Gree ETAC12HP230V30AA User Manual

E-TAC (GB Series) Packaged Terminal Air Conditioner / Heat Pump 7,000 --- 15,000 Btuh
Performance and Specifications
Engineered Terminal Air Conditioner
APPLICATIONS
Hotels and motels
Nursing homes and assisted living care
centers
Offices
Apartments
Single--family dwellings
Home conversions and residential add--ons
NEW CONSTRUCTION
ADVANTAGES FOR NEW CONSTRUCTION
Design Flexibility for the Architect/Engineer
Whisper--quiet performance, indoors and out
No bulky duct system
No separate equipment room
No water towers or additional cooling
equipment
No complex match--up of different HVAC components
Less sensitivity to building orientation (sun, wind, shade)
Optional architectural grille to permit custom exterior appearance
Initial Cost Savings for the Bu ildin
g Owner
No e
xpensive component HVAC system
purchase
No equipment room or maintenance engineering staff
Two--part delivery to minimize on--site damage
Weather--protected wall sleeve that goes in place during construction; chassis that slides in place after construction
No seasonal changeover required for cooling or heating -- units are self--contained comfort systems
Lower Operating Costs and Reliable Comfort for The Occupant
Heat pump models offer substantial savings over models with conventional electric resistance heaters
Individual units allow tenants to choose the degree of comfort and operating economy.
Rapid servi
cing reduces downtime: complete chassis can be replaced in minutes without disrupting other occupants.
Each unit operates independently of other units in the building. No dependency by building on central HVAC system.
RETROFIT/REPLACEMENT
If you are replacing a unit in an existing wall sleeve, your options include:
Replace the existing wall sleeve with the the polymer wall sleeve. See accessory sleeve section for selecting the correct sleeve for your application. NOTE: in most cases, when replacing the wall sleeve, the exterior grille must also be replaced.
Use an existing sleeve and exterior grille. The Gree E-TAC will fit into:
Friedrich T series and ZoneAire wall
sleeves, with a required wall sleeve extension (see access
ory Friedrich
Retrofit Wall Sleeve Adapter).
Whether you are designing a new structure or replacing packaged terminal air conditioning units in an existing building, Gree E-TAC will meet your needs.
The Gree E-TAC Packaged Terminal Air Conditioning (E-TAC) unit is designed to meet the needs of the architect, engineer, and contractor. For unit installation, Gree’s expert support network will assist in all applicable aspects of the construction project, from preparing a budget to start-up.
4
The following major competitors’ wall sleeves/grilles: Carrier, GE, Amana, Trane, Friedrich and Bryant, and NO accessory retrofit kit is required.
TABLE OF CONTENTS
APPLICATIONS 3-4.................................
PRODUCT NOMENCLATURE 4.......................
PRODUCT OVERVIEW 5.............................
PRODUCT FEATURES & BENEFITS 6-9.............. .
COASTAL PROTECTION 10.............. . .... . . . . . . .
HEAT PUMP OPERATION
FIELD INSTALLED ACCESSORIES 12-20.............. .
DIMENSIONAL DRAWINGS & INSTALLATION DATA -- NEW CONSTRUCTION 21-25. . .
WALL THERMOSTAT CONNECTIONS 26..............
E-TAC
11.............. . .... . .... .
PERFORMANCE AND ELECTRICAL DATA 27-30...... .
EXPANDED OPERATING RATING 31-33...............
INDOOR FAN PERFORANCE DATA 33.................
SOUND DATA 34-35.................................
SOUND TRANSMISSION COEFFICIENT 35. . ...........
OUTDOOR GRILLE SIZING & VENT AIRFLOW. . . . . . 37
TYPICAL WIRING SCHEMATICS ............ 38
ENERGY MANAGEMENT WIRING 39............... . .
MULTIPLE WALL THERMOSTAT WIRING 40....... . . .
GUIDE SPECIFICATION 41-44........................
. ...
2
APPLICATIONS
APPLICATIONS
Hotels and motels
Nursing homes and assisted living care
centers
Offices
Apartments
Single--family dwellings
Home conversions and residential add--ons
NEW CONSTRUCTION
ADVANTAGES FOR NEW CONSTRUCTION
Design Flexibility for the Architect/Engineer
Whisper--quiet performance, indoors and out
No bulky duct system
No separate equipment room
No water towers or additional cooling
equipment
No complex match--up of different HVAC components
Less sensitivity to building orientation (sun, wind, shade)
Optional architectural grille to permit custom exterior appearance
Initial Cost Savings for the Buildin
g Owner
No expensive component HVAC system purchase
No equipment room or maintenance engineering staff
Two--part delivery to minimize on--site damage
Weather--protected wall sleeve that goes in place during construction; chassis that slides in place after construction
No seasonal changeover required for cooling or heating -- units are self--contained comfort systems
Lower Operating Costs and Reliable Comfort for The Occupant
Heat pump models offer substantial savings over models with conventional electric resistance heaters
Individual units allow tenants to choose the degree of comfort and operating economy.
R
apid servicing reduces downtime: complete chassis can be replaced in minutes without disrupting other occupants.
Each unit operates independently of other units in the building. No dependency by building on central HVAC system.
RETROFIT/REPLACEMENT
If you are replacing a unit in an existing wall sleeve, your options include:
Replace the existing wall sleeve with the the polymer wall sleeve. See accessory sleeve section for selecting the correct sleeve for your application. NOTE: in most cases, when replacing the wall sleeve, the exterior grille must also be replaced.
Use an existing sleeve and exterior grille. The Gree E-TAC will fit into:
Friedrich T series and ZoneAire wall
sleeves, with a required wall sleeve extension (see accessory Friedrich Retrofit Wall Sleeve Adapter).
Whether you are designing a new structure or replacing packaged terminal air conditioning units in an existing building, Gree E-TAC will meet your needs.
The Gree E-TAC Packaged Terminal Air Conditioning (E-TAC) unit is designed to meet the needs of the architect, engineer, and contractor. For unit installation, Gree’s expert support network will assist in all applicable aspects of the construction project, from preparing a budget to start-up.
4
The following major competitors’ wall sleeves/grilles: Carrier, GE, Amana, Trane, Friedrich and Bryant, and NO accessory retrofit kit is required.
Whether you are designing a new structure or replacing packaged terminal air conditioning units in an existing building, Gree E-TAC will meet your needs.
Hotels and motels
Nursing homes and assisted living care
centers
Offices
Apartments
Single--family dwellings
Home conversions and residential add--ons
NEW CONSTRUCTION
The Gree E-TAC Packaged Terminal Air Conditioning
E-TAC
(E-TAC) unit is designed to meet the needs of the architect, engineer, and contractor. For unit installation, Gree’s expert support network will assist in all applicable aspects of the construction project, from preparing a budget to start-up.
ADVANTAGES FOR NEW CONSTRUCTION
Design Flexibility for the Architect/Engineer
Whisper--quiet performance, indoors and out
No bulky duct system
No separate equipment room
No water towers or additional cooling
equipment
No complex match--up of different HVAC components
Less sensitivity to building orientation (sun, wind, shade)
Optional architectural grille to permit custom exterior appearance
Lower Operating Costs and Reliable Comfort for The Occupant
Heat pump models offer substantial savings over models with conventional electric resistance heaters
Individual units allow tenants to choose the degree of comfort and operating economy.
apid servicing reduces downtime: complete
R chassis can be replaced in minutes without disrupting other occupants.
Each unit operates independently of other units in the building. No dependency by building on central HVAC system.
RETROFIT/REPLACEMENT
If you are replacing a unit in an existing wall sleeve, your options include:
Replace the existing wall sleeve with the the polymer wall sleeve. See accessory sleeve section for selecting the correct sleeve for your application. NOTE: in most cases, when replacing the wall sleeve, the exterior grille must also be replaced.
