical Information
............................................................ 1
1.Summary
...................................................................................................... 1
2.Specications
........................................................................................... 2
3.Outline Dimension Diagram
............................................................ 11
4.Refrigerant System Diagram
.......................................................... 14
5.Electrical Part
..........................................................................................15
5.1 Wiring Diagram .........................................................................................15
5.2 PCB Printed Diagram ................................................................................ 16
6.Function and Control
.......................................................................... 18
6.1 Control Panel Instruction ........................................................................... 18
6.2 Introduction of Basic Mode Function ......................................................... 19
Part
: Maintenance
............................................................................ 21
7.Notes Maintenance
.............................................................................. 21
8.Maintenance
............................................................................................. 22
8.1 Error Code ................................................................................................. 22
8.2 Malfunction Detection Flowchart ............................................................... 23
8.3 Maintenance Method for Common Malfunction ........................................ 25
9.Exploded View and Parts List
........................................................ 27
10.Removal Procedure
........................................................................... 37
Appendix:
...................................................................................................... 44
Appendix 1: Reference Sheet of Celsius and Fahrenheit ...............................44
Appendix 2: Resistance Table of Temperature Sensor ................................... 45
Appendix 3: Resistance Value Table of Humidity Sensor ............................... 50
1
Service Manual
Installation and Maintenance
1.Summary
Part
: Technical Information
Models
GDN10AH-K4EBB2C GDN12AH-K4EBB2C GDN16AH-K4EBB2C GDN20AH-K4EBB2C GDN24AH-K4EBB2C
GDN10AH-K4EBB3C GDN12AH-K4EBB3C GDN16AH-K4EBB3C GDN20AH-K4EBB3C GDN24AH-K4EBB3C
GDN10AH-K4EBB1C GDN12AH-K4EBB1C GDN16AH-K4EBB1C GDN20AH-K4EBB1C GDN24AH-K4EBB1C
2
Service Manual
Installation and Maintenance
2.Specications
The above data is subject to change without notice; please refer to the nameplate of the unit.
Model GDN10AH-K4EBB1C GDN12AH-K4EBB1C Product Code CK051026100 CK051026200
Power Supply
Rated Voltage V~ 220-240 220-240 Rated Frequency Hz 50 50
Phases 1 1 Rated Dehumidifying Volume L/h 0.17 0.18 Power Input W 220 220 Power Current A 1.20 1.20 Set Humidity Range % 35~80 35~80 Air Flow Volume(H/M/L) m3/h 150/120/100 150/120/100 Fan Motor Speed (H/M/L) r/min 930/800/650 930/800/650 Output of Fan Motor W 6 6 Fan Motor Capacitor μF 1.0 1.0 Fan Type Centrifugal Centrifugal Diameter Length(DXL) mm Φ180X76.5 Φ180X76.5 Throttling Method Capillary Capillary Fuse A 3.15 3.15 Sound Pressure Level (H/M/L) dB (A) 43/41/39 43/41/39 Sound Power Level ((H/M/L) dB (A) 53/51/49 53/51/49 Climate Type T1 T1 Isolation I I Moisture Protection IPX0 IPX0 Permissible Excessive Operating Pressure for the Discharge Side
MPa 1.7 1.7
Permissible Excessive Operating Pressure for the Suction Side
MPa 0.6 0.6
Dimension (WXHXD) mm 343X525X260 343X525X260 Dimension of Carton Box (LXWXH) mm 391X310X569 391X310X569 Dimension of Package (LXWXH) mm 394X313X584 394X313X584 Application Area m
2
14 14 Net Weight kg 13 13 Gross Weight kg 14.5 14.5 Refrigerant R134a R134a Refrigerant Charge kg 0.08 0.09 Bucket Capacity L 4.0/4.6 4.0/4.6 Control Type Electronic Electronic
Evaporator
Form Aluminum Fin-copper Tube Aluminum Fin-copper Tube Pipe Diameter mm Φ7 Φ7 Row-n Gap mm 1-1.3 1-1.3 Coil Length (LXDXW) mm 235X12.7X190.5 235X12.7X190.5
Condenser
Form Aluminum Fin-copper Tube Aluminum Fin-copper Tube Pipe Diameter mm Φ7 Φ7 Rows-n Gap mm 1-1.4 1-1.4 Coil Length (LXDXW) mm 235X12.7X190.5 235X12.7X190.5
Compressor
Compressor Manufacturer/Trademark
Shanghai Hitachi Electrical
Appliances Co.,Ltd/HIGHLY
Shanghai Hitachi Electrical
Appliances Co.,Ltd/HIGHLY Model BSA418CV-R1AUA BSA418CV-R1AUA Type Rotary Rotary Power Input W 213 213 Overload Protector URP-191-78 URP-191-78 L.R.A. A 3.4 3.4 Working Current A 1.2 1.2
3
Service Manual
Installation and Maintenance
The above data is subject to change without notice; please refer to the nameplate of the unit.
