Service Note: If you are experiencing difficulties or are dissatisfied with your purchase, please contact CFM at
the telephone number listed above prior to returning your grill to the store.
X-FrameModelSeriesGasGrill
Installation1Chapter
Necessary Information to
Safely Use a Gas Grill
The gas fuel used by this product is
highly flammable and must be used in
a responsible and cautious manner.
It is your responsibility to assemble,
operate, and maintain your gas
barbecue grill properly.
·
Operating this or any gas-fired appliance
in an enclosed area can produce a build-up
of carbon-monoxide, which could result in
injury or death.
2. Installation must conform with local
codes
either the National Fuel Gas Code, ANSI
Z223.1, NFPA 54 (USA), or CAN/CGA-B
149.2, Propane Installation Code (Canada)
and CAN/CGA-B 149.1 Natural Gas
Installation Code.
To check local codes, contact your local gas
dealer or gas company listed in the Yellow
Pages for recommended installation
procedures and regulations.
3. This appliance is not intended to be
installed in or on a recreational vehicle
and/or boat.
or, in the absence of local codes, with
If these instructions are ignored, there
is a possibility of a hazardous fire or
explosion which could result in proper-
ty damage, physical injury or death.
Choosing a Safe Location
for a Gas Barbecue Grill
1. The gas barbecue grill may only be used
for cooking out-of-doors.
· Do not operate this barbecue in garages,
breeze ways, sheds or any enclosed area.
4. Keep the barbecue grill at least 24
inches (61 cm) away from any combustible
construction.
·
Do not use a grill under a ceiling or cover
where the heat or flame could cause
damage.
·
Choose a level surface where the grill is
not facing directly into the wind.
·
Avoid moving the grill during use.
5. The grill area must be clear and free from
combustible materials, gasoline, and any
other flammable liquids or vapors.
·
Do not use lighter fluid or charcoal
briquettes in a gas grill. The flow of
combustion and ventilation air is not to be
obstructed. The ventilation openings of the
cylinder enclosure must be kept free and
clear from other debris. Do not store grill
covers or other items in the cylinder area.
4
The L.P. Fuel Supply System
9. Make sure that the drip pan is in place
under the grill bottom.
Hot drippings from cooking food could
·
damage the fuel supply system.
6. Do Not store a spare L.P. gas cylinder
under or near this appliance.
Do not store an L.P. cylinder in a building,
garage or any other enclosed area. Instead,
store the cylinder outdoors in a well
ventilated area, away from people and out of
the reach of children.
7. NOT FOR USE BY CHILDREN.
Place your barbecue grill in a location
·
away from children and pets.
Do not leave grill unattended when in use.
·
IMPORTANT:
unattended when in use.
NEVER leave a grill
Portable L.P. Gas
Barbecue Grills
WARNING:
appliance designed for L.P. gas. Use only
liquid propane (L.P.) gas in an appliance
designed for L.P. gas.
L.P. Gas
Liquid Propane (abbreviated L.P.) gas is
stored under high pressure inside a cylinder
and will vaporize when released. It is
important that there are no leaky connections
on the grill fuel supply system. Refer to the
Leak Testing section of this manual.
The L.P. Fuel Supply System
An L.P. gas grill requires a fuel delivery
system made up of a L.P. gas supply
cylinder, a fuel regulator with hose and a
gas-control valve.
Do not use natural gas in an
8. The outside of the barbecue grill will
become hot during use.
To avoid burns, do not touch any hot grill
·
surface. If necessary, use a protective glove
when operating control knobs, tank shut-off
valve, or lid handle.
Do not place combustible material, such
·
as cloth or plastic, on grill surface during
use.
·
Do not lean on side tables or place more
than 15 pounds of weight on a side table.
The L.P. Fuel Supply System
5
Dual Burner
Fuel-Control Valve
4. The pressure regulator and hose
assembly provided is factory set at an outlet
pressure of 11 inches water column (.4 lb.
per sq. Inch).