Use an existing sleeve and exterior grille. The Gree E-TAC will fit into:
The following major competitors’ wall
sleeves/grilles: Carrier, GE, Amana, Trane, Friedrich and Bryant, and NO accessory retrofit kit is required.
— Friedrich T series and ZoneAire wall
sleeves, with a required wall sleeve extension (see accessory Friedrich Retrofit Wall Sleeve Adapter).
E-TAC
g Owner
Initial Cost Savings for the Buildin
No expensive component HVAC system purchase
No equipment room or maintenance engineering staff
Two--part delivery to minimize on--site damage
Weather--protected wall sleeve that goes in place during construction; chassis that slides in place after construction
No seasonal changeover required for cooling or heating -- units are self--contained comfort systems
3
PRODUCT CATALOG NUMBER-NOMENCLATURE
APPLICATIONS
Hotels and motels
Nursing homes and assisted living care
centers
Offices
Apartments
Single--family dwellings
Home conversions and residential add--ons
NEW CONSTRUCTION
ADVANTAGES FOR NEW CONSTRUCTION
Design Flexibility for the Architect/Engineer
Whisper--quiet performance, indoors and out
No bulky duct system
No separate equipment room
No water towers or additional cooling
equipment
No complex match--up of different HVAC components
Less sensitivity to building orientation (sun, wind, shade)
Optional architectural grille to permit custom exterior appearance
Initial Cost Savings for the Buildin
g Owner
N
o expensive component HVAC system
purchase
No equipment room or maintenance engineering staff
Two--part delivery to minimize on--site damage
Weather--protected wall sleeve that goes in place during construction; chassis that slides in place after construction
No seasonal changeover required for cooling or heating -- units are self--contained comfort systems
Lower Operating Costs and Reliable Comfort for The Occupant
Heat pump models offer substantial savings over models with conventional electric resistance heaters
Individual units allow tenants to choose the degree of comfort and operating economy.
Rapi
d servicing reduces downtime: complete chassis can be replaced in minutes without disrupting other occupants.
Each unit operates independently of other units in the building. No dependency by building on central HVAC system.
RETROFIT/REPLACEMENT
If you are replacing a unit in an existing wall sleeve, your options include:
Replace the existing wall sleeve with the the polymer wall sleeve. See accessory sleeve section for selecting the correct sleeve for your application. NOTE: in most cases, when replacing the wall sleeve, the exterior grille must also be replaced.
Use an existing sleeve and exterior grille. The Gree E-TAC will fit into:
Friedrich T series and ZoneAire wall
sleeves, with a required wall sleeve ex
tension (see accessory Friedrich
Retrofit Wall Sleeve Adapter).
Whether you are designing a new structure or replacing packaged terminal air conditioning units in an existing building, Gree E-TAC will meet your needs.
The Gree E-TAC Packaged Terminal Air Conditioning (E-TAC) unit is designed to meet the needs of the architect, engineer, and contractor. For unit installation, Gree’s expert support network will assist in all applicable aspects of the construction project, from preparing a budget to start-up.
4
The following major competitors’ wall sleeves/grilles: Carrier, GE, Amana, Trane, Friedrich and Bryant, and NO accessory retrofit kit is required.
Cooling Capacity 07 - 7,000 BTUH Electric Heat Capacity
ETAC
12 HP 230V 20 -AA
E-TAC
Fig. 3 – Catalog Number Nomenclature
APPLICATION CONSIDERATIONS
Installation instructions are shipped with all E-TAC units. It is important that air conditioning systems be properly sized and installed for each application in order to achieve the desired temperature and humidity levels within the space to be conditioned. It is strongly recommended that a professional engineer match the E-TAC units with the building structure and climate.
The following application considerations are all important in choosing the proper E-TAC for the building structure.
Undersizing
If an E-TAC unit is undersized (cooling capacity is less than required load for an application), the unit will not be able to cool the space down to the desired temperature during very hot days. The result could be warm and humid or warm and dry conditioned space.
Oversizing
If an E-TAC unit is oversized (cooling capacity is greater than required load for the specific application), the unit will cool the space down to the desired temperature too
The unit will cycle on and off, however, dehumidification only takes place when the unit is operating. The result of this type of application in a hot and/or humid climate would beacool, yet excessively humid, space.
quickly.
Air Infiltration
Excessive air infiltration can intensify problems associated with undersizing or oversizing a E-TAC unit. This can be the cause of insufficient cooling, dehumidification, or heating. Sources of air infiltration include vents, gaps around windows and doors, and improperly sealed floors, ceilings or wall joints.
Condensate Removal
Gree’s E-TAC has a new condensate (water) disposal system. The outdoor fan prop has a built in slinger ring which draws condensate and sprays it on the warm outdoor coil for evaporation. Thus providing better disposal of excess condensate and improving unit operating efficiency.
It is normal and desirable to have some condensate water in the base pan to boost operating efficiency.
NOTE: This unit will not always evaporate 100% of the unit generated condensate and blown in rain water. If it is necessary to control 100% of the condensate, the Drain Kit (Part No.: DRAIN­KIT-1PK) and a building condensate drain system is recommended.
noitcetorPlatnemnorivnEnoitangiseDseireS
noitcetorPdradnatS-ACATE
C - Sea Coast Protection
Revision Level
WK2-51HUTB000,9-90 WK3-02HUTB000,21-21 WK5-03HUTB000,51-51
gnitaRlacirtcelEepyTledoM
HP1zH06V032/802-V032pmuPtaeH-PH
HP1zH06V562-V562looC/taeH-CH
4
PRODUCT OVERVIEW (E-TAC)
APPLICATIONS
Hotels and motels
Nursing homes and assisted living care
centers
Offices
Apartments
Single--family dwellings
Home conversions and residential add--ons
NEW CONSTRUCTION
ADVANTAGES FOR NEW CONSTRUCTION
Design Flexibility for the Architect/Engineer
Whisper--quiet performance, indoors and out
No bulky duct system
No separate equipment room
No water towers or additional cooling
equipment
No complex match--up of different HVAC components
Less sensitivity to building orientation (sun, wind, shade)
Optional architectural grille to permit custom exterior appearance
Initial Cost Savings for the Buildin
g Owner
No
expensive component HVAC system
purchase
No equipment room or maintenance engineering staff
Two--part delivery to minimize on--site damage
Weather--protected wall sleeve that goes in place during construction; chassis that slides in place after construction
No seasonal changeover required for cooling or heating -- units are self--contained comfort systems
Lower Operating Costs and Reliable Comfort for The Occupant
Heat pump models offer substantial savings over models with conventional electric resistance heaters
Individual units allow tenants to choose the degree of comfort and operating economy.
Rapid
servicing reduces downtime: complete chassis can be replaced in minutes without disrupting other occupants.
Each unit operates independently of other units in the building. No dependency by building on central HVAC system.
RETROFIT/REPLACEMENT
If you are replacing a unit in an existing wall sleeve, your options include:
Replace the existing wall sleeve with the the polymer wall sleeve. See accessory sleeve section for selecting the correct sleeve for your application. NOTE: in most cases, when replacing the wall sleeve, the exterior grille must also be replaced.
Use an existing sleeve and exterior grille. The Gree E-TAC will fit into:
Friedrich T series and ZoneAire wall
sleeves, with a required wall sleeve extension (see acce
ssory Friedrich
Retrofit Wall Sleeve Adapter).
Whether you are designing a new structure or replacing packaged terminal air conditioning units in an existing building, Gree E-TAC will meet your needs.
The Gree E-TAC Packaged Terminal Air Conditioning (E-TAC) unit is designed to meet the needs of the architect, engineer, and contractor. For unit installation, Gree’s expert support network will assist in all applicable aspects of the construction project, from preparing a budget to start-up.
4
The following major competitors’ wall sleeves/grilles: Carrier, GE, Amana, Trane, Friedrich and Bryant, and NO accessory retrofit kit is required.
This section summarizes product features covered in detail in later sections of this manual.
