Gree CHANGE & COSY Series Owner's Manual

Split Air Conditioner
Wall Mounted Model
Please read this owner's manual carefully before operating, and keep it for reference.
WWW.GREE.CA
OWNER’S MANUAL
CHANGE & COSY
SERIE
Notices before use
Please read the following carefully before operating
When the voltage is very high, the compo-
nents can easily be damaged. When the voltage is very low, the compressor vibrates violently, which may damage the refrigerant system, the compressor and the electri­cal components. The voltage level should be stable; there should not be a large variance in voltage.
Disconnect the power supply when the air conditioner
will not be in use for an extended period of time. Accumulated dust may cause over-heating or fire.
Never splice the power cord or use an extension cord.
This may cause overheating or fire.
Do not leave windows and doors open for a long period of time while operating the air conditioner. This will decrease the air conditioning capacity.
Do not block the air
intake or outlet vents
on both the outdoor
and indoor units.
This may decrease the air condi­tioning capacity or cause a malfunction.
The power supply must use a special circuit with air switch protection and the proper capacity. The unit turns on and off automatically based on your settings. Frequently turning the unit off and on may negatively affect or damage the unit.
If there is burning smell or smoke, please turn off the power s
upply and contact the
service center.
Keep combustilbles
at least 150 cm (60")
f
rom the units.
Do not attempt to repair the air conditioner yourself.
I
f the probem continues, the
u
nit may be damaged, and may
c
ause electric shock or fire.
I
f they are too close, it may
c
ause a fire or explosion.
I
ncorrect repairs may cause
e
lectric shock or fire.
C
ontact the service.
Operating principle and special functions for cooling
Operating principle and special functions for heating
Notices for use
Principle:
The air conditioner absorbs heat in the room and sends it outside, so as the indoor ambient temperature decreases, the cooling capacity will increase or decrease based on the outdoor ambient temperature.
Anti-freezing function
If the unit is running in COOL mode and on a low temperature, frost will form on the heat exchanger. When the indoor heat exchanger temperature goes below 0 °C, the indoor unit’s microcomputer will stop runnig the compressor to protect the unit.
Notices for use
Working temperature range
Indoor sideDB/WB(oC) Outdoor sideDB/WB(oC) Maximum cooling 32/23 48/­Minimum cooling 21/15 10/­Maximum heating 27/--- 24/18 Maximum heating 20/--- -15/-6
The operating temperature range (outdoor temperature) for cooling unit is 10 ºC à 48 ºC
Principle:
* The air conditioner absorbs the heat in the room and sends it outside will increase, its
heating capacity will decrease by outdoor ambient temperature. So as the indoor ambient temperature increases, so does the room heating capacity.
* If the outdoor temperature decreases, please use other heating/ventilating equipment.
Defrosting:
* When the outdoor temperature is low but the humidity is high, and the unit has been
running for a long period of time, frost will form on the outdoor unit.
The heating will stop running for 8 - 10 minutes while the auto-defrost is functioning. * While auto-defrosting, the fan motors on both the indoor and outdoor units will stop. * While defrosting, the indoor indicator flashes, and the outdoor unit may emit vapor.
This is due to the defrosting, and is not a malfunction. * After the defrosting has finished,the heating will re-start automatically.
Anti-freezing function:
While in "HEAT" mode, in conjunction with one of the following statues, the indoor heat exchanger hasn't reached the set temperature, the indoor unit will not run, in order to prevent cool air from blowing. (Within 3 mins)
1.Heating starts.
2.After auto-defrosting ends.
3.Heating in low temperatures.
The unit's climate type can be found on the nameplate.
Note: Be sure that there are no obstructions between the receiver and the remote control. Do not drop or throw the remote control. Do not allow the remote control to come into contact with liquids, direct sunlight or intense heat.
Press this button to turn the unit on, then press again to turn the unit off. The Sleep function is canceled, while the unit is off.
Press this button, to activate or deactive the Sleep function. When turned on, Sleep Off is defaulted. When the unit is turned off, the Sleep function is canceled. After the Sleep function is set, the Sleep signal will be displayed. In this mode, the timer can be adjusted. This function is not available.
Press this button to select Auto, Low, Middle or High speed. When turned on the Auto fan speed is the default. Only the Low fan speed can be used in Blow mode.
Press this button to set the clock. The signal icon will appear and blink on and off. Within 5 seconds, the value can be adjusted by pressing + or - button. If the button is held for 2 seconds or more, the minute value will increase by 10 every .5 seconds. When blinking, press the Clock button again. The signal icon will be displayed, which means that the setting has been entered successfully. The first time it is turned on, 12:00 is the default display time and the signal icon will be displayed. When the signal icon is dis­played, it denotes the clock time. When the symbol is not displayed, it is the timer.
Press this button to display the indoor setting temperature or indoor ambient temperature. When the indoor unit is first turned on, it will display the setting temperature. If the temper­ature's display status is changed from another status to" ", the ambient temperature is dis­played. Within 5s, it receives the other remote control signal that will return the display to the setting temperature. If the user hasn’t yet set the temperature display status, it will dis­play the setting temperature.
Press this button to select Auto, Cool,Dry, Fan or Heat modes. Auto mode is the default when power is on. In Auto mode,the temperature is not be displayed. In Heat mode, the initial value is 28°C (82 °F). In other modes, the initial value is 25°C (77 °F).
*Note: Only for cooling and heating unit.
Signal transmitter
Remote control
ON/OFF button
SLEEP button
FAN button
CLOCK button
TEMP button
MODE button
How to use the wireless remote control
Parts and Functions of the Wireless remote control
A
UTO
C
OOL
D
RY
F
AN
Middle fan
Low fan
High fan
Middle fan
Low fan
High fan
"
HEAT*
Loading...
+ 17 hidden pages