Model GDN16AH-K4EBB1C GDN20AH-K4EBB1C Product Code CK051026300 CK051026400
Power Supply
Rated Voltage V~ 220-240 220-240 Rated Frequency Hz 50 50 Phases 1 1
Rated Dehumidifying Volume L/h 0.33 0.41 Power Input W 300 330 Power Current A 1.35 1.50 Set Humidity Range % 35~80 35~80 Air Flow Volume(H/M/L) m3/h 180/160/140 180/160/140 Fan Motor Speed (H/M/L) r/min 950/860/740 950/860/740 Output of Fan Motor W 7 7 Fan Motor Capacitor μF 1.0 1.0 Fan Type Centrifugal Centrifugal Diameter Length(DXL) mm Φ180X76.5 Φ180X76.5 Throttling Method Capillary Capillary Fuse A 3.15 3.15 Sound Pressure Level (H/M/L) dB (A) 45/43/41 45/43/41 Sound Power Level ((H/M/L) dB (A) 55/53/51 55/53/51 Climate Type T1 T1 Isolation I I Moisture Protection IPX0 IPX0 Permissible Excessive Operating Pressure for the Discharge Side
MPa 1.7 1.7
Permissible Excessive Operating Pressure for the Suction Side
MPa 0.6 0.6
Dimension (WXHXD) mm 343X525X260 343X525X260 Dimension of Carton Box (LXWXH) mm 391X310X569 391X310X569 Dimension of Package (LXWXH) mm 394X313X584 394X313X584 Application Area m
2
22.4 23 Net Weight kg 15.0 15.5 Gross Weight kg 16.5 17.0 Refrigerant R134a R134a Refrigerant Charge kg 0.13 0.20 Bucket Capacity L 4.0/4.6 4.0/4.6 Control Type Electronic Electronic
Evaporator
Form Aluminum Fin-copper Tube Aluminum Fin-copper Tube Pipe Diameter mm Φ7 Φ7 Row-n Gap mm 1-1.3 1-1.3 Coil Length (LXDXW) mm 235X12.7X190.5 235X12.7X190.5
Condenser
Form Aluminum Fin-copper Tube Aluminum Fin-copper Tube Pipe Diameter mm Φ7 Φ7 Rows-n Gap mm 1-1.4 2-1.4 Coil Length (LXDXW) mm 235X12.7X190.5 235X12.7X190.5
Compressor
Compressor Manufacturer/Trademark
RECHI PRECISION CO.,LTD/
RECHI
RECHI PRECISION CO.,LTD/
RECHI Model 39E0G3HR&F^YA 39E0G3HR&F^YA Type Rotary Rotary Power Input W 213 213 Overload Protector UP3-016 UP3-017 L.R.A. A 3.4 3.4 Working Current A 1.2 1.4
4
Service Manual
Installation and Maintenance
The above data is subject to change without notice; please refer to the nameplate of the unit.