COIL TUBE SHEETS
OUTDOOR ORIFICE
WIRE SCREEN
DISCHARGE GRILLE
INDOOR-AIR INLET FILTERS
Comfortouch Digital Control
• Temperature Display and Touch Pad on Unit
Precise and easy-to-use
• Continuous Temperature Sensing
• Cooling, Heating and Fan Modes
• Setpoint Stoppers
• Auto Restart and Random Restart Delay
• Freeze Protection
Protects unoccupied rooms from freezing
• Emergency Heat (Heat Pump Models)
• Remote Control Options
FRONT PANEL
Unit Components
Ideal comfort for your guests
One unit for all seasons
Electronic temperature limiting reduces operating costs
Automatically restarts after a power failure
temperatures
Bypasses compressor operation and activates electric heater for guest comfort
The ultimate in installation exibility; Wired, WirelessorEnergyManagement
ACCESSOR
INDOOR
COIL
BASEPAN
ACCESSORY
WALL
SLEEVE
Silencer System
• Three-Speed Indoor Fan
 Morecomfortoptionsforgueststochoosefrom
• Dual Motor Technology
Separate indoor and outdoor motors allows one of the
• AeroQuiet Indoor Blower Wheel
quietestandmostefcientunitsintheindustry
 Providesquiet andconsistent airow formaximum
guest comfort
• Rotary Compressor Technology
Quiet operation and low sound transmission indoors
•Insulated Bulkhead Between Indoors and Outdoors
Quiet operation and low sound transmission indoors
Smartfan Comfort Control
Programmable Constant Fan Operation
Gree customized comfort in heating or cooling modes.
• Quiet Fan Start-Up and Stops
Smooth ramp-up and ramp-down of fan speed for quiet comfort
OUTDOOR
GRILLE
E-TAC
E-TAC
5
E-TAC PRODUCT FEATURES AND BENEFITS
APPLICATIONS
Hotels and motels
Nursing homes and assisted living care
centers
Offices
Apartments
Single--family dwellings
Home conversions and residential add--ons
NEW CONSTRUCTION
ADVANTAGES FOR NEW CONSTRUCTION
Design Flexibility for the Architect/Engineer
Whisper--quiet performance, indoors and out
No bulky duct system
No separate equipment room
No water towers or additional cooling
equipment
No complex match--up of different HVAC components
Less sensitivity to building orientation (sun, wind, shade)
Optional architectural grille to permit custom exterior appearance
Initial Cost Savings for the Buildin
g Owner
No e
xpensive component HVAC system
purchase
No equipment room or maintenance engineering staff
Two--part delivery to minimize on--site damage
Weather--protected wall sleeve that goes in place during construction; chassis that slides in place after construction
No seasonal changeover required for cooling or heating -- units are self--contained comfort systems
Lower Operating Costs and Reliable Comfort for The Occupant
Heat pump models offer substantial savings over models with conventional electric resistance heaters
Individual units allow tenants to choose the degree of comfort and operating economy.
Rapid servi
cing reduces downtime: complete chassis can be replaced in minutes without disrupting other occupants.
Each unit operates independently of other units in the building. No dependency by building on central HVAC system.
RETROFIT/REPLACEMENT
If you are replacing a unit in an existing wall sleeve, your options include:
Replace the existing wall sleeve with the the polymer wall sleeve. See accessory sleeve section for selecting the correct sleeve for your application. NOTE: in most cases, when replacing the wall sleeve, the exterior grille must also be replaced.
Use an existing sleeve and exterior grille. The Gree E-TAC will fit into:
Friedrich T series and ZoneAire wall
sleeves, with a required wall sleeve extension (see access
ory Friedrich
Retrofit Wall Sleeve Adapter).
Whether you are designing a new structure or replacing packaged terminal air conditioning units in an existing building, Gree E-TAC will meet your needs.
The Gree E-TAC Packaged Terminal Air Conditioning (E-TAC) unit is designed to meet the needs of the architect, engineer, and contractor. For unit installation, Gree’s expert support network will assist in all applicable aspects of the construction project, from preparing a budget to start-up.
4
The following major competitors’ wall sleeves/grilles: Carrier, GE, Amana, Trane, Friedrich and Bryant, and NO accessory retrofit kit is required.
E-TAC 5-YEAR WARRANTY
All E-TACs are protected by a ve-year limited warranty.
•Two-yearpartsandlaborlimitedwarranty
• Three years additional parts andlabor coverage on
the sealed refrigeration system
• Limitedthreeyears(years3-5)parts-onlycoverage
TWO--PIECE LIFETIME INDOOR FILTER
E-TAC
Two--piece removable filters easily slide in and out from the front of the E-TAC unit and are interchangeable. The front panel does not need to be removed to access or change the filters. The filters are washable and permanent.
EASY ACCESS TO CHASSIS
Access to the chassis simply requires removing front panel, then four easy to access screws and then sliding the chassis out of the sleeve for service or maintenance.
E-TAC GB Series
Packaged Terminal Air Conditioner Limited Warranty
TWO-YEAR PARTS AND LABOR LIMITED WARRANTY – During the fi rst two years after purchase, GREE will, through its authorized independent servicing dealer or service stations*, and free of charge to the user or subsequent users, repair or replace any parts that fail due to defect in material or wor kmanship. The replacement part can be a new or remanufactured part as provided at GREE’S sole option.
EXTENDED THREE-YEAR PARTS AND LABOR LIMITED WARRANTY ON SEALED REFRIGERATION SYSTEM ONLY – During the third through fi fth years after date
of original purchase, GREE will, through its author ized servicing dealers and service stations* and free of charge to the end user or subsequent users, repair or replace the compressor, condenser, evaporator or connecting tubing if it failed due to defect in material or workmanship. This includes system refrigeration charge. The replacement part can be new or a remanufactured part at GREE’S sole option.
EXTENDED THREE-YEAR PARTS ONLY LIMITED WARRANTY ON NON-SEALED REFRIGERATION SYSTEM ONLY – During the third through fi fth years after date of original
purchase, Gree will, through its authorized servicing dealers and service stations and free of charge to the end user or subsequent users, repair or replace any non-sealed system part (motor, solenoid, thermistor, circuit boards, relays, switch, capacitor, overload, drain valve, fan, stator) if failed due to defect in material or workmanship. The replacement part can be new or a remanufactured part at GREE’S sole option. THIS LIMITED WARRANTY DOES NOT INCLUDE LABOR, user is responsible for labor, including cost of diagnosis of problem, removal and transportation of the air conditioner to and from the service center, and reinstallation charges necessary to accomplish repair.
LIMITATION OF WARRANTIES – ALL IMPLIED WARRANTIES (INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR USE OR PURPOSE) ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH EACH LIMITED WARRANTY IS GIVEN AND APPLIES. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. THE EXPRESSED WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED, ENLARGED CHANGED BY ANY DISTRIBUTOR, DEALER, OR OTHER PERSON WHATSOEVER.
ALL WORK UNDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING HOURS. ALL REPLACEMENT PA RTS, WHETHER NEW OR REMANUFACTURED, ASSUME AS THEIR WARRANTY PERIOD ONLY THE REMAINING TIME PERIOD OF THIS WARRANTY.
*Authorized independent dealers or service stations are registered with Gree through its distributor organization.
This warranty gives you specifi c legal rights, and you may also have other rights which vary from state to state.
GREE WILL NOT BE RESPONSIBLE FOR:
1. CLEANING REQUIRED PRIOR TO WARRANTY REPAIR.
2. Standard maintenance, cleaning or damage resulting from failure to perfo rm normal maintenance as outlined in the owner’s manual.
3. Instruction on methods of control and use of air conditioning unit after initial installation.
4. Damage or repairs needed as consequence of faulty installation or application. This is the responsibility of the installer.
5. Failure to start due to voltage conditions, blown fuses, open circuit breakers or any other damages due to the inadequacy or interruption of electrical services.
