Gree ETAC-07HC230V20A-A, ETAC-07HP230V20A-A, ETAC-09HC230V20A-A, ETAC-09HP230V20A-A, ETAC-09HP265V20A-A Installation Guide

...
Instal
\
NOTE TO EQUIPMENT OWNER:
Thank you for purchasing a Gree E-TAC. Please read this Owner's Information Manual carefully before installing and using this appliance. Keep this manual for future reference.
For your convenience, please record the model and serial numbers of your new equipment in the
spaces provided. This information, along with the installation data and dealer contact information,
will be helpful should your system require maintenance or service.
Serial #
INSTALLATION INFORMATION Date Installed
DEALERSHIP CONTACT INFORMATION Company Name:
Address:
Phone Number: Technician Name:
TABLE OF CONTENTS
PAGE
SAFETY CONSIDERATIONS ........................................................................... 3
GENERAL INFORMATION ............................................................................. 3
UNIT FEATURES .................................................................................. 4 - 5
ELECTRICAL DATA .................................................................................. 6
INS'FALLATION
Chassis Installation ............................................................................. 7
Retrofit Sleeve Preparation ....................................................................... 8
Installation of"Gree Wall Sleeve Using Non-Gree Grille ................................................. 8
Insta11Unit Into Wall Sleeve ...................................................................... 9
SYSTEM CONFIGURATION
Ventilation Control ............................................................................ 10
Adjusting Air Direction ......................................................................... 10
Dipswitches .................................................................................. 11
Keypad Configuration .......................................................................... 12
AUXILIARY CONTROLS
Wall Thermostat Terminal ...................................................................... 14
Energy Management Input ...................................................................... 14
Intelligent Self-Checking Control ................................................................. 14
OPERATION ........................................................................................ 15
CARE AND CLEANING ............................................................................... 16
PREVENTATIVE MAINTENANCE ...................................................................... 17
TROUBLESHOOTING ............................................................................. 18-22
WARRANTY ..................................................................................... 23 - 24
NOTE: Warranty coverage documented on back page of owners manua!
UNIT INSPECTION
Examine unit for damage incurred during shipment. File a claim immediately with the transit
company if damage is found.
READ ALL INSTRUCTIONS BEFORE INSTALLATION OR USE
SAFETY CONSIDERATIONS
Recognize safety information. This is the safety-alert
symbol _. When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury.
Understand these signal words: DANGER, WARNING, and CAUTION. These words are used with the safety=alert symbol. DANGER identifies the
most serious hazards which will result in severe personalinjury or death. WARNING signifies hazards
which could result in personal injury or death.
CAUTION is used to identify unsafe practices which
may result in minor personal injury or product and
property damage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability, or operation.
PERSONAL INJURY AND/OR PROPERTY DAMAGE
HAZARD
Failure to %llow this warning could result in personal injury, death and/or property damage.
For your safety, the information in this manual must be fbllowed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss
of life.
* This unit must be properly installed in accordance
with the Installation Instructions before it is used.
* Immediately repair or replace all electric service
cords that have become frayed or otherwise damaged.
* Unplug or disconnect the unit at the fuse box or
circuit breaker before making any repairs.
GENERAL
Thank you for choosing the Gree E-TAC! You can feel confident in your selection because of the pride in craftsmanship and engineering knowledge that goes into this equipment.
Gree package terminal air conditioners and heat pumps provide a high standard of quality in performance, workmanship, durability and
appearance as they heat and cool the occupied air
space year round.
This manual provides information for ease of
installation, operation and maintenance. All models are designed for through-the-wall
installatiom Separate installation instructions are
included with all accessory components.
BEFORE YOU BEGIN Read these instructions completely and carefully.
IMPORTANT: Save these instructions for local inspector's use.
IMPORTANT: Observe aH governing codes and
ordinances.
NOTE TO INSTALLER Be sure to leave these instructions with the owner.
NOTE TO OWNER
Keep these instructions for future reference. Be sure to write down the model and serial number of unit on
space provided on front page. The model and serial number can be located on the serial number plate
attached to unit.
NOTE: We strongly recommend that any servicing be performed by a qualified individual.
UNIT FEATURES
Fig. 2 - E-TAC Front Panel
This E-TAC has many exciting features which are different than those found on standard PTAC models. The owner must be familiar with these
features in order to fully understand the operation and capability of the unit.