Model GDN24AH-K4EBB1C Product Code CK051026500
Power Supply
Rated Voltage V~ 220-240 Rated Frequency Hz 50 Phases 1
Rated Dehumidication Capacity L/h 0.50 Power Input W 330 Current Input A 1.50 Set Humidity Range % 35~80 Air Flow Volume(H/M/L) m3/h 180/160/140 Fan Motor Speed(H/M/L) r/min 1150/1000/850 Fan Motor Power Output W 10 Fan Motor RLA A 0.16 Fan Motor Capacitor μF 1.5 Fan Type Centrifugal Fan Diameter Length(DXL) mm Φ180X76.5 Throttling Method Capillary Fuse Current A 3.15 Sound Pressure Level(H/M/L) dB (A) 47/45/43 Sound Power Level(H/M/L) dB (A) 57/55/53 Climate Type T1 Isolation I Moisture Protection IPX0 Permissible Excessive Operating Pressure for the Discharge Side
MPa 1.7
Permissible Excessive Operating Pressure for the Suction Side
MPa 0.6
Dimension (WXHXD) mm 343X525X260 Dimension of Carton Box(LXWXH) mm 391X310X569 Dimension of Package(LXWXH) mm 394X313X584 Application Area m
2
33.6 Net Weight kg 16 Gross Weight kg 17.5 Refrigerant R134a Refrigerant Charge kg 0.24 Bucket Capacity L 4.0/4.6 Control Type Electronic
Evaporator
Evaporator Form Aluminum Fin-copper Tube Evaporator Pipe Diameter mm Φ7 Evaporator Row-n Gap mm 2-1.3 Evaporator Coil Length (LXDXW) mm 235X25.4X190.5
Condenser
Condenser Form Aluminum Fin-copper Tube Condenser Pipe Diameter mm Φ7 Condenser Rows-n Gap mm 2-1.4 Condenser Coil Length (LXDXW) mm 235X25.4X190.5
Compressor
Compressor Manufacturer RECHI PRECISION CO.,LTD/RECHI Compressor Model 39E073HR&F^YA Compressor Type Rotary Compressor Power Input W 300 Compressor Overload Protector UP3-017 Compressor LRA. A 5.5 Compressor RLA A 1.4
5
Service Manual
Installation and Maintenance
The above data is subject to change without notice; please refer to the nameplate of the unit.
Model GDN10AH-K4EBB2C GDN12AH-K4EBB2C Product Code CK051024000 CK051025000
Power Supply
Rated Voltage V~ 220-240 220-240 Rated Frequency Hz 50 50
Phases 1 1 Rated Dehumidifying Volume L/h 0.17 0.18 Power Input W 220 220 Power Current A 1.20 1.20 Set Humidity Range % 35~80 35~80 Air Flow Volume(H/M/L) m3/h 150/120/100 150/120/100 Fan Motor Speed (H/M/L) r/min 930/800/650 930/800/650 Output of Fan Motor W 6 6 Fan Motor Capacitor μF 1.0 1.0 Fan Type Centrifugal Centrifugal Diameter Length(DXL) mm Φ180X76.5 Φ180X76.5 Throttling Method Capillary Capillary Fuse A 3.15 3.15 Sound Pressure Level (H/M/L) dB (A) 43/41/39 43/41/39 Sound Power Level ((H/M/L) dB (A) 53/51/49 53/51/49 Climate Type T1 T1 Isolation I I Moisture Protection IPX0 IPX0 Permissible Excessive Operating Pressure for the Discharge Side
MPa 1.7 1.7
Permissible Excessive Operating Pressure for the Suction Side
MPa 0.6 0.6
Dimension (WXHXD) mm 343X525X262 343X525X262 Dimension of Carton Box (LXWXH) mm 391X310X569 391X310X569 Dimension of Package (LXWXH) mm 394X313X584 394X313X584 Application Area m
2
14 14 Net Weight kg 13 13 Gross Weight kg 14.5 14.5 Refrigerant R134a R134a Refrigerant Charge kg 0.08 0.09 Bucket Capacity L 4.0/4.6 4.0/4.6 Control Type Electronic Electronic
Evaporator
Form Aluminum Fin-copper Tube Aluminum Fin-copper Tube Pipe Diameter mm Φ7 Φ7 Row-n Gap mm 1-1.3 1-1.3 Coil Length (LXDXW) mm 235X12.7X190.5 235X12.7X190.5
Condenser
Form Aluminum Fin-copper Tube Aluminum Fin-copper Tube Pipe Diameter mm Φ7 Φ7 Rows-n Gap mm 1-1.4 2-1.4 Coil Length (LXDXW) mm 235X12.7X190.5 235X12.7X190.5
Compressor
Compressor Manufacturer/Trademark
Shanghai Hitachi Electrical
Appliances Co.,Ltd/HIGHLY
Shanghai Hitachi Electrical
Appliances Co.,Ltd/HIGHLY Model BSA418CV-R1AUA BSA418CV-R1AUA Type Rotary Rotary Power Input W 213 213 Overload Protector URP-191-78 URP-191-78 L.R.A. A 3.4 3.4 Working Current A 1.1 1.1
6
Service Manual
Installation and Maintenance
The above data is subject to change without notice; please refer to the nameplate of the unit.
