Great Bear Healthcare Libra Instructions For Use Manual

0120
Latex Free Box is
Recyclable
Temperature
Keep DryWashHandsDo not use if
packaging is damaged
Denotes the use of
Phthalates
®
Products available
Nightingale Home Delivery Service
through
That’s all – We will do everything else!
Complimentary Items Available:
Storage and Disposal
1) The Libra Leg Bag should be stored at an ambient temperature and allowed to come to room temperature before use
2) Dispose with normal household waste – do not ush down the toilet
Cautions
Ensure you ll in the Date Fitted Box (8) to allow you to monitor how long the Libra Leg Bag has been in use. Change the Leg Bag every 5-7 days
Do not reuse the Libra Leg Bag after disconnection
Keep out of the reach of children
Order Codes
Libra Leg Bag – Prescription
All Prescription Libra Leg Bags come with Fabric Backing and one pair of Leg Bag Straps as standard
Product Code Capacity Tube Length Qty
10130G 350ml Direct Inlet 10 10131H 500ml Direct Inlet 10 10132J 750ml Direct Inlet 10 10133K 1000ml Direct Inlet 10 10100A 350ml Short (10cm) 10 10102C 500ml Short (10cm) 10 10106G 750ml Short (10cm) 10 10104E 500ml Long (30cm) 10 10108J 750ml Long (30cm) 10 10120W 1000ml Long (30cm) 10 10105F 500ml Adjustable (45cm) 10 10110L 750ml Adjustable (45cm) 10 10122Y 1000ml Adjustable (45cm) 10
Libra Leg Bag – Hospital
All Hospital Libra Leg Bags come without Fabric Backing and one pair of Leg Bag Straps in every peel pouch as standard
Product Code Capacity Tube Length Qty
10230C 350ml Direct Inlet 10 10200W 350ml Short (10cm) 10 10202Y 500ml Short (10cm) 10 10206C 750ml Short (10cm) 10 10204A 500ml Long (30cm) 10 10208E 750ml Long (30cm) 10 10205B 500ml Adjustable (45cm) 10 10210G 750ml Adjustable (45cm) 10
1. Call Freephone 0800 318 559 or 02920 747 770.
2. Please ensure you have your GP details to hand.
3. Tell us which products are required and how many.
Please make sure you have at least two week’s supply in hand before re-ordering.
Hand Gels
Radar Keys
Wet and Dry Wipes
Disposable Bags
Night Stands
Sponge Bag
Great Bear Healthcare Ltd 1 Lambourne Crescent, Cardiff Business Park, Cardiff, CF14 5GF T +44 (0) 29 2074 7770
mail@gbhl.co.uk www.greatbearhealthcare.co.uk
Libra Leg Bag
Instructions for use
LIBRAIFUV2/2019
A UK manufacturer committed to Urology.
Your Libra®Leg Bag
Instructions For Use
Libra Leg Bags are for the daytime storage and drainage of urine
Designed to be connected directly to a Catheter or Sheath for continuous drainage and should only be disconnected when a new bag is required
Libra Leg Bags can also be connected to a Night Bag for overnight drainage (page 3)
Libra Leg Bags should be changed every 5-7 days
3
2
1
7
9
Key
1 Protective Cap 6 Graduated Scale* 2 Ridged Inlet Connector 7 Outlet Tap 3 Needle Free Sample Port 8 Date Fitted Box 4 Inlet Tube 9 Silicone Sleeve 5 Eyelets
* The graduated scale is an approximation and should not be
used for accurate measurement of urine output
Before Use
1) Wash Hands
2) Open peel pouch and remove Libra Leg Bag from its packaging
3) Ensure the lever on the outlet tap (7) is in the closed position (Diagram 1)
4) Remove the grey protective cap (1) from the Libra inlet connector (2)
Direct Connection
1) Insert the ridged inlet connector (2) into the end of the Indwelling Catheter or Sheath.
4
Insert the connector fully to allow a secure connection
2) The Libra Leg Bag should be positioned on the thigh or calf, depending on the tube length, and
5
secured appropriately with the leg bag straps provided
3) Feed the leg bag straps through the eyelets(5) on the bag and ensure the wavy silicone lines
6 8
faces onto the leg
4) Make sure the inlet tubing (4) isn’t kinked which can restrict the ow of urine
Emptying
1) Empty the Libra Leg Bag by pushing the lever on the outlet tap(7) downwards (Diagram 2)
2) After emptying, wrap the outlet tap with a tissue and pat a number of times before gently wiping around the inside of the valve. This will dislodge any residual urine
3) Remember to close the tap after emptying (Diagram 1)
4) The outlet tap(7) can be twisted to avoid accidental emptying
Overnight Drainage
If you require additional drainage for overnight use, a night bag can be connected as part of an overnight link system
Diagram 1 Close Tap
Diagram 2 Open Tap
1) When you go to bed, do not disconnect your Leg Bag from your Catheter or Sheath
2) Insert the connector of your Night Bag to the silicone sleeve(9) on your Leg Bag. Insert the connector fully to allow a secure connection
3) Once connected, turn the Libra Leg Bag tap to the open position (Diagram 2) to allow the overnight drainage into the Night Bag
4) Before disconnecting the Night Bag in the morning, ensure the Libra Leg Bag tap is in the closed position (Diagram 1)
5) Do not reconnect a used Night Bag
Libra Leg Bags with adjustable tubing
Libra Leg Bags with an adjustable tubes have a 45cm inlet tube(4) which can be cut to the desired length and tted with the spare connector included in the peel pouch. These Adjustable Leg Bags are designed for direct connection to a Sheath system
1) Place the Libra Leg Bag on your leg in the desired position and secure as instructed on page 1
2) Measure how long you need the tubing and cut to the desired length
3) Remove the Leg Bag from your leg and insert the spare connector into the inlet tube
4) Connect the Libra Leg Bag as per the instructions on page 1
Caution: Do not cut the tube length yourself if you are connecting to an Indwelling Catheter as the sterility of the product may become compromised. Please contact our helpline on 0800 055 6270 for further advice
Loading...