* Intelligence - Your E-TAC unit has an on board computer that utilizes real time diagnostics to prolong the life of your unit. There is an LED indicator on the control board, behind the front panel, that will flash
an error code if the unit has detected some kind of fault condition. In many cases, the unit will
automatically clear the fault condition and continue operating with no interruption. In some cases, the condition cannot be cleared and the unit will require service. In those cases, an "Fx" failure mode will be displayed on the digital display. For a detailed list of
all error codes and "Fx" conditions, see Table 6 = Stattts LED Indicator D@'nitions for further details.
* Memory - Your E-TAC unit also has memory. If power is lost, all of the control settings (setpoint, mode, fan speed, on/off and configuration) are remembered. So when power is restored, the unit -will start back up in the mode (and configuration) it was
in, when power was lost. *Premium Sound - Your Premium E-TAC is also the
quietest PTAC ever. Not only does it have 2 fan motors and a tangential blower wheel for optimum
sound, the indoor fan will always run a minimum of 10 seconds before the compressor, to help reduce any compressor starting noise. * Random Compressor restart = To help prevent power surges after a power outage (from many of your E=TACs starting at the same time), the compressor is equipped with a 2:45 to 3:15 random restart delay feature. Whenever the unit is plugged in, or power has been restarted, a random compressor
restart will occur. * Dry Mode - will help to manage and reduce the
humidity in the room, making it more comfortable. In DRY mode, the unit will modulate cooling mode at low fan speed until the room temperature is 4 deg. F
below the room temperature setting regardless of fan
mode selection. Dry mode should not be considered a
substitute for a stand alone dehumidifier.
* Compressor Protection = To prevent short cycling of the compressor and maximize it's life, there is a random start=up delay of 3 minutes on the compressor and a minimum compressor run time of 3
minutes. *Automatic room freeze protection - automatically
will keep the temperature in the room from getting
too cold, -where water pipes might freeze. If the unit
is configured for the freeze protection feature to be
active (which is the default condition), then-whenever
power is supplied to the unit, if the unit senses
temperature below 40°F (4.4°C), the fan motor and
electric heater are turned on and -will warm the room
to 50 ° F (10°C). If Freeze protection is not required,
change the configuration switch to turn the feature off
(see section on unit configuration). ° Automatic defrost protection (for heat pump
models only) - When the outdoor temperature gets too cold (approx. 40°F / 4.4°C) and the unit can no longer effectively heat with the compressor, the unit
will automatically switch to electric heating. The unit
will then heat with electric heat until the outside
temperature rises enough (approx. 40°F / 4.4°C), so
the compressor can be used again.
* Automatic Quick Warm-up (for heat pump
models only) = If the room temperature falls to 5°F
(2.8°C) below the set point temperature, the reverse cycle heat is shut off and the electric strip heat is
turned on for one cycle, until heating is satisfied. * LED Indicator's and Buttons = The touch pad has
buttons for MODE, FAN SPEED, ON/OFF,
SETPOINT UP and SETPOINT DOWN. It also has LEDs that correspond to the mode, fan speed and
setpoint operation, to indicate the unit's status. The LEDs below the mode button, FAN, COOL, and
HEAT, indicate what operating mode is active. The
LEDs below the Fan button, Low, Med and Hi, indicate the fan speed that is selected. The LED located in the lower right corner is the unit On/Off
status LED. if the unit is in ON mode, the LED will be green, if the unit is OFF, the LED will be red.
* Configure Fan to Optimize Selected Application -
Unit can be optimized to selected application by
configuring the fan to run in continuous mode or cycle
on and off with the compressor and electric heater (can be different for both heating and cooling modes). In
cycle mode, fan will continue to run 60 seconds after
compressor or electric heater stops in order blow off
any residual heat or cool left on coil.
UNIT FEATURES CONTINUED
* Unit Configuration = There are many different configuration possibilities, through both dipswitches
and the digital keypad, that allow you to configure the unit for your exact application. See section on unit configuration for more details. Following are the configuration selections that have not previously been
mentioned: * Fahrenheit °F or Celcious °C = The unit can display
in either °F or °C. * Indoor Temperature Sensor Biasing = Optimize
the room temperature sensor reading to your exact application (one for cooling and another for heating). * Emergency Heat (for Heat Pump Only) = Disable
the compressor during heating mode operation (heat only with Electric Heat).