Model GDN16AH-K4EBB2C GDN20AH-K4EBB2C Product Code CK051023700 CK051023800
Power Supply
Rated Voltage V~ 220-240 220-240 Rated Frequency Hz 50 50 Phases 1 1
Rated Dehumidifying Volume L/h 0.33 0.41 Power Input W 300 300 Power Current A 1.35 1.5 Set Humidity Range % 35~80 35~80 Air Flow Volume(H/M/L) m3/h 180/160/140 180/160/140 Fan Motor Speed (H/M/L) r/min 950/860/740 950/860/740 Output of Fan Motor W 7 7 Fan Motor RLA A 0.13 0.13 Fan Motor Capacitor μF 1 1 Fan Type Centrifugal Centrifugal Diameter Length(DXL) mm Φ180X76.5 Φ180X76.5 Throttling Method Capillary Capillary Fuse A 3.15 3.15 Sound Pressure Level (H/M/L) dB (A) 45/43/41 45/43/41 Sound Power Level ((H/M/L) dB (A) 55/53/51 55/53/51 Climate Type T1 T1 Isolation I I Moisture Protection IPX0 IPX0 Permissible Excessive Operating Pressure for the Discharge Side
MPa 1.7 1.7
Permissible Excessive Operating Pressure for the Suction Side
MPa 0.6 0.6
Dimension (WXHXD) mm 343X525X262 343X525X262 Dimension of Carton Box (LXWXH) mm 391X310X569 391X310X569 Dimension of Package (LXWXH) mm 394X313X584 394X313X584 Application Area m
2
22.4 28 Net Weight kg 15 15.5 Gross Weight kg 16.5 17 Refrigerant R134a R134a Refrigerant Charge kg 0.13 0.2 Bucket Capacity L 4.0/4.6 4.0/4.6 Control Type Electronic Electronic
Evaporator
Form Aluminum Fin-copper Tube Aluminum Fin-copper Tube Pipe Diameter mm Φ7 Φ7 Row-n Gap mm 1-1.3 1-1.3 Coil Length (LXDXW) mm 235X12.7X190.5 235X12.7X190.5
Condenser
Form Aluminum Fin-copper Tube Aluminum Fin-copper Tube Pipe Diameter mm Φ7 Φ7 Rows-n Gap mm 1-1.4 2-1.4 Coil Length (LXDXW) mm 235X12.7X190.5 235X12.7X190.5
Compressor
Compressor Manufacturer/Trademark
RECHI PRECISION CO.,LTD/
RECHI
RECHI PRECISION CO.,LTD/
RECHI Model 39E0G3HR&F^YA 39E073HR&F^YA Type Rotary Rotary Power Input W 265 300 Overload Protector UP3-016 UP3-017 L.R.A. A 5.5 5.5 Working Current A 1.2 1.4
7
Service Manual
Installation and Maintenance
The above data is subject to change without notice; please refer to the nameplate of the unit.