6. Damage or repairs needed as consequence of any misapplication, abuse, unauthorized alteration, improper servicing or operation.
7. Damage as a result of fl oods, winds, fi res, lightning, accidents, corrosive environment, or other conditions beyond the control of GREE. EXCEPTION TO CORROSIVE ENVIRONMENT EXCLUSION IN ABOVE PARAGRAPH – Packed terminal units (GB Series) built with corrosion protection are exempt from the exclusion – “Corrosive Environment.” The unit model number is identified on the nameplate with CP suffix.
8. Reimbursement for replacement parts or repair services which are not supplied or designated by GREE and which are specifi cally covered under this warranty.
9. GREE products installed outside the continental U.S.A., Alaska, Hawaii, and Canada.
10. Shipping damage or damage as a result of transporting the unit. This is the responsibility of the selling dealer or the authorized service station.
11. ANY SPECIAL, INDIRECT OR CONSEQUENTIAL PROPERTY OR COMMERCIAL DAMAGE OF ANY NATURE WHATSOEVER. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
12. Warranty coverage of accessor
13. Installations of non-corrosion protected models within one (1) mile of a corrosive body of water or environment shall void the EXTENDED THREE-YEAR PA RTS AND LABOR LIMITED WARRANTY ON SEALED REFRIGERATION SYSTEM ONLY and EXTENDED THREE-YEAR PA RTS ONLY LIMITED WARRANTY ON
, OR
NON-SEALED REFRIGERATION SYSTEM ONLY limited warranties .
Edition Date: 11-11
y items (wall thermostats, wall sleeves
, etc.)
Exclusive Warranty
2 Air filters
Two --Piece Indoor Filter
A07057
Easy to Access Chassis
GA
OUTDOOR AIR VENTILATION
The unique vent system is activated by a two­position control. Fresh outside air is redirected by the vent door to the indoor room. A molded plastic filter prevents dirt and debris from entering the room side of the unit. The vent mechanism is made from non corrosive material ensuring reliable operation. A magnet
high-pressure airflow create a tight, draft free seal
when the vent door is closed.
or screw on the door and
The vent will provide fresh air. For vent airflow data see page 37.
A07550
Outdoor Air Ventilation
6
BI--DIRECTIONAL DISCHARGE
)
APPLICATIONS
Hotels and motels
Nursing homes and assisted living care
centers
Offices
Apartments
Single--family dwellings
Home conversions and residential add--ons
NEW CONSTRUCTION
ADVANTAGES FOR NEW CONSTRUCTION
Design Flexibility for the Architect/Engineer
Whisper--quiet performance, indoors and out
No bulky duct system
No separate equipment room
No water towers or additional cooling
equipment
No complex match--up of different HVAC components
Less sensitivity to building orientation (sun, wind, shade)
Optional architectural grille to permit custom exterior appearance
Initial Cost Savings for the Buildin
g Owner
No expensive component HVAC system purchase
No equipment room or maintenance engineering staff
Two--part delivery to minimize on--site damage
Weather--protected wall sleeve that goes in place during construction; chassis that slides in place after construction
No seasonal changeover required for cooling or heating -- units are self--contained comfort systems
Lower Operating Costs and Reliable Comfort for The Occupant
Heat pump models offer substantial savings over models with conventional electric resistance heaters
Individual units allow tenants to choose the degree of comfort and operating economy.
R
apid servicing reduces downtime: complete chassis can be replaced in minutes without disrupting other occupants.
Each unit operates independently of other units in the building. No dependency by building on central HVAC system.
RETROFIT/REPLACEMENT
If you are replacing a unit in an existing wall sleeve, your options include:
Replace the existing wall sleeve with the the polymer wall sleeve. See accessory sleeve section for selecting the correct sleeve for your application. NOTE: in most cases, when replacing the wall sleeve, the exterior grille must also be replaced.
Use an existing sleeve and exterior grille. The Gree E-TAC will fit into:
Friedrich T series and ZoneAire wall
sleeves, with a required wall sleeve extension (see accessory Friedrich Retrofit Wall Sleeve Adapter).
Whether you are designing a new structure or replacing packaged terminal air conditioning units in an existing building, Gree E-TAC will meet your needs.
The Gree E-TAC Packaged Terminal Air Conditioning (E-TAC) unit is designed to meet the needs of the architect, engineer, and contractor. For unit installation, Gree’s expert support network will assist in all applicable aspects of the construction project, from preparing a budget to start-up.
4
The following major competitors’ wall sleeves/grilles: Carrier, GE, Amana, Trane, Friedrich and Bryant, and NO accessory retrofit kit is required.
GRILLE
The discharge grille is constructed of durable polycarbonate and is reversible. Airflows upward at a 40 degree angle to the floor but can easily be adjusted to an 80 degree angle to the floor.
SYSTEM CONFIGURATION
There are many different configuration possibilities, through both dip switches and the digital keypad, that allow you to configure the E-TAC for your exact application. See Owner’s Manual for more detailed information.
COMFORTOUCH DIGITAL CONTROL
The digital keypad provides a simple to operate control. The large, easy to press, “On/Off”, “Fan Speed”, “Mode”, “Setpoint Up” and “Setpoint Down” buttons make the control easy to operate. LEDs are used to show the operating conditions selected. Large numbers are used to display the Setpoint, and if configured, room air temperature.
STAY DRY DEHUMIDIFICATION
The E-TAC provide users with Stay Dry mode to reduce the humidity in the room, making it more comfortable.
The Stay Dry mode is designed to assist removing extra moisture from the air, not dry it out completely. This is not intended to replace a dehumidifier or act as a dehumidifier.
SLEEP MODE
The E-TAC sleep mode function is geared toward making sleeping conditions more pleasant without your having to get up and adjust the unit while in bed. The sleep mode feature allows a time period between 0.5 to 24 hours for the E-TAC to automatically turn off for a pleasant sleeping experience.
Air discharge outward (Default)
Air discharge upward
Bi-Directional Discharge Grille
Dipswitch
UP
Down
Configuration Switches
TEMP CONTROL
Comfortouch Display
Stay Dry Mode
Freeze guard Setpoint Limit 2 Setpoint Limit 1 Fan CON/CYC for cooling Fan CON/CYC for heating Wall Thermostat enable
Electric heat only (for Heat Pumps
DRY
FAN, MODE& OPERATION
A07072
E-TAC
Sleep Mode
7
SETPOINT STOPPER
APPLICATIONS
Hotels and motels
Nursing homes and assisted living care
centers
Offices
Apartments
Single--family dwellings
Home conversions and residential add--ons
NEW CONSTRUCTION
ADVANTAGES FOR NEW CONSTRUCTION
Design Flexibility for the Architect/Engineer
Whisper--quiet performance, indoors and out
No bulky duct system
No separate equipment room
No water towers or additional cooling
equipment
No complex match--up of different HVAC components
Less sensitivity to building orientation (sun, wind, shade)
Optional architectural grille to permit custom exterior appearance
Initial Cost Savings for the Buildin
g Owner
No expe
nsive component HVAC system
purchase
No equipment room or maintenance engineering staff
Two--part delivery to minimize on--site damage
Weather--protected wall sleeve that goes in place during construction; chassis that slides in place after construction
No seasonal changeover required for cooling or heating -- units are self--contained comfort systems
Lower Operating Costs and Reliable Comfort for The Occupant
Heat pump models offer substantial savings over models with conventional electric resistance heaters
Individual units allow tenants to choose the degree of comfort and operating economy.
Rapid servic
ing reduces downtime: complete chassis can be replaced in minutes without disrupting other occupants.
Each unit operates independently of other units in the building. No dependency by building on central HVAC system.
