Grayhill Graphic MicroDisplay User Manual

Graphic MicroDisplay
• Easily display custom graphic icons, text boxes and active gauge elements.
- Use PC-based software tools
to develop graphic objects
- Store graphic objects in
on-board ash memory
- Recall objects at run
time via J1939 commands
- Recall objects at run time
using the menu object
- Recall objects at run time
using the screen list object
• Controlled via J1939 PGNs
- Native coding not required
The MicroDisplay makes it easy to create screens with custom graphics, text and even gauges that automatically adjust based on J1939 values.
Due to its innovative design, native coding is not required for custom user interfaces. Screens and graphic objects are created with the included PC
software tool and stored in the on-board ash memory.
When in use the MicroDisplay can be controlled two different ways. First, a vehicle’s ECU (Electrical Control Unit) can send and receive commands to con­trol the display. Second, with the new Menu Object and Screen List Object the display can be programmed to provide stand-alone functionality. The menu object allows users to enter and navigate a menu using the menu key. The Screen List Object allows users to quickly navigate through favorite screens (objects) by pressing one of the right and left arrow buttons.
ENVIRONMENTAL SPECIFICATIONS
Operating temperature ANSI/ASAE EP455 5.1.1 Level 2: -50°C to +85°C with optional heater
Storage Temperature ANSI/ASAE EP455 5.1.2 Level 2: -50°C to +85°C
Thermal Shock ANSI/ASAE EP455 5.1.3 -40°C to 70°C at a rate of 4°C/min (1 hour at extremes)
Altitude (Barometric Pressure) ANSI/ASAE EP455 5.2 101.3kPa to 18.6kPa
Sand and Dust SAE J1455
Solar Radiation ISO 4892-2 Method B
Humidity ANSI/ASAE EP455 5.13 96% humidity at 35°C for 240 hours
Salt Fog ANSI/ASAE EP455 5.9 5% aqueous solution of NaCl @ 35°C and
Chemical resistance ISO 16750-5 EP 455 5.8.2
Ingress Protection IP67 with mating connector
-25°C to +85°C without heater
a pH between 6.5 and 7.2 for 48 hours
• Ideal for off-highway vehicle applications
- Virtual gauges
- Diagnostic menus
- Fault indicators & service reminders
• Rated for off-highway vehicles
- Extended operating temperature
range: -50º C to +85ºC (with heater)
- Protected against the ingress of
liquids and dust: IP67 rated seal
• 3.2-inch backlit LCD (256x128)
- Excellent daylight readability
- Transective LCD with anti-glare
- Software controlled RGB backlighting
- Four level grayscale graphics
• Custom Options Available
- Keypad backlight color
- Key colors and legends
- Icons/screens pre-loaded
• System Interface
- One CAN-bus port
- Two 200mA outputs (standard option)
- Three discrete inputs (standard option
- One RS-485 serial port (custom option)
• Styled to sit next to Grayhill standard 20-button 3K Keypad
Your Experts in Cab Controls
Grayhill specializes in the design, development and production of human interface controls, including:
- Cab user interface design
- Customized control panels
- CAN-bus interface devices
www.grayhill.com
www.grayhill.com
www.grayhill.com
DIMENSIONS
3.2
[81,28]
ELECTRICAL PERFORMANCE SPECIFICATIONS
Maximum load ANSI/ASAE EP455 5.1.1 Level 2
Jump start voltage EP455 5.10.2 36V for 60 minutes; -36V for 60 minutes
Short circuit protection EP455 5.10.4 36V
Reverse polarity protection
Starting prole ISO 16750-2 Level II code C, Level IV code A
Battery-less operation ANSI/ASAE EP455 5.11.3 Level 2
Load dump ISO 7637-2 Test Pulse 5b Us* = 60V
Switching spikes ISO 7637-2 Test Pulse 3a
Wire harness inductance ISO 7637-2 Test Pulse 2a
Wire harness inductance­switching
Inductive load pulse ANSI/ASAE EP455 5.11.4
Mutual coupling ANSI/ASAE EP455 5.11.6
Alternator eld decay ANSI/ASAE EP455 5.11.2
EP455 5.10.3 -36V
and 3b
and 2b
ISO 7637-3 Test Pulse a and b
Level 2
PART NUMBER DESCRIPTION
3D32XK-200 MicroDisplay with CAN, I/O 3D32HK-200 MicroDisplay with CAN, I/O and heater 3D32XKR-200 MicroDisplay with CAN 3D32HKR-200 MicroDisplay with CAN and heater 3D32CABLE-1 MicroDisplay Programming Cable with Power Supply
CONTACT GRAYHILL FOR CUSTOM OPTIONS
Grayhill, Inc.
561 Hillgrove Avenue phone: (708) 354-1040 LaGrange, Illinois 60525 fax: (708) 354-2820
www.grayhill.com
www.grayhill.com
www.grayhill.com
ELECTROMAGNETIC COMPATIBILITY SPECIFICATIONS
ESD ANSI/ASAE EP455 5.12 Level 1 +/- 25KV
Radiated Immunity EP455 5.16 Level 1
Conducted emissions SAE J1113-41 Level 4
Radiated emissions ISO14982
CE COMPLIANCE
EMC EN 13309:2010 ESA
MECHANICAL PERFORMANCE
Vibration, Random ANSI/ASAE EP455
Vibration, Sinusoidal ANSI/ASAE EP455
Shock / Crash Safety ANSI/ASAE EP455 5.14 11ms half sine pulse of 490 m/s2 in 3
Drop ANSI/ASAE EP455
specications subject to change
MOUNTING INFO
Use M6 Nut (1mm pitch) Max Torque 25 in-lbs
5.15.1
5.15.2
5.14.2 Level 1
REAR CONNECTOR
Mating Connector: DEUTSCH DT06-12SA
2h each axis @52.4m/s2 RMS overall acceleration and spectral power density of 2m2/s3 from 50Hz to 2000Hz
A logarithmic sweep from 10Hz to 2000Hz to 10Hz over a period of 20 minutes for 4 hours in each of 3 orthogonal axes with amplitude
1.5mm from 10Hz to 40Hz and a constant acceleration of 35m/s2 RMS from 40Hz to 2KHz
perpendicular axes
Drop component 400 mm onto a hardwood benchtop on all practical edges.
0 Function
1 V in Positive
2 V Return
3 RS-485 +
4 RS-485 -
5 Digital in 1
6 Digital in 2
7 Digital in 3
8 Digital out 1
9 Digital out 2
10 CAN shield
11 CAN HI
12 CAN LOW
Bulletin 1144
Rev 06/14
Loading...