Model GDN24AH-K4EBB2C Product Code CK051023900
Power Supply
Rated Voltage V~ 220-240 Rated Frequency Hz 50 Phases 1
Rated Dehumidication Capacity L/h 0.50 Power Input W 330 Current Input A 1.50 Set Humidity Range % 35~80 Air Flow Volume(H/M/L) m3/h 180/160/140 Fan Motor Speed(H/M/L) r/min 1150/1000/850 Fan Motor Power Output W 10 Fan Motor RLA A 0.16 Fan Motor Capacitor μF 1.5 Fan Type Centrifugal Fan Diameter Length(DXL) mm Φ180X76.5 Throttling Method Capillary Fuse Current A 3.15 Sound Pressure Level(H/M/L) dB (A) 47/45/43 Sound Power Level(H/M/L) dB (A) 57/55/53 Climate Type T1 Isolation I Moisture Protection IPX0 Permissible Excessive Operating Pressure for the Discharge Side
MPa 1.7
Permissible Excessive Operating Pressure for the Suction Side
MPa 0.6
Dimension (WXHXD) mm 343X525X262 Dimension of Carton Box(LXWXH) mm 391X310X569 Dimension of Package(LXWXH) mm 394X313X584 Application Area m
2
33.6 Net Weight kg 16 Gross Weight kg 17.5 Refrigerant R134a Refrigerant Charge kg 0.24 Bucket Capacity L 4.0/4.6 Control Type Electronic
Evaporator
Evaporator Form Aluminum Fin-copper Tube Evaporator Pipe Diameter mm Φ7 Evaporator Row-n Gap mm 2-1.3 Evaporator Coil Length (LXDXW) mm 235X25.4X190.5
Condenser
Condenser Form Aluminum Fin-copper Tube Condenser Pipe Diameter mm Φ7 Condenser Rows-n Gap mm 2-1.4 Condenser Coil Length (LXDXW) mm 235X25.4X190.5
Compressor
Compressor Manufacturer RECHI PRECISION CO.,LTD/RECHI Compressor Model 39E073HR&F^YA Compressor Type Rotary Compressor Power Input W 300 Compressor Overload Protector UP3-017 Compressor LRA. A 5.5 Compressor RLA A 1.4
8
Service Manual
Installation and Maintenance
Model GDN10AH-K4EBB3C GDN12AH-K4EBB3C Product Code CK051026000 CK051025800
Power Supply
Rated Voltage V~ 220-240 220-240 Rated Frequency Hz 50 50
Phases 1 1 Rated Dehumidifying Volume L/h 0.17 0.18 Power Input W 220 220 Power Current A 1.20 1.20 Set Humidity Range % 35~80 35~80 Air Flow Volume(H/M/L) m3/h 150/120/100 150/120/100 Fan Motor Speed (H/M/L) r/min 950/860/740 950/860/740 Output of Fan Motor W 6 6 Fan Motor Capacitor μF 1.0 1.0 Fan Type Centrifugal Centrifugal Diameter Length(DXL) mm Φ180X76.5 Φ180X76.5 Throttling Method Capillary Capillary Fuse A 3.15 3.15 Sound Pressure Level (H/M/L) dB (A) 43/41/39 43/41/39 Sound Power Level ((H/M/L) dB (A) 53/51/49 53/51/49 Climate Type T1 T1 Isolation I I Moisture Protection IPX0 IPX0 Permissible Excessive Operating Pressure for the Discharge Side
MPa 1.7 1.7
Permissible Excessive Operating Pressure for the Suction Side
MPa 0.6 0.6
Dimension (WXHXD) mm 343X525X270 343X525X270 Dimension of Carton Box (LXWXH) mm 391X310X569 391X310X569 Dimension of Package (LXWXH) mm 394X313X584 394X313X584 Application Area m
2
14 14 Net Weight kg 13 13 Gross Weight kg 14.5 14.5 Refrigerant R134a R134a Refrigerant Charge kg 0.13 0.20 Bucket Capacity L 4.0/4.6 4.0/4.6 Control Type Electronic Electronic
Evaporator
Form Aluminum Fin-copper Tube Aluminum Fin-copper Tube Pipe Diameter mm Φ7 Φ7 Row-n Gap mm 1-1.3 1-1.3 Coil Length (LXDXW) mm 235X12.7X190.5 235X12.7X190.5
Condenser
Form Aluminum Fin-copper Tube Aluminum Fin-copper Tube Pipe Diameter mm Φ7 Φ7 Rows-n Gap mm 1-1.4 1-1.4 Coil Length (LXDXW) mm 235X12.7X190.5 235X12.7X190.5
Compressor
Compressor Manufacturer/Trademark
Shanghai Hitachi Electrical
Appliances Co.,Ltd
Shanghai Hitachi Electrical
Appliances Co.,Ltd Model BSA418CV-R1AUN BSA418CV-R1AUN Type Rotary Rotary Power Input W 213 213 Overload Protector UP3-016 URP-191-78 L.R.A. A 3.4 3.4 Working Current A 1.1 1.1
The above data is subject to change without notice; please refer to the nameplate of the unit.