RETROFIT/REPLACEMENT
If you are replacing a unit in an existing wall sleeve, your options include:
Replace the existing wall sleeve with the the polymer wall sleeve. See accessory sleeve section for selecting the correct sleeve for your application. NOTE: in most cases, when replacing the wall sleeve, the exterior grille must also be replaced.
Use an existing sleeve and exterior grille. The Gree E-TAC will fit into:
Friedrich T series and ZoneAire wall
sleeves, with a required wall sleeve extension (see accessor
y Friedrich
Retrofit Wall Sleeve Adapter).
Whether you are designing a new structure or replacing packaged terminal air conditioning units in an existing building, Gree E-TAC will meet your needs.
The Gree E-TAC Packaged Terminal Air Conditioning (E-TAC) unit is designed to meet the needs of the architect, engineer, and contractor. For unit installation, Gree’s expert support network will assist in all applicable aspects of the construction project, from preparing a budget to start-up.
4
The following major competitors’ wall sleeves/grilles: Carrier, GE, Amana, Trane, Friedrich and Bryant, and NO accessory retrofit kit is required.
The E-TAC allows property owners to set setpoint
for heating and cooling. The ETAC comes from the factory with the economical range of 65 to 78˚
The cooling and heating setpoint ranges can be adjusted independently and the range may
be expanded or reduced to satisfy your needs and application. .
WALL THERMOSTAT INTERFACE
E-TAC provides a standard wired wall thermostat interface connecting block for quick easy installation. The unit has a removable terminal connector to make
E-TAC
field wiring easy. See more info on wall thermostat connections in the Dimensional Drawings and Instal­lation Data Section.
ENERGY MANAGEMENT INTERFACE
The Energy Management interface is standard and provides a simple to install Energy Management connection. The unit has a removable terminal connector to make field wiring easy. When 24VAC is supplied to the input the unit will turn off. Once the 24VAC is removed (becomes 0 volts), the unit will turn back on.
Note: For more info, see the section in the back, Typical Wiring Schematic For Energy Management Interface.
65 F 78 F
Electronic Setpoint Limiting
R W Y O Gh Gl C
Removable Thermostat Connector
A07634
Energy Management
Terminal Connections
Wall Thermostat
Terminal Connections
Wall Thermostat and Energy Managem ent
Interface
A07073
8
LCDI
APPLICATIONS
Hotels and motels
Nursing homes and assisted living care
centers
Offices
Apartments
Single--family dwellings
Home conversions and residential add--ons
NEW CONSTRUCTION
ADVANTAGES FOR NEW CONSTRUCTION
Design Flexibility for the Architect/Engineer
Whisper--quiet performance, indoors and out
No bulky duct system
No separate equipment room
No water towers or additional cooling
equipment
No complex match--up of different HVAC components
Less sensitivity to building orientation (sun, wind, shade)
Optional architectural grille to permit custom exterior appearance
Initial Cost Savings for the Buildin
g Owner
No
expensive component HVAC system
purchase
No equipment room or maintenance engineering staff
Two--part delivery to minimize on--site damage
Weather--protected wall sleeve that goes in place during construction; chassis that slides in place after construction
No seasonal changeover required for cooling or heating -- units are self--contained comfort systems
Lower Operating Costs and Reliable Comfort for The Occupant
Heat pump models offer substantial savings over models with conventional electric resistance heaters
Individual units allow tenants to choose the degree of comfort and operating economy.
Rapid
servicing reduces downtime: complete chassis can be replaced in minutes without disrupting other occupants.
Each unit operates independently of other units in the building. No dependency by building on central HVAC system.
RETROFIT/REPLACEMENT
If you are replacing a unit in an existing wall sleeve, your options include:
Replace the existing wall sleeve with the the polymer wall sleeve. See accessory sleeve section for selecting the correct sleeve for your application. NOTE: in most cases, when replacing the wall sleeve, the exterior grille must also be replaced.
Use an existing sleeve and exterior grille. The Gree E-TAC will fit into:
Friedrich T series and ZoneAire wall
sleeves, with a required wall sleeve extension (see acce
ssory Friedrich
Retrofit Wall Sleeve Adapter).
Whether you are designing a new structure or replacing packaged terminal air conditioning units in an existing building, Gree E-TAC will meet your needs.
The Gree E-TAC Packaged Terminal Air Conditioning (E-TAC) unit is designed to meet the needs of the architect, engineer, and contractor. For unit installation, Gree’s expert support network will assist in all applicable aspects of the construction project, from preparing a budget to start-up.
4
The following major competitors’ wall sleeves/grilles: Carrier, GE, Amana, Trane, Friedrich and Bryant, and NO accessory retrofit kit is required.
The power cord for the 208/230 volt unit provides LCDI protection by automatically disconnecting power during an unsafe condition. Power can be be restored by pressing the RESET button.
POWER CORD PROTECTION
SEAMLESS BASEPAN
Seamless drawn basepan add protection against water accumulation resulting from storm-driven rain with heavy wind. Gree’s deep basepan hold up to 1-3/4
gallons (6.6 liters) of water without spilling.
CONDENSATE DRAIN VALVE
The temperature--activated drain valve opens when the outdoor temperature drops below 55˚ F (12.8˚ C) to prevent water from freezing in the basepan.
CONDENSATE REMOVAL
Gree’s E-TAC has a new condensate (water) disposal system. The suction pull, along with the slinger ring, draws in water which is sprayed up onto the outdoor coil. The water then evaporates, thus providing better disposal of excess condensate and improving unit efficiency.
NOTE: If it is necessary to control 100% of the condensate, the Drain Kit (Part No.: DRAIN-KIT-1PK) is recommended.
LCDI Power Cord Plug Head
A07551
Condensate Drain Valve Prevents Water
from Freezing in Basepan
SLINGER RING
CONDENSER SECTION
Condensate Removal System
A07550
A07678
GA
E-TAC
9
COASTAL PROTECTION
APPLICATIONS
Hotels and motels
Nursing homes and assisted living care
centers
Offices
Apartments
Single--family dwellings
Home conversions and residential add--ons
NEW CONSTRUCTION
ADVANTAGES FOR NEW CONSTRUCTION
Design Flexibility for the Architect/Engineer
Whisper--quiet performance, indoors and out
No bulky duct system
No separate equipment room
No water towers or additional cooling
equipment
No complex match--up of different HVAC components
Less sensitivity to building orientation (sun, wind, shade)
Optional architectural grille to permit custom exterior appearance
Initial Cost Savings for the Buildin
g Owner
No
expensive component HVAC system
purchase
No equipment room or maintenance engineering staff
Two--part delivery to minimize on--site damage
Weather--protected wall sleeve that goes in place during construction; chassis that slides in place after construction
No seasonal changeover required for cooling or heating -- units are self--contained comfort systems
Lower Operating Costs and Reliable Comfort for The Occupant
Heat pump models offer substantial savings over models with conventional electric resistance heaters
Individual units allow tenants to choose the degree of comfort and operating economy.
Rapid
servicing reduces downtime: complete chassis can be replaced in minutes without disrupting other occupants.
Each unit operates independently of other units in the building. No dependency by building on central HVAC system.
RETROFIT/REPLACEMENT
If you are replacing a unit in an existing wall sleeve, your options include:
Replace the existing wall sleeve with the the polymer wall sleeve. See accessory sleeve section for selecting the correct sleeve for your application. NOTE: in most cases, when replacing the wall sleeve, the exterior grille must also be replaced.
Use an existing sleeve and exterior grille. The Gree E-TAC will fit into:
Friedrich T series and ZoneAire wall
sleeves, with a required wall sleeve extension (see acce
ssory Friedrich
Retrofit Wall Sleeve Adapter).
Whether you are designing a new structure or replacing packaged terminal air conditioning units in an existing building, Gree E-TAC will meet your needs.
The Gree E-TAC Packaged Terminal Air Conditioning (E-TAC) unit is designed to meet the needs of the architect, engineer, and contractor. For unit installation, Gree’s expert support network will assist in all applicable aspects of the construction project, from preparing a budget to start-up.
