When you see this symbol, the subsequent instructions and
warnings areserious- follow without exception. Your life and
!
!
the lives of others depend on it!
These instructions explain how to install the battery operated Acre Counter. The Acre Counter is
used to calculate and display the field acres and
total acres accumulated on the implement it is
mounted on and calibrated for.
These instructions apply to:
194-210AElectronic Acre Meter Kit
Manual Update
Refer to the 3S-4000 operator’smanual for detailed information on safely operating, adjusting,
troubleshooting and maintaining the Acre
Counter. Refer to the parts manual for part
identification.
195-242M-A Operator’sManual
195-242PParts Manual
Before You Start
Page 6 has a detailed listing of parts included in
the Acre Counter package. Use this list to inventory parts received.
Tools Required
• Electric drill
• Basic hand tools
Definitions
Right hand and left hand as used in this manual
are determined by facing the direction thedrillwill
travelwhile in use.
1. Select a ground drivenshaft with easy access. Install the two halves of the magnet actuator around the shaftand slide theactuator
together.Positionthe magnet actuator next to
the bearing mount.
Note: Take care when sliding the actuator together so not to break one of the tabs.
2. Remove the two nuts and lock washersfrom
the carriage bolts which hold the bearing to
the mount.
3. Place the bracketwhich holds the pickup sensor over the bolts and replace the nuts and
lock washers. Tighten nuts.
4. Attach the pickupsensor to the sensor bracket. Secure the ground wire to one of the
mounting screws. Slide the sensor so it is no
more than 1/8" from the magnet actuator. Do
not allow the sensor to touch the magnet actuator. Tighten screwsto hold in place.
Great Plains Mfg., Inc.
21821
Figure 1
Magnet Actuator
Refer to Figure 2
5. Mount the acre counter console to the drill
frame. Select a location close to the pickup
sensor which allows easy access for reading
or adjustments. Pick a location which allows
the console to be mounted in a vertical position.
6. Hold the console in place and mark where to
drill the holes forthe mounting screws.
7. Drill 11/64" holes where marked and secure
the acre counter console in place with two
3/4" x 10-16 self taping screws.
8. Connect the cable from sensor pickupto the
acre counter console. Windup and tie out of
the way any extra cable.
21822
Figure 2
Acre Counter Console
194-209M8/22/2006
Page 3
Great Plains Mfg., Inc.
Operating Instructions
The battery operated acre counter operates in
one of two modes.In sleep mode, the display is
blank, and the counter is accumulatingacres.
Sleep mode will be entered if a button is not
pressed for 20 seconds. In entry mode, the display is on, and the operator can enter values. To
getinto entrymode,pressthe FUNC button.If you
continue to press the FUNC button,the acre
counter will cycle throughthe functions that itcan
perform.The icons abovethe digitsindicatewhich
function is selected. The available functions are:
• Field Acres
• Total Acres
• Pulses per Mile
• Width
• Password
Installation Instructions
3
Field Acres
Refer to Figure 3
Press the FUNC button until the "FIELD" icon appears in the display.The digits indicate the acres
coveredsince the fieldacre counter wascleared.
To clear the fieldacre count, depress the UP and
DOWN buttons for2 seconds.
Field acres will count in tenths of an acre up to
9999.9 acres.
Total Acres
Refer to Figure 4
Press the FUNCbuttonuntil the "TOTAL" icon appears in the display.The digits indicate the acres
covered since the total acre counter was cleared.
To clear the total acre count, press and hold the
UP and DOWN buttons for 2 seconds.If a password has been entered you will not be able to
clear the total acre count.
Total acres will count from 1 to 99999 acres.
FLD
ACRES
Figure 3
TOT
8/22/2006
ACRES
Figure 4
194-209M
Page 4
Acre Counter Update
4
Pulses per Mile
Press the FUNC buttonuntil the "PULSES" icon
appears in the display. The number in the display
indicates how many timesthe shaft rotatesfor every mile driven.
There are 2 methods to enter the pulses per mile:
Refer to Figure 5
a. Ifyouknowthenumber,selectit using the
UP and DOWN buttons. When youpress
the FUNC button, the Landtracker will acceptthenumberinthedisplayasthenew
pulses per mile.