* Display Setpoint or Room Temperature = The
unit can be configured to display the room temperature OR setpoint only, during heating and cooling modes. See section on unit configuration for
more details.
* Limit the Setpoint Range = The unit can be configured to limit the controlling setpoint range. The
display will always show the complete setpoint range, but the controlling setpoint will be limited to the
configured minimum and maximum setpoint selected.
See section on unit configuration for more details.
* Energy Management = Sometimes known as
Front Desk Control, an input is provided so that the
unit can be manually disabled from a different location. If the unit detects 24vac on this input, it will
automatically turn itself off. If no voltage is detected on the input, the unit will run normally.
* Wall Thermostat Control = A wired wall
thermostat can be connected to the unit. if it is, the
unit must be configured to disable the keypad. See
section on wired inputs and unit configuration for
more details.
ETAC
SeriesETACDesignation 1
Cooling Capacity 07 - 7,000 BTUH
09 - 9,000 BTUH
12 - 12,000 BTUH 15 - 15,000 BTUH
Model Type HP -Heat Pump
HC - Heat/Cool
12 HP 230V 20 A -A
Environmental Protection
A- Standard Protection
C - Sea Coast Protection
Revision Level
Electric Heat Capacity 15-2 KW
20 - 3 KW 30 - 5 KW
Electrical Rating
230V -208/230V 60Hz IPH 265V-265V 60Hz IPH
Fig. 3 = Catalog Number Nomenclature
ELECTRICAL DATA
ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal
injury or death and/or property damage DO NOT alter cord or plug or use an extension cord.
IMPORTANT: For 265V units, if power cord accessory option is selected, the cord is only 18 inches
long and must plug into the accessory electrical 265V subbase.
Be sure that your outlet matches the appropriate blade configuration of the plug and that it is within reach of
the service cord. All wiring, including installation of the receptacle,
must be in accordance with the NEC and local codes, ordinances and regulations. National codes require the use of an arc fault or leakage current detection device on all 208/230V power cords. Be sure to select the correct cord for your installation.
ALL UNITS
Wire Size
Use recommended wire size given in Table 1 and install a single branch circuit. All wiring must comply with local and national codes. All units are designed to operate offONE single branch circuits
only.
NOTE: Use copper conductors only.
Table 1--SUGGESTED BRANCH CIRCUIT WIRE SIZES*
Groundin_
For safety and protection, the unit is grounded through the service cord plug or through separate
ground wire provided on hard wired units. Be sure that the branch circuit or general purpose outlet is grounded.
VOLTAGE SUPPLY
Check voltage supply at outlet. For satisfactory results, the voltage range must always be within the ranges found on the data information plate.
Cord-connected Units
The 208/230-v field supplied outlet must match the plug for the standard 208/230-v units and be within reach of the service cord. The standard cord-connected
265-v units require an accessory electrical subbase for operation. Refer to Table 2 for proper receptacle
and fuse type. Power Cord Protection
The power cord for 208/230v units provide power cord fire protection. Unit power automatically
disconnects when unsafe conditions are detected. Power to the unit can be restored by pressing the reset
button on plug head. Upon completion of unit installation for 208/230V
models, an operational check should be performed using the TEST/RESET buttons on the plug head.
NOTE: The 265v models do not incorporate this
feature as they require use of the electrical subbase
accessory.
NAMEPLATE AMPS
7.0 to 12
12.1 to 16
16.1 to 24
LEGEND
AWG - American Wire Gauge * Single circuit from main box.
1-Based on copper wire at 60°C temperature rating.
RECEPTACLE
AMPS 15 20 30 15 20 30
RATED VOLTS 250 250 250 265 265 265
TIME- DELAY TYPE FUSE (or 15 20* 30 15 20 30
HACR Circuit Breaker)
LEGEND HACR - Heating, Air Conditioning, Refrigeration
* May be used for 15-amp applications if fused for 15 amps.
AWG WIRE SIZEt
14 12
10
Table 2--RECEPTACLES AND FUSE TYPES - 250,265 VOLTS
INSTALLATION
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not covered under the Warranty.