4
The following major competitors’ wall sleeves/grilles: Carrier, GE, Amana, Trane, Friedrich and Bryant, and NO accessory retrofit kit is required.
The Gree Coastal E-TAC features a corrosion-resistant coating that exceeds the performance and protection of other products of this kind on the market. The coating pro
iving you added reliability in your business.
g
vides salt air corrosion protection
Install the best in corrosion protection for your property, without the worry of performance degradation, coating breakdown or shortened life.
Gree’s Coastal Units are made with a blue-colored anti-corrosion epoxy treated to resist corrosion. This technology maintains excellent heat transfer properties while extending the coil life against damage from salt air and salt water in seacoast installations. This is a tough epoxy coating that
GA
E-TAC
uniformly covers the outside coil surface with a thick .5 to 1.0 mil layer of protection. This advanced material is highly flexible, eliminating cracking problems with traditional coatings and dipped coils.
COASTAL PREMIUM PROTECTION
• Condenser Coils are coated with a corrosion
resistant epoxy resin providing enhanced resistance to acidic and salt air conditions.
• 1500 hr salt spray tested.
• Durable non-corrosive fan wheel and shroud.
• Added protection with durable powder coated paint.
• All exposed fasteners manufactured of high quality
NOTE: Refer to the product warranty for reduced warranty coverage on standard non-corrosion protected units installed within one mile of the of the sea coast or within a corrosive environment.
stainless steel.
f
i
i
t
e
r
d
e
C
S
e
a
c
o
a
s
t
n
o
i
t
c
e
t
o
r
P
Corrosion Protection
A09078
10
HEAT PUMPS PAY THEIR
APPLICATIONS
Hotels and motels
Nursing homes and assisted living care
centers
Offices
Apartments
Single--family dwellings
Home conversions and residential add--ons
NEW CONSTRUCTION
ADVANTAGES FOR NEW CONSTRUCTION
Design Flexibility for the Architect/Engineer
Whisper--quiet performance, indoors and out
No bulky duct system
No separate equipment room
No water towers or additional cooling
equipment
No complex match--up of different HVAC components
Less sensitivity to building orientation (sun, wind, shade)
Optional architectural grille to permit custom exterior appearance
Initial Cost Savings for the Buildin
g Owner
No
expensive component HVAC system
purchase
No equipment room or maintenance engineering staff
Two--part delivery to minimize on--site damage
Weather--protected wall sleeve that goes in place during construction; chassis that slides in place after construction
No seasonal changeover required for cooling or heating -- units are self--contained comfort systems
Lower Operating Costs and Reliable Comfort for The Occupant
Heat pump models offer substantial savings over models with conventional electric resistance heaters
Individual units allow tenants to choose the degree of comfort and operating economy.
Rapid
servicing reduces downtime: complete chassis can be replaced in minutes without disrupting other occupants.
Each unit operates independently of other units in the building. No dependency by building on central HVAC system.
RETROFIT/REPLACEMENT
If you are replacing a unit in an existing wall sleeve, your options include:
Replace the existing wall sleeve with the the polymer wall sleeve. See accessory sleeve section for selecting the correct sleeve for your application. NOTE: in most cases, when replacing the wall sleeve, the exterior grille must also be replaced.
Use an existing sleeve and exterior grille. The Gree E-TAC will fit into:
Friedrich T series and ZoneAire wall
sleeves, with a required wall sleeve extension (see acce
ssory Friedrich
Retrofit Wall Sleeve Adapter).
Whether you are designing a new structure or replacing packaged terminal air conditioning units in an existing building, Gree E-TAC will meet your needs.
The Gree E-TAC Packaged Terminal Air Conditioning (E-TAC) unit is designed to meet the needs of the architect, engineer, and contractor. For unit installation, Gree’s expert support network will assist in all applicable aspects of the construction project, from preparing a budget to start-up.
4
The following major competitors’ wall sleeves/grilles: Carrier, GE, Amana, Trane, Friedrich and Bryant, and NO accessory retrofit kit is required.
OWN WAY
Heat pump models are available at a nominal additional cost. In many locales, the payback is realized in just a few months
SPECIAL FEATURES
Two-Stage Thermostat:
The indoor thermostat senses the indoor temperature and automatically turns on the electric heat to warm the room quickly. After the desired temperature conditions have been satisfied, the thermostat automatically switches to heat pump mode. If compressor failure occurs, thethermostat willprovide backup electric heat automatically.
Outdoor Thermostat:
During senses outdoor coil temperature. It swit to electric heat mode when the outdoor coil temperature is 28˚ F (--2.2˚ C) or below for one (1) minute. The thermostat switches the unit back to heat pump mode when the outdoor coil temperature rises above 40˚ F (4.4˚ C) for ten (10) minutes, which is enough to provide heat to meet demand. The entire operation is completely automatic.
Reversing Valve:
The reversing valve provides quiet refrigerant flow when energized in heating mode. The valve controls the direction of refrigerant flow for both heating and cooling functions and remains energized as long as the controls are in the heat position. When t cooling controls are activated, the valve automatically reverses to the cooling position.
Manual Comp
This configuration dip switch completely locks out the compressor. See Owners Manual for more details. Note that the compressor and heater do not operate at the same time, thus conserving energy.
the heating cycle, the outdoor thermostat
ches the unit
ressor Override Configuration:
he
HOW THE HEAT PUMP WORKS
In Hot Weather:
Gree’s E-TAC units provide indoor comfort in the same manner as conventional air conditioners, removing heat and humidity from indoor air. The heat and humidity is released to the outdoors. Gree’s high efficiency design saves energy and reduces cooling costs.
In Cool Weather:
When the outdoor coil temperature is above 28˚ F (--2.2˚ C), the heat pump draws heat from outdoor air and uses it to heat indoor air. Since heat is transferred and not produced, Gree’s heat pump uses less electricity and reduces energy costs significantly.
In Sub- Freezing Weather:
When the o (--2.2˚ C) for one (1) minute, the unit automatically switches on a built--in electric heater. The compressor stops and the indoor fan circulates warm air produced by the heater. When the outdoor coil temperature rises above 40˚ F (4.4˚ C) for ten (10) minutes, heat pump operation resumes automatically.
A07553
A07553
utdoor coil temperature falls below 28˚ F
A07554
GA
E-TAC
11
FIELD--INSTALLED ACCESSORIES
APPLICATIONS
Hotels and motels
Nursing homes and assisted living care
centers
Offices
Apartments
Single--family dwellings
Home conversions and residential add--ons
NEW CONSTRUCTION
ADVANTAGES FOR NEW CONSTRUCTION
Design Flexibility for the Architect/Engineer
Whisper--quiet performance, indoors and out
No bulky duct system
No separate equipment room
No water towers or additional cooling
equipment
No complex match--up of different HVAC components
Less sensitivity to building orientation (sun, wind, shade)
Optional architectural grille to permit custom exterior appearance
Initial Cost Savings for the Buildin
g Owner
No
expensive component HVAC system
purchase
No equipment room or maintenance engineering staff
Two--part delivery to minimize on--site damage
Weather--protected wall sleeve that goes in place during construction; chassis that slides in place after construction
No seasonal changeover required for cooling or heating -- units are self--contained comfort systems
Lower Operating Costs and Reliable Comfort for The Occupant
Heat pump models offer substantial savings over models with conventional electric resistance heaters
Individual units allow tenants to choose the degree of comfort and operating economy.
Rapid
servicing reduces downtime: complete chassis can be replaced in minutes without disrupting other occupants.
Each unit operates independently of other units in the building. No dependency by building on central HVAC system.
RETROFIT/REPLACEMENT
If you are replacing a unit in an existing wall sleeve, your options include:
Replace the existing wall sleeve with the the polymer wall sleeve. See accessory sleeve section for selecting the correct sleeve for your application. NOTE: in most cases, when replacing the wall sleeve, the exterior grille must also be replaced.