Refer to Figure 6
b. If you do not know the pulses per mile,
press and hold the UP and DOWN buttons until "0000" appears in the display.
The "COUNT" icon will appear.The acre
counter is now counting shaft rotations.
Enter the cab and drive one mile. Press
the FUNC button to wake up the acre
counter. The "PULSES" and "COUNT"
icons will re-appear. The number displayed is the pulses per mile. Press the
FUNC button to accept the setting. The
"COUNT"iconwilldisappear.Ifyoucould
not drivea mile,you can calculate the
pulses per mile using a formula.
Great Plains Mfg., Inc.
PULSES
Figure 5
PULSES
pulses per mile =
pulse count
distance in miles
Note: If a password is set, you will not be able to
adjust the pulses per mile.
Width
Refer to Figure 7
PresstheFUNCbuttonuntilthe"WIDTH"icon appears in the display. The number displayed is the
width of your implement in feet.
To adjustthe width, pressthe UP andDOWN buttons.If a password has been entered,youwill not
be able to adjust the width.
The width can be adjusted from 0 to 99.9 feet, in
tenths of a foot.
CNT
Figure 6
WIDTH
FT
Figure 7
194-209M8/22/2006
Page 5
Great Plains Mfg., Inc.
Password
The password function allows you to protect the
total acre count, pulses per mile and width settings with a password. This stops anyonefrom
accidentally changing those settings.When the
acrecounteris shipped, the passwordis disabled.
Youcanmodify thepulsesper mileandimplement
width at any time.
Press the FUNC buttonuntil the "PASS" icon appears. The digits will display the word "Ent" or
"dIS"
If the display shows "dIS"
Refer to Figure 8
The password is disabled. The total acre
count, pulses per mile,width and password
settings can be adjusted using the up and
down buttons. The password can also be
changed using the up and down buttons.
If the display shows "Ent"
Installation Instructions
PASS
Figure 8
5
Refer to Figure 9
You must enter your password using the UP
and DOWN buttons. When yourpassword is
displayed, press the FUNC button to test the
password. If the password is correct, you will
be able to change the acre counter settings.
The password will be viewable until the acre
counterpowersdown. Whentheacrecounter
is powered up again, you willhave to re-enter
the password to change settings.
If the password is not correct, you will not be
able to change the acre counter settings.
When the "PASS" function is selected again,
"Ent" will appear in the display.
Changing the password
Refer to Figure 10
Select a new password using the UP and
DOWN buttons. Press the FUNC button until
the word "SEt" appears in the display. Release the FUNC button.The numberin the
displayis your newpasscode.Make sure you
write it down!To disable the password,try setting it to 0000. Press and hold the FUNC buttonuntiltheword"dIS"appearsin the display.
If the passwordis forgotten, it can be disabled by
removingthebatteries. The passwordis intended
for rental units. It is recommended that a seal be
affixed to the rear plate of the acre counter to determine if the settings have been tampered with.
PASS
Figure 9
PASS
Figure 10
8/22/2006
194-209M
Page 6
Acre Counter Update
6
Battery Replacement
The battery operatedacre counter uses 3AA batteries.Thebatteriesshould last between5and10
years.The acre counter will last much longer than
that.Eventuallyyou will havetoreplace the batteries. The acre counter will display "LObA" when
the batteries require replacement. Remove the
acre counter from the implement and undo the 4
screwson the back of the case. This willseparate
the housing from the rear plate. Replace the batteries with 3 high quality AA alkaline batteries.
Note: This unit is dust andsplash resistant,under
nocircumstanceshouldthisunitbesubmergedin
any conductive, corrosiveor flammable liquid.
Great Plains Mfg., Inc.
194-210A Electronic Acre Meter Kit
Your kit includes:
Qty.Part No.Part Description
1168-240D METER SHAFT SENSOR MNT BRACKET
1194-209M MANUAL ELECTRIC ACRE METER
2801-172C SCREW HEX SLT 10-16X3/4PTH
2802-506C RHSNB 1/4-20X1 3/4 GR5
1823-184C VANSCO ACRE COUNTER
2890-351C BUSHING 5/8 OD X 11/32 ID
194-209M8/22/2006
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.