9
Service Manual
Installation and Maintenance
Model GDN16AH-K4EBB3C GDN20AH-K4EBB3C Product Code CK051025900 CK051025600
Power Supply
Rated Voltage V~ 220-240 220-240 Rated Frequency Hz 50 50 Phases 1 1
Rated Dehumidifying Volume L/h 0.33 0.41 Power Input W 300 330 Power Current A 1.35 1.50 Set Humidity Range % 35~80 35~80 Air Flow Volume(H/M/L) m3/h 180/160/140 180/160/140 Fan Motor Speed (H/M/L) r/min 950/860/740 950/860/740 Output of Fan Motor W 7 7 Fan Motor Capacitor μF 1.0 1.0 Fan Type Centrifugal Centrifugal Diameter Length(DXL) mm Φ180X76.5 Φ180X76.5 Throttling Method Capillary Capillary Fuse A 3.15 3.15 Sound Pressure Level (H/M/L) dB (A) 45/43/41 45/43/41 Sound Power Level ((H/M/L) dB (A) 55/53/51 55/53/51 Climate Type T1 T1 Isolation I I Moisture Protection IPX0 IPX0 Permissible Excessive Operating Pressure for the Discharge Side
MPa 1.7 1.7
Permissible Excessive Operating Pressure for the Suction Side
MPa 0.6 0.6
Dimension (WXHXD) mm 343X525X270 343X525X270 Dimension of Carton Box (LXWXH) mm 391X310X569 391X310X569 Dimension of Package (LXWXH) mm 394X313X584 394X313X584 Application Area m
2
22.4 28 Net Weight kg 15.0 15.5 Gross Weight kg 16.5 17.0 Refrigerant R134a R134a Refrigerant Charge kg 0.13 0.20 Bucket Capacity L 4.0/4.6 4.0/4.6 Control Type Electronic Electronic
Evaporator
Form Aluminum Fin-copper Tube Aluminum Fin-copper Tube Pipe Diameter mm Φ7 Φ7 Row-n Gap mm 1-1.3 1-1.3 Coil Length (LXDXW) mm 235X12.7X190.5 235X12.7X190.5
Condenser
Form Aluminum Fin-copper Tube Aluminum Fin-copper Tube Pipe Diameter mm Φ7 Φ7 Rows-n Gap mm 1-1.4 2-1.4 Coil Length (LXDXW) mm 235X12.7X190.5 235X12.7X190.5
Compressor
Compressor Manufacturer/Trademark
RECHI PRECISION CO.,LTD/
RECHI
RECHI PRECISION CO.,LTD/
RECHI Model 39E0G3HR&F^YA 39E0G3HR&F^YA Type Rotary Rotary Power Input W 213 213 Overload Protector UP3-016 URP-191-78 L.R.A. A 3.4 3.4 Working Current A 1.2 1.4
The above data is subject to change without notice; please refer to the nameplate of the unit.
10
Service Manual
Installation and Maintenance
The above data is subject to change without notice; please refer to the nameplate of the unit.
