----General Precautions
----Warranty
Model: CCT10/CCT20
GRAVITY MEASUREMENT, INC.
CCT10/CCT20 USER MANUAL
2
Important Safety Information
READ ALL INSTRUCTIONS BEFORE USING SCALES TO ENSURE MAXIMUM SAFETY, BEST PERFORMANCE, AND TO GAIN KNOWLEDGE OF OUR SCALE, IT IS ESSENTIAL THAT YOU OR ANY OTHER OPERATOR OF THE SCALE READ AND UNDERSTAND THE CONTENTS OF THIS MANUAL BEFORE OPERATING THE DEVICE.
When using an electrical device, basic precautions should always be followed,
including the following:
1. Please use only the original power cord or DC adapter supplied with the scale. Other cords or adapters may damage the scale.
2. DC adaptor is used to charge the battery, and scale can operate without DC adaptor.
3. Avoid using long power extension cords – this may cause interference
4. Do not use on surfaces or in areas where vibration, air movement or temperature change. Do not place in direct sunlight or near air conditioning vents.
5. Avoid high humidity (greater than 80%) that might cause condensation, and keep away from direct contact with water and other corrosive chemicals.
6. Static may influence the weighing result. To reduce the static, wipe the pan and sc ale with antistatic wipes.
7. Don’t impact or drop heavy objects on the scale – this may affect accuracy, or cause damage. Do not stack material on the scale when it is not in use.
8. Battery should be removed if the scale is not used for a long period of time. Battery should be recharged every 3 months.
9. Place items to be weighed as close to center of the pan as possible
10. Only use fingers to operate the keypad. Do not press with hard or sharp objects.
CCT10/CCT20 USER MANUAL
3
Warranty
Gravity Measurement, Inc. (Schenectady, New York) offers one-year limited warranty (parts and labor) for the components failed due to defects in materials or workmanship. Warranty starts from the date of delivery.
During the warranty period, should any repairs be necessary, the purchaser must inform its supplier or Gravity Measurement. The company or its authorized technician reserves the right to repair or replace the components at any of its workshops depending on the severity of the problems. However, any freight involved in sending the faulty units or parts to the service center should be borne by the purchaser.
The warranty will cease to operate if the equipment is not returned in the original packaging and with correct documentation for a claim to be processed. All claims are at the sole discretion of Gravity Measurement.
This warranty does not cover equipment where defects or poor performance is due to misuse, accidental damage, exposure to radioactive or corrosive materials, negligence, faulty installation, unauthorized modifications or attempted repair or failure to observe the requirements and recommendations as given in this User Manual. Additionally, rechargeable batteries (where supplied) are not covered under warranty.
Repairs carried out under the warranty does not extend the warranty period. Components removed during the warranty repairs become the company property.
CCT10/CCT20 USER MANUAL
4
What is inside Box
AC/DC adaptor (110V) Counting scale CCT 10/20 Scale, with adhesive film covered platter. Two parts are separated to protect the load cell during transportation. Two wire seals. The wire seal is used usually by the inspector of Department of Weight and Measure or authorized dealer. The wire seal is threaded through a metal rode that protrudes through the bottom of the device and also through a hole in the scale base adjacent to the metal rode.
Set up the Scale
Place the scale on a stable, level surface out of the way of air currents. The scale must be level during use. Adjust the feet and use the integrated bubble at the front of the scale to achieve level. Be sure that scale does not rock back and forth. Ensure no weight is on the pan when turning on the scale. Scale is operated using the rechargeable battery. AC adaptor is used to charge the battery, and scale can operate without DC adaptor.
LCD Display
CCT10
Size: 77 mm x 27 mm X 2.8 mm Font height: 16 mm
CCT10/CCT20 USER MANUAL
5
CCT20
Size: 80 mm x 71 mm X 2.8 mm, Font height: 16 mm
CCT10/CCT20 USER MANUAL
6
Control Panel
P2
UNITS
Z
T
COUNT
SAMPLE
COUNT ALARM
M +
M R
C E
P1
P2
PCS WT
MEM
8 3 2
5 4 6
7
1 . 9
0
M01 M21
M02 M22
M03 M23
M04 M24
M05 M25
M01 M26
M07 M27
M08 M28
M09 M29
M10 M30
M11 M31
M12 M32
M14 M34
M15 M35
M01 M36
M17 M37
M18 M38
M19 M39
M20 M40
M13 M33
Loading...
+ 11 hidden pages