Gree 13-04582 Owner's Manual

OWNER’S MANUAL
CANADIAN STANDARDS
3-IN-1 MOBILE
AIR CONDITIONER
Please read the following owner’s manual before using this air conditioner. Keep this manual along with your proof of purchase in a safe place for future reference.
MODEL : 13-04582
© Copyright, Sunrise Tradex Corp., 2006
2
TABLE OF CONTENTS
USE ........................................................................3
SAFETY NOTES ........................................................3
UNIT DIAGRAM
Front........................................................................4
Back ........................................................................4
Installation Kit ..........................................................4
INSTALLATION
Electrical requirements ............................................ 5
Preparing the air conditioner.................................... 5
Choosing the location .............................................. 6
Fixing the exhaust hose ............................................ 6
Wall installation ...................................................... 6
Installation by window type .................................... 7
CONTROL PANEL AND LCD DISPLAY
Control panel .......................................................... 8
LCD display ............................................................ 8
UNIT OPERATION
Cooling .................................................................. 9
Dehumidifying ........................................................ 9
Fan ........................................................................ 9
Auto Mode .......................................................... 10
Sleep Mode .......................................................... 10
Setting the timer .................................................... 10
REMOTE CONTROL ....................................11-12-13
WATER DRAINAGE ................................................14
MAINTENANCE
Cleaning the housing ............................................15
Cleaning the filter ..................................................15
Storage........................................................... ......15
TROUBLESHOOTING CHART ........................... ......16
TECHNICAL SPECIFICATIONS ................................17
CUSTOMER SERVICE ............................................17
WARRANTY............................................................18
WARNING
Before using this air conditioner, please read this owner’s manual carefully. This manual is not a contract and should be used as a reference guide only. We reserve the right to make technical changes at all times without prior notice.
USE
Thank you for purchasing this 3-in-1 mobile air conditioner. This unit is designed to improve indoor living and working comfort by providing cooling, dehumidifying and ventilation with mini­mal installation. Unlike traditional portable units, there is almost no tank to empty as the unit evaporates 80% of the condensate water which is drained through the hot air exhaust hose. When using this appliance, always take basic safety precautions.
SAFETY NOTES
1. Always place the unit on a flat surface in a cleared out area.
2. The unit must be connected to a grounded power supply properly rated. For your safety, this unit is
grounded through the power cord plug when connected to a grounded wall outlet. Never use an adapter plug or extension cord, nor plug the unit in a damaged receptacle.
3. Before unplugging the unit, always turn it off. Always unplug the unit before cleaning or servicing it.. When unplugging the unit, never pull on the power cord - always grip the plug.
4. Ensure that removable covers, hoses and other accessories are correctly fitted before running the unit.
5. Do not install or use the unit in the following places :
• near a heat source ;
• an area with possible gas leakage or in an explosive atmosphere ;
• near a bath, shower enclosure, swimming pool, or any other steamy and wet areas ;
• in a greenhouse.
6. Do not apply insecticides or any other flammable products on the unit.
7. Do not start or stop the unit by plugging in or pulling out the power cord.
8. Do not operate with wet hands or spray water or other liquid on the unit, nor immerse
the appliance.
9. This unit is not intended for the use of children and close supervision is necessary when it is operating near children.
10. Never insert fingers, foreign objects, or anything to obstruct the air inlet and outlet grills. Always warn children.
11. Do not cover the appliance.
12. Do not expose skin or eyes directly to cool air over a long period of time.
13. If an abnormal odour or smoke comes out of the unit, immediately unplug the unit and contact
SUNRISE TRADEX Customer Service.
14. When opening the filter cover, do not touch the internal metal parts of the unit.
15. Always check the power cord for signs of damage before use. If the power cord is damaged, contact
SUNRISE TRADEX Customer Service.
16. Do not place a plant or allow a pet to be exposed directly to the unit cool air flow.
17. Do not put any combustion appliance in the direct path of the unit airflow ; it could affect the
combustion efficiency.
18. Do not sit on the unit or place anything on the unit.
19. Always store the unit standing up. If the unit is to be moved or carried horizontally, wait 24 hours
before plugging the air conditioner.
