Gree ForestAir 13-04588, ForestAir 13-04590, ForestAir 13-04592, ForestAir 13-04591, ForestAir 13-04593 Owner's Manual

OWNER’S MANUAL
WINDOW AIR CONDITIONER
MODELS
13-04588/13-04590/13-04591/13-04592/13-04593
00217-07/12/06
Please read the following owner’s manual before using this air conditioner. Keep this manual along with your proof of purchase in a safe place for future reference.
by
2
TABLE OF CONTENTS
USE ....................................................................3
SAFETY NOTES ....................................................3
INSTALLATION
Accessories and hardware............................ 4
Tools needed................................................ 4
Unpacking the air conditioner........................5
Electrical requirements ..................................5
Recommendations ........................................5
Window requirements .................................. 6
Preparation of air conditioner ....................6-7
Completing the installation ............................7
UNIT OPERATION Electronic control models
LCD display control panel .......................... 8
Cooling.........................................................9
Fan only .......................................................9
Power saver mode ......................................10
Setting the timer..........................................10
Filter cleaning warning light ........................10
Remote Control ...........................................11
M
ECHANICAL CONTROL MODELS ..................................12
CHANGING AIR DIRECTION ..............................12
MAINTENANCE
Cleaning the filter .......................................13
Cleaning the housing...................................13
Storage.......................................................13
NOISES AND VIBRATIONS .................................13
TROUBLESHOOTING ..........................................14
ROOM COOLING CHART ..................................15
CUSTOMER SERVICE INFORMATION ..................15
WARRANTY............................................................ 16
WARNING
Please read the following owner’s manual before using this air conditioner. This manual is not a contract and should be used as a reference guide only. We reserve the right to make technical changes at all times without prior notice.
USE
Thank you for purchasing this air conditioner. This unit is designed to improve indoor living and working comfort by providing cooling and ventilation with minimal installation. Please refer to the Room Cooling Chart at the end of this manual for the room size to cool vs the capacity of your new air conditioner.
SAFETY NOTES
When using this air conditioner, or any other electric appliance, always follow these basic safety precautions. Not doing so could result in injuries, electrical shocks or fire.
1. The unit must be connected to a grounded (three prongs) power supply properly rated. For your safety, this unit is grounded through the power cord plug when connected to a grounded wall outlet.
2. Do not alter the power cord nor the plug end by removing the ground prong.
3. It is recommended not to use an adaptor plug or extension cord.
4. Do not plug the unit in a damaged electrical receptacle.
5. Do not connect the unit to an outlet that is being used for other electrical appliances.
6. Before unplugging the unit, always turn it off. Always unplug the unit before cleaning or
servicing. When unplugging the unit, never pull on the power cord - always grip the plug.
7. Do not start or stop the unit by plugging in or pulling out the power cord.
8. Always check the power cord for signs of damage before use. If the power cord is damaged,
contact SUNRISE TRADEX Customer Service.
9. Do not install or use the unit in the following places:
• near a heat source;
• an area with possible gas leakage or in an explosive atmosphere ;
• near a bath, shower enclosure, swimming pool, or any other steamy and wet areas ;
• in a greenhouse.
10. Do not apply insecticides or any other flammable products on the unit.
11. Do not operate with wet hands or spray water or other liquid on the unit, nor immerse the
appliance.
12. This unit is not intended for the use of children and close supervision is necessary when it is operating near children.
13. Never insert fingers, foreign objects, or anything to obstruct the air inlet and outlet grills. Warn children.
14. Never operate with an outside protective cover in place or other objects blocking the outside airflow.
15. For a maximum efficiency, do not block inside airflow with curtains, blinds, furniture or else.
16. Do not expose skin or eyes directly to cool air over a long period of time.
17. Ensure that all parts and accessories are correctly fitted before turning on the unit.
18. If an abnormal odour or smoke comes out of the unit, immediately unplug the unit and contact
SUNRISE TRADEX Customer Service.
19. Do not place a plant or allow a pet to be exposed directly to the unit cool airflow.
20. Do not put any combustion appliance in the direct path of the unit airflow ; it could affect the
combustion efficiency.
3
4
INSTALLATION
ACCESSORIES (PRODUCTS MAY DIFFER FROM THE DIAGRAMS)
Before beginning to install, make sure to have close at hand all the tools you will need (listed below) and that all accessories and hardware parts provided with your air conditioner (as shown) are all included.
Top mounting rail
Window foam gasket
Right
expandable
panel
Tools needed
A. Level B. Gloves C. Flat blade and Phillips screwdrivers D. Utility knife E. Drill with 3/32” bit or smaller F. Safety glasses G. Tape measure
Hardware (included)
H. Window-lock bracket I. Foam adhesive sealer J. #8 x 3/8” round head Phillips screws (6) K. #8 x 3/4” slot head wood screws (3)
H
A
B
C
D
E
F
G
I K
J
Air
conditioner
Left
expandable
panel
5
IMPORTANT NOTICE :
Do not pierce the bottom of the air conditioner. Excess water is accumulated to cool down the temperature of the capacitor (outdoor unit). It is normal to hear the capacitor’s blade hit water accumulated in the bottom of the unit. Not respecting this notice will automatically void the warranty of the unit.
NOTE : Drawing of the air conditioner and accessories may differ from the products.
UNPACKING THE AIR CONDITIONER
Remove the air conditioner from the packing carton. It is recommended to keep the carton and packing material for storage or transportation of the unit. If you decide to dispose of the packing material, waste recycling where possible.
Remove tape and glue residue from surface before turning on the air conditioner. Rub a small amount of liquid dish soap over the glue residue with your fingers. Wipe with warm water and dry.
• Do not use sharp instruments, rubbing alcohol, flammable fluids, or abrasive cleaners to remove tape or glue. These products can damage the surface of your air conditioner.
• Handle the air conditioner with care. We recommend that 2 persons move and install this air conditioner.
ELECTRICAL REQUIREMENTS
The electrical ratings for your air conditioner are listed on the rating plate of your unit.
• Specific electrical requirements are listed in the chart below. Make sure to follow the requirements for the type of plug ending the power supply cord.
•The air conditioner must be grounded ; it is equipped with a power supply cord ending with a grounded plug (3 prongs) and must be plugged into a properly rated 3-prong grounded outlet.
• If you do not have a grounded outlet available, contact a qualified electrician to have a grounded outlet properly installed.
• Do not alter the power supply plug by removing the ground plug.
RECOMMENDATIONS
Make sure you install the air conditioner in a window that will hold the weight and secure the unit as per the instructions.
• The weight may vary from 22 to 40 kg (48 to 88 lbs). Check the rating label on your unit or the packing box to get the exact weight of your air conditioner.
• For a safe and solid installation, make sure you follow closely the instructions detailed in the next pages.
INSTALLATION
- 115V (103,5 min. - 126,5 max.)
- 0-12A
- 15A time-delay fuse or circuit breaker