Model GDN24AH-K4EBB3C Product Code CK051025700
Power Supply
Rated Voltage V~ 220-240 Rated Frequency Hz 50 Phases 1
Rated Dehumidication Capacity L/h 0.50 Power Input W 330 Current Input A 1.50 Set Humidity Range % 35~80 Air Flow Volume(H/M/L) m3/h 180/160/140 Fan Motor Speed(H/M/L) r/min 1150/1000/850 Fan Motor Power Output W 10 Fan Motor RLA A 0.16 Fan Motor Capacitor μF 1.5 Fan Type Centrifugal Fan Diameter Length(DXL) mm Φ180X76.5 Throttling Method Capillary Fuse Current A 3.15 Sound Pressure Level(H/M/L) dB (A) 47/45/43 Sound Power Level(H/M/L) dB (A) 57/55/53 Climate Type T1 Isolation I Moisture Protection IPX0 Permissible Excessive Operating Pressure for the Discharge Side
MPa 1.7
Permissible Excessive Operating Pressure for the Suction Side
MPa 0.6
Dimension (WXHXD) mm 343X525X270 Dimension of Carton Box(LXWXH) mm 391X310X569 Dimension of Package(LXWXH) mm 394X313X584 Application Area m
2
33.6 Net Weight kg 16 Gross Weight kg 17.5 Refrigerant R134a Refrigerant Charge kg 0.24 Bucket Capacity L 4.0/4.6 Control Type Electronic
Evaporator
Evaporator Form Aluminum Fin-copper Tube Evaporator Pipe Diameter mm Φ7 Evaporator Row-n Gap mm 2-1.3 Evaporator Coil Length (LXDXW) mm 235X25.4X190.5
Condenser
Condenser Form Aluminum Fin-copper Tube Condenser Pipe Diameter mm Φ7 Condenser Rows-n Gap mm 2-1.4 Condenser Coil Length (LXDXW) mm 235X25.4X190.5
Compressor
Compressor Manufacturer RECHI PRECISION CO.,LTD/RECHI Compressor Model 39E073HR&F^YA Compressor Type Rotary Compressor Power Input W 300 Compressor Overload Protector UP3-017 Compressor LRA. A 5.5 Compressor RLA A 1.4
11
Service Manual
Installation and Maintenance
3.Outline Dimension Diagram
525
260
343
unit:mm
GDN10AH-K4EBB1C GDN12AH-K4EBB1C GDN16AH-K4EBB1C GDN20AH-K4EBB1C GDN24AH-K4EBB1C
12
Service Manual
Installation and Maintenance
262
525
343
unit:mm
GDN10AH-K4EBB2C GDN12AH-K4EBB2C GDN16AH-K4EBB2C GDN20AH-K4EBB2C GDN24AH-K4EBB2C
13
Service Manual
Installation and Maintenance
unit:mm
343
525
270
GDN10AH-K4EBB3C GDN12AH-K4EBB3C GDN16AH-K4EBB3C GDN20AH-K4EBB3C GDN24AH-K4EBB3C
14
Service Manual
Installation and Maintenance
4.Refrigerant System Diagram
air in
evaporator
capillary
condenser
fan motor
air out
compressor
Dehumidifying principle of dehumidier:
When temperature is decreased to the temperature point of dew, water vapor in humid air will condensate. Dehumidier is dehumidifying the air by using this principle. During operation of the system, air will pass through evaporator and condenser in turn and then be discharged due to centrifugal blade. When the air is passing through evaporator, refrigerant will absorb the heat in air to let its temperature decrease to the temperature point of dew, water vapor in air will condensate. Condensate water comes into water tank through water tray, or is discharged directly through drainage hose. The saturated low-temperature air passed through the evaporator will absorb the heat when owing along the condenser, and then become the dry air. Under normal condition, the nearby air will become warm during operation of dehumidier.
15
Service Manual
Installation and Maintenance
Symbol Symbol Color Symbol Symbol Color Symbol Name
WH White GN Green COMP Compressor
YE Yellow BN Brown Grounding wire
RD Red BU Blue / /
YEGN Yellow/Green BK Black / /
VT Violet OG Orange / /
5.Electrical Part
5.1 Wiring Diagram
●Instruction
These circuit diagrames are subject to change without notice ,please refer to the one supplied with the unit.
PE
YEGN
CN4
SENSOR
ST
HUMIDITY
AC-L
YEGN
C1
C
RD
YEGN(GN)
BU(WH)
BN(BK)
CN1
AP2
CN1
CN3
AP1
L
N
COMP.
M
WATER LEVEL SWITCH
N1
PE
POWER
FAN
MOTOR
PE
YEGN
PE
COMP
SA
COM
NO
BU
BN
CN2
K1
N
PE
TUBE
RT1
TUBE
TEMP.SENSOR
ELECTRIC
BOX
C2
YE
BU
BU
R
S
16
Service Manual
Installation and Maintenance
Silk Screen on Main Board
5.2 PCB Printed Diagram
● Top view
● Bottom view
No. Name Description No. Name Description
1
Needle stand of board connection wire
Connect to display board 4 Interface of neutral wire
Connect to neutral wire of commercial wire
2 Needle stand of fan Connect to fan 5 Interface of compressor Connect to compressor
3 Interface of live wire
Connect to live wire of commercial wire
6
Needle stand of water blow protection switch
Connect to water blow protection switch
6 3 5
4
1
2
Loading...