Type 1 Fuel
Regulator
Fuel Supply
Valve
Orifice
Hose
The L.P. Fuel Supply System
(the fuel regulator and hose)
FUEL REGULATOR AND HOSE
The fuel regulator supplied is equipped with
a Type 1 coupling nut. Do not attempt to
connect to any other L.P. cylinder not
equipped with a mating Type 1 cylinder
valve. This grill is not to be used with any
other cylinder connection device.
The fuel regulator and hose assembly with
the Type 1 fitting supplied must be used with
the appliance. Do not use a hose and
regulator assembly other than the one
supplied with the grill or a manufacturer’s
replacement fuel pressure regulator
assembly.
The Type 1 connection system has the
following features:
1. The system will not allow gas to flow until
a positive connection has been made.
2. The system has a thermal element that
will shut off the flow of gas between 240°F
and 300°F.
3. The system has a flow-limiting device
which, when activated, will limit the flow of
gas to 10 cubic feet per hour.
WARNING:
Any attempt to adjust the
regulator is dangerous and could create a
situation causing personal injury or property
damage. Consult your L.P. gas dealer if you
think the regulator is not working properly.
L.P. GAS SUPPLY CYLINDER
L.P. Cylinders can be obtained at the store
where you purchased your grill or from an
authorized L.P. gas dealer.
Cylinder Control
Valve
L.P. Gas
Cylinder
NOTE:
L.P. Gas
Cylinder
NOT
INCLUDED
The L.P. Fuel Supply System
(L.P. gas cylinder)
L.P. GAS CYLINDER SPECIFICATIONS
Any L.P. gas-supply cylinder used with this
grill must be approximately 12 inches
diameter and 18 inches high.
The maximum
fuel capacity must be 20 pounds of propane.
Full-cylinder weight should be approximately
38 pounds (43.7 lbs. Nominal water
capacity).
6
The L.P. gas cylinder must have a shut-off
valve
cylinder-valve outlet.
terminating in a Type 1 L.P. gas-
A Type 1 compatible
cylinder with a Type 1 cylinder valve has a
positive seating connection that does not
permit gas flow until a positive seal has been
obtained.
The cylinder must be arranged for vapor
withdrawal. It must also include a collar to
protect the cylinder valve. A safety-relief
device having direct communication with the
vapor space of cylinder must be provided.
This will expel high-pressure gas if the
cylinder is overfilled or overheated.
Have the gas dealer weigh the cylinder
after filling to ensure that the cylinder is not
overfilled.
DANGER:
a.) Do not store a spare L.P. gas cylinder
under or near this appliance.
b.) Never fill the gas cylinder beyond 80
percent full.
c.) If the information in (a.) and (b.) Is not
followed exactly, a fire causing serious
injury or death may occur.
All L.P. gas cylinders used with this
appliance shall be constructed and marked
in accordance with the specifications for L.P.
gas cylinders of the U.S. Department of
Transportation (DOT) or the National
Standard of Canada, CAN/CSA-B339,
Cylinders, Spheres and Tubes for
Transportation of Dangerous Goods; and
Commission, as applicable; and shall be
provided with a listed overfilling-prevention
device. Read labels on the L.P. gas-supply
cylinder.
DANGER:
Do not insert any foreign objects
into the valve outlet. You may damage the
back check, A damaged back check can
cause a leak, which could result in explosion,
fire, severe personal injury or death.
Allow only a qualified L.P. gas dealer to
fill or repair an L.P. gas-supply cylinder.
Inform the gas dealer if it is a new or used
cylinder to be filled. Caution the gas dealer
not to overfill the fuel cylinder.
TRANSPORTING A FULL CYLINDER
WARNING:
Handle a full cylinder with care.
Gas is under high pressure.
You should transport only one cylinder at a
time. Transport the cylinder in an upright and
secure manner with the control valve turned
off and the POL dust cap in place.
Do not transport a cylinder in the passenger
compartment of a vehicle.
Do not leave cylinder in direct sunlight or in
a high-heat area such as a closed car trunk.
High-heat areas could cause the relief valve
to vent gas.
Use a cylinder cap on the cylinder-valve
outlet during transport and when the cylinder
is not connected to the grill. Keep cylinder
valve closed when not in use.
After filling, have the gas dealer check for
leaks and that the relief valve remains free to
function.
7
Loading...
+ 12 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.