CHASSIS INSTALLATION Units are shipped without a sleeve. In applications
where unit is a replacement, it is recommended that a Gree sleeve be used.
These units can retrofit Carrier, General Electric, Amana, Trane, and Friedrich sleeves/grilles (be sure
outdoor grille is installed on the sleeve). See Table 3 for details. Gree engineering must approve any other
retrofit application. For competitive retrofit applications, be sure that the
foam seals (factory-installed on the tube sheets) provide a good seal between the grille and outdoor coil
tube sheets. These foam seals provide a barrier to separate outdoor coil leaving air from mixing with the outdoor incoming air (known as air recircula- tion).
UNIT DAMAGE AND/OR OPERATION HAZARD Failure to follow this caution may result in equipment
damage or improper operation. For retrofit applications, foam seals on outdoor coil tube
sheets must make a seal between the coil and the grille or loss of performance and premature damage to the maior components can result.
Table 3--Retrofit Wall Sleeves
Manufacturer Wall Sleeve Part Number
General Electric Metal Sleeve RAB71
Plastic Sleeve RAB77
Amana Metal Sleeve WS900D
Carrier Metal Sleeve - SLEEVE-STEEL-1PK
Plastic Sleeve - WALL-SLEEVE-1PK
Trane Metal Sleeve SLV149
Friedrich T-Series Metal 11-1/2" (292.1 mm)
Deep Wall Sleeve* Standard Depth Wall Sleeve
16 X 42 X 133/4-in. (406.4 X 1067 X
349.3 mm) PXWS
FR-SLEEVE-EXT accessory is required for retrofit into Friedrich
(T-Series) wall sleeves.
Minimum wall sleeve opening must be greater than
14.75 X 40.00 in. (374.7 x 1016 mm)
INLET FILTERS
FRONT
PANEL
WIRE SCREEN
DISCHARGE
GRILLE
\
OUTDOOR ORIFICE
COIL TUBE SHEETS
INDOOR COIL
Fig. 4 - Unit Components
ACCESSOR
OUTDOOR
GRILLE
ACCESSORY
WALL
SLEEVE
BASEPAN
RETROFIT SLEEVE PREPARATION
IMPORTANT: Inspect wall sleeve thoroughly prior to installation. Manufacturer does not assume responsibility for costs or damages due to defects in sleeve or for improper installation.
ELECTRICAL SHOCK HAZARD
Failnre to %llow this warning conld resnlt in personal injury or death.
Disconnect all power to unit to avoid possible electrical shock during installation.
GE Plastic Sleeve = Remove bottom seal from plastic sleeve. See Fig. 6.
INSTALLATION OF A GREE WALL SLEEVE USING A NON-GREE GRILLE
This application has become more common due to pre-manufactured windows with built-in grilles or
renovations where a Gree sleeve is used with an existing non-Gree grille.
BOTTOM SEAL
Fig. 6 = Remove Bottom Seal From GE Plastic Sleeve
Use of a Gree wall sleeve with a non-Gree grille requires installation of an Accessory Baffle Kit (see
Fig. 7), which ensures a good seal between the unit and exterior grille to prevent air recirculation. Air recirculation is a large contributor to performance loss and premature damage to major components.
CONDENSATE REMOVAL SYSTEM
Gree's series has a new condensate (water) disposal system. The outdoor fan prop has a built in slinger
ring which draws condensate water and sprays it on the warm outdoor coil for evaporation. Thus providing
better disposal of excess condensate and improving unit operating efficiency.
It is normal and desirable to have some condensate water in the base pan to boost operating efficiency.
All heat pump units contain a condensate drain valve. This temperature activated drain valve opens
when the outdoor temperature drops below 55 ° F (12.8 ° C) to prevent water from freezing in the base
pan. The water drains from the unit though the wall sleeve and out the wall sleeve's rear condensate
drainage holes. If the condensate drain kit accessory is attached to the wall sleeve, water will drain
through the condensate drain tube.
Fig. 7 = Accessory Baffle Kit
SLINGER RING
Condensate Removal System
CONDENSER SECTION
A(17678
NOTE: This unit will not always evaporate 1{)0% of the unit generated condensate and blown in
rain water, If it is necessary to control 1!)0% of the condensate, the Drain Kit (Part No,: DRAIN-
and a building condensate drain
system is recommended,