Use an existing sleeve and exterior grille. The Gree E-TAC will fit into:
Friedrich T series and ZoneAire wall
sleeves, with a required wall sleeve extension (see acce
ssory Friedrich
Retrofit Wall Sleeve Adapter).
Whether you are designing a new structure or replacing packaged terminal air conditioning units in an existing building, Gree E-TAC will meet your needs.
The Gree E-TAC Packaged Terminal Air Conditioning (E-TAC) unit is designed to meet the needs of the architect, engineer, and contractor. For unit installation, Gree’s expert support network will assist in all applicable aspects of the construction project, from preparing a budget to start-up.
4
The following major competitors’ wall sleeves/grilles: Carrier, GE, Amana, Trane, Friedrich and Bryant, and NO accessory retrofit kit is required.
POLYMER WALL SLEEVES
For the best performance and longest life, Gree recommends genuine polymer wall sleeves for all installations.
All polymer wall sleeves are made from a molded polymer that is designed for strength and durability. This material has excellent corrosion resistance and a flammability rating of UL94--5V.
The sleeve surface is textured to prevent shine and hide scratches. The rib configuration on the sleeve bottom allows easy chassis removal and aids in drainage
E-TAC
Insulated Polymer Wall Sleeve
Part No.: SLEEVE--INSUL--1PK Gree’s accessory insulated polymer wall sleeve,
with factory--installed insulation, provides superior sound absorption, reduces heat loss and prevents sleeve sweating, a condition that can occur when the outside temperature is cold and the indoor conditions are warm and humid.
Non--Insulated Polymer Wall Sleeve
Part No.: WALL--SLEEVE--1PK Gree’s accessory non-insulated polymer wall sleeve provides a superior appearance and protection for many appli
cations.
IMPORTANT
conditions could influence sleeve sweating, a condition that can occur when the outside temperature is cold and the indoor conditions are warm and humid, the Insulated Polymer Wall Sleeve should be considered.
For applications where weather
f
i
i
t
e
r
d
e
C
S
e
a
c
o
a
s
t
The locating holes in the side and top panels allow for
easy fastening of the sleeve to wall openings. Refer to dimension drawings in Typical Wall Installation and Dimension section.
The sleeve’s alpine mist color (a shade of beige) closely matches the front panel and blends in well with any inside or outside decor. The polymer wall sleeve comes in both insulated (factory installed) or non-insulated, to meet the requirements of every application.
n
o
i
t
c
e
t
o
r
P
Corrosion-Protected Polymer Sleeve
42 in
(1067 mm)
(378 mm)
14 7/8 in
A07633
16 in
(406 mm)
12
FIELD--INSTALLED ACCESSORIES (CONT.)
APPLICATIONS
Hotels and motels
Nursing homes and assisted living care
centers
Offices
Apartments
Single--family dwellings
Home conversions and residential add--ons
NEW CONSTRUCTION
ADVANTAGES FOR NEW CONSTRUCTION
Design Flexibility for the Architect/Engineer
Whisper--quiet performance, indoors and out
No bulky duct system
No separate equipment room
No water towers or additional cooling
equipment
No complex match--up of different HVAC components
Less sensitivity to building orientation (sun, wind, shade)
Optional architectural grille to permit custom exterior appearance
Initial Cost Savings for the Buildin
g Owner
N
o expensive component HVAC system
purchase
No equipment room or maintenance engineering staff
Two--part delivery to minimize on--site damage
Weather--protected wall sleeve that goes in place during construction; chassis that slides in place after construction
No seasonal changeover required for cooling or heating -- units are self--contained comfort systems
Lower Operating Costs and Reliable Comfort for The Occupant
Heat pump models offer substantial savings over models with conventional electric resistance heaters
Individual units allow tenants to choose the degree of comfort and operating economy.
Rapi
d servicing reduces downtime: complete chassis can be replaced in minutes without disrupting other occupants.
Each unit operates independently of other units in the building. No dependency by building on central HVAC system.
RETROFIT/REPLACEMENT
If you are replacing a unit in an existing wall sleeve, your options include:
Replace the existing wall sleeve with the the polymer wall sleeve. See accessory sleeve section for selecting the correct sleeve for your application. NOTE: in most cases, when replacing the wall sleeve, the exterior grille must also be replaced.
Use an existing sleeve and exterior grille. The Gree E-TAC will fit into:
Friedrich T series and ZoneAire wall
sleeves, with a required wall sleeve ex
tension (see accessory Friedrich
Retrofit Wall Sleeve Adapter).
Whether you are designing a new structure or replacing packaged terminal air conditioning units in an existing building, Gree E-TAC will meet your needs.
The Gree E-TAC Packaged Terminal Air Conditioning (E-TAC) unit is designed to meet the needs of the architect, engineer, and contractor. For unit installation, Gree’s expert support network will assist in all applicable aspects of the construction project, from preparing a budget to start-up.
4
The following major competitors’ wall sleeves/grilles: Carrier, GE, Amana, Trane, Friedrich and Bryant, and NO accessory retrofit kit is required.
Metal Insulated Wall Sleeves
Part No.: SLEEVE--STEEL--1PK
Gree’s metal wall sleeves are available in a variety of sizes for most applications and difficult installations. Choose from 14--3/4 in., 18 in., 24 in., 26 in., or 28 in. (375 mm, 457mm, 610 mm, 660 mm, and 711 mm) standard depth sizes. All metal wall sleeves come with factory--installed insulation,
SLEEVE--EXT18--1PK SLEEVE--EXT24--1PK SLEEVE--EXT26--1PK SLEEVE--EXT28--1PK
Amounts in ( ) = mm
Metal Wall Sleeve
designed to minimize heat loss, reduce outdoor noise transmissions into the room and prevent sleeve sweating. In addition, the metal wall sleeve provides a flammability rating higher than UL94--5V.
GA
Wall Sleeve Molding Kit
Part No.: SLEEVE–MOLDING For a superior look and to hide any construction
imperfections, use Gree’s wall sleeve molding kit to trim the wall sleeve to the wall. The molding kit is a perfect solution and can be used with any Gree wall sleeve (matches wall sleeve color).
Friedrich (and ZoneAire) Retrofit Wall Sleeve Adapter
Part No.: FR--SLEEVE--EXT
The Friedrich (and ZoneAire) wall sleeve adapter is constructed of metal and is designed to increase the depth of an existing Friedrich T-series or ZoneAire wall sleeve to accommodate all industry standard PTAC units.
42 in
(1067)
16 in (406)
Available in: 14-3/4 in. (375), 18 in. (457), 24 in. (610), 26 in. (660), 28 in. (711)
A07381
1 IN.
(25.4 mm)
1/2 IN.
(12.7 mm)
Wall Sleeve Molding Kit
A08395
16 IN.
(406.4 mm)
42 IN.
(1067 mm)
3 IN.
(76.2 mm)
A08396
Friedrich Wall Sleeve Adapter Kit
E-TAC
13
17
FIELD--INSTALLED ACCESSORIES (CONT.)
APPLICATIONS
Hotels and motels
Nursing homes and assisted living care
centers
Offices
Apartments
Single--family dwellings
Home conversions and residential add--ons
NEW CONSTRUCTION
ADVANTAGES FOR NEW CONSTRUCTION
Design Flexibility for the Architect/Engineer
Whisper--quiet performance, indoors and out
No bulky duct system
No separate equipment room
No water towers or additional cooling
equipment
No complex match--up of different HVAC components
Less sensitivity to building orientation (sun, wind, shade)
Optional architectural grille to permit custom exterior appearance
Initial Cost Savings for the Buildin
g Owner
N
o expensive component HVAC system
purchase
No equipment room or maintenance engineering staff
Two--part delivery to minimize on--site damage
Weather--protected wall sleeve that goes in place during construction; chassis that slides in place after construction
No seasonal changeover required for cooling or heating -- units are self--contained comfort systems
Lower Operating Costs and Reliable Comfort for The Occupant
Heat pump models offer substantial savings over models with conventional electric resistance heaters
Individual units allow tenants to choose the degree of comfort and operating economy.
