Table of Contents
Table of Contents
Safety Information
Safety and Usage Information
Tips
Overview
Device Components
List
LCD Display
Initial Start-Up
General Instructions
Power Supply
Insert the Batteries
Pair-up
Set Up Your Profile
Select Measurement Unit
Initialising Your Scale
Weight Only Operation
Start Measuring
First Measurement
Daily Measurement
Fast Measurement
Clear Your Profile
Manage Your Health
Body Fat Indicator
Data Transmission
Troubleshooting
Error Prompt
When Measuring ...
When Data Transmitting...
Specifications
Maintenance
Warranty
FCC Regulations
Appendix
Health Tips – About Body Fat
Health Tips – About Body Water
Health Tips – About Muscle Mass
Health Tips – About Bone Mass
Health Tips – About BMI
EMC Guidance
2
3
4
4
5
6
6
6
7
8-9
9
10
10
11
12
13
13
13
14
15
15-16
17
18
19
19
20
21
22
23
23
24
25
...............................................................................................
...........................................................................................................................................
.................................................................................................................
..........................................................................................................................................
.................................................................................................................
.................................................................................................................
........................................................................................................
...................................................................................................................
.............................................................................................................................
....................................................................................................................
..................................................................................................................
..................................................................................................................
....................................................................................................................
........................................................................................................
............................................................................................................................
...............................................................................................................................
......................................................................................................................................
.....................................................................................................................................
..............................................................................................................................
...................................................................................................................
........................................................................................................................
...............................................................................................................
..............................................................................................................
..................................................................................................................
...........................................................................................................................
..................................................................................................................
...............................................................................................
.........................................................................................................
...................................................................................................
................................................................................................
............................................................................................
..........................................................................................................................
2 3
Safety InformationSafety Information
INDICATIONS FOR USE
The Greater Goods,LLC
Body Fat Analyzer measures weight and uses bio-electrical impedance analysis (BIA) technology to estimate BMI, body fat, total body water percentage, bone mass, and muscle mass in generally healthy children 10-17 years old and healthy adults. It is intended for use in the domestic setting only.
Tips
To ensure the accuracy of measurement, please follow below instructions when
you start measurement.
Place the scale on a flat, hard surface. Soft surface such as carpet will affect the performance of the scale.
Step onto the platform with bare feet. Stand still and keep full contact with the electrodes until the measurement is complete.
Start measurement at least two hours after Getting up or Dinning.
Avoid measurement immediately after strenuous exercise, sauna or bath, drinking, and dinning.
Always start measurement in the same time slot and on the same scale located on the same flat, hard surface.
For maximum accuracy and repeatability , it is recommended that you should use the device in the same time of the day and on the same location.
Body fat percentage estimates will vary with the amount of water in the body, and can be affected by dehydration or over-hydration due to such factors as alcohol consumption, menstruation, illness, intense exercise, etc.
The condition of the skin on the bottom of your feet can affect the reading. The natural effects of aging or activity can make this skin hard. Take the reading with clean, slightly damp feet for best accuracy. If you are having a problem on operating this scale please contact customer service.
The warning signs and symbols are essential to ensure your correct and safe use of this product and protect you and others from injury. Please kindly find the meanings of the warning signs and symbols, which you may encounter in the label and user manual, as follows:
Safety and Usage Information
CAUTION
Symbol for “THE OPERATION GUIDE MUST BE READ”
Symbol for “MANUFACTURER”
Symbol for “ENVIRONMENT PROTECTION – Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice”
Symbol for “TYPE BF APPLIED PARTS”
The Bluetooth Combination Mark
Symbol for “SERIAL NUMBER”
Symbol for “MANUFACTURE DATE”
Symbol for “DIRECT CURRENT”
Greater Goods,LLC’s Body Fat Analyzer 0375,0376 offers you a seamless way to manage your health. Please be aware that this device is designed for healthy population over 10 years old self-measuring and self-monitoring body compositions. Any information provided by this device is in no way meant to treat, cure or prevent any disease or illness from happening. If in doubt, contact your physician. This device is contraindicated for any female subject who may be suspected of, or is pregnant. Otherwise, the effects of this device on the fetus are unknown. This device is contraindicated for any person who is connected to a wearable or implantable electronic device or instrument such as a pacemaker or defibrillator. This device should not be used for anyone who is acutely or chronically ill because of suffering from a disease or taking medications that affect your water levels. The accuracy of readings for these patients has not been verified. Specific medical advice should be obtained from a physician. 0375,0376 is equipped with data transmission function. It may emit electromagnetic energy so as to perform its intended function. Nearby portable and mobile RF communications equipment can affect the performance of 0375,0376. And the device can interfere vicinity electrical equipment. Manufacturer will make available on request circuit diagrams, component parts list,etc. WARNING:No modifications of this equipment is allowed. This may result in increased EMISSIONS or decreased IMMUNITY of 0375,0376. Please use the device according to the user manual. Any misuse can cause electric shock,burns, fire and other unexpected hazards. Please use and storage the device under the environment which was provided in the user manual. Don’t expose the device to extreme temperatures, direct sunlight, moist or corrosive environment. Do not step on the scale when your body or feet are wet, especially after bathing or showering to prevent slipping.
