Gree G1407R, G1409R, G1412R, G1418R Operating Instructions Manual

Window type Air Conditioner
Models:
G1407R G1409R
G1412R G1418R
Please read this operating manual care­fully before operating the unit ……
Thank you for choosing GREE air conditioner. Our design is based on the best efficiency and the lowest
CONTENTS
Function
Operating condition
power requirement
Installation
Notes for installation
Part identification 7
Air direction adjustment 7
Operation tips 14
Caution 15
Care and maintenance 16
Trouble shooting guide 17
Structure mechanism and Installation
Operation of wireless remote control 8
Operation procedure
Care and maintenance
2
2
3
6
1
The figures in this manual may be different with the material objects,
please refer to the material objects for reference.
After service 18
1
Function
Introduction
Window type room air conditioners of GREE can regulate the room temperature and dry the room. It is convenient for your work,study and life. It can be widely used in residence, shop, hotel, office, library and laboratory, and so on.
Room temp.
Spring
Summer
Autumn
Wind direction
Winter
Cooling in summer
In hot summer, Air conditioner can cool down the room air by transferring heat out.
Without reducing the room temp., air conditioner can dehumidify and make the room air dry and comfortable.
Dehumidifying in rainy or humid season
Exchange fresh air
Open storm door to keep the fresh air in the room.
Dry
Fresh Air
Heating in winter
In cold winter, Air conditioner can heat up room air.
(Only for heat unit)
2
Operating Condition
Please operate air conditioner in the correct conditions as following.
Power requirement
COOL mode operation
DRY mode operation
Outdoor temperature should be in range of 18 to 43 , otherwise it is possible for air conditioner to breakdown.
Outdoor temperature should be in range of 18 to 43 , otherwise it is possible for air conditioner to breakdown. Room humidity should be lower than 90%. Otherwise, it is possible for air conditioner to dew at air conditioner surface and even drop water af­ter running for so much time. But this is normal.
Water pipe
Rated voltage and voltage range:
220V 10%
The electric components will be damaged when the voltage is too high.
If the voltage is too low, the compressor will vibrate violently to dam­age the refrigerant system and easily cause the compressor and elec­tric components not work.
The ground must be connected. Special socket must be used. Furthermore, the socket and wiring must conform to the wiring regulations. And the earthing method must be reliable. In fixed circuit, there must be electricity leakage protection switch of enough power capacity and air switch with enough space.
Earth wire To ensure the reliable earthing, please do not connect earth wire to the following places:
The distance of obstructions from window unit inside should be upper 300mm, lower 1500mm,
left 500mm,right 500mm, front1500mm.
3
Installation
Installation precaution:
Window type conditioner is so valuable and the improper installa­tion of it will cause a lot of damage! Please associate the profes­sional technician to install the unit and don’t install it by yourself. Otherwise, we are not responsible for the damage like this.
Location:
The condensation water must be drained away conveniently.
Install air conditioner unit far away from TV set or radio etc. to avoid disturbing video or voice.
In salt and coastal area or place where is near thermal springs and polluted by sulphurous gas, or other special areas, please contact the seller before use.
Avoid a place where is possible for inflammable gas to leak out.
Avoid other heat sources or direct sun light. Avoid a place where is easy for children to touch.
For window type air conditioner with remote
control, install in a location where is strong elec­tromagnetic disturbance, you should contact the seller in advance to avoid the malfunction in use.
How to install:
Choose a location where there are no any obstacle surrounding
the unit, and the plug is accessible. Prepare the installation hole slightly bigger than unit size. Choose the installation space according to the following diagram.
Don't use the unit in the immediate surrondings of
a laundry,a bath,a shower or a swimming pool.
Sunshade board
Wall
Wooden frame
Rubber plate
Support
4
Horizontal line
Horizontal line
Installation procedure:
1) Remove the sticker from the front panel.
2) Put the unit into the installation hole. When installing the unit, it should be slanted down to the back to avoid the enlargement of noise or vibration. (Slant between 6-10mm.) (Shown at right figure.) The installation place should be strong enough to avoid the enlargement of noise or vibration.
3) Fill up sews in the cabinet with sponge or foam.
Installation assistance:
Use iron support The installation hole should be strong enough to support the air conditioner. If it cannot, iron sup­port has to be used outdoors. Iron support should be fixed on the building (Shown at right figure.) Use sunshade board Air conditioner should avoid anything to be dropped into it and avoid direct sunshine. If there is no cover on it, you should contact the seller for installing the sunshade board. When installing the sunshade board, don’t let it block the air inlet at the side grille.