20. Before storing the unit in a clean and dry area, drain the water and clean the filter.
3
UNIT DIAGRAM
Front
Back
upper air inlet grille
electric cord
hot air outlet
upper air outlet
handle
lower air inlet grille
control panel
lower air inlet grille
water drain hole
INSTALLATION KIT
square hose adaptor to unit
air exhaust hose
window adjustable slider kit
oval hose adaptor to window
4
ELECTRICAL REQUIREMENTS
1. The air conditioner must be grounded ; it is equipped with a LCDI
(Leakage Current Detection and Interruption) power cord and plug This feature will circuit trip the electrical power source if the nominal current leakage between the cord shield and either load conductor exceeds a predetermined value. The cord will remain out of power until the device is manually reset. This is intended to protect against electric shock and to reduce the risk of a fire in the power cord or combustible materials nearby. The cord shield is not grounded and must be considered a shock hazard if exposed. The cord shield must not be connected to ground or to any exposed metal.
2. Do not cut or bypass the plug ground prong. If you do not have a grounded outlet available near the air conditioner, have one installed by a qualified electrician.
3. The power supply rated voltage is ± 6%.
4. Do not connect the unit to an outlet being used by other appliances; ideally, connect to a single
grounded 15A circuit (time-delay fuse or circuit breaker).
5. If the power cord or plug is damaged, call SUNRISE TRADEX Customer Service.
• Electrical ratings of the air conditioner are detailed on the rating plate on the back of the unit.
• Basic electrical requirements are listed hereafter. Please make sure to check the following before installing and connecting your unit.
INSTALLATION
5
Casters
Drain hose
Cap Clamp
Rear grille
PREPARING THE AIR CONDITIONER F
IXING THE CASTERS (Some models only)
To avoid the risk of causing damages to the air conditioner, you must install the casters before using the appliance.
1. Open the accessory bag and take the 4 casters out.
2. Recline the unit, one side at a time, to insert the unit into
the base holes. Do not recline the unit more than 45° from the ground.
3. Screw the casters into the base threaded holes.
INSTALLATION OF THE DRAIN HOSE (Some models only)
You must fix the drain hose before operating the unit.
1. Take out the drain hose, the hose cap and the clamp from the accessory bag.
2. Insert the drain hose into the drain hole on the lower back of the unit. Make sure that the drain hose is correctly inserted into the drain hole.
3. Put the hose cap on the free end of the drain hose.
4. Fix the drain hose on the rear grille with the clamp.
6
INSTALLATION
CHOOSING THE LOCATION
Place the unit on a level surface in a cleared out area where the air outlets cannot be obstructed. For a maximum efficiency, keep a clearance of at least 50 cm
(20”) front
and rear of the unit (Figure A).
FIXING THE EXHAUST HOSE
• During the operation of an air conditioner, a large flow of hot air must be exhausted out of the room. The exhaust hose supplied with this air conditioner must be connected at all times (when running in air conditioning mode) to exhaust the hot air out.
S
LIDE THE HOSE SQUARE ADAPTOR ALL THE WAY
DOWN OVER THE HOT AIR OUTLET ON BACK OF
THE UNIT
(Figure B).
WALL INSTALLATION
• The hot air must be exhausted outdoor through a window, a patio door or directly through the wall.
1. Pick an exterior wall where you will be able
to correctly install the air conditioner and the hot air outlet.
2. Drill a hole of 13,3 cm (5-1/4”) on the
exterior wall. The hole must be 40 to 130 cm (16” to 50”) above the floor (Figure C).
3. Fix the external end of the exhaust hose onto
the wall pre-drilled hole.
NOTE :
The hot air exhaust hose must be as short as possible. To avoid hot air backdraft and guarantee an efficient exhausting of the hot air, make sure the hose is not bent, kinked or twisted (Figure D). In order to do so, please check upon the following :
• Position the air conditioner as close as possible to the outside air outlet.
• Unscrew the hose connector, cut the excess hose and screw the connector back on the hose.
• Do not forget to leave a 50 cm (20”) clearance all around the air conditioner.
• To maximize the efficiency of the air conditioner, you may insulate the exhaust hose with a 6” insulating flexible tube (not included).
840 mm
50 cm50 cm50 cm
450 mm
370 mm
Figure A
Figure B
130 cm (50”)
40 cm (16”)
MUR
Figure C
APPAREIL
Figure D
Note : model may differ from illustration.