Please keep the device out of reach of infants, children or pets, since inhalation or swallowing of small parts is dangerous or even fatal. Please don't use the device out of lifetime any more because degraded sensors and electrodes, or loosened electrodes can degrade performance or cause other problems. If you have an allergy to stainless steelplease avoid to contact to the electrodes of the device. The patient is an intended operator. The patient can measure, transmit data and charge battery under normal circumstances and maintain the device and its accessories according to the user manual.
4 5
OverviewOverview
User Interface: Setting
Body Fat Analysis Result
Water Analysis Result
Muscle Mass Analysis Result
Bone Mass Analysis Result
Pound
Kilogram
Percentage
Inch
Centimeter
Age
Male
Male Athlete
Female
User ID (Range from U1 to U8 )
Successful Bluetooth Connection
Data transmitting / pending to transmit to wireless wellness system
Low Battery
LCD Display
Body Mass Index
List
1. Body Fat Analyzer 0375,0376
2. Four AAA-size Batteries (1.5V each)
3. User Manual
Device Components
LCD Display
Up Key
Set Key
Down Key
Conductor
Conductor
Battery Compartment
UNIT Button
Female Athlete
7
6
Greater Goods,LLC Body Fat Analyzer 0375,0376 applies BIA (Bio-impedance Analysis)
technology. A small amount of weak current flows through the human body so as to detect the bio-impedance and estimate BMI, body fat, body water, muscle mass and bone mass. The electrical current is small and may not be felt.
This BIA technology is cheap, safe, non-invasive, toxic-free and harmless. It also
possesses the characteristics of simple operation and abundant information.
The current mentioned above is less than 0.5mA. However, please be aware that anyone with an wearable or implantable medical electronic instrument, such as a pacemaker, must avoid using this device.
The intended use of this device is for healthy children 10-17 years old and healthy adults.
General Instructions
If SUCCEED, symbol will be shown on the LCD.
If FAIL, symbol “E1” will be shown on the LCD.
Initial Start-UpInitial Start-Up
Pair-Up
With the advanced Bluetooth 4.0 technology applied, the mobile or portable equipments, which are equipped with Bluetooth function in line with BLE Technical Specifications established by global organization Bluetooth SIG, are capable to receive your personal health data.
Turn on Bluetooth and the App. Make sure both are ON when pair-up is proceeding.
Press and hold “UNIT” button in the back of the scale to start pair-up.
Symbol and symbol will be shown on the
LCD alternatively, indicating pair-up is proceeding.
CAUTION
When the symbol appears, the device will power off. Then you shall replace with a new set of batteries. Please replace all four batteries at the same time. Do NOT mix the old batteries with the new one. Worn batteries are hazardous waste. Do NOT dispose of them together with the household garbage. Please refer to the local ordinances and recycling instructions regarding disposal of the worn batteries and scrapped device. If you do not intend to use this unit for a prolonged period of time, it is advisable to remove the batteries before storing.
Insert the Batteries
Open the battery door in the back of the scale.
Insert the batteries (4 x 1.5V AAA) into the battery compartment according to the polarity indications marked inside the compartment.
* The digits “ ” will be shown on the LCD.
Close the battery door and wait until the digits “ ” are shown on the LCD.
Battery Life: Approx. 120 days
(Battery capacity: 230 mAH. If measured three times per day, each measurement takes about 46s. The current for measurement is about 30 mA , while the current when shutdown is about 30 uA.)
Power Supply
Battery Mode: 6V, 4 x AAA batteries
Loading...