Rapi
d servicing reduces downtime: complete chassis can be replaced in minutes without disrupting other occupants.
Each unit operates independently of other units in the building. No dependency by building on central HVAC system.
RETROFIT/REPLACEMENT
If you are replacing a unit in an existing wall sleeve, your options include:
Replace the existing wall sleeve with the the polymer wall sleeve. See accessory sleeve section for selecting the correct sleeve for your application. NOTE: in most cases, when replacing the wall sleeve, the exterior grille must also be replaced.
Use an existing sleeve and exterior grille. The Gree E-TAC will fit into:
Friedrich T series and ZoneAire wall
sleeves, with a required wall sleeve ex
tension (see accessory Friedrich
Retrofit Wall Sleeve Adapter).
Whether you are designing a new structure or replacing packaged terminal air conditioning units in an existing building, Gree E-TAC will meet your needs.
The Gree E-TAC Packaged Terminal Air Conditioning (E-TAC) unit is designed to meet the needs of the architect, engineer, and contractor. For unit installation, Gree’s expert support network will assist in all applicable aspects of the construction project, from preparing a budget to start-up.
4
The following major competitors’ wall sleeves/grilles: Carrier, GE, Amana, Trane, Friedrich and Bryant, and NO accessory retrofit kit is required.
OUTDOOR GRILLES
Polymeric Architectural Outdoor Grilles (Louvered)
Part No.: GRILLE--PLA--BEIGE
GRILLE--PLA--ALPIN
(color matches Gree’s polymer wall sleeve)
GRILLE-PLA-BROWN GRILLE-PLA-WHITE
This value line of polymeric architectural outdoor grilles will blend attractively with most building exteriors. Mounted easily from inside the room, the one--piece, molded grille is designed for protection, enhanced appearance, and superior weather-resistance. The grille is made of durable polymer and has a colorfast, lightly textured finish that blends well with
E-TAC
most exterior finishes.
Aluminum Architectural Outdoor Grilles (Louvered)
Part No.: GRILLE--ALU--CLEAR (anodized aluminum)
GRILLE--ALU--WHITE GRILLE--ALU--BEIGE GRILLE--ALU--ALPIN -Matches wall sleeve
(Custom
colors available)
This premium line of decorative outdoor grilles will enhance the appearance of any building. The grilles are made of strong, durable, extruded, anodized aluminum and are designed to be mounted easily from inside the room. These elegant grilles, available in many standard colors, have baked enamel finishes containing 50% Kynar will withstand the most extreme conditions.
Standard Outdoor Aluminum Grille
Part No.: GRILLE--ALU--STAMP This cost--effective, one--piece standard grille is made
from durable anodized aluminum. The grille is lightweight, has a clear finish, and is easy to install from inside the room.
®
resin, for a superior finish that
IMPORTANT: Gree recommends only the use of Gree-supplied grilles for use with the E-TAC units. However, the architectural designs of a building may dictate the use of special or oversized grilles and/or louvers. Special louvers or any special architectural treatment of the building facade that may restrict free circulation of condenser airflow should be referred to Gree Corporation for evaluation and approval.
See Sizing Outdoor Grille Selection.
f
i
i
t
e
r
d
e
C
S
e
a
c
o
a
s
t
n
o
i
t
c
e
t
o
r
P
Polymer Architectural Grille
Aluminum Architectural Grille
Standard Grille
GA
14
FIELD--INSTALLED ACCESSORIES (CONT.)
APPLICATIONS
Hotels and motels
Nursing homes and assisted living care
centers
Offices
Apartments
Single--family dwellings
Home conversions and residential add--ons
NEW CONSTRUCTION
ADVANTAGES FOR NEW CONSTRUCTION
Design Flexibility for the Architect/Engineer
Whisper--quiet performance, indoors and out
No bulky duct system
No separate equipment room
No water towers or additional cooling
equipment
No complex match--up of different HVAC components
Less sensitivity to building orientation (sun, wind, shade)
Optional architectural grille to permit custom exterior appearance
Initial Cost Savings for the Buildin
g Owner
N
o expensive component HVAC system
purchase
No equipment room or maintenance engineering staff
Two--part delivery to minimize on--site damage
Weather--protected wall sleeve that goes in place during construction; chassis that slides in place after construction
No seasonal changeover required for cooling or heating -- units are self--contained comfort systems
Lower Operating Costs and Reliable Comfort for The Occupant
Heat pump models offer substantial savings over models with conventional electric resistance heaters
Individual units allow tenants to choose the degree of comfort and operating economy.
Rapi
d servicing reduces downtime: complete chassis can be replaced in minutes without disrupting other occupants.
Each unit operates independently of other units in the building. No dependency by building on central HVAC system.
RETROFIT/REPLACEMENT
If you are replacing a unit in an existing wall sleeve, your options include:
Replace the existing wall sleeve with the the polymer wall sleeve. See accessory sleeve section for selecting the correct sleeve for your application. NOTE: in most cases, when replacing the wall sleeve, the exterior grille must also be replaced.
Use an existing sleeve and exterior grille. The Gree E-TAC will fit into:
Friedrich T series and ZoneAire wall
sleeves, with a required wall sleeve ex
tension (see accessory Friedrich
Retrofit Wall Sleeve Adapter).
Whether you are designing a new structure or replacing packaged terminal air conditioning units in an existing building, Gree E-TAC will meet your needs.
The Gree E-TAC Packaged Terminal Air Conditioning (E-TAC) unit is designed to meet the needs of the architect, engineer, and contractor. For unit installation, Gree’s expert support network will assist in all applicable aspects of the construction project, from preparing a budget to start-up.
4
The following major competitors’ wall sleeves/grilles: Carrier, GE, Amana, Trane, Friedrich and Bryant, and NO accessory retrofit kit is required.
SUBBASE
Part No.: PTACSUBBASE--A The easy to install, non--electrical subbase provides
mechanical support and requires no wiring.
All subbase models mount to the wall sleeve,and come with adjustable legs and side skirting to provide a finished appearance.
A subbase (or leveling legs) is required for installations where the wall sleeve extends 4 or more inches into the room or the wall is less than 2 in. (50.8 mm) thick. The minimum clearance between the bottom of the sleeve and the floor is 3--1/4 in. (82.6 mm), and the maximum clearance is 5--1/2 (139.7 mm) inches.
Electrical Subbase Modules
Upgrade non-electrical subbase to a fully electrical subbase by adding an Electrical Subbase module.
The electrical subbase modules have an electrical junction box, receptacle outlet, and cover plate.
Part No: PTAC-REC-230V15-A
Subbase Fuse Kit
Part No.: PTAC--FUSE--15-A
The fuse kit provides in--line over--current protection at the unit when required by NEC (National Electric Code) or local codes.
Subbase Power Disconnect Switch
Part No.: PTAC--SWITCH-A The subbase power disconnect 2--pole switch
provides a recessed power disconnect for the PTAC unit when required by NEC or local codes.
IMPORTANT: The fuse kits and disconnect switch accessories can only be used with Part No. PTAC-SUBBASE-A.
PTAC-REC-230V20-A
PTAC-REC-230V30-A
PTAC-REC-265V15-A
PTAC-REC-265V20-A
PTAC-REC-265V30-A
PTAC-REC-HW-A
PTAC--FUSE--20-A PTAC--FUSE--30-A
IMPORTANT: All standard cord-connected 265-v units will require a field-installed electrical subbase accessory per UL and NEC electrical codes.
Non --Electrical Subbase Assembly
Electrical Subbase Modules
Power Disconnect Switch Module
Subbase Fuse Module
GA
E